MVA-FIAM9H-C [VICOR]
DC-DC Unregulated Power Supply Module, 1 Output, 500W, Hybrid, MODULE-29;型号: | MVA-FIAM9H-C |
厂家: | VICOR CORPORATION |
描述: | DC-DC Unregulated Power Supply Module, 1 Output, 500W, Hybrid, MODULE-29 |
文件: | 总6页 (文件大小:382K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
Military COTS 28 Vin Filter
MVA-FIAM9
Input Attenuator Module
Features
• EMI filtering-MIL-STD-461E(1)
• Transient protection-MIL-STD-704A/E/F,
MIL-STD-1275A/B/D
• Environments-MIL-STD-810, MIL-STD-202
• Environmental stress screening
• Output power up to 500 W
• Output current up to 18 A
• Inrush current limiting
• Cold plate mounting
Product Highlights
Absolute Maximum Rating
The MVA-FIAM9 is a DC front-end module
that provides EMI filtering and transient
protection. The MVA-FIAM9 enables
designers using Vicor’s Maxi, Mini, Micro
Series 24 V & Maxi Series 28 V DC-DC
converters or VIPAC Arrays to meet conducted
emission / conducted susceptibility per MIL-
STD-461E; and input transients per MIL-
STD-704A/E/F and MIL-STD-1275A/B/D.
The MVA-FIAM9 accepts an input voltage
of 10 – 36 Vdc and delivers output power up
to 500 W.
Parameter
Rating
36
Unit
Vdc
Vdc
Vdc
Notes
Continuous
+In to –In
See Fig.1
50 mS,
100
250
70 µs
MTBF per MIL-HDBK-217F (MVA-FIAM9M)
Temperature
Environment
MTBF
3,379
608
Unit
25 °C
Ground Benign: G.B.
Naval Sheltered: N.S.
1,000 Hrs
1,000 Hrs
50 °C
MVA-FIAM9 is mounted on a 4.69" x 3.62"
coldplate with a height of 0.81” and
65 °C
Airborne Inhabited Cargo: A.I.C.
476
1,000 Hrs
convenient input and output connectors.
(1)EMI performance is subject to a wide
variety of external influences such as PCB
construction, circuit layout etc. As such,
external components in addition to those
listed herein may be required in specific
instances to gain full compliance to the
standards specified.
Part Numbering
MVA-FIAM9
M
-
C
Product Grade Temperatures (°C)
Blank = Standard
Product
C = ON/OFF Control Enabled
Grade Operating
Storage
H = –40 to +100 –55 to +125
M = –55 to +100 –65 to +125
Military COTS 28 Vin Filter
Page 1 of 6
Rev 1.3
vicorpower.com
800 735.6200
10/2012
MVA-FIAM9
SPECIFICATIONS
(typical at T = 25 °C, nominal line and 75% load, unless otherwise specified)
BP
INPUT SPECIFICATIONS
Parameter
Min
Typ
Max
36
Unit
Vdc
A/µF
Vdc
Vdc
Vdc
Vdc
Notes
Input voltage
10
28
Continuous
Inrush limiting
Transient immunity
0.007
100
250
70
50 ms per MIL-STD-1275A/B/D, continuous operation
70 µs per MIL-STD-1275A/B/D, continuous operation
20 ms per MIL-STD-704A, continuous operation
12.5 ms per MIL-STD-704E/F, continuous operation
50
OUTPUT SPECIFICATIONS
Parameter
Min
Typ
Max
500
18
Unit
W
Notes
Output power
Output current
A
Efficiency
Internal voltage drop
96
97
0.85
%
V
1.5
500 W, 25 °C baseplate
External capacitance
See Figure 5 on page 4
50 V
330
1000
µF
CONTROL PIN SPECIFICATIONS
Parameter
Min
Typ
Max
Unit
Notes
ON/OFF control
Enable (ON)
0.0
3.5
1.0
5.0
Vdc
Vdc
Referenced to – Vout
Disable (OFF)
100 kΩ internal pull up resistor
SAFETY SPECIFICATIONS
Parameter
Min
Typ
1,500
2,121
Max
Vrms
Vdc
Unit
Notes
Input/Output to Base
Input/Output to Base
Dielectric withstand
EMI
Standard
Test Procedure
Notes
MIL-STD-461E
Conducted emissions:
When using with V28 series converters a 27 µH inductor is
needed between the filter and converter for compliance
below 30% of rated power.
CE101, CE102
Conducted susceptibility:
CS101, CS114, CS115, CS116
EMI performance is subject to a wide variety of external influences such as PCB construction, circuit layout etc. As such, external components
in addition to those listed herein may be required in specific instances to gain full compliance to the standards specified.
GENERAL SPECIFICATIONS
Parameter
Weight
Min
Typ
Max
0.7 (318)
2
Unit
Lbs (grams)
Years
Notes
Warranty
Military COTS 28 Vin Filter
Page 2 of 6
Rev 1.3
vicorpower.com
800 735.6200
10/2012
MVA-FIAM9
SPECIFICATIONS (CONT.)
MODULE ENVIRONMENTAL QUALIFICATION
Altitude
MIL-STD-810F, Method 500.4, Procedure I & II, 40,000 ft. and 70,000 ft. Operational.
Explosive Atmosphere
MIL-STD-810F, Method 511.4, Procedure I, Operational.
Vibration
MIL-STD-810F, Method 514.5, Procedure I, Category 14, Sine and Random vibration per Table 514.5C for Helicopter AH-6J Main Rotor
with overall level of 5.6 G rms for 4 hours per axis. MIL-STD-810F, Method 514.5C, General Minimum Integrity Curve per Figure 514.5C-17
with overall level of 7.7 G rms for 1 hour per axis.
Shock
MIL-STD-810F, Method 516.5, Procedure I, Functional Shock, 40 g. MIL-S-901D, Lightweight Hammer Shock, 3 impacts / axis, 1,3,5 ft.
MIL-STD-202F, Method 213B, 60 g, 9 ms half sine. MIL-STD-202F, Method 213B, 75 g, 11ms Saw Tooth Shock.
Acceleration
MIL-STD-810F, Method 513.5, Procedure II, table 513.5-II, Operational, 2-7 g, 6 directions.
Humidity
MIL-STD-810F, Method 507.4.
Solder Test
MIL-STD-202G, Method 208H, 8 hour aging.
MODULE ENVIRONMENTAL STRESS SCREENING
Parameter
H-Grade
M-Grade
Operating temperature
Storage temperature
-40 °C to +100 °C
-55 °C to +125 °C
-55 °C to +100 °C
-65 °C to +125 °C
12 cycles
-65 °C to +100 °C
12 cycles
-65 °C to +100 °C
Temperature cycling*
Ambient test @ 25°C
Power cycling burn-in
Functional and parametric ATE tests
Hi-Pot test
Yes
12 hours, 29 cycles
-40 °C and +100 °C
Yes
Yes
24 hours, 58 cycles
-55 °C and +100 °C
Yes
Visual inspection
Yes
Yes
Test data
vicorpower.com
vicorpower.com
*Temperature cycled with power off, 17°C per minute rate of change.
Military COTS 28 Vin Filter
Page 3 of 6
Rev 1.3
vicorpower.com
800 735.6200
10/2012
MVA-FIAM9
Figure 1 — Transient Immunity: MVA-FIAM9 output response
Figure 2 — Conducted Noise; MVA-FIAM9 and model
to an input transient.
V28A12M200B DC-DC converter operating at 28 Vdc, 200 W
0
-10
-20
-30
-40
-50
-60
-70
-80
-90
2000
1800
1600
1400
1200
1000
800
600
400
200
30
0.01
0.1
1
10
0
Frequency (MHz)
40
50
60
70
80
90
100
CM Insertion Loss
Vin (V)
DM Insertion Loss
Figure 3 — Shut down time of MVA-FIAM9 vs. Overvoltage
Figure 4 — MVA-FIAM9 insertion loss
Note:The MVA-FIAM9 is shown in the on state. To disable,
open the connection between ON/OFF and –Out.
4,700 pF
0.01 µF
+IN
+OUT
+S
+IN
Maxi, Mini, Micro
24 Vdc or 28 Vdc Input
DC-DC Converter
PC
+OUT
F1
Transorb P/N
19180-510
MVA-
EMI
GND
0.2 µF
ON/OFF
SC
Input
C1
FIAM9
+OUT
PR
–S
–IN
–OUT
–IN
0.01 µF
4,700 pF
Component Suggestions
Recommended Fuse: (F1) 20 A (max), Bussmann ABC style
Capacitance: (C1) 330 µF (min), 1000 µF (max)
Figure 5—Transient, Surge Protection and Recommended Reverse Polarity Protection.
Military COTS 28 Vin Filter
Page 4 of 6
Rev 1.3
vicorpower.com
800 735.6200
10/2012
MVA-FIAM9
1
10
20
1
9
11
10
18
Input Connector
Output Connector
Pin #
Function
Pin #
Function
Pin #
Function
1 – 4
–Vin
1
+Vout
10
+Vout
5 – 7
8
+Vin
NC
2
3
4
5
6
7
8
9
+Vout
+Vout
N/C
11
12
13
14
15
16
17
18
+Vout
+Vout
NC
9
PE protective earth
PE protective earth
–Vin
10
N/C
NC
11 – 13
14 – 17
18
N/C
On / Off
–Vout
–Vout
–Vout
+Vin
–Vout
–Vout
–Vout
NC
19
PE protective earth
PE protective earth
20
Input Mating
Vicor P/N
Output Mating
Vicor P/N
Connector
Housing
Connector
Housing
24795
24796
24828
25050
24796
25067
Pin
Kit
Pin
Kit
Note: The MVA-FIAM9H and MVA-FIAM9M are delivered with the On / Off control already configured as On using a 0 Ohm resistor on the
underside of the output connector board. The MVA-FIAM9H-C and MVA-FIAM9M-C are delivered without the 0 Ohm resistor installed,
.
allowing for user control of the On / Off functionality
Figure 6 — MVA-FIAM9 Outline and Pinouts
Military COTS 28 Vin Filter
Page 5 of 6
Rev 1.3
vicorpower.com
800 735.6200
10/2012
MVA-FIAM9
Vicor’s comprehensive line of power solutions includes high density AC-DC and DC-DC modules and
accessory components, fully configurable AC-DC and DC-DC power supplies, and complete custom
power systems.
