TFS309 [VECTRON]

Filter Specification; 过滤器规格
TFS309
型号: TFS309
厂家: Vectron International, Inc    Vectron International, Inc
描述:

Filter Specification
过滤器规格

过滤器 LTE
文件: 总5页 (文件大小:44K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
tfs309.doc  
version 1.5  
13.07.2000  
VI TELEFILTER  
Filter Specification  
TFS 309  
1/5  
Measurement condition  
Ambient temperature:  
Input power level:  
Terminating impedances  
for input:  
23 °C  
dBm  
0
540 Ohm // -1,7 pF  
540 Ohm // -1,7 pF  
for output:  
External coil: 116 nH  
Characteristics  
Remark:  
Reference level for the relative attenuation a of the TFS 309 is the insertion loss. The insertion loss a is defined as the insertion loss at the  
rel  
C
e
nominal frequency f . The centre frequency f is the arithmetic mean value of the upper and lower frequencies at the 3 dB filter attenuation level  
N
relative to the insertion loss a . The nominal frequency f is fixed on 309,6 MHz without tolerance. The specified values have to be reached in  
e
N
operating temperature range.  
D a t a  
typ.value  
tolerance/limit  
2,1 ... 4,1 dB  
Insertion loss  
(Reference level)  
a
f
e
2,75 dB  
Nominal frequency  
Centre frequency  
-
309,600 MHz  
-
N
f
309,62 MHz  
C
1 dB bandwidth  
BW  
270  
kHz  
-
Relative attenuation  
a
rel  
f
N ± 1,8 MHz ... fN ± 6 MHz  
47  
28...65  
dB  
dB  
min. 30  
min. 20  
dB  
dB  
fN ± 6 MHz ... fN ± 100 MHz  
VSWR  
@ fN  
1,2:1  
min.  
1,8 : 1  
Group delay  
GD  
@ fN  
2,6  
-
µs  
max.  
4,6  
µs  
Input power  
max. 10  
dBm  
Operating temperature range  
- 5 °C ... + 80 °C  
Temperature coefficient of frequency TC  
Frequency inversion temperature  
ca. – 0,036 ppm/K²  
+ 25 °C  
Generated:  
Checked / approved:  
VI TELEFILTER  
Vectron International, Inc.  
Potsdamer Straße 18  
D 14 513 TELTOW / Germany  
Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30  
E-Mail: tft@telefilter.com  
267 Lowell Road  
Hudson, NH 03051 / USA  
Tel: (603) 598-0070 Fax: (603) 598-0075  
E-Mail: vti@vtinh.com  
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is  
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.  
tfs309.doc  
version 1.5  
13.07.2000  
VI TELEFILTER  
Filter Specification  
TFS 309  
2/5  
Construction, pin configuration and 50 - matching network  
(All dimensions in mm)  
5.0 SQ +0.15  
-0.1  
7
5
S 309  
M24  
1
3
Date code  
Pin 1  
Output  
Pin 2,6,7  
Pin 3  
Pin 4,8  
Pin 5  
Ground  
Datecode:  
K
L
M
...  
Year+week  
1998  
1999  
External Coil  
Package Ground  
Input  
2000  
50 Ohm Test circuit 1  
L1  
L2  
5
1
C1  
C2  
SAW  
3
L3  
2, 4, 6, 7, 8  
50 Ohm Test circuit 2  
C1  
C2  
5
1
L1  
L2  
SAW  
3
L3  
2, 4,6,7,8  
VI TELEFILTER  
Potsdamer Straße 18  
Vectron International, Inc.  
267 Lowell Road  
D 14 513 TELTOW / Germany  
Hudson, NH 03051 / USA  
Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30  
E-Mail: tft@telefilter.com  
Tel: (603) 598-0070 Fax: (603) 598-0075  
E-Mail: vti@vtinh.com  
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is  
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.  
tfs309.doc  
version 1.5  
13.07.2000  
VI TELEFILTER  
Filter Specification  
TFS 309  
3/5  
Stability Characteristics  
After the following tests the filter shall meet the whole specification:  
1. Shock:  
500g, 18 ms, half sine wave, 3 shocks each plane;  
DIN IEC 68 T2 - 27  
2. Vibration:  
10 Hz to 500 Hz, 0,35 mm or 5g respectively, 1 octave per min, 10 cycles per plan, 3 plans;  
DIN IEC 68 T2 - 6  
3. Damp heat:  
(cycle)  
25 °C to 55°C / 95% r.H. / 10 cycles  
DIN IEC 68 - 2 – 30 Db  
4. Resistance to  
solder heat (reflow):  
max. 2 times reflow process;  
for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4;  
Packing  
Tape & Reel:  
IEC 286 - 3, with exception of value for N and minimum bending radius;  
tape type II, embossed carrier tape with top cover tape on the upper side;  
max. pieces of filters per reel:  
Real of empty components at start:  
Real of empty components at start including leader:  
Trailer  
3000  
min 300 mm  
min 500 mm  
min 300 mm  
Tape (all dimensions in mm)  
EMBOSSED CARRIER TAPE  
W
Po  
Do  
E
:
:
:
:
:
12  
4
± 0,3  
± 0,1  
Po  
P 2  
D
o
1,5 + 0,1  
1,75 ± 0,1  
E
F
Ao  
F
5,5 ± 0,05  
0,75  
G (min) :  
D1  
CT  
W
Bo  
P2  
P1  
:
2
± 0,05  
± 0,1  
:
8
G
D1(min) :  
1,5  
Ao  
Bo  
CT  
:
:
5,3 ± 0,1  
5,3 ± 0,1  
9,5 ± 0,1  
P1  
COVER TAPE  
:
W
2
Reel (all dimensions in mm):  
A
:
330  
W1  
:
:
12,4 + 0,2  
W2 (max) :  
18,4  
N (min)  
C
50  
C
A
:
13  
± 0,2  
N
W
1
The minimum bending radius is 45 mm. The mounting surface of the filters faces the bottom side of the embossed carrier tape.  
The marking of the filters is able to read if the view is directed on the upper side of the carrier tape with the sprocket holes on  
the right side of the tape.  
VI TELEFILTER  
Potsdamer Straße 18  
Vectron International, Inc.  
267 Lowell Road  
D 14 513 TELTOW / Germany  
Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30  
E-Mail: tft@telefilter.com  
Hudson, NH 03051 / USA  
Tel: (603) 598-0070 Fax: (603) 598-0075  
E-Mail: vti@vtinh.com  
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is  
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.  
tfs309.doc  
version 1.5  
13.07.2000  
VI TELEFILTER  
Filter Specification  
TFS 309  
4/5  
Air reflow temperature conditions  
1st and 2nd air reflow profile  
Name: pre-heating periods  
main-heating periods  
over 200 °C  
peak temperature  
255 °C ± 5 °C  
Temperature: 150 °C - 170 °C  
Time:  
60 sec. - 90 sec.  
20 sec. - 25 sec.  
Chip-mount air reflow profile  
260  
240  
220  
200  
180  
160  
140  
120  
100  
80  
60  
40  
20  
0
0
20  
40  
60  
80  
100  
120  
140  
160  
180  
200  
220  
240  
time / sec.  
Table for temperature vs. time during the air reflow process  
Tolerance of temperatures: ± 5 °C  
time / sec.  
0
temperature / °C  
time / sec.  
140  
150  
160  
170  
180  
190  
195  
200  
205  
210  
215  
220  
230  
240  
temperature / °C  
23  
34  
46  
60  
80  
103  
121  
134  
143  
150  
154  
156  
158  
159  
160  
161  
164  
170  
180  
205  
230  
255  
230  
205  
180  
165  
140  
120  
10  
20  
30  
40  
50  
60  
70  
80  
90  
100  
110  
120  
130  
VI TELEFILTER  
Potsdamer Straße 18  
Vectron International, Inc.  
267 Lowell Road  
D 14 513 TELTOW / Germany  
Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30  
E-Mail: tft@telefilter.com  
Hudson, NH 03051 / USA  
Tel: (603) 598-0070 Fax: (603) 598-0075  
E-Mail: vti@vtinh.com  
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is  
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.  
tfs309.doc  
version 1.5  
13.07.2000  
VI TELEFILTER  
Filter Specification  
TFS 309  
5/5  
History  
Version  
Reason of Changes  
Add preliminary values for termination impedance  
Name  
Date  
1.2  
Dr. Wall  
09.05.2000  
Add history  
Modify monthly date code into weekly date code  
1.3  
1.4  
1.5  
Correct tape and reel information  
Add limit values for package dimensions  
Add final termination conditions  
Add typical filter data  
Dr. Wall  
Dr. Wall  
Dr. Wall  
15.06.2000  
28.06.2000  
13.07.2000  
Add limits for insertion loss  
Add maximum input power  
Add reletive attenuation value for FN ± 6 MHz ... FN ± 100 MHz  
Add group delay  
Notice 1 dB bandwidth instead of 3 dB bandwidth  
Increase window for insertion loss to two dB  
Maximum input power changed to 10 dBm  
VI TELEFILTER  
Potsdamer Straße 18  
Vectron International, Inc.  
267 Lowell Road  
D 14 513 TELTOW / Germany  
Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30  
E-Mail: tft@telefilter.com  
Hudson, NH 03051 / USA  
Tel: (603) 598-0070 Fax: (603) 598-0075  
E-Mail: vti@vtinh.com  
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is  
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.  

相关型号:

TFS309A

Vectron International Filter specification
VECTRON

TFS311

Filter Spezification
VECTRON

TFS311A

Filter specification
VECTRON

TFS312

Filter specification
VECTRON

TFS315

Filter Specification
VECTRON

TFS315D

Filter Specification
VECTRON

TFS315E

Filter specification
VECTRON

TFS315F

Filter specification
VECTRON

TFS315G

Filter specification
VECTRON

TFS315H

Filter specification
VECTRON

TFS315K

Filter specification
VECTRON

TFS315L

Vectron International Filter specification
VECTRON