SQ60120QPB33PKS-G [SYNQOR]
DC-DC Regulated Power Supply Module, 1 Output, 396W, Hybrid, ROHS COMPLIANT, QUARTER BRICK PACKAGE-6/5;![SQ60120QPB33PKS-G](http://pdffile.icpdf.com/pdf2/p00242/img/icpdf/SQ60120QPB33_1467774_icpdf.jpg)
型号: | SQ60120QPB33PKS-G |
厂家: | ![]() |
描述: | DC-DC Regulated Power Supply Module, 1 Output, 396W, Hybrid, ROHS COMPLIANT, QUARTER BRICK PACKAGE-6/5 |
文件: | 总14页 (文件大小:2342K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
Technical
Specification
SQ60120QPB33
36-75V
100V
Transient Input
12V
Output
396W
Max Power
2250V dc Quarter-brick
Input
Isolation
DC-DC Converter
The SQ60120QPB33 bus converter is a next-generation,
board-mountable, isolated, fixed switching frequency dc-
dc converter that uses synchronous rectification to achieve
extremely high conversion efficiency. The SQ BusQor series
provides an isolated step down voltage from 48V to a semi-
regulated 12V intermediate bus. BusQor converters are
ideal for customers who need multiple outputs and wish to
build or buy point of load converters to work with a 12V rail.
RoHS Compliant (see last page).
Operational Features
• High efficiency, 94.3% at full rated load current
• Delivers up to 33A of output current (396W power)
with minimal derating
SQ60120QPB33 Model
• Wide input voltage range: 36-75V, with
100V 100ms input voltage transient capability
• Fixed frequency switching provides predictable EMI performance
• No minimun load requirement
Protection Features
• Input under-voltage lockout and over-voltage shutdown protects
against abnormal input voltages
utput current limit and short circuit protection
utput over-voltage protection
hermal shutdown
Mechanical Features
• Industry standard quarter-brick pin-out configuration
• Industry standard size: 2.30" x 1.45" (58.4 x 36.8mm)
• Total height: 0.50" (12.7mm)
• Total weight: 2.2 oz (62 g)
Control Features
• On/Off control referenced to input side
• Inherent current share (by droop method) for high current and
parallel applications.
Contents
Page No.
Safety Features
• UL 60950-1:2007
• EN60950-1/A11:2009/A1:2010
• CAN/CSA-C22.2 No. 60950-1:2007
• IEC 61000-4-2
Baseplated Mechanical. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Electrical Characteristics. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Standards & Qualifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Figures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Application Section . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Ordering Information. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Product # SQ60120QPB33
Phone 1-888-567-9596
www.synqor
Technical
Specification
SQ60120QPB33
Baseplated Mechanical
TOP VIEW
1.45[36,8]
SIDE VIEW
.600[15,24]
M3x.5
THREADED HOLE
x3
.500 ± .034
[12,70 ± 0,86]
OVERALL HEIGHT
6
SEE NOTES 1 & 2
5
.145
[3,68]
SEE NOTE 5
2.30
[58,4]
1.860
[47,24]
2.00
[50,8]
.14
[3,6]
2
1
3
.033± .032
.160[4,06]
1.130[28,7]
[ 0,84± 0,81]
BOTTOMSIDE
CLEARANCE
.43[10,8]
.300[7,62]
.600[15,24]
.220
[5,59]
NOTES
PIN DESIGNATIONS
1)
M3 screws used to bolt unit's baseplate to other surfaces
such as heastsink must not exceed 0.10" (2.54mm)
depth below the surface of the baseplate.
Pin
Name
Function
1
2
3
5
6
Vin(+)
ON/OFF
Vin(–)
Vout(–)
Vout(+)
Positive input voltage
Logic control input to turn converter on/off
Negative input
Negative output
Positive output
2)
3)
Applied torque per screw should not exceed 6in-lb (0.7nm)
Pins 1-3 are 0.040" (1.02mm) Dia. with 0.080" (2.03mm) dia.
standoff shoulders
Pins 5-6 are 0.062" (1.57mm) Dia. with 0.100" (2.54mm) Dia.
standoff shoulders
4)
5)
6)
Other pin extension lengths available
All Pins: Material - Copper Alloy
Finish: Matte Tin over Nickel plate
7)
8)
9)
Baseplate flatness tolerance is 0.004" (.10mm) TIR for surface.
Undimensioned components are shown for visual reference only
Weight: 2.2 oz (62 g)
All dimensions in inches (mm)
10)
Tolerances: x.xx +/-0.02 in. (x.x +/-0.5mm)
x.xxx +/-0.010 in. (x.xx +/-0.25mm)
Product # SQ60120QPB33
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-0005266 Rev. F
03/29/11
Page 2
Input: 36-75V
Output: 12V
Current: 33A
Package: Quarter-brick
Technical Specification
SQ60120QPB33 Electrical Characteristics
Ta = 25°C, airflow rate = 300 LFM, Vin = 48Vdc unless otherwise noted; full operating temperature range is -40°C to +100°C ambient temperature with
appropriate power derating. Specifications subject to change without notice.
Parameter
ABSOLUTE MAXIMUM RATINGS
Min.
Typ.
Max. Units Notes & Conditions
Input Voltage
Non-Operating
Operating
Operating Transient Protection
Isolation Voltage
0
36
100
75
100
V
V
V
Continuous
Continuous
100 ms transient, square wave
48
Input to Output
Operating Temperature
Storage Temperature
2250
100
125
18
V
°C
°C
V
-40
-55
-2
Voltage at ON/OFF input pin
INPUT CHARACTERISTICS
Operating Input Voltage Range
Input Under-Voltage Lockout
Turn-On Voltage Threshold
Turn-Off Voltage Threshold
Lockout Voltage Hysteresis
Input Over-Voltage Shutdown
Turn-On Voltage Threshold
Turn-Off Voltage Threshold
Maximum Input Current
No-Load Input Current
36
48
75
V
31.0
27.6
2
34.5
32
4
V
V
V
95
105
V
V
A
mA
mA
mA
mA
A
12.9
130
8.5
20
800.0
15
Disabled Input Current
Input Reflected-Ripple Current
Input Terminal-Ripple Current
Recommended Input Fuse (see Note 1)
Recommended External Input Capacitance
Input Filter Component Values (L\C)
OUTPUT CHARACTERISTICS
Output Voltage Set Point
Output Voltage Regulation
Over Line
Over Load
Over Temperature
Total Output Voltage Range
Output Voltage Ripple and Noise
Peak-to-Peak
10
400.0
RMS through 10µH inductor
RMS, full load
Fast blow external fuse recommended
Typical ESR 0.1-0.2 Ω
47
0.47\6.6
µF
µH\µF Internal values; see Figure E
12.46
12.5
12.54
V
Vin = 65 V, Io = 0 A, Ta = 25 °C
'+0.18\-1.25
+0\-0.80
±300
V
V
mV
V
10.250
0
12.830
Over sample, line, load, temperature & life
20 MHz bandwidth; see Note 2
Full load
Full load
Subject to thermal derating
Output voltage 10% Low
200
50
325
115
33
mV
mV
A
RMS
Operating Output Current Range
Output DC Current-Limit Inception
Output DC Current-Limit Shutdown Voltage
Back-Drive Current Limit while Disabled
Maximum Output Capacitance
DYNAMIC CHARACTERISTICS
Output Voltage during Load Current Transient
Step Change in Output Current (0.1 A/µs)
Settling Time
40
10.5
50
A
V
mA
µF
Negative current drawn from output
Vout nominal at full load (resistive load)
3,000
1600
250
2,500
350
mV
µs
50% to 75% to 50% Iout max
To within 1% Vout nom
Turn-On Transient
Turn-On Time
Start-Up Inhibit Time
Output Voltage Overshoot
15
200
0
30
ms
ms
%
Full load, Vout=90% nom.
-40 °C to +125 °C; Figure F
3 mF load capacitance
Product # SQ60120QPB33
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-0005266 Rev. F
03/29/11
Page 3
Input: 36-75V
Output: 12V
Current: 33A
Package: Quarter-brick
Technical Specification
SQ60120QPB33 Electrical Characteristics (continued)
Ta = 25°C, airflow rate = 300 LFM, Vin = 48Vdc unless otherwise noted; full operating temperature range is -40°C to +100°C ambient temperature with
appropriate power derating. Specifications subject to change without notice.
Parameter
Min.
Typ.
Max. Units Notes & Conditions
ISOLATION CHARACTERISTICS
Isolation Voltage (dielectric strength)
Isolation Resistance
V
MΩ
pF
See Absolute Maximum Ratings
See Note 3
2250
30
470
Isolation Capacitance (input to output)
TEMPERATURE LIMITS FOR POWER DERATING CURVES
Semiconductor Junction Temperature
Board Temperature
Transformer Temperature
EFFICIENCY
125
125
125
°C
°C
°C
Package rated to 150 °C
UL rated max operating temp 130 °C
100% Load
50% Load
94.3
94.8
%
%
FEATURE CHARACTERISTICS
Switching Frequency
212
250
288
kHz
ON/OFF Control (Option P)
Off-State Voltage
On-State Voltage
-1
2.4
0.8
18
V
V
ON/OFF Controll (Option N)
Off-State Voltage
On-State Voltage
2.4
-1
18
0.8
V
V
ON/OFF Control (Either Option)
Pull-Up Voltage
Pull-Up Resistance
Output Over-Voltage Protection
Over-Temperature Shutdown OTP Trip Point
Over-Temperature Shutdown Restart Hysteresis
RELIABILITY CHARACTERISTICS
Calculated MTBF (Telcordia) TR-NWT-000332
Calculated MTBF (MIL-217) MIL-HDBK-217F
Field Demonstrated MTBF
Application notes Figures A & B
5.0
124
16
V
kΩ
V
°C
°C
Over full temp range; no load
Average PCB Temperature
140
150
10
2.6
2.1
TBD
106 Hrs. 80% load, 200LFM, 40 °C Ta
106 Hrs. 80% load, 200LFM, 40 °C Ta
106 Hrs. See our website for details
Note 1: UL’s product certification tests were carried out using 15A fast blow fuse. Fuse interruption characteristics have to be taken into account
while designing input traces. User should ensure that Input trace is capable of withstanding fault currents
Note 2: For applications requiring reduced output voltage ripple and noise, consult SynQor applications support (e-mail: support@synqor.com)
Note 3: Isolation capacitance can be added external to the module.
Product # SQ60120QPB33
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-0005266 Rev. F
03/29/11
Page 4
Input: 36-75V
Output: 12V
Current: 33A
Package: Quarter-brick
Technical Specification
Standards Compliance & Qualification Testing
Parameter
STANDARDS COMPLIANCE
Notes & Conditions
UL 60950-1:2007
Basic insulation
EN60950-1/A11:2009/A1:2010
CAN/CSA-C22.2 No. 60950-1:2007
IEC 61000-4-2
ESD test, 8 kV - NP, 15 kV air - NP (Normal Performance)
Note: An external input fuse must always be used to meet these safety requirements. Contact SynQor for official safety certificates on new
releases or download from the SynQor website.
Parameter
# Units Test Conditions
QUALIFICATION TESTING
Life Test
32
95% rated Vin and load, units at derating point, 1000 hours
Vibration
5
5
10
5
5
5
10-55 Hz sweep, 0.060" total excursion, 1 min./sweep, 120 sweeps for 3 axis
100g minimum, 2 drops in x, y and z axis
Mechanical Shock
Temperature Cycling
Power/Thermal Cycling
Design Marginality
Humidity
-40 °C to 100 °C, unit temp. ramp 15 °C/min., 500 cycles
Toperating = min to max, Vin = min to max, full load, 100 cycles
Tmin-10 °C to Tmax+10 °C, 5 °C steps, Vin = min to max, 0-105% load
85 °C, 85% RH, 1000 hours, continuous Vin applied except 5 min/day
MIL-STD-883, method 2003
Solderability
15 pins
Product # SQ60120QPB33
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-0005266 Rev. F
03/29/11
Page 5
Input: 36-75V
Output: 12V
Current: 33A
Package: Quarter-brick
Technical Specification
100
95
90
85
80
75
70
30
25
20
15
10
5
36 Vin
48 Vin
75 Vin
36 Vin
48 Vin
75 Vin
0
0
3
6
9
12
15
18
21
24
27
30
33
0
3
6
9
12
15
18
21
24
27
30
33
Load Current (A)
Load Current (A)
Figure 1: Efficiency at nominal output voltage vs. load current for minimum,
nominal, and maximum input voltage at 25 °C.
Figure 2: Power dissipation at nominal output voltage vs. load current for
minimum, nominal, and maximum input voltage at 25 °C.
96.0
95.5
95.0
94.5
20
19
18
17
16
15
14
13
94.0
25º C
25º C
12
40º C
40º C
93.5
55º C
55º C
11
10
93.0
100
200
300
400
100
200
300
400
Air Flow (LFM)
Air Flow (LFM)
Figure 3: Efficiency at nominal output voltage and 60 % rated power vs. airflow
rate for ambient air temperatures of 25, 40, and 55 °C (nominal input voltage).
Figure 4: Power dissipation at nominal output voltage and 60 % rated power
vs. airflow rate for ambient air temperatures of 25, 40, and 55 °C (nominal input
voltage).
40
30
400
350
300
250
200
20
150
400 LFM (2.0 m/s)
400 LFM (2.0 m/s)
300 LFM (1.5 m/s)
300 LFM (1.5 m/s)
10
100
200 LFM (1.0 m/s)
100 LFM (0.5 m/s)
200 LFM (1.0 m/s)
100 LFM (0.5 m/s)
50
0
0
25
40
50
60
70
85
25
40
50
60
70
85
Ambient Air Temperature (ºC)
Ambient Air Temperature (ºC)
Figure 5: Maximum output current derating curves vs. ambient air temperature
for airflow rates of 100 LFM through 400 LFM with air flowing from pin 3 to pin
1 (nominal input voltage).
Figure 6: Maximum output power derating curves vs. ambient air temperature
for airflow rates of 100 LFM through 400 LFM with air flowing from pin 3 to pin
1 (nominal input voltage).
Product # SQ60120QPB33
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-0005266 Rev. F
03/29/11
Page 6
Input: 36-75V
Output: 12V
Current: 33A
Package: Quarter-brick
Technical Specification
40
400
350
300
250
200
150
100
50
30
20
400 LFM (2.0 m/s)
400 LFM (2.0 m/s)
300 LFM (1.5 m/s)
300 LFM (1.5 m/s)
200 LFM (1.0 m/s)
100 LFM (0.5 m/s)
10
200 LFM (1.0 m/s)
100 LFM (0.5 m/s)
0
0
25
40
50
60
70
85
25
40
50
60
70
85
Ambient Air Temperature (ºC)
Ambient Air Temperature (ºC)
Figure 7: Maximum output current derating curves vs. ambient air temperature
for airflow rates of 100 LFM through 400 LFM with air flowing from input to
output (nominal input voltage).
Figure 8: Maximum output power derating curves vs. ambient air temperature
for airflow rates of 100 LFM through 400 LFM with air flowing from input to
output (nominal input voltage).
Figure 9: Turn-on transient at half load (resistive load) and 3mF output
capacitance (5 ms/div). Input voltage pre-applied. Ch 1: Vout (5V/div). Ch 2:
ON/OFF input (2 V/div).
Figure 10: Turn-on transient at zero load and 3mF output capacitance (5 ms/
div). Input voltage pre-applied. Ch 1: Vout (5V/div). Ch 2: ON/OFF input (2 V/
div).
Figure 11: Output voltage response to step-change in load current (50%-75%-
50% of Iout(max); dI/dt = 0.1A/µs). Load cap: 100µF, electrolytic cap, 15uF
tantalum cap, and 1µF ceramic cap. Ch 1: Vout (2V/div), Ch 2: Iout (10A/div).
Product # SQ60120QPB33
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-0005266 Rev. F
03/29/11
Page 7
Input: 36-75V
Output: 12V
Current: 33A
Package: Quarter-brick
Technical Specification
Input
Reflected
Ripple
Input
Terminal
Ripple
Output
Voltage
Ripple
Current
Current
source
impedance
iS
iC
DC-DC
Converter
V
OUT
V
SOURCE
electrolytic
capacitor
ceramic electrolytic
capacitor capacitor
Figure 12: Test set-up diagram showing measurement points for Input Terminal
Ripple Current (Figure 13), Input Reflected Ripple Current (Figure 14), and
Output Voltage Ripple (Figure 15).
Figure 13: Input Terminal Ripple Current, ic, at full rated output current and
nominal input voltage with 10µH source impedance and 47µF electrolytic
capacitor (500 mA/div). See Figure 12.
Figure 14: Input reflected ripple current, is, through a 10 µH source inductor,
using a 47µF electrolytic input capacitor (20mA/div). See Figure 12.
Figure 15: Output voltage ripple at nominal input voltage and rated load current
(100 mV/div). Load capacitance: 1µF ceramic capacitor and 15µF tantalum
capacitor. Bandwidth: 20 MHz. See Figure 12.
14
12
10
8
6
4
36 Vin
48 Vin
2
75 Vin
0
0
10
20
30
40
50
60
70
Load Current (A)
Figure 16: Output voltage vs. load current showing typical current limit curves
and converter shutdown points.
Figure 17: Load current (25A/div) as a function of time when the converter
attempts to turn on into a 1 mΩ short circuit. Top trace (500us/div) is an
expansion of the on-time portion of the bottom trace
Product # SQ60120QPB33
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-0005266 Rev. F
03/29/11
Page 8
Input: 36-75V
Output: 12V
Current: 33A
Package: Quarter-brick
Technical Specification
1
0
-5
-10
-15
-20
-25
-30
-35
-40
-45
-50
-55
-60
0.1
36 Vin
48 Vin
75 Vin
36 Vin
48 Vin
75 Vin
0.01
10
100
1,000
Hz
10,000
100,000
10
100
1,000
Hz
10,000
100,000
Figure 18: Magnitude of incremental output impedance (Zout = Vout/Iout) for
minimum, nominal, and maximum input voltage at full rated power.
Figure 19: Magnitude of incremental forward transmission (FT = Vout/Vin) for
minimum, nominal, and maximum input voltage at full rated power.
1000
100
10
0
-10
-20
36 Vin
1
-30
36 Vin
48 Vin
48 Vin
75 Vin
75 Vin
-40
0.1
10
100
1,000
Hz
10,000
100,000
10
100
1,000
Hz
10,000
100,000
Figure 20: Magnitude of incremental reverse transmission (RT = Iin/Iout) for
minimum, nominal, and maximum input voltage at full rated power.
Figure 21: Magnitude of incremental input impedance (Zin = Vin/Iin) for
minimum, nominal, and maximum input voltage at full rated power.
Product # SQ60120QPB33
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-0005266 Rev. F
03/29/11
Page 9
Technical
Specification
SQ60120QPB33
Application Section
BASIC OPERATION AND FEATURES
CONTROL FEATURES
With voltages dropping and currents rising, the economics
of an Intermediate Bus Architecture (IBA) are becoming
more attractive, especially in systems requiring multiple
low voltages. IBA systems separate the role of isolation and
voltage scaling from regulation and sensing. The BusQor
series bus converter provides isolation and a coarse voltage
step down in one compact module, leaving regulation to
simpler, less expensive non-isolated converters.
REMOTE ON/OFF (Pin 2): The ON/OFF input, Pin 2,
permits the user to control when the converter is on or off.
This input is referenced to the return terminal of the input
bus, Vin(-). There are two versions of the converter that
differ by the sense of the logic used for the ON/OFF input.
In the positive logic version, the ON/OFF input is active
high (meaning that a high turns the converter on). In the
negative logic version, the ON/OFF signal is active low
(meaning that a low turns the converter on). Figure B is a
detailed look of the internal ON/OFF circuitry.
In Figure A below, the BusQor module provides the isolation
stage of the IBA system. The isolated bus then distributes
power to the non-isolated buck regulators to generate the
required voltage levels at the point of load. In this case, the
bucks are represented with SynQor’s NiQor series of non-
isolated dc-dc converters. In many applications requiring
multiple low voltage outputs, significant savings can be
achieved in board space and overall system costs.
When designing an IBA system with bus converters, the
designer can select from a variety of bus voltages. While
there is no universally ideal bus voltage, most designs
employ one of the following: 12V, 9V, 7.5V, 5V, or 3.3V.
Higher bus voltages can lead to lower efficiency for the buck
regulators but are more efficient for the bus converter and
provide lower board level distribution current. Lower bus
voltages offer the opposite trade offs.
SynQor’s SQ BusQor modules accept the full 48/60V
telecom bus voltage and have a narrow output voltage
range compatible with many non-isolated point of load
converters. When used in IBA systems, the output variation
of the BusQor must be in accordance with the input voltage
range of the non-isolated converters being employed.
3.3V
48Vdc
36-75V
2.5V
1.8V
+5V
5V
12Vdc
+
Vin( )
BusQor
Converter
124k
1.5V
0.9V
ON/OFF
49.9k
100k
NiQor
Converters
Loads
TTL
Typical User Board
48Vdc
Front End
Vin(_)
Figure A: Example of Intermediate Bus Architecture using BusQor bus converter
and NiQor non-isolated converters
Figure B: Internal ON/OFF pin circuitry
Product # SQ60120QPB33
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-0005266 Rev. F
03/29/11
Page 10
Technical
Specification
SQ60120QPB33
Application Section
Output Short Circuit Protection: When the output of
the BusQor module is shorted, a peak current of typically 55A
will flow into the short circuit for a time of about 1ms. The
output of the BusQor will shutdown to zero volts after the
1ms have elapsed (Fig C & D). The shutdown period lasts
for a time of 200ms, at the end of which the BusQor module
tries to power up again. If the short circuit persists, the
output voltage will go through repeated cycles of shutdown
and restart with a duty cycle of 20ms (On) and 200ms (Off)
respectively. The BusQor module returns (auto resetting)
to normal operation once the short circuit is removed. The
BusQor is designed to survive in this mode indefinitely
without damage and without human intervention.
Protection Features
Input Under-Voltage Lockout: The converter is designed
to turn off when the input voltage is too low, helping avoid
an input system instability problem, described in more detail
in the application note titled “Input System Instability”
available on www.SynQor.com. The lockout circuitry is a
comparator with DC hysteresis. When the input voltage is
rising, it must exceed the typical Turn-On Voltage Threshold
value (listed on the specification page) before the converter
will turn on. Once the converter is on, the input voltage
must fall below the typical Turn-Off Voltage Threshold value
before the converter will turn off. Also see Fig E.
Output Current Limit: The output of the BusQor module
is electronically protected against output overloads. When
an overload current greater than the “DC Current-Limit
Inception” specification is drawn from the output, the
output of the BusQor will shutdown to zero volts after the
1ms have elapsed (see Fig C). The shutdown period lasts
for a typical period of 200ms (Fig D) after which the BusQor
tries to power up again. If the overload persists, the output
voltage will go through repeated cycles of shutdown and
restart with a duty cycle of 20ms (On) and 200ms (Off)
respectively. The BusQor module returns (auto resetting)
to normal operation once the overload is removed. The
BusQor is designed to survive in this mode indefinitely
without damage and without human intervention.
In the Auto resetting mode, also referred to as “Hiccup”
mode, the power drawn from the 48V input is about 5W,
most of which is dissipated into the external fault. It is
important that copper traces and pads from the output
circuit be designed to withstand the short term peaks,
although the average current into the fault may be as low
as 50mA typical. See Fig 17 for appropriate waveform.
Over-Temperature Shutdown: A temperature sensor
on the converter senses the average temperature of the
module. The thermal shutdown circuit is designed to turn
the converter off when the temperature at the sensed
location reaches the Over-Temperature Shutdown value.
It will allow the converter to turn on again when the
temperature of the sensed location falls by the amount of
the Over-Temperature Shutdown Restart Hysteresis value.
55A
peak
Output
Current
Output
Current
55A
33A
Output
Voltage
Output
Voltage
<12V
12V
Time
0V
0V
Shutdown
200ms
Duty
20ms
1ms
Time
Figure C: Output Overload protection diagram (not to scale)
Figure D: Output Short Circuit and Auto-Resetting protection diagram (not to scale)
Product # SQ60120QPB33
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-0005266 Rev. F
03/29/11
Page 11
Technical
Specification
SQ60120QPB33
Application Section
APPLICATION CONSIDERATIONS
Vin
Startup Inhibit Period: Figure E details the Start-Up
Inhibit Period for the BusQor module when Vin is applied
with the On/Off pin asserted (enabled). Before time t1,
when the input voltage Off pin asserted (enabled). Before
time t1, when the input voltage is below the UVL threshold,
the unit is disabled by the Input Under-Voltage Lockout
feature. When the input voltage rises above the UVL
threshold, the Input Under-Voltage Lockout is released, and
a typical Startup Inhibit Period of 8ms from a Vin start-up.
Once the module recognizes it should be on it waits an
additional 4ms before it starts. When starting from an on/
off event the module has an inhibit time of 200ms like our
standard products. The output builds up to 90% or higher
of the nominal voltage and stabilizes to its nominal output
voltage in a total time of 15ms typical.
UVLO
On/Off
(N logic)
OFF
ON
t0
t1
t2
t3
t
Vout
12V
12 ms
200 ms
At time t2, when the On/Off pin is de-asserted (disabled),
the BusQor module stops switching immediately. Fall time
from 12V to 0V is dependent on output capacitance load
current, and any parasitic trace inductance in the output
load circuit.
Fault Inhibit
Start-Up
Time
Start-up
Inhibit
15 ms
At time t3, when the On/Off pin is re-asserted (enabled),
the BusQor module output begins to build up after the
inhibit period of 200ms typical.
Figure E: Power Up/Down Diagram (not to scale) showing Start-Up Inhibit Period.
Refer to the Control Features section of the data sheet for
details on enabling and disabling methods for N and P logic
type modules.
Product # SQ60120QPB33
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-0005266 Rev. F
03/29/11
Page 12
Technical
Specification
SQ60120QPB33
Application Section
Droop Current Sharing:
This product has primary side regulation only. Primary side Temperature Mismatch Self Balancing: the slope of
regulation results in a voltage droop as the load current the output voltage droop characteristic of semi regulated
increase (droop characteristic). The inherent impedance module increases with increased temperature. Therefore,
of the power stage due to its droop characteristic can be if a paralleled unit were hotter than its neighbor because it
used to balance the load current between multiple modules is supplying more load current, then its output voltage will
that are placed in parallel. The graphs in this section show droop further forcing the cooler module(s) to increase its
two units by way of example, but there is no fundamental load current. The increase in effective output resistance
limit to the number of units that can be placed in parallel. due to an increase in temperature acts as a self correcting
mechanism (Fig G) when two or more modules are connected
When multiple units having droop characteristics are placed in a parallel configuration.
in parallel, the current sharing accuracy is determined by the
output voltage set point accuracy relative to the total output
voltage droop for a given load current range. A difference
in voltage between two units will cause a differential current
to flow out of one unit and into the other. Figure F shows an
examplewithtwounitswithanoutputvoltagemismatchedby
0.5%. In this example, when Unit A is at 100% of its full rated
load current, Unit B is only at 90%, effectively reducing the
total available current by 5%. SynQor uses factory calibration
of each unit to ensure that output voltage is well matched.
Droop Characteristics with Voltage Mismatch
Droop Characteristics with Temperature Mismatch (Self Balancing)
0.0%
-0.5%
-1.0%
-1.5%
-2.0%
-2.5%
-3.0%
-3.5%
-4.0%
0.00%
-0.50%
-1.00%
-1.50%
-2.00%
-2.50%
-3.00%
-3.50%
-4.00%
Unit A (cooler)
40%
Unit B (hotter)
Unit A
Unit B
60%
0%
10%
20%
30%
50%
60%
70%
80%
90%
100%
0%
10%
20%
30%
40%
50%
70%
80%
90%
100%
Load Current (% of Rated Value)
Load Current (% of Rated Value)
Figure G: Droop Characteristic with Temperature Mismatch (self balancing)
Figure F: Example of Droop Characteristic with Output Voltage Mismatch.
Product # SQ60120QPB33
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-0005266 Rev. F
03/29/11
Page 13
Technical
Specification
SQ60120QPB33
Ordering Information
Part Numbering System
Ordering Information
The part numbering system for SynQor’s dc-dc converters follows the format
shown in the example below.
The tables below show the valid model numbers and ordering options for
converters in this product family. When ordering SynQor converters, please
ensure that you use the complete 15 character part number consisting of
the 12 character base part number and the additional characters for options.
Add “-G” to the model number for 6/6 RoHS compliance.
SQ 60 120 Q P B 33 N R S - G
6/6 RoHS
Input
Voltage
36-75V
Output
Voltage
12V
Max Output
Current
Model Number
Options (see
Ordering Information)
SQ60120QPw33xyz-G
33A
Output Current
Thermal Design
Performance Level
Package Size
The following options must be included in place of the w x y z spaces in the
model numbers listed above.
Options Description: w x y z
Thermal Design
Enable Logic
Pin Style
Feature Set
Output Voltage
K - 0.110"
N - 0.145"
R - 0.180"
Y - 0.250"
N - Negative
P - Positive
Input Voltage
B - Baseplated
S - Standard
Product Family
The first 12 characters comprise the base part number and the last 3
characters indicate available options. The “-G” suffix indicates 6/6 RoHS
compliance.
Not all combinations make valid part numbers, please contact SynQor for
availability. See the Product Summary web page for more options.
Application Notes
A variety of application notes and technical white papers can be downloaded
in pdf format from our website.
RoHS Compliance: The EU led RoHS (Restriction of Hazardous
Substances) Directive bans the use of Lead, Cadmium, Hexavalent
Chromium, Mercury, Polybrominated Biphenyls (PBB), and Polybrominated
Diphenyl Ether (PBDE) in Electrical and Electronic Equipment. This SynQor
product is 6/6 RoHS compliant. For more information please refer to
SynQor’s RoHS addendum available at our RoHS Compliance / Lead Free
Initiative web page or e-mail us at rohs@synqor.com.
PATENTS
SynQor holds the following U.S. patents, one or more of which apply to
each product listed in this document. Additional patent applications may
be pending or filed in the future.
5,999,417
6,731,520
7,072,190
7,272,023
6,222,742
6,894,468
7,085,146
7,558,083
6,545,890
6,896,526
7,119,524
7,564,702
6,577,109
6,927,987
7,269,034
7,765,687
6,594,159
7,050,309
7,272,021
7,787,261
Contact SynQor for further information:
Phone:
Toll Free: 888-567-9596
978-849-0600
Warranty
SynQor offers a three (3) year limited warranty. Complete warranty
information is listed on our website or is available upon request from
SynQor.
Fax:
E-mail:
Web:
978-849-0602
power@synqor.com
www.synqor.com
Address: 155 Swanson Road
Boxborough, MA 01719
USA
Information furnished by SynQor is believed to be accurate and reliable.
However, no responsibility is assumed by SynQor for its use, nor for any
infringements of patents or other rights of third parties which may result
from its use. No license is granted by implication or otherwise under any
patent or patent rights of SynQor.
Product # SQ60120QPB33
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-0005266 Rev. F
03/29/11
Page 14