LTA065B0D0F [TOSHIBA]
LCD DOT MATRIX GRAPHIC DISPLAY MODULE;型号: | LTA065B0D0F |
厂家: | TOSHIBA |
描述: | LCD DOT MATRIX GRAPHIC DISPLAY MODULE CD |
文件: | 总10页 (文件大小:247K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
17cm COLOUR TFT-LCD MODULE
(6.5 TYPE)
Toshiba Matsushita Display Technology Co., Ltd
LTA065B0D0F
(a-Si TFT)
PRODUCT INFORMATION
All information is subject to change without notice. Please read bottom notes.
FEATURES:(1)6.5” VGA color display with High Luminance (400cd/m2)
(2)Wide Viewing Angle (Vertical:120°, Horizontal:140°)
(3)Built in Long Life Lamps (MTBF:30,000 h)
TENTATIVE
(Condition; Ta=25°C, IFL=6.0mA(rms)(continuous lighting))
(4)Replaceable structure of lamp units
(5)RoHS compatible
RoHS compatible
MECHANICAL SPECIFICATIONS
Item
Dimensional Outline (typ.)
Number of Pixels
Active Area
Pixel Pitch
Weight (approximately)
Backlight
Specifications
153.0 (W) x 118.0 (H) x 11.0 max(D) mm
640
(W) x 480 (H) pixels
132.48 (W) x 99.36 (H) mm
0.207 (W) x 0.207 (H)
250g
Sidelight ( 2 CCFLs )
ABSOLUTE MAXIMUM RATINGS
Item
Min.
-0.3
0
Max.
4.0
2.0
100
VDD+0.3
70
Unit
V
kV(rms)
kHz
V
(VDD
(VFL)
(fFL)
(VIN)
)
Supply Voltage
FL Driving Frequency
Input Signal Voltage
Operating Temperature *1
Storage Temperature
Storage Humidity
---
-0.3
-10
-20
°C
°C
80
10
90
%(RH)
(Max. wet bulb temperature = 39°C)
*1 : Only operation is guarantied at Operating Temperature. Display quality is evaluated at +25°C.
ELECTRICAL SPECIFICATION (Ta=25°C) (RECOMMENDED OPERATION CONDITION)
Item
Min.
3.0
Typ.
3.3
315
---
---
---
120
6.0
4.2
Max.
3.6
Unit
V
Remarks
(VDD
)
Supply Voltage
FL Start Voltage
(VFL)
(VSFL
(VIH)
---
---
V(rms)
V(rms)
V
V
mA
IFL =6.0mA(rms)
Ta=-10°C
)
1000
0.7 VDD
0
---
4.0
1900
VDD
0.3 VDD
---
6.5
---
High Level Input Voltage
Low Level Input Voltage
(VIL)
(IDD) *2
(IFL) *3
Current Consumption
mA(rms)
W
Power Consumption *2 *3
---
IFL =6.0mA(rms)
*2 : 8 color bars pattern *3 : Except the efficiency of FL inverter
OPTICAL SPECIFICATION (Ta=25°C)
Item
Min.
250
---
Typ.
500
120
Max.
---
---
Unit
---
°
Remarks
Contrast Ratio
Viewing Angle
(CR ≥ 10)
(CR)
(Upper+Lower)
(Left+Right)
---
140
---
°
(TON
(TOFF
)
)
---
---
320
200
15
25
400
250
30,000
50,000
---
---
---
---
ms
ms
cd/m2
cd/m2
h
Response Time
Luminance
IFL=6.0mA(rms)
IFL=4.0mA(rms)
IFL=6.0mA(rms)
IFL=4.0mA(rms)
(L)
Lamp Life Time (MTBF) *4 *5
h
*4 : Conditions ;Ta=25°C, continuous lighting
*5 : Definitions of failure ; 1) Lcd luminance becomes half of the minimum value. 2) Lamp doesn’t light normally.
*The information contained herein is presented only as a guide for the applications of our products. No responsibility is assumed by
Toshiba Matsushita Display Technology or other rights of the third parties which may result from its use. No license is granted by
implication or otherwise under any patent or patent rights of Toshiba Matsushita Display Technology or others.
*The information contained herein may be changed without prior notice. It is therefore advisable to contact Toshiba Matsushita Display
Technology before proceeding with the design of equipment incorporating this product.
(1/10)
2007-07-06 (Ver.0.9R)
LTA065B0D0F
Unit : mm
Standard tolerance : +/-0.5
DIMENSIONAL OUTLINE
TENTATIVE
<Front side>
59 +/-0.3
29.5 +/-0.3
(58.6)
8.92
6.42
99.36 (Active area)
105.58
118
59 +/-0.3
29.5 +/-0.3
(2/10)
2007-07-06 (Ver.0.9R)
LTA065B0D0F
<Rear side>
Unit : mm
Standard tolerance : +/-0.5
TENTATIVE
57.5 +/-0.5
31.5 +/-0.5
82 +/-0.3
13.6 +/-0.3
(3/10)
2007-07-06 (Ver.0.9R)
LTA065B0D0F
BLOCK DIAGRAM
CCFL Backlight
CCFL Backlight
CN3
DC/DC
Converter
LCD Panel
640 x 480 pixels
Gray Scale
Manipulation
Voltage
Generation
Circuit
CN1
CN2
Panel
X-Driver IC
Controller
Display Reverse
Signals (2bit)
640 pixels
X,1
X,2
640,1
640,2
1,1
1,2
1,Y
X,Y
640,Y
480 pixels
1,480
X,480
640,480
SEQUENCE OF POWER SUPPLIES AND SIGNALS
10ms(max.)
100ms(max.)
0.1ms(min.)
500ms(min.)
0.5ms(min.)
3.0V
3.0V
V DD
40ms(max.)
0ms(min.)
40ms(max.)
0ms(min.)
0.2V
0.2V
0.2V
NCLK
DE
0.2VDD
250ms(min.)
0.2VDD
DATA
H,V-sync
UD,RL
3s(min.)
0ms(min.)
VSFL
VFL
FL Input Voltage
V
10%
SFL
V
10%
FL
(4/10)
2007-07-06 (Ver.0.9R)
LTA065B0D0F
TIMING CHART
<H-Sync/V-Sync+DE Mode>
(5/10)
2007-07-06 (Ver.0.9R)
LTA065B0D0F
<DE-Only Mode>
(6/10)
2007-07-06 (Ver.0.9R)
LTA065B0D0F
TIMING SPECIFICATION 1) 2) 3) 4) 5)
<H-Sync/V-Sync+DE Mode>
Item
Symbol
min.
500
---
20
2
typ.
525
16.67
45
Max.
550
17.85
70
unit
th
ms
th
th
Frame Period
tv
Vertical blanking Term
V-sync Pulse Width
tvblnk
tvw
---
---
Vertical Front Porch
Vertical Data Sync Period
Vertical Display Term
tvfp
tvds
tvde
2
6
480
740
31.5
8
---
---
---
---
480
860
---
---
---
---
640
---
th
th
th
tc
us
tc
tc
tc
480
800
31.75
160
---
Horizontal Period
th
H-sync Pulse Width
Horizontal Front Porch
Horizontal Data Sync Period
Horizontal Display Term
Clock Period
Clock “L” Time
Clock “H” Time
Data Setup Time
Data Hold Time
thw
thfp
thds
thde
tc
8
8
---
640
35.0
10.0
10.0
5.0
10.0
640
39.7
---
---
---
tc
ns
ns
ns
ns
ns
tcl
---
---
---
---
tch
tds
tdh
---
<DE-Only Mode>
Item
Symbol
min.
500Xt3
---
480Xt3
740Xt5
31.5
640Xt5
35.0
10.0
typ.
525Xt3
16.67
480Xt3
800Xt5
31.75
640Xt5
39.7
Max.
550Xt3
17.85
480Xt3
860Xt5
---
unit
---
ms
---
---
Frame Period
t1
t2
t3
Vertical Display Term
One Line Scanning Term
us
---
Horizontal Display Term
Clock Period
Clock “L” Time
Clock “H” Time
Data Setup Time
Data Hold Time
t4
t5
t6
t7
t8
t9
640Xt5
---
ns
ns
ns
ns
ns
---
---
---
---
---
---
---
---
10.0
5.0
10.0
Note 1) If NCLK is fixed to "H" or "L" level for certain period while DE is supplied, the panel may be damaged.
Note 2) Please adjust LCD operating signal timing and FL driving frequency, to optimize the display quality.
There is a possibility that flicker is observed by the interference of LCD operating signal timing and FL driving condition
(especially driving frequency), even if the condition satisfies above timing specifications and recommended operating
conditions.
Note3 ) Do not make tv(t1), th(t2) and tvds(t3) fluctuate.
Note4) In case of using the long frame period, the deterioration of display quality, noise etc. may be occurred.
Note5) NCLK count of each Horizontal Scanning Time should be always the same.
V-Blanking period should be “n” X “Horizontal Scanning Time”. (n: integer)
Frame period should be always the same.
(7/10)
2007-07-06 (Ver.0.9R)
LTA065B0D0F
CONNECTOR PIN ASSIGNMENT FOR INTERFACE
CN1 INPUT SIGNAL
Connector : DF19L-30P-1H (56)/ HIROSE ELECTRIC CO., LTD.
Mating Connector : DF19G-30S-1C(Plug), DF19-2830SCFA(Crimp contact)
Terminal No.
Symbol
GND
NCLK
H-Sync
V-Sync
GND
R0 1)
R1 1)
R2 1)
R3 1)
R4 1)
R5 1)
GND
G0 1)
G1 1)
G2 1)
G3 1)
G4 1)
G5 1)
GND
B0 1)
B1 1)
B2 1)
B3 1)
B4 1)
B5 1)
DE
Function
1
2
3
4
5
6
7
8
SAMPLING CLOCK
HORIZONTAL SYNC.
VERTICAL SYNC.
RED DISPLAY DATA (LSB)
RED DISPLAY DATA
RED DISPLAY DATA
RED DISPLAY DATA
RED DISPLAY DATA
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
RED DISPLAY DATA (MSB)
GREEN DISPLAY DATA (LSB)
GREEN DISPLAY DATA
GREEN DISPLAY DATA
GREEN DISPLAY DATA
GREEN DISPLAY DATA
GREEN DISPLAY DATA (MSB)
BLUE DISPLAY DATA (LSB)
BLUE DISPLAY DATA
BLUE DISPLAY DATA
BLUE DISPLAY DATA
BLUE DISPLAY DATA
BLUE DISPLAY DATA (MSB)
DATA ENABLE
GND
VDD
VDD
GND
+3.3V POWER SUPPLY
+3.3V POWER SUPPLY
Note 1) See next page.
CN2 INPUT SIGNAL
Connector : DF14H-2P-1.25H(56) / HIROSE ELECTRIC CO., LTD.
Mating Connector : DF14-2S-1.25C(Socket), DF14-2628SCFA(Contact)
Terminal No.
Symbol
U D
R L
Function
1
2
VERTICAL REVERSE(“L” level or Open ; normal, ”H” level ; reverse)
HORIZONTAL REVERSE (“L” level or Open ; normal , ”H” level ; reverse)
CN3 CCFL POWER SOURCE
Connector : BHR-03(4-3)VS-1N / JAPAN SOLDERLESS TERMINAL MFG CO., LTD.
Mating Connector3) : SM04(4.0)B-BHS-1-TB(LF)(SN) / JAPAN SOLDERLESS TERMINAL MFG CO., LTD.
Terminal No.
Symbol
VFLH1
VFLH2
NC 2)
VFLL
Function
1
2
CCFL Power Supply ( high voltage)
CCFL Power Supply ( high voltage)
3
4
Non Connection (open)
CCFL Power Supply (low voltage)
Note 2) NC terminal should be open.
Note 3) Take away terminal No.3 of the mating connector. If does not take away, it may cause smoke burn of
electrical parts by high voltage.
(8/10)
2007-07-06 (Ver.0.9R)
LTA065B0D0F
256k (k=1024) COLORS COMBINATION TABLE
Gray Scale
Level
---
R5 R4 R3 R2 R1 R0 G5 G4 G3 G2 G1 G0 B5 B4 B3 B2 B1 B0
Display
L
L
L
L
H
H
H
H
L
L
L
L
L
L
L
H
H
H
H
L
L
L
L
L
L
L
H
H
H
H
L
L
L
L
L
L
L
H
H
H
H
L
L
L
L
L
L
L
H
H
H
H
L
L
H
L
L
L
L
H
H
H
H
L
H
L
L
L
H
H
L
L
H
H
L
L
L
L
L
H
H
L
L
H
H
L
L
L
L
L
H
H
L
L
H
H
L
L
L
L
L
H
H
L
L
H
H
L
L
L
L
L
H
H
L
L
H
H
L
L
L
L
L
H
H
L
L
H
H
L
L
L
L
H
L
H
L
H
L
H
L
L
L
L
H
L
H
L
H
L
H
L
L
L
L
H
L
H
L
H
L
H
L
L
L
L
H
L
H
L
H
L
H
L
L
L
L
H
L
H
L
H
L
H
L
L
L
L
H
L
H
L
H
L
H
L
L
L
Black
Blue
Green
Light Blue
Red
Purple
Yellow
White
Black
---
---
---
---
---
---
---
L 0
Basic
Color
L 1
L 2
Dark
↑
↓
Light
Gray
Scale of
Red
:
:
:
:
:
:
L3…
L60
H
H
H
H
H
H
H
H
H
H
H
H
L
H
H
H
L
H
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L61
L62
Red
L63
Red
Black
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L 0
L 1
L 2
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
H
H
L
L
L
L
L
L
L
L
L
L
L
L
L
Dark
↑
↓
Light
Gray
Scale of
Green
:
:
:
:
:
:
L3…
L60
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
H
H
H
H
H
H
H
H
H
H
H
H
L
H
H
H
L
H
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L61
L62
Green L63
Green
Black
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L 0
L 1
L 2
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
H
H
L
Dark
↑
↓
Light
Gray
Scale of
Blue
:
:
:
:
:
:
L3…
L60
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
H
H
H
H
H
H
H
H
H
H
H
H
L
H
H
H
L
H
L61
L62
Blue
L 0
L63
Blue
Black
L
L
L
L
L
L
L
L
L
L
L
L
L
L
H
L
H
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
H
L
H
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
H
L
H
L
L 1
L 2
Dark
↑
↓
Light
Gray
Scale of
White &
Black
:
:
:
:
:
:
L3…
L60
H
H
H
H
H
H
H
H
H
H
H
H
L
H
H
H
L
H
H
H
H
H
H
H
H
H
H
H
H
H
L
H
H
H
L
H
H
H
H
H
H
H
H
H
H
H
H
H
L
H
H
H
L
H
L61
L62
White L63
White
(9/10)
2007-07-06 (Ver.0.9R)
LTA065B0D0F
!
FOR SAFETY
LCD module is generally designed with precise parts to achieve light weighted thin mechanical dimensions.
In using our Modules, make certain that you fully understand and put into practice the warnings and safety precautions detailed
in Engineering Information No.EE-N001,"CAUTIONS AND INSTRUCTIONS FOR TOSHIBA LCD MODULES".
Refer to individual specifications and TECHNICAL DATA sheets (hereinafter called "TD") for more detailed technical
information.
1) SPECIAL PURPOSES
A) Toshiba Matsushita Display Technology's Standard LCD Modules have not been customized for operation in extreme
environments or for use in applications where performance failures could be life-threatening or otherwise catastrophic.
B) Since Toshiba Matsushita Display Technology's Standard LCD Modules have not been designed for operation in extreme
environments, they must never be used in devices that will be exposed to abnormally high levels of vibration or shock which
exceed Toshiba Matsushita Display Technology's published specification limits.
C) In addition, since Toshiba Matsushita Display Technology Standard LCD Modules have not been designed for use in
applications where performance failures could be life-threatening or catastrophic, they must never be installed in aircraft
navigation control systems (such as, but not limited to Traffic Collision Avoidance System and Air Traffic Indicator), in military
defense or weapons systems, in critical industrial process-control systems (e.g., those involved in the production of nuclear
energy), or in critical medical device or patient life-support systems.
2) DISASSEMBLING OR MODIFICATION
DO NOT DISASSEMBLE OR MODIFY the module. It may damage sensitive parts inside LCD module, and may cause
scratches or dust on the display.
Toshiba Matsushita Display Technology doses not warrant the module, if customer disassembled or modified it.
3) BREAKAGE OF LCD PANEL
DO NOT INGEST liquid crystal material, DO NOT INHALE this material, and DO NOT CONTACT the material with skin, if LCD
panel is broken and liquid crystal material spills out.
If liquid crystal material comes into mouth or eyes, rinse mouth or eyes out with water immediately.
If this material contact with skin or cloths, wash it off immediately with alcohol and rinse thoroughly with water.
4) GLASS OF LCD PANEL
BE CAREFUL WITH CHIPS OF GLASS that may cause injuring fingers or skin, when the glass is broken.
5) ELECTRIC SHOCK
DISCONNECT POWER SUPPLY before handling LCD module.
DO NOT TOUCH the parts inside LCD module and the fluorescent lamp's connector or cables in order to prevent electric
shock, because high voltage is supplied to these parts from the inverter unit while power supply is turned on.
6) ABSOLUTE MAXIMUM RATINGS AND POWER PROTECTION CIRCUIT
DO NOT EXCEED the absolute maximum rating values under the worst probable conditions caused by the supply voltage
variation, input voltage variation, variation in parts' constants, environmental temperature, etc., otherwise LCD module may be
damaged.
Employ protection circuit for power supply, whenever the specification or TD specifies it.
Suitable protection circuit should be applied for each system design.
7) RECOMMENDED OPERATION CONDITIONS
The performance and quality of the LCD panel are warranted only when the LCD panel is used within “the recommended
operation conditions”. Toshiba Matsushita Display Technology Co., Ltd. never warrants the performance and quality of the
LCD panel when you use the LCD panel over “the recommended operation conditions”, although within “the absolute
maximum rating”.
To use the LCD panel over “the recommended operation conditions” may have bad influence on the characteristics and
reliability of the LCD panel and may shorten the life of the LCD panel.
Therefore, when designing the whole set, not to be over “the recommended operation conditions”, you should fully take care of
supply voltage change, characteristic of connection parts, serge of input-and-output line, and surrounding temperature.
8) DISPOSAL
When dispose LCD module, obey to the applicable environmental regulations.
(10/10)
2007-07-06 (Ver.0.9R)