Technical  
Specification  
SQ60120QPB33  
36-75V  
100V  
Transient Input  
12V  
Output  
396W  
Max Power  
2250V dc Quarter-brick  
Input  
Isolation  
DC-DC Converter  
The SQ60120QPB33 bus converter is a next-generation,  
board-mountable, isolated, fixed switching frequency dc-  
dc converter that uses synchronous rectification to achieve  
extremely high conversion efficiency. The SQ BusQor series  
provides an isolated step down voltage from 48V to a semi-  
regulated 12V intermediate bus. BusQor converters are  
ideal for customers who need multiple outputs and wish to  
build or buy point of load converters to work with a 12V rail.  
RoHS Compliant (see last page).  
Operational Features  
• High efficiency, 94.3% at full rated load current  
• Delivers up to 33A of output current (396W power)  
with minimal derating  
SQ60120QPB33 Model  
• Wide input voltage range: 36-75V, with  
100V 100ms input voltage transient capability  
• Fixed frequency switching provides predictable EMI performance  
• No minimun load requirement  
Protection Features  
• Input under-voltage lockout and over-voltage shutdown protects  
against abnormal input voltages  
utput current limit and short circuit protection  
utput over-voltage protection  
hermal shutdown  
Mechanical Features  
• Industry standard quarter-brick pin-out configuration  
• Industry standard size: 2.30" x 1.45" (58.4 x 36.8mm)  
Total height: 0.50" (12.7mm)  
Total weight: 2.2 oz (62 g)  
Control Features  
• On/Off control referenced to input side  
• Inherent current share (by droop method) for high current and  
parallel applications.  
Contents  
Page No.  
Safety Features  
• UL 60950-1:2007  
• EN60950-1/A11:2009/A1:2010  
• CAN/CSA-C22.2 No. 60950-1:2007  
• IEC 61000-4-2  
Baseplated Mechanical. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2  
Electrical Characteristics. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3  
Standards & Qualifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5  
Figures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6  
Application Section . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10  
Ordering Information. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14  
Product # SQ60120QPB33  
Phone 1-888-567-9596  
www.synqor
Technical  
Specification  
SQ60120QPB33  
Baseplated Mechanical  
TOP VIEW  
1.45[36,8]  
SIDE VIEW  
.600[15,24]  
M3x.5  
THREADED HOLE  
x3  
.500 ± .034  
[12,70 ± 0,86]  
OVERALL HEIGHT  
6
SEE NOTES 1 & 2  
5
.145  
[3,68]  
SEE NOTE 5  
2.30  
[58,4]  
1.860  
[47,24]  
2.00  
[50,8]  
.14  
[3,6]  
2
1
3
.033± .032  
.160[4,06]  
1.130[28,7]  
[ 0,84± 0,81]  
BOTTOMSIDE  
CLEARANCE  
.43[10,8]  
.300[7,62]  
.600[15,24]  
.220  
[5,59]  
NOTES  
PIN DESIGNATIONS  
1)  
M3 screws used to bolt unit's baseplate to other surfaces  
such as heastsink must not exceed 0.10" (2.54mm)  
depth below the surface of the baseplate.  
Pin  
Name  
Function  
1
2
3
5
6
Vin(+)  
ON/OFF  
Vin(–)  
Vout(–)  
Vout(+)  
Positive input voltage  
Logic control input to turn converter on/off  
Negative input  
Negative output  
Positive output  
2)  
3)  
Applied torque per screw should not exceed 6in-lb (0.7nm)  
Pins 1-3 are 0.040" (1.02mm) Dia. with 0.080" (2.03mm) dia.  
standoff shoulders  
Pins 5-6 are 0.062" (1.57mm) Dia. with 0.100" (2.54mm) Dia.  
standoff shoulders  
4)  
5)  
6)  
Other pin extension lengths available  
All Pins: Material - Copper Alloy  
Finish: Matte Tin over Nickel plate  
7)  
8)  
9)  
Baseplate flatness tolerance is 0.004" (.10mm) TIR for surface.  
Undimensioned components are shown for visual reference only  
Weight: 2.2 oz (62 g)  
All dimensions in inches (mm)  
10)  
Tolerances: x.xx +/-0.02 in. (x.x +/-0.5mm)  
x.xxx +/-0.010 in. (x.xx +/-0.25mm)  
Product # SQ60120QPB33  
Phone 1-888-567-9596  
www.synqor.com  
Doc.# 005-0005266 Rev. F  
03/29/11  
Page 2  
Input: 36-75V  
Output: 12V  
Current: 33A  
Package: Quarter-brick  
Technical Specification  
SQ60120QPB33 Electrical Characteristics  
Ta = 25°C, airflow rate = 300 LFM, Vin = 48Vdc unless otherwise noted; full operating temperature range is -40°C to +100°C ambient temperature with  
appropriate power derating. Specifications subject to change without notice.  
Parameter  
ABSOLUTE MAXIMUM RATINGS  
Min.  
Typ.  
Max. Units Notes & Conditions  
Input Voltage  
Non-Operating  
Operating  
Operating Transient Protection  
Isolation Voltage  
0
36  
100  
75  
100  
V
V
V
Continuous  
Continuous  
100 ms transient, square wave  
48  
Input to Output  
Operating Temperature  
Storage Temperature  
2250  
100  
125  
18  
V
°C  
°C  
V
-40  
-55  
-2  
Voltage at ON/OFF input pin  
INPUT CHARACTERISTICS  
Operating Input Voltage Range  
Input Under-Voltage Lockout  
Turn-On Voltage Threshold  
Turn-Off Voltage Threshold  
Lockout Voltage Hysteresis  
Input Over-Voltage Shutdown  
Turn-On Voltage Threshold  
Turn-Off Voltage Threshold  
Maximum Input Current  
No-Load Input Current  
36  
48  
75  
V
31.0  
27.6  
2
34.5  
32  
4
V
V
V
95  
105  
V
V
A
mA  
mA  
mA  
mA  
A
12.9  
130  
8.5  
20  
800.0  
15  
Disabled Input Current  
Input Reflected-Ripple Current  
Input Terminal-Ripple Current  
Recommended Input Fuse (see Note 1)  
Recommended External Input Capacitance  
Input Filter Component Values (L\C)  
OUTPUT CHARACTERISTICS  
Output Voltage Set Point  
Output Voltage Regulation  
Over Line  
Over Load  
Over Temperature  
Total Output Voltage Range  
Output Voltage Ripple and Noise  
Peak-to-Peak  
10  
400.0  
RMS through 10µH inductor  
RMS, full load  
Fast blow external fuse recommended  
Typical ESR 0.1-0.2 Ω  
47  
0.47\6.6  
µF  
µH\µF Internal values; see Figure E  
12.46  
12.5  
12.54  
V
Vin = 65 V, Io = 0 A, Ta = 25 °C  
'+0.18\-1.25  
+0\-0.80  
±300  
V
V
mV  
V
10.250  
0
12.830  
Over sample, line, load, temperature & life  
20 MHz bandwidth; see Note 2  
Full load  
Full load  
Subject to thermal derating  
Output voltage 10% Low  
200  
50  
325  
115  
33  
mV  
mV  
A
RMS  
Operating Output Current Range  
Output DC Current-Limit Inception  
Output DC Current-Limit Shutdown Voltage  
Back-Drive Current Limit while Disabled  
Maximum Output Capacitance  
DYNAMIC CHARACTERISTICS  
Output Voltage during Load Current Transient  
Step Change in Output Current (0.1 A/µs)  
Settling Time  
40  
10.5  
50  
A
V
mA  
µF  
Negative current drawn from output  
Vout nominal at full load (resistive load)  
3,000  
1600  
250  
2,500  
350  
mV  
µs  
50% to 75% to 50% Iout max  
To within 1% Vout nom  
Turn-On Transient  
Turn-On Time  
Start-Up Inhibit Time  
Output Voltage Overshoot  
15  
200  
0
30  
ms  
ms  
%
Full load, Vout=90% nom.  
-40 °C to +125 °C; Figure F  
3 mF load capacitance  
Product # SQ60120QPB33  
Phone 1-888-567-9596  
www.synqor.com  
Doc.# 005-0005266 Rev. F  
03/29/11  
Page 3  
Input: 36-75V  
Output: 12V  
Current: 33A  
Package: Quarter-brick  
Technical Specification  
SQ60120QPB33 Electrical Characteristics (continued)  
Ta = 25°C, airflow rate = 300 LFM, Vin = 48Vdc unless otherwise noted; full operating temperature range is -40°C to +100°C ambient temperature with  
appropriate power derating. Specifications subject to change without notice.  
Parameter  
Min.  
Typ.  
Max. Units Notes & Conditions  
ISOLATION CHARACTERISTICS  
Isolation Voltage (dielectric strength)  
Isolation Resistance  
V
MΩ  
pF  
See Absolute Maximum Ratings  
See Note 3  
2250  
30  
470  
Isolation Capacitance (input to output)  
TEMPERATURE LIMITS FOR POWER DERATING CURVES  
Semiconductor Junction Temperature  
Board Temperature  
Transformer Temperature  
EFFICIENCY  
125  
125  
125  
°C  
°C  
°C  
Package rated to 150 °C  
UL rated max operating temp 130 °C  
100% Load  
50% Load  
94.3  
94.8  
%
%
FEATURE CHARACTERISTICS  
Switching Frequency  
212  
250  
288  
kHz  
ON/OFF Control (Option P)  
Off-State Voltage  
On-State Voltage  
-1  
2.4  
0.8  
18  
V
V
ON/OFF Controll (Option N)  
Off-State Voltage  
On-State Voltage  
2.4  
-1  
18  
0.8  
V
V
ON/OFF Control (Either Option)  
Pull-Up Voltage  
Pull-Up Resistance  
Output Over-Voltage Protection  
Over-Temperature Shutdown OTP Trip Point  
Over-Temperature Shutdown Restart Hysteresis  
RELIABILITY CHARACTERISTICS  
Calculated MTBF (Telcordia) TR-NWT-000332  
Calculated MTBF (MIL-217) MIL-HDBK-217F  
Field Demonstrated MTBF  
Application notes Figures A & B  
5.0  
124  
16  
V
kΩ  
V
°C  
°C  
Over full temp range; no load  
Average PCB Temperature  
140  
150  
10  
2.6  
2.1  
TBD  
106 Hrs. 80% load, 200LFM, 40 °C Ta  
106 Hrs. 80% load, 200LFM, 40 °C Ta  
106 Hrs. See our website for details  
Note 1: UL’s product certification tests were carried out using 15A fast blow fuse. Fuse interruption characteristics have to be taken into account  
while designing input traces. User should ensure that Input trace is capable of withstanding fault currents  
Note 2: For applications requiring reduced output voltage ripple and noise, consult SynQor applications support (e-mail: support@synqor.com)  
Note 3: Isolation capacitance can be added external to the module.  
Product # SQ60120QPB33  
Phone 1-888-567-9596  
www.synqor.com  
Doc.# 005-0005266 Rev. F  
03/29/11  
Page 4  
Input: 36-75V  
Output: 12V  
Current: 33A  
Package: Quarter-brick  
Technical Specification  
Standards Compliance & Qualification Testing  
Parameter  
STANDARDS COMPLIANCE  
Notes & Conditions  
UL 60950-1:2007  
Basic insulation  
EN60950-1/A11:2009/A1:2010  
CAN/CSA-C22.2 No. 60950-1:2007  
IEC 61000-4-2  
ESD test, 8 kV - NP, 15 kV air - NP (Normal Performance)  
Note: An external input fuse must always be used to meet these safety requirements. Contact SynQor for official safety certificates on new  
releases or download from the SynQor website.  
Parameter  
# Units Test Conditions  
QUALIFICATION TESTING  
Life Test  
32  
95% rated Vin and load, units at derating point, 1000 hours  
Vibration  
5
5
10  
5
5
5
10-55 Hz sweep, 0.060" total excursion, 1 min./sweep, 120 sweeps for 3 axis  
100g minimum, 2 drops in x, y and z axis  
Mechanical Shock  
Temperature Cycling  
Power/Thermal Cycling  
Design Marginality  
Humidity  
-40 °C to 100 °C, unit temp. ramp 15 °C/min., 500 cycles  
Toperating = min to max, Vin = min to max, full load, 100 cycles  
Tmin-10 °C to Tmax+10 °C, 5 °C steps, Vin = min to max, 0-105% load  
85 °C, 85% RH, 1000 hours, continuous Vin applied except 5 min/day  
MIL-STD-883, method 2003  
Solderability  
15 pins  
Product # SQ60120QPB33  
Phone 1-888-567-9596  
www.synqor.com  
Doc.# 005-0005266 Rev. F  
03/29/11  
Page 5  
Input: 36-75V  
Output: 12V  
Current: 33A  
Package: Quarter-brick  
Technical Specification  
100  
95  
90  
85  
80  
75  
70  
30  
25  
20  
15  
10  
5
36 Vin  
48 Vin  
75 Vin  
36 Vin  
48 Vin  
75 Vin  
0
0
3
6
9
12  
15  
18  
21  
24  
27  
30  
33  
0
3
6
9
12  
15  
18  
21  
24  
27  
30  
33  
Load Current (A)  
Load Current (A)  
Figure 1: Efficiency at nominal output voltage vs. load current for minimum,  
nominal, and maximum input voltage at 25 °C.  
Figure 2: Power dissipation at nominal output voltage vs. load current for  
minimum, nominal, and maximum input voltage at 25 °C.  
96.0  
95.5  
95.0  
94.5  
20  
19  
18  
17  
16  
15  
14  
13  
94.0  
25º C  
25º C  
12  
40º C  
40º C  
93.5  
55º C  
55º C  
11  
10  
93.0  
100  
200  
300  
400  
100  
200  
300  
400  
Air Flow (LFM)  
Air Flow (LFM)  
Figure 3: Efficiency at nominal output voltage and 60 % rated power vs. airflow  
rate for ambient air temperatures of 25, 40, and 55 °C (nominal input voltage).  
Figure 4: Power dissipation at nominal output voltage and 60 % rated power  
vs. airflow rate for ambient air temperatures of 25, 40, and 55 °C (nominal input  
voltage).  
40  
30  
400  
350  
300  
250  
200  
20  
150  
400 LFM (2.0 m/s)  
400 LFM (2.0 m/s)  
300 LFM (1.5 m/s)  
300 LFM (1.5 m/s)  
10  
100  
200 LFM (1.0 m/s)  
100 LFM (0.5 m/s)  
200 LFM (1.0 m/s)  
100 LFM (0.5 m/s)  
50  
0
0
25  
40  
50  
60  
70  
85  
25  
40  
50  
60  
70  
85  
Ambient Air Temperature (ºC)  
Ambient Air Temperature (ºC)  
Figure 5: Maximum output current derating curves vs. ambient air temperature  
for airflow rates of 100 LFM through 400 LFM with air flowing from pin 3 to pin  
1 (nominal input voltage).  
Figure 6: Maximum output power derating curves vs. ambient air temperature  
for airflow rates of 100 LFM through 400 LFM with air flowing from pin 3 to pin  
1 (nominal input voltage).  
Product # SQ60120QPB33  
Phone 1-888-567-9596  
www.synqor.com  
Doc.# 005-0005266 Rev. F  
03/29/11  
Page 6  
Input: 36-75V  
Output: 12V  
Current: 33A  
Package: Quarter-brick  
Technical Specification  
40  
400  
350  
300  
250  
200  
150  
100  
50  
30  
20  
400 LFM (2.0 m/s)  
400 LFM (2.0 m/s)  
300 LFM (1.5 m/s)  
300 LFM (1.5 m/s)  
200 LFM (1.0 m/s)  
100 LFM (0.5 m/s)  
10  
200 LFM (1.0 m/s)  
100 LFM (0.5 m/s)  
0
0
25  
40  
50  
60  
70  
85  
25  
40  
50  
60  
70  
85  
Ambient Air Temperature (ºC)  
Ambient Air Temperature (ºC)  
Figure 7: Maximum output current derating curves vs. ambient air temperature  
for airflow rates of 100 LFM through 400 LFM with air flowing from input to  
output (nominal input voltage).  
Figure 8: Maximum output power derating curves vs. ambient air temperature  
for airflow rates of 100 LFM through 400 LFM with air flowing from input to  
output (nominal input voltage).  
Figure 9: Turn-on transient at half load (resistive load) and 3mF output  
capacitance (5 ms/div). Input voltage pre-applied. Ch 1: Vout (5V/div). Ch 2:  
ON/OFF input (2 V/div).  
Figure 10: Turn-on transient at zero load and 3mF output capacitance (5 ms/  
div). Input voltage pre-applied. Ch 1: Vout (5V/div). Ch 2: ON/OFF input (2 V/  
div).  
Figure 11: Output voltage response to step-change in load current (50%-75%-  
50% of Iout(max); dI/dt = 0.1A/µs). Load cap: 100µF, electrolytic cap, 15uF  
tantalum cap, and 1µF ceramic cap. Ch 1: Vout (2V/div), Ch 2: Iout (10A/div).  
Product # SQ60120QPB33  
Phone 1-888-567-9596  
www.synqor.com  
Doc.# 005-0005266 Rev. F  
03/29/11  
Page 7  
Input: 36-75V  
Output: 12V  
Current: 33A  
Package: Quarter-brick  
Technical Specification  
Input  
Reflected  
Ripple  
Input  
Terminal  
Ripple  
Output  
Voltage  
Ripple  
Current  
Current  
source  
impedance  
iS  
iC  
DC-DC  
Converter  
V
OUT  
V
SOURCE  
electrolytic  
capacitor  
ceramic electrolytic  
capacitor capacitor  
Figure 12: Test set-up diagram showing measurement points for Input Terminal  
Ripple Current (Figure 13), Input Reflected Ripple Current (Figure 14), and  
Output Voltage Ripple (Figure 15).  
Figure 13: Input Terminal Ripple Current, ic, at full rated output current and  
nominal input voltage with 10µH source impedance and 47µF electrolytic  
capacitor (500 mA/div). See Figure 12.  
Figure 14: Input reflected ripple current, is, through a 10 µH source inductor,  
using a 47µF electrolytic input capacitor (20mA/div). See Figure 12.  
Figure 15: Output voltage ripple at nominal input voltage and rated load current  
(100 mV/div). Load capacitance: 1µF ceramic capacitor and 15µF tantalum  
capacitor. Bandwidth: 20 MHz. See Figure 12.  
14  
12  
10  
8
6
4
36 Vin  
48 Vin  
2
75 Vin  
0
0
10  
20  
30  
40  
50  
60  
70  
Load Current (A)  
Figure 16: Output voltage vs. load current showing typical current limit curves  
and converter shutdown points.  
Figure 17: Load current (25A/div) as a function of time when the converter  
attempts to turn on into a 1 mΩ short circuit. Top trace (500us/div) is an  
expansion of the on-time portion of the bottom trace  
Product # SQ60120QPB33  
Phone 1-888-567-9596  
www.synqor.com  
Doc.# 005-0005266 Rev. F  
03/29/11  
Page 8  
Input: 36-75V  
Output: 12V  
Current: 33A  
Package: Quarter-brick  
Technical Specification  
1
0
-5  
-10  
-15  
-20  
-25  
-30  
-35  
-40  
-45  
-50  
-55  
-60  
0.1  
36 Vin  
48 Vin  
75 Vin  
36 Vin  
48 Vin  
75 Vin  
0.01  
10  
100  
1,000  
Hz  
10,000  
100,000  
10  
100  
1,000  
Hz  
10,000  
100,000  
Figure 18: Magnitude of incremental output impedance (Zout = Vout/Iout) for  
minimum, nominal, and maximum input voltage at full rated power.  
Figure 19: Magnitude of incremental forward transmission (FT = Vout/Vin) for  
minimum, nominal, and maximum input voltage at full rated power.  
1000  
100  
10  
0
-10  
-20  
36 Vin  
1
-30  
36 Vin  
48 Vin  
48 Vin  
75 Vin  
75 Vin  
-40  
0.1  
10  
100  
1,000  
Hz  
10,000  
100,000  
10  
100  
1,000  
Hz  
10,000  
100,000  
Figure 20: Magnitude of incremental reverse transmission (RT = Iin/Iout) for  
minimum, nominal, and maximum input voltage at full rated power.  
Figure 21: Magnitude of incremental input impedance (Zin = Vin/Iin) for  
minimum, nominal, and maximum input voltage at full rated power.  
Product # SQ60120QPB33  
Phone 1-888-567-9596  
www.synqor.com  
Doc.# 005-0005266 Rev. F  
03/29/11  
Page 9  
Technical  
Specification  
SQ60120QPB33  
Application Section  
BASIC OPERATION AND FEATURES  
CONTROL FEATURES  
With voltages dropping and currents rising, the economics  
of an Intermediate Bus Architecture (IBA) are becoming  
more attractive, especially in systems requiring multiple  
low voltages. IBA systems separate the role of isolation and  
voltage scaling from regulation and sensing. The BusQor  
series bus converter provides isolation and a coarse voltage  
step down in one compact module, leaving regulation to  
simpler, less expensive non-isolated converters.  
REMOTE ON/OFF (Pin 2): The ON/OFF input, Pin 2,  
permits the user to control when the converter is on or off.  
This input is referenced to the return terminal of the input  
bus, Vin(-). There are two versions of the converter that  
differ by the sense of the logic used for the ON/OFF input.  
In the positive logic version, the ON/OFF input is active  
high (meaning that a high turns the converter on). In the  
negative logic version, the ON/OFF signal is active low  
(meaning that a low turns the converter on). Figure B is a  
detailed look of the internal ON/OFF circuitry.  
In Figure A below, the BusQor module provides the isolation  
stage of the IBA system. The isolated bus then distributes  
power to the non-isolated buck regulators to generate the  
required voltage levels at the point of load. In this case, the  
bucks are represented with SynQor’s NiQor series of non-  
isolated dc-dc converters. In many applications requiring  
multiple low voltage outputs, significant savings can be  
achieved in board space and overall system costs.  
When designing an IBA system with bus converters, the  
designer can select from a variety of bus voltages. While  
there is no universally ideal bus voltage, most designs  
employ one of the following: 12V, 9V, 7.5V, 5V, or 3.3V.  
Higher bus voltages can lead to lower efficiency for the buck  
regulators but are more efficient for the bus converter and  
provide lower board level distribution current. Lower bus  
voltages offer the opposite trade offs.  
SynQor’s SQ BusQor modules accept the full 48/60V  
telecom bus voltage and have a narrow output voltage  
range compatible with many non-isolated point of load  
converters. When used in IBA systems, the output variation  
of the BusQor must be in accordance with the input voltage  
range of the non-isolated converters being employed.  
3.3V  
48Vdc  
36-75V  
2.5V  
1.8V  
+5V  
5V  
12Vdc  
+
Vin( )  
BusQor  
Converter  
124k  
1.5V  
0.9V  
ON/OFF  
49.9k  
100k  
NiQor  
Converters  
Loads  
TTL  
Typical User Board  
48Vdc  
Front End  
Vin(_)  
Figure A: Example of Intermediate Bus Architecture using BusQor bus converter  
and NiQor non-isolated converters  
Figure B: Internal ON/OFF pin circuitry  
Product # SQ60120QPB33  
Phone 1-888-567-9596  
www.synqor.com  
Doc.# 005-0005266 Rev. F  
03/29/11  
Page 10  
Technical  
Specification  
SQ60120QPB33  
Application Section  
Output Short Circuit Protection: When the output of  
the BusQor module is shorted, a peak current of typically 55A  
will flow into the short circuit for a time of about 1ms. The  
output of the BusQor will shutdown to zero volts after the  
1ms have elapsed (Fig C & D). The shutdown period lasts  
for a time of 200ms, at the end of which the BusQor module  
tries to power up again. If the short circuit persists, the  
output voltage will go through repeated cycles of shutdown  
and restart with a duty cycle of 20ms (On) and 200ms (Off)  
respectively. The BusQor module returns (auto resetting)  
to normal operation once the short circuit is removed. The  
BusQor is designed to survive in this mode indefinitely  
without damage and without human intervention.  
Protection Features  
Input Under-Voltage Lockout: The converter is designed  
to turn off when the input voltage is too low, helping avoid  
an input system instability problem, described in more detail  
in the application note titled “Input System Instability”  
available on www.SynQor.com. The lockout circuitry is a  
comparator with DC hysteresis. When the input voltage is  
rising, it must exceed the typical Turn-On Voltage Threshold  
value (listed on the specification page) before the converter  
will turn on. Once the converter is on, the input voltage  
must fall below the typical Turn-Off Voltage Threshold value  
before the converter will turn off. Also see Fig E.  
Output Current Limit: The output of the BusQor module  
is electronically protected against output overloads. When  
an overload current greater than the “DC Current-Limit  
Inception” specification is drawn from the output, the  
output of the BusQor will shutdown to zero volts after the  
1ms have elapsed (see Fig C). The shutdown period lasts  
for a typical period of 200ms (Fig D) after which the BusQor  
tries to power up again. If the overload persists, the output  
voltage will go through repeated cycles of shutdown and  
restart with a duty cycle of 20ms (On) and 200ms (Off)  
respectively. The BusQor module returns (auto resetting)  
to normal operation once the overload is removed. The  
BusQor is designed to survive in this mode indefinitely  
without damage and without human intervention.  
In the Auto resetting mode, also referred to as “Hiccup”  
mode, the power drawn from the 48V input is about 5W,  
most of which is dissipated into the external fault. It is  
important that copper traces and pads from the output  
circuit be designed to withstand the short term peaks,  
although the average current into the fault may be as low  
as 50mA typical. See Fig 17 for appropriate waveform.  
Over-Temperature Shutdown: A temperature sensor  
on the converter senses the average temperature of the  
module. The thermal shutdown circuit is designed to turn  
the converter off when the temperature at the sensed  
location reaches the Over-Temperature Shutdown value.  
It will allow the converter to turn on again when the  
temperature of the sensed location falls by the amount of  
the Over-Temperature Shutdown Restart Hysteresis value.  
55A  
peak  
Output  
Current  
Output  
Current  
55A  
33A  
Output  
Voltage  
Output  
Voltage  
<12V  
12V  
Time  
0V  
0V  
Shutdown  
200ms  
Duty  
20ms  
1ms  
Time  
Figure C: Output Overload protection diagram (not to scale)  
Figure D: Output Short Circuit and Auto-Resetting protection diagram (not to scale)  
Product # SQ60120QPB33  
Phone 1-888-567-9596  
www.synqor.com  
Doc.# 005-0005266 Rev. F  
03/29/11  
Page 11  
Technical  
Specification  
SQ60120QPB33  
Application Section  
APPLICATION CONSIDERATIONS  
Vin  
Startup Inhibit Period: Figure E details the Start-Up  
Inhibit Period for the BusQor module when Vin is applied  
with the On/Off pin asserted (enabled). Before time t1,  
when the input voltage Off pin asserted (enabled). Before  
time t1, when the input voltage is below the UVL threshold,  
the unit is disabled by the Input Under-Voltage Lockout  
feature. When the input voltage rises above the UVL  
threshold, the Input Under-Voltage Lockout is released, and  
a typical Startup Inhibit Period of 8ms from a Vin start-up.  
Once the module recognizes it should be on it waits an  
additional 4ms before it starts. When starting from an on/  
off event the module has an inhibit time of 200ms like our  
standard products. The output builds up to 90% or higher  
of the nominal voltage and stabilizes to its nominal output  
voltage in a total time of 15ms typical.  
UVLO  
On/Off  
(N logic)  
OFF  
ON  
t0  
t1  
t2  
t3  
t
Vout  
12V  
12 ms  
200 ms  
At time t2, when the On/Off pin is de-asserted (disabled),  
the BusQor module stops switching immediately. Fall time  
from 12V to 0V is dependent on output capacitance load  
current, and any parasitic trace inductance in the output  
load circuit.  
Fault Inhibit  
Start-Up  
Time  
Start-up  
Inhibit  
15 ms  
At time t3, when the On/Off pin is re-asserted (enabled),  
the BusQor module output begins to build up after the  
inhibit period of 200ms typical.  
Figure E: Power Up/Down Diagram (not to scale) showing Start-Up Inhibit Period.  
Refer to the Control Features section of the data sheet for  
details on enabling and disabling methods for N and P logic  
type modules.  
Product # SQ60120QPB33  
Phone 1-888-567-9596  
www.synqor.com  
Doc.# 005-0005266 Rev. F  
03/29/11  
Page 12  
Technical  
Specification  
SQ60120QPB33  
Application Section  
Droop Current Sharing:  
This product has primary side regulation only. Primary side Temperature Mismatch Self Balancing: the slope of  
regulation results in a voltage droop as the load current the output voltage droop characteristic of semi regulated  
increase (droop characteristic). The inherent impedance module increases with increased temperature. Therefore,  
of the power stage due to its droop characteristic can be if a paralleled unit were hotter than its neighbor because it  
used to balance the load current between multiple modules is supplying more load current, then its output voltage will  
that are placed in parallel. The graphs in this section show droop further forcing the cooler module(s) to increase its  
two units by way of example, but there is no fundamental load current. The increase in effective output resistance  
limit to the number of units that can be placed in parallel. due to an increase in temperature acts as a self correcting  
mechanism (Fig G) when two or more modules are connected  
When multiple units having droop characteristics are placed in a parallel configuration.  
in parallel, the current sharing accuracy is determined by the  
output voltage set point accuracy relative to the total output  
voltage droop for a given load current range. A difference  
in voltage between two units will cause a differential current  
to flow out of one unit and into the other. Figure F shows an  
examplewithtwounitswithanoutputvoltagemismatchedby  
0.5%. In this example, when Unit A is at 100% of its full rated  
load current, Unit B is only at 90%, effectively reducing the  
total available current by 5%. SynQor uses factory calibration  
of each unit to ensure that output voltage is well matched.  
Droop Characteristics with Voltage Mismatch  
Droop Characteristics with Temperature Mismatch (Self Balancing)  
0.0%  
-0.5%  
-1.0%  
-1.5%  
-2.0%  
-2.5%  
-3.0%  
-3.5%  
-4.0%  
0.00%  
-0.50%  
-1.00%  
-1.50%  
-2.00%  
-2.50%  
-3.00%  
-3.50%  
-4.00%  
Unit A (cooler)  
40%  
Unit B (hotter)  
Unit A  
Unit B  
60%  
0%  
10%  
20%  
30%  
50%  
60%  
70%  
80%  
90%  
100%  
0%  
10%  
20%  
30%  
40%  
50%  
70%  
80%  
90%  
100%  
Load Current (% of Rated Value)  
Load Current (% of Rated Value)  
Figure G: Droop Characteristic with Temperature Mismatch (self balancing)  
Figure F: Example of Droop Characteristic with Output Voltage Mismatch.  
Product # SQ60120QPB33  
Phone 1-888-567-9596  
www.synqor.com  
Doc.# 005-0005266 Rev. F  
03/29/11  
Page 13  
Technical  
Specification  
SQ60120QPB33  
Ordering Information  
Part Numbering System  
Ordering Information  
The part numbering system for SynQor’s dc-dc converters follows the format  
shown in the example below.  
The tables below show the valid model numbers and ordering options for  
converters in this product family. When ordering SynQor converters, please  
ensure that you use the complete 15 character part number consisting of  
the 12 character base part number and the additional characters for options.  
Add “-G” to the model number for 6/6 RoHS compliance.  
SQ 60 120 Q P B 33 N R S - G  
6/6 RoHS  
Input  
Voltage  
36-75V  
Output  
Voltage  
12V  
Max Output  
Current  
Model Number  
Options (see  
Ordering Information)  
SQ60120QPw33xyz-G  
33A  
Output Current  
Thermal Design  
Performance Level  
Package Size  
The following options must be included in place of the w x y z spaces in the  
model numbers listed above.  
Options Description: w x y z  
Thermal Design  
Enable Logic  
Pin Style  
Feature Set  
Output Voltage  
K - 0.110"  
N - 0.145"  
R - 0.180"  
Y - 0.250"  
N - Negative  
P - Positive  
Input Voltage  
B - Baseplated  
S - Standard  
Product Family  
The first 12 characters comprise the base part number and the last 3  
characters indicate available options. The “-G” suffix indicates 6/6 RoHS  
compliance.  
Not all combinations make valid part numbers, please contact SynQor for  
availability. See the Product Summary web page for more options.  
Application Notes  
A variety of application notes and technical white papers can be downloaded  
in pdf format from our website.  
RoHS Compliance: The EU led RoHS (Restriction of Hazardous  
Substances) Directive bans the use of Lead, Cadmium, Hexavalent  
Chromium, Mercury, Polybrominated Biphenyls (PBB), and Polybrominated  
Diphenyl Ether (PBDE) in Electrical and Electronic Equipment. This SynQor  
product is 6/6 RoHS compliant. For more information please refer to  
SynQor’s RoHS addendum available at our RoHS Compliance / Lead Free  
Initiative web page or e-mail us at rohs@synqor.com.  
PATENTS  
SynQor holds the following U.S. patents, one or more of which apply to  
each product listed in this document. Additional patent applications may  
be pending or filed in the future.  
5,999,417  
6,731,520  
7,072,190  
7,272,023  
6,222,742  
6,894,468  
7,085,146  
7,558,083  
6,545,890  
6,896,526  
7,119,524  
7,564,702  
6,577,109  
6,927,987  
7,269,034  
7,765,687  
6,594,159  
7,050,309  
7,272,021  
7,787,261  
Contact SynQor for further information:  
Phone:  
Toll Free: 888-567-9596  
978-849-0600  
Warranty  
SynQor offers a three (3) year limited warranty. Complete warranty  
information is listed on our website or is available upon request from  
SynQor.  
Fax:  
E-mail:  
Web:  
978-849-0602  
power@synqor.com  
www.synqor.com  
Address: 155 Swanson Road  
Boxborough, MA 01719  
USA  
Information furnished by SynQor is believed to be accurate and reliable.  
However, no responsibility is assumed by SynQor for its use, nor for any  
infringements of patents or other rights of third parties which may result  
from its use. No license is granted by implication or otherwise under any  
patent or patent rights of SynQor.  
Product # SQ60120QPB33  
Phone 1-888-567-9596  
www.synqor.com  
Doc.# 005-0005266 Rev. F  
03/29/11  
Page 14  

相关型号:

SQ60120QPB33xyz-G

High efficiency, 94.3% at full rated load current
SYNQOR

SQ606

SQ606
ETC

SQ6601PT

Off-Line Quasi-Resonance Flyback Switching Regulator
AUK

SQ7002K

Automotive N-Channel 60 V (D-S) 175 MOSFET
VISHAY

SQ701

SILICON GATE ENHANCEMENT MODE RF POWER VDMOS TRANSISTOR
POLYFET

SQ721

SILICON GATE ENHANCEMENT MODE RF POWER VDMOS TRANSISTOR
POLYFET

SQ741

SILICON GATE ENHANCEMENT MODE RF POWER VDMOS TRANSISTOR
POLYFET

SQ7414AEN

Power Field-Effect Transistor,
VISHAY

SQ7414AEN-T1-GE3

Automotive P-Channel 60 V (D-S) 175 °C MOSFET
VISHAY

SQ7414AEN-T1_GE3

Power Field-Effect Transistor,
VISHAY

SQ7414AENW

Automotive P-Channel 60 V (D-S) 175 °C MOSFET
VISHAY
VISHAY