1/5
Measurement condition
Ambient temperature:
Input power level:
Terminating impedance:
Input:
23
0
°C
dBm
200
200
Ω
Ω
Output:
Characteristics
Remark:
The maximum attenuation in the pass band is defined as the insertion loss a . The nominal frequency fN is fixed at 312,5 MHz without any tolerance or
e
limit. The values of absolute attenuation a
are guaranteed for the whole operating temperature range. The frequency shift of the filter in the operating
abs
temperature range is included in the production tolerance scheme.
D a t a
typ. value
tolerance / limit
Insertion loss
a
2,2
dB
max.
4,5
dB
e
(reference level)
Nominal frequency
Pass band
fN
PB
-
-
312,5
1,5
MHz
MHz
fN
±
Bandwidth
BW
3
dB
7,36
MHz
dB
-
Absolute attenuation
a
abs
fN
-
300
MHz
…
fN
-
233
MHz
58
min.
52
dB
fN
fN
fN
fN
fN
fN
-
233
77
MHz
MHz
MHz
MHz
MHz
MHz
…
…
…
…
…
…
fN
fN
fN
fN
fN
fN
-
77
38
MHz
MHz
MHz
MHz
MHz
MHz
54
53
52
48
52
54
dB
dB
dB
dB
dB
dB
min.
min.
min.
min.
min.
min.
50
48
48
44
48
50
dB
dB
dB
dB
dB
dB
-
-
+
+
+
+
50
+
+
+
+
97
97
155
233
273
155
233
fN
+
273
MHz
…
fN
+
687,5
MHz
54
dB
min.
52
10
dB
Input power level
max.
dBm
Operating temperature range
Storage temperature range
OTR
-
-
- 40 °C ... + 85 °C
- 45 °C ... + 95 °C
Temperature coefficient of frequency
-32
ppm/K
TC
*
f
*) ∆f(Hz) = TC (ppm/K) x (T-T0) x f (MHz).
f
To
Generated:
Checked / Approved:
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: tft@telefilter.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 312.doc
Version 1.2
25.08.2006
VI TELEFILTER
Filter specification
TFS 312
2/5
Filter characteristic
0
-10
-20
-30
-40
-50
-60
-70
-80
-90
-100
0
-0.5
-1
-1.5
-2
-2.5
-3
-3.5
-4
-4.5
-5
100
200
300
400
500
600
700
800
900
1000
308
309
310
311
312
313
314
315
316
frequency in MHz
frequency in MHz
Construction and pin connection
(All dimensions in mm)
7
6
5
1
2
3
4
5
6
7
8
Ground
Input
Ground
Ground
Ground
Output
Ground
Ground
312
● U34
4
8
1
2
3
Date code
1
3
Date code: Year + week
6
U
V
2006
2007
2008
0
G
r
d
.
W
...
7
5
0,6
0,6
200 Ω Test circuit
L1
2
6
L2
SAW
1, 3, 4, 5, 7, 8
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: tft@telefilter.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 312.doc
Version 1.2
25.08.2006
VI TELEFILTER
Filter specification
TFS 312
3/5
Stability characteristics, reliability
After the following tests the filter shall meet the whole specification:
1. Shock:
500g, 1 ms, half sine wave, 3 shocks each plane;
DIN IEC 68 T2 - 27
2. Vibration:
10 Hz to 500 Hz, 0,35 mm or 5 g respectively, 1 octave per min, 10 cycles per plan, 3 plans;
DIN IEC 68 T2 - 6
3. Change of
temperature:
-55 °C to 125°C / 30 min. each / 10 cycles
DIN IEC 68 part 2 – 14 Test N
4. Resistance to
solder heat (reflow):
reflow possible: three times max.;
for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4;
This filter is RoHS compliant (2002/95/EG, 2005/618/EG)
Packing
Tape & Reel:
IEC 286 – 3, with exception of value for N and minimum bending radius;
tape type II, embossed carrier tape with top cover tape on the upper side;
max. pieces of filters per reel:
reel of empty components at start:
reel of empty components at start including leader:
trailer:
9000
min. 300 mm
min. 500 mm
min. 300 mm
Pull Off Direction
P1
Tape (all dimensions in mm)
Date Code
W
:
:
:
:
:
:
:
:
:
:
:
:
8,00 ± 0,3
4,00 ± 0,1
1,50 +0,1/-0
1,75 ± 0,1
3,50 ± 0,05
0,75
Po
P2
t
Do
Po
Do
E
F
G(min)
P2
P1
D1(min)
Ao
Bo
2,00 ± 0,05
4,00 ± 0,1
1,50
3,25 ± 0,1
3,25 ± 0,1
5,5 ± 0,1
Ko
Typ
PIN Marker
D1
Ao
Ct
W
2
Reel (all dimensions in mm)
A
W1
:330
: 8,4 +1,5/-0
W2(max) : 14,4
N(min)
C
: 50
: 13,0 +0,5/-0,2
C
A
N
W
1
The minimum bending radius is 45 mm.
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: tft@telefilter.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 312.doc
Version 1.2
25.08.2006
VI TELEFILTER
Filter specification
TFS 312
4/5
Air reflow temperature conditions
Conditions
Exposure
Average ramp-up rate (30°C to 217°C)
> 100°C
less than 3°C/second
between 300 and 600 seconds
> 150°C
> 217°C
Peak temperature
between 240 and 500 seconds
between 30 and 150 seconds
max. 260°C
Time within 5°C of actual peak temperature
Cool-down rate (Peak to 50°C)
Time from 30°C to Peak temperature
between 10 and 30 seconds
less than 6°C/second
no greater than 300 seconds
Chip-mount air reflow profile
Temperature / °C
max. 260°C
217°C
Time / s
max. 300 s
10 ... 30 s
30 ... 150 s
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: tft@telefilter.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 312.doc
Version 1.2
25.08.2006
VI TELEFILTER
Filter specification
TFS 312
5/5
History
Version
1.0
Reason of Changes
- Generation of development specification
Name
Date
Strehl
13.06.2006
04.07.2006
25.08.2006
1.1
- Add data aabs
Strehl
1.2
- Add pass band, change insertion loss
Channaa
- Change attenuation, add typical values
- Add filter characteristic, generation of filter specification
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: tft@telefilter.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
相关型号:
©2020 ICPDF网 联系我们和版权申明