Information furnished by Vicor is believed to be accurate and reliable. However, no responsibility is assumed by Vicor for its use. Vicor makes no
representations or warranties with respect to the accuracy or completeness of the contents of this publication. Vicor reserves the right to make
changes to any products, specifications, and product descriptions at any time without notice. Information published by Vicor has been checked and
is believed to be accurate at the time it was printed; however, Vicor assumes no responsibility for inaccuracies. Testing and other quality controls
are used to the extent Vicor deems necessary to support Vicor’s product warranty. Except where mandated by government requirements, testing of
all parameters of each product is not necessarily performed.
Specifications are subject to change without notice.
Vicor’s Standard Terms and Conditions
All sales are subject to Vicor’s Standard Terms and Conditions of Sale, which are available on Vicor’s webpage or upon request.
Product Warranty
In Vicor’s standard terms and conditions of sale, Vicor warrants that its products are free from non-conformity to its Standard Specifications (the
“Express Limited Warranty”). This warranty is extended only to the original Buyer for the period expiring two (2) years after the date of shipment
and is not transferable.
UNLESS OTHERWISE EXPRESSLY STATED IN A WRITTEN SALES AGREEMENT SIGNED BY A DULY AUTHORIZED VICOR SIGNATORY, VICOR
DISCLAIMS ALL REPRESENTATIONS, LIABILITIES, AND WARRANTIES OF ANY KIND (WHETHER ARISING BY IMPLICATION OR BY OPERATION OF LAW)
WITH RESPECT TO THE PRODUCTS, INCLUDING, WITHOUT LIMITATION, ANY WARRANTIES OR REPRESENTATIONS AS TO MERCHANTABILITY,
FITNESS FOR PARTICULAR PURPOSE, INFRINGEMENT OF ANY PATENT, COPYRIGHT, OR OTHER INTELLECTUAL PROPERTY RIGHT, OR ANY OTHER
MATTER.
This warranty does not extend to products subjected to misuse, accident, or improper application, maintenance, or storage. Vicor shall not be liable
for collateral or consequential damage. Vicor disclaims any and all liability arising out of the application or use of any product or circuit and assumes
no liability for applications assistance or buyer product design. Buyers are responsible for their products and applications using Vicor products and
components. Prior to using or distributing any products that include Vicor components, buyers should provide adequate design, testing and
operating safeguards.
Vicor will repair or replace defective products in accordance with its own best judgment. For service under this warranty, the buyer must contact
Vicor to obtain a Return Material Authorization (RMA) number and shipping instructions. Products returned without prior authorization will be
returned to the buyer. The buyer will pay all charges incurred in returning the product to the factory. Vicor will pay all reshipment charges if the
product was defective within the terms of this warranty.
Life Support Policy
VICOR’S PRODUCTS ARE NOT AUTHORIZED FOR USE AS CRITICAL COMPONENTS IN LIFE SUPPORT DEVICES OR SYSTEMS WITHOUT THE EXPRESS
PRIOR WRITTEN APPROVAL OF THE CHIEF EXECUTIVE OFFICER AND GENERAL COUNSEL OF VICOR CORPORATION. As used herein, life support
devices or systems are devices which (a) are intended for surgical implant into the body, or (b) support or sustain life and whose failure to perform
when properly used in accordance with instructions for use provided in the labeling can be reasonably expected to result in a significant injury to the
user. A critical component is any component in a life support device or system whose failure to perform can be reasonably expected to cause the
failure of the life support device or system or to affect its safety or effectiveness. Per Vicor Terms and Conditions of Sale, the user of Vicor products
and components in life support applications assumes all risks of such use and indemnifies Vicor against all liability and damages.
Intellectual Property Notice
Vicor and its subsidiaries own Intellectual Property (including issued U.S. and Foreign Patents and pending patent applications) relating to the
products described in this data sheet. No license, whether express, implied, or arising by estoppel or otherwise, to any intellectual property rights is
granted by this document. Interested parties should contact Vicor's Intellectual Property Department.
Vicor Corporation
25 Frontage Road
Andover, MA, USA 01810
Tel: 800-735-6200
Fax: 978-475-6715
email
Customer Service: custserv@vicorpower.com
Technical Support: apps@vicorpower.com
Military COTS 28 Vin Filter
Page 6 of 6
Rev 1.3
vicorpower.com
800 735.6200
10/2012
相关型号: