FIREFLY-TX4 [RFMD]

VIPER Remote Control Systems; VIPER远程控制系统
FIREFLY-TX4
型号: FIREFLY-TX4
厂家: RF MICRO DEVICES    RF MICRO DEVICES
描述:

VIPER Remote Control Systems
VIPER远程控制系统

远程控制
文件: 总6页 (文件大小:1963K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
VIPER Remote Control Systems  
433MHz FM Technology  
1 – 4 Channels each 1000W Rated  
upto 150metres Range  
12-30Vdc / 230Vac supply  
Waterproof (IP68)  
High Security RF Protocol  
4 Relays 5A @ 230Vac  
Outputs Momentary or Latching  
Any Switch Map to Any Relay  
Output  
Systems supplied ’ready to Go’  
EMC / FCC Compliant for Europe /  
USA  
Applications  
General Purpose Remote Switching  
Garage Doors  
Electric Gates, Shutters  
All known Lighting types (LED, fluorescent, halogen,  
tungsten, xenon; basically all lighting types).  
Access Control  
Description  
Housed in a rugged IP68 weatherproof enclosure, The VIPER system is ideally suited  
to any outside Remote switch requirement.  
Each receiver has 4 relays, using the ‘easy-learn’ process each relay can be controlled  
from any switch on any transmitter.  
Installation is by screw terminals to the power supply, and the output relay contacts.  
The output relays are activated by the button press on the transmitter encoder.  
DS VIPER-2  
©2009 REG No 277 4001, Lewes, England. Page 1  
VIPER Remote Control Systems  
Systems Part Numbers  
Operating from 12-30Vdc  
Receiver  
Range**  
Part Number  
Description  
Power Supply  
(Metres)  
VIPER-S1  
VIPER-S2  
System 1 channel  
System 2 channel  
12-30Vdc  
150  
12-30Vdc  
12-30Vdc  
150  
150  
VIPER-S4  
System 4 channel  
Systems Operating from 230Vac (see DS-VIPERMAINS)  
Receiver  
Range**  
Part Number  
Description  
Power Supply  
(Metres)  
VIPER-S1M  
VIPER-S2M  
System 1 channel  
System 2 channel  
230Vac  
150  
230Vac  
150  
**Range stated is optimum, direct line of sight. In worst conditions this can be reduced by over 50%  
Additional Transmitters  
Transmitters ship with; Wall Mounting Cradle,  
and Lanyard  
Part Number  
FIREFLY-TX1  
Description  
Transmitter 1 switch  
Transmitter 2 switch  
FIREFLY-TX2  
FIREFLY-TX4  
Transmitter 4 switch  
Transmitter 8 switch  
FIREFLY-TX8  
FIREFLY-TX16  
Transmitter 16 switch (8Sw + Shift Key)  
’O’ Ring, Seals Transmitter to IP68  
FIREFLY -TX-IPKIT  
Custom Version  
To create a custom version requires just a Sticker!  
Please contact Sales for further info.  
DS VIPER-2  
©2009 REG No 277 4001, Lewes, England. Page 2  
VIPER Remote Control Systems  
Data Outputs  
Each output relay provides an isolated switch. Connections are Common (COM), Normally Open (NO) and  
Normally Closed (NC).  
Relay Connections when  
Transmitter NOT Operating  
Relay Connections when  
Transmitter OPERATING  
Installation  
Below is a simple example showing one possible way to wire a relay in order to give switched power  
to an external load:  
When the relay is energised the ‘COM’ connects to ’NO’ and power is applied to the Load.  
R F Solutions Ltd.,  
Unit 21, Cliffe Industrial Estate,  
Lewes, E. Sussex. BN8 6JL. England.  
Email : sales@rfsolutions.co.uk  
http://www.rfsolutions.co.uk  
Tel: +44 (0)1273 898 000 Fax: +44 (0)1273 480 661  
DS VIPER-2  
©2009 REG No 277 4001, Lewes, England. Page 3  
VIPER Remote Control Systems  
Pairing a Transmitter to a Receiver  
Each transmitter has a unique identity. Each time a transmitter Switch is operated, it emits a secure  
RF signal. The Receiver can learn this signal and allocate to any of its outputs.  
The only limitation is that each receiver has a maximum memory for upto 40 pairings, these can be from  
the same or any number of transmitters.  
Hint: the same transmitter may be taught to different receivers to create ‘master keys’.  
VIPER-S1 / VIPER-S2 / VIPER-S3 (12-30Vdc Receivers)  
To Learn a New Transmitter switch follow this procedure  
Any transmitter button can be learnt to one or many of the receiver output relays.  
Each button must be learnt to each relay individually by following this procedure:  
1.  
Select the receiver output relay to learn to:  
2.  
3.  
4.  
5.  
Briefly press the receiver Learn switch (S2) once  
The Learn LED will flash once to indicate output relay 1 is selected  
After the LED stops flashing, press the Learn switch again to select the next relay channel  
Repeat step 2 until the required output relay is selected.  
6.  
7.  
8.  
9.  
Press the button on the transmitter you want to learn to the relay output.  
The Learn LED will then illuminate, press the same transmitter button again.  
The Learn LED will then flash to indicate learning is complete.  
The transmitter button will now operate the relay.  
Erasing Receivers Memory  
1.  
Press and hold the receiver Learn Switch for approx 10 seconds.  
2.  
When the Learn LED turns OFF all memory is erased  
NOTE: You cannot erase individual Tx encoders  
Configuring Receiver Outputs  
The jumper links configure the outputs to be Momentary or Latching.  
The jumper links are made / removed by the small link ‘cap’ placed over the pin header.  
Link Positions  
Relay Outputs  
LK1  
LK2  
Closed  
Open  
RLY 1  
Mom  
Mom  
RLY 2  
RLY 3  
Mom  
RLY 4  
Mom  
Closed  
Closed  
Mom  
Mom  
Latch  
Latch  
Open  
Open  
Closed  
Open  
Mom  
Latch  
Latch  
Latch  
Latch  
Latch  
Latch  
Latch  
(The configuration shown in the picture above represents the third row of the table)  
DS VIPER-2  
©2009 REG No 277 4001, Lewes, England. Page 4  
VIPER Remote Control Systems  
VIPER-S1M / VIPER S2M (230Vac Powered Receivers)  
Please Note: During Learn and Erase the relays operate at high speed. They should be isolated from sensi-  
tive equipment during this process.  
To Pair a Transmitter button to receiver Output Relay #1  
1.  
Apply power the receiver and wait 10secs for the unit to enter ‘normal operation’ mode.  
2.  
Switch the receiver unit OFF and then ON again in ~1sec intervals FOUR times finally leaving the unit  
powered.  
3.  
5.  
6.  
7.  
8.  
After 5 seconds the receiver emits a single ‘buzz’ The unit is now in ‘learn’ Mode  
Press the chosen transmitter button.  
The receiver will acknowledge by sounding the a single ’buzz’  
Press the same transmitter button again, to confirm OK. The receiver will “buz” again to confirm.  
Learn Process complete. After 10 seconds the unit will return to ‘normal operation’ mode.  
To Pair a Transmitter button to receiver Output Relay #2  
1.  
Apply power the receiver and wait 10secs for the unit to enter ‘normal operation’ mode.  
2.  
Switch the receiver unit OFF and then ON again in ~1sec intervals SIX times finally leaving the unit  
powered.  
3.  
5.  
6.  
7.  
After 5 seconds the receiver emits a double ‘buzz’ The unit is now in ‘learn’ Mode  
Press the chosen transmitter button.  
The receiver will acknowledge by sounding the a double ’buzz’  
Press the same transmitter button again, to confirm OK. The receiver will double “buzz” again to  
confirm.  
8.  
Learn Process complete. After 10 seconds the unit will return to ‘normal operation’ mode.  
Erasing Receivers Memory  
1.  
2.  
3.  
4.  
5.  
Power the receiver unit up and wait 10 seconds for the unit to enter ‘normal operation’ mode.  
Switch the unit off and then on again at ~1 second intervals TEN times, leaving the unit powered.  
Wait 5 seconds until a ‘clicking’ sound is heard for a period of 10 seconds.  
Wait 10 seconds for the receiver unit to return to ‘normal’ mode  
The unit has now erased all encoder data.  
NOTE: You cannot erase individual Tx encoders  
Configuring Receiver Outputs  
The jumper links configure the outputs to be Momentary or Latching.  
The jumper links are made/removed by the small link ‘cap’ placed  
over the pin header.  
Link Positions - Relay Outputs  
LK1  
Open  
Relay #1  
Mom  
LK2  
Open  
Relay #2  
Mom  
Closed  
Latch  
Closed  
Latch  
(the above image shows, RLY2 Momentary, RLY1 Latched)  
DS VIPER-2  
©2009 REG No 277 4001, Lewes, England. Page 5  
VIPER Remote Control Systems  
Technical Specifications  
Transmitters: FIREFLY-TXn  
Enclosure Rating:  
Battery Type:  
Dimensions:  
Standard IPx8  
CR2032 (supplied)  
90 x 54 x 27 mm  
Changing the Battery: Remove the six fixing screws, remove battery and replace note polarity  
Electrical Characteristics  
Min  
Typical  
Max  
Units  
Supply Voltage  
3V  
V
Supply Current  
mA  
MHz  
mW  
Frequency:  
FireFLY: Wideband  
432.90  
-
433.920  
3
434.10  
10  
RF Output Power (ERP) @ 433 MHz  
Receiver Decoder  
Enclosure Rating  
Dimensions  
Storage Temperature:  
IP68  
130 x 112 x 42 mm (not including antenna)  
-10 to +70o Celsius.  
Operating Temperature:  
-10 to +50o Celsius.  
ELECTRICAL CHARACTERISTICS  
Supply Voltage for +12 v  
MIN  
TYPICAL  
MAX  
30  
DIMENSION  
10.5  
Vdc  
A
Relay Rating* (230Vac) RLY1-4  
5
12  
Supply Current :  
Quiescent  
All relays operating*  
10  
140  
mA  
mS  
Time delay from Tx on Switch to Rx Relay opera-  
tion  
Time delay from Tx sw relax to Rx Relay release  
100  
300  
MS  
*The relay contacts in this unit are for functional use only and must not be used for isolation purposes  
R F Solutions Ltd.,  
Unit 21, Cliffe Industrial Estate,  
Lewes, E. Sussex. BN8 6JL. England.  
Email : sales@rfsolutions.co.uk  
http://www.rfsolutions.co.uk  
Tel: +44 (0)1273 898 000 Fax: +44 (0)1273 480 661  
DS VIPER-2  
©2009 REG No 277 4001, Lewes, England. Page 6  

相关型号:

FIREFLY-TX8

RADIO REMOTE CONTROL SYSTEMS
RFSOLUTIONS

FIREFLY-TX8

VIPER Remote Control Systems
RFMD

FIREFOX386SX-CHIPSET

Microprocessor
ETC

FIRETRAP

FIRETRAP
RFSOLUTIONS

FIRETRAP-RX

FIRETRAP
RFSOLUTIONS

FIRETRAP-S1

FIRETRAP
RFSOLUTIONS
RFSOLUTIONS
RFSOLUTIONS
RFSOLUTIONS
RFSOLUTIONS
RFSOLUTIONS
RFSOLUTIONS