F120-160 [TRIAD]
PC MOUNT : SPLIT PACK;型号: | F120-160 |
厂家: | TRIAD MAGNETICS |
描述: | PC MOUNT : SPLIT PACK PC |
文件: | 总1页 (文件大小:47K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
P O W E R T R A N S F O R M E R
P C M O U N T : SPLIT PACK
F120-010
Description:
The F120-010 is a single primary and dual secondary, split bobbin design which
operates with an input of 115V. The output voltage will be either 120.0V with a
center-tap under a 0.01A load with the secondaries wired in series, or 60.0V
under a 0.02A load with the secondaries wired in parallel. The split bobbin
design eliminates the need for costly electrostatic shielding.
Electrical Specifications (@25C)
1. Maximum Power: 1.1VA
2. Primary:
115V
3. Secondary: Series: 120.0V CT@ 0.01A
Parallel: 60.0V @ 0.02A
W
4. Voltage Regulation: 25% TYP @ full load to no load
5. Temperature Rise: 25C TYP
6. Hipot tested 100% at 2500 VRMS
Construction:
Three flange bobbin construction with primaries and secondaries wound side by
side for low capacitive coupling.
Agency File:
E
UL: File E53148, UL 5085-2 (506), Class B General Purpose Transformer,
cUL: File E53148, UL 5085-2 (506), Class B General Purpose Transformer,
Canadian Use (CSA 22.2, No.66.2-06)
L
Dimensions:
Units in inches.
H
H
W
L
A
B
C
D
E
F
0.937 1.125 1.375 0.250 0.250 1.200 0.041 0.020 0.234
Weight: 0.17 lbs
1
4
Schematic:
D
5
F
1
115V
50/60Hz
6
7
A
A
5
8
4
8
B
C
RoHS Compliance: As of manufacturing date February 2005, all standard products meet
the requirements of 2011/65/EU, known as the RoHS initiative.
As of April 7, 2008, UL standards 506 and 1585 will be migrated to UL 5085-2
and 5085-3, respectively.
1
4
0.06" DIAMETER
HOLE
* Upon printing, this document is considered “uncontrolled”. Please contact
Triad Magnetics’ website for the most current version.
Board Layout
Web: www.TriadMagnetics.com
Phone 951-277-0757
Fax 951-277-2757
460 Harley Knox Blvd.
Perris, California 92571
Publish Date: December 4, 2013
相关型号: