Features  
Rugged radio remote control  
One Transmiꢁer can control many receivers  
Waterproof receiver to IP68  
Transmiꢁers available with 1, 2, 3, 4, 16 Switches  
Descripꢀon  
Supplied ready to operate the FIRETRAP system is designed for conꢀnuous operaꢀon 365  
days of the year. This system incorporates IP68 rated enclosures with resin dippedcircuit  
boards for protecꢀon against condensaꢀon.  
Each receiver has four independent outputs which can easily be paired with individual  
switches from one or many transmiꢁers. Building a bespoke control system is easy with  
transmiꢁers containing up to 16 switches.  
DS FIRETRAP-8  
FIRETRAP  
System and Receiver Part Numbers  
Range**  
(Metres)  
Frequency  
(MHz)  
Part Number  
FIRETRAP-S1PRM  
FIRETRAP-S1LAP  
FIRETRAP-S1AS1  
Descripꢀon  
System 1 ch Prewired for Promaꢀc  
(Duraplug)  
433.92  
433.92  
433.92  
250  
250  
250  
System 1 ch Prewired for  
Laporte  
System 1 ch Prewired for Au-  
toSporter  
FIRETRAP-S1  
FIRETRAP-RX  
System 1 channel  
Receiver Unit only  
433.92  
433.92  
250  
250  
Skeet Systems  
Part Number  
Range**  
(Metres)  
Frequency  
(MHz)  
Descripꢀon  
FIRETRAP-SKEET  
Skeet System (TX & 2 x RXs)  
433.92  
250  
Part Number  
Descripꢀon  
FIRETRAP-TX1  
Transmiꢁer 1 switch  
Skeet Transmiꢁer 3 switch  
FIRETRAP-TX3  
FIRETRAP-TX4  
Transmiꢁer 4 switch  
FIRETRAP-TX16  
FIREFLY -TX-IPKIT  
Transmiꢁer 16 switch (8Sw + Shiꢂ Key)  
ORing, Seals Transmiꢁer to IP68  
Transmiꢁers ship with; Wall Mounꢀng Cradle, and Lanyard  
FIRETRAP  
PLEASE READ BEFORE ATTEMPTING INSTALLATION:  
This system is supplied complete with cable in order to connect to the Clay Trap Release.  
Warning : Not all Clay Traps have the same wiring convenꢀon!  
The system is pre-wired (as diagram below) to operate with most trap releases, before connecꢀng, CHECK  
YOUR CONNECTIONS. (using a voltmeter) if you are in any doubt, DO NOT CONNECT THE SYSTEM, consult a  
qualified Electrician. Although the system operates on 12-30V DC damage may occur to the receiver unit if  
wrong connecꢀons are made.  
Installaꢀon Notes  
An ideal installaꢀon would be to firmly fix the FIRETRAP-RX approx. 2 metres from the ground, in direct sight  
of the transmiꢁer. Lowering the height or having obstacles between transmiꢁer and receiver will reduce  
range!  
Connecꢀng Power to the Receiver unit  
The receiver unit requires the following connecꢀons to operate:  
- 12V supply (Brown wire as supplied)  
- OV Supply (Yell/GRN wire as supplied)  
When the Receiver unit has power connected the Power LED will illuminate. This must be onfor the system  
to operate.  
Note:  
If you are pairing mulꢀple transmiꢁer i.e. If you have purchased receivers and transmiꢁers separately. Follow  
the procedure detailed on page 4 to configure your chosen system. FIRETRAP-S1 systems are sold pre-paired.  
ANTENNA  
BUZZER  
REED SWITCH  
LRN SWITCH  
ACK LED  
LRN LED  
JUMPER LINKS  
PWR LED  
Relay 1  
Relay 2  
Relay 3  
NO  
COM  
NC  
FIRETRAP Receiver Wiring  
This diagram shows the standard  
wiring configuration and may be  
adapted to fit Traps requiring other  
switching types.  
12V  
0V  
FIRETRAP  
Check the Wiring required for your Trap:  
The FIRETRAP is capable of switching nearly any trap type, however wiring convenꢀons vary between  
manufacturers. The relays on the FIRETRAP can switch up to 24V DC or 230V AC @ 5A.  
Addiꢀonal Transmiꢁers  
Each transmiꢁer has a unique idenꢀty. Each ꢀme a transmiꢁer switch is operated, it transmits a secure  
RF signal. The Receiver can to set learn this signal and pair it to any of its outputs.  
To pair a New Transmiꢁer switch follow this procedure:  
Any transmiꢁer buꢁon can be paired to one or many of the receiver output relays.  
Each buꢁon must be paired to each relay individually by following this procedure:  
Select the receiver output relay to pair:  
1.  
2.  
3.  
Briefly press the receiver pairing switch (S2) once.  
The Receiver pairing LED will flash once to indicate output relay 1 is selected.  
Aꢂer the Receiver pairing LED stops flashing, press the receiver pairing switch again to select the  
next relay.  
4.  
5.  
6.  
Repeat step 2 unꢀl the required output relay is selected.  
Press the buꢁon on the transmiꢁer you want to pair to the selected relay.  
The receiver pairing LED will Flash once to confirm pairing is complete.  
Erasing Receivers Memory  
Press and hold the receiver pairing switch for approx 10 seconds.  
Release the switch and watch for the receiver LED to flash to confirm erasing.  
Press a buꢁon on the transmiꢁer and ensure no relay acꢀves  
NOTE: You cannot erase individual transmiꢁers or buꢁons  
Configuring Receiver Relays  
The link caps (shown above) configure the outputs operaꢀon. The these links are connected/broken us-  
ing the small link cap placed over the pins. To storethe seꢃng turn power off then back on.  
Link Posiꢀons  
Relay Outputs  
LK1  
LK2  
RLY 1  
RLY 2  
RLY 3  
RLY 4  
Open  
Closed  
Open  
Open  
Open  
Closed  
1/2 sec Mom  
1/2 sec Mom  
Mom  
1/2 sec Mom  
Mom  
1/2 sec Mom  
Mom  
1/2 sec Mom  
Mom  
Mom  
Mom  
Mom  
Closed  
Closed  
-
-
-
FIRETRAP  
Technical Specificaꢀons  
Transmiꢁers: FIRETRAP-TXn  
Enclosure Raꢀng:  
Baꢁery Type:  
Dimensions:  
Standard IPx8  
CR2032 (supplied)  
90 x 54 x 27 mm  
ELECTRICAL CHARACTERISICS  
Supply Voltage  
MIN  
TYPICAL  
3V  
MAX  
UNITS  
V
Supply Current  
mA  
Frequency:  
FIREFLY: Wideband  
433.10  
433.920  
3
434.70  
10  
MHz  
mW  
RF Output Power (ERP) @ 433 MHz  
-
Receiver: FIRETRAP-RX  
Enclosure Raꢀng:  
Dimensions:  
Storage Temperature:  
Operaꢀng Temperature:  
IP68  
130 x 112 x 42 mm (not including antenna)  
-10 to +70o Celsius.  
-10 to +50o Celsius.  
ELECTRICAL CHARACTERISTICS  
Supply Voