FIREFLY-TX2 [RFMD]
VIPER Remote Control Systems; VIPER远程控制系统![FIREFLY-TX2](http://pdffile.icpdf.com/pdf1/p00184/img/icpdf/FIREFL_1041827_icpdf.jpg)
型号: | FIREFLY-TX2 |
厂家: | ![]() |
描述: | VIPER Remote Control Systems |
文件: | 总6页 (文件大小:1963K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
![](http://public.icpdf.com/style/img/ads.jpg)
VIPER Remote Control Systems
•
•
•
•
•
•
•
•
•
433MHz FM Technology
1 – 4 Channels each 1000W Rated
upto 150metres Range
12-30Vdc / 230Vac supply
Waterproof (IP68)
High Security RF Protocol
4 Relays 5A @ 230Vac
Outputs Momentary or Latching
Any Switch Map to Any Relay
Output
•
•
Systems supplied ’ready to Go’
EMC / FCC Compliant for Europe /
USA
Applications
•
•
•
•
General Purpose Remote Switching
Garage Doors
Electric Gates, Shutters
All known Lighting types (LED, fluorescent, halogen,
tungsten, xenon; basically all lighting types).
•
Access Control
Description
Housed in a rugged IP68 weatherproof enclosure, The VIPER system is ideally suited
to any outside Remote switch requirement.
Each receiver has 4 relays, using the ‘easy-learn’ process each relay can be controlled
from any switch on any transmitter.
Installation is by screw terminals to the power supply, and the output relay contacts.
The output relays are activated by the button press on the transmitter encoder.
DS VIPER-2
©2009 REG No 277 4001, Lewes, England. Page 1
VIPER Remote Control Systems
Systems Part Numbers
Operating from 12-30Vdc
Receiver
Range**
Part Number
Description
Power Supply
(Metres)
VIPER-S1
VIPER-S2
System 1 channel
System 2 channel
12-30Vdc
150
12-30Vdc
12-30Vdc
150
150
VIPER-S4
System 4 channel
Systems Operating from 230Vac (see DS-VIPERMAINS)
Receiver
Range**
Part Number
Description
Power Supply
(Metres)
VIPER-S1M
VIPER-S2M
System 1 channel
System 2 channel
230Vac
150
230Vac
150
**Range stated is optimum, direct line of sight. In worst conditions this can be reduced by over 50%
Additional Transmitters
Transmitters ship with; Wall Mounting Cradle,
and Lanyard
Part Number
FIREFLY-TX1
Description
Transmitter 1 switch
Transmitter 2 switch
FIREFLY-TX2
FIREFLY-TX4
Transmitter 4 switch
Transmitter 8 switch
FIREFLY-TX8
FIREFLY-TX16
Transmitter 16 switch (8Sw + Shift Key)
’O’ Ring, Seals Transmitter to IP68
FIREFLY -TX-IPKIT
Custom Version
To create a custom version requires just a Sticker!
Please contact Sales for further info.
DS VIPER-2
©2009 REG No 277 4001, Lewes, England. Page 2
VIPER Remote Control Systems
Data Outputs
Each output relay provides an isolated switch. Connections are Common (COM), Normally Open (NO) and
Normally Closed (NC).
Relay Connections when
Transmitter NOT Operating
Relay Connections when
Transmitter OPERATING
Installation
Below is a simple example showing one possible way to wire a relay in order to give switched power
to an external load:
When the relay is energised the ‘COM’ connects to ’NO’ and power is applied to the Load.
R F Solutions Ltd.,
Unit 21, Cliffe Industrial Estate,
Lewes, E. Sussex. BN8 6JL. England.
Email : sales@rfsolutions.co.uk
http://www.rfsolutions.co.uk
Tel: +44 (0)1273 898 000 Fax: +44 (0)1273 480 661
DS VIPER-2
©2009 REG No 277 4001, Lewes, England. Page 3
VIPER Remote Control Systems
Pairing a Transmitter to a Receiver
Each transmitter has a unique identity. Each time a transmitter Switch is operated, it emits a secure
RF signal. The Receiver can learn this signal and allocate to any of its outputs.
The only limitation is that each receiver has a maximum memory for upto 40 pairings, these can be from
the same or any number of transmitters.
Hint: the same transmitter may be taught to different receivers to create ‘master keys’.
VIPER-S1 / VIPER-S2 / VIPER-S3 (12-30Vdc Receivers)
To Learn a New Transmitter switch follow this procedure
Any transmitter button can be learnt to one or many of the receiver output relays.
Each button must be learnt to each relay individually by following this procedure:
1.
Select the receiver output relay to learn to:
2.
3.
4.
5.
Briefly press the receiver Learn switch (S2) once
The Learn LED will flash once to indicate output relay 1 is selected
After the LED stops flashing, press the Learn switch again to select the next relay channel
Repeat step 2 until the required output relay is selected.
6.
7.
8.
9.
Press the button on the transmitter you want to learn to the relay output.
The Learn LED will then illuminate, press the same transmitter button again.
The Learn LED will then flash to indicate learning is complete.
The transmitter button will now operate the relay.
Erasing Receivers Memory
1.
Press and hold the receiver Learn Switch for approx 10 seconds.
2.
When the Learn LED turns OFF all memory is erased
NOTE: You cannot erase individual Tx encoders
Configuring Receiver Outputs
The jumper links configure the outputs to be Momentary or Latching.
The jumper links are made / removed by the small link ‘cap’ placed over the pin header.
Link Positions
Relay Outputs
LK1
LK2
Closed
Open
RLY 1
Mom
Mom
RLY 2
RLY 3
Mom
RLY 4
Mom
Closed
Closed
Mom
Mom
Latch
Latch
Open
Open
Closed
Open
Mom
Latch
Latch
Latch
Latch
Latch
Latch
Latch
(The configuration shown in the picture above represents the third row of the table)
DS VIPER-2
©2009 REG No 277 4001, Lewes, England. Page 4
VIPER Remote Control Systems
VIPER-S1M / VIPER S2M (230Vac Powered Receivers)
Please Note: During Learn and Erase the relays operate at high speed. They should be isolated from sensi-
tive equipment during this process.
To Pair a Transmitter button to receiver Output Relay #1
1.
Apply power the receiver and wait 10secs for the unit to enter ‘normal operation’ mode.
2.
Switch the receiver unit OFF and then ON again in ~1sec intervals FOUR times finally leaving the unit
powered.
3.
5.
6.
7.
8.
After 5 seconds the receiver emits a single ‘buzz’ The unit is now in ‘learn’ Mode
Press the chosen transmitter button.
The receiver will acknowledge by sounding the a single ’buzz’
Press the same transmitter button again, to confirm OK. The receiver will “buz” again to confirm.
Learn Process complete. After 10 seconds the unit will return to ‘normal operation’ mode.
To Pair a Transmitter button to receiver Output Relay #2
1.
Apply power the receiver and wait 10secs for the unit to enter ‘normal operation’ mode.
2.
Switch the receiver unit OFF and then ON again in ~1sec intervals SIX times finally leaving the unit
powered.
3.
5.
6.
7.
After 5 seconds the receiver emits a double ‘buzz’ The unit is now in ‘learn’ Mode
Press the chosen transmitter button.
The receiver will acknowledge by sounding the a double ’buzz’
Press the same transmitter button again, to confirm OK. The receiver will double “buzz” again to
confirm.
8.
Learn Process complete. After 10 seconds the unit will return to ‘normal operation’ mode.
Erasing Receivers Memory
1.
2.
3.
4.
5.
Power the receiver unit up and wait 10 seconds for the unit to enter ‘normal operation’ mode.
Switch the unit off and then on again at ~1 second intervals TEN times, leaving the unit powered.
Wait 5 seconds until a ‘clicking’ sound is heard for a period of 10 seconds.
Wait 10 seconds for the receiver unit to return to ‘normal’ mode
The unit has now erased all encoder data.
NOTE: You cannot erase individual Tx encoders
Configuring Receiver Outputs
The jumper links configure the outputs to be Momentary or Latching.
The jumper links are made/removed by the small link ‘cap’ placed
over the pin header.
Link Positions - Relay Outputs
LK1
Open
Relay #1
Mom
LK2
Open
Relay #2
Mom
Closed
Latch
Closed
Latch
(the above image shows, RLY2 Momentary, RLY1 Latched)
DS VIPER-2
©2009 REG No 277 4001, Lewes, England. Page 5
VIPER Remote Control Systems
Technical Specifications
Transmitters: FIREFLY-TXn
Enclosure Rating:
Battery Type:
Dimensions:
Standard IPx8
CR2032 (supplied)
90 x 54 x 27 mm
Changing the Battery: Remove the six fixing screws, remove battery and replace note polarity
Electrical Characteristics
Min
Typical
Max
Units
Supply Voltage
3V
V
Supply Current
mA
MHz
mW
Frequency:
FireFLY: Wideband
432.90
-
433.920
3
434.10
10
RF Output Power (ERP) @ 433 MHz
Receiver Decoder
Enclosure Rating
Dimensions
Storage Temperature:
IP68
130 x 112 x 42 mm (not including antenna)
-10 to +70o Celsius.
Operating Temperature:
-10 to +50o Celsius.
ELECTRICAL CHARACTERISTICS
Supply Voltage for +12 v
MIN
TYPICAL
MAX
30
DIMENSION
10.5
Vdc
A
Relay Rating* (230Vac) RLY1-4
5
12
Supply Current :
Quiescent
All relays operating*
10
140
mA
mS
Time delay from Tx on Switch to Rx Relay opera-
tion
Time delay from Tx sw relax to Rx Relay release
100
300
MS
*The relay contacts in this unit are for functional use only and must not be used for isolation purposes
R F Solutions Ltd.,
Unit 21, Cliffe Industrial Estate,
Lewes, E. Sussex. BN8 6JL. England.
Email : sales@rfsolutions.co.uk
http://www.rfsolutions.co.uk
Tel: +44 (0)1273 898 000 Fax: +44 (0)1273 480 661
DS VIPER-2
©2009 REG No 277 4001, Lewes, England. Page 6
相关型号:
©2020 ICPDF网 联系我们和版权申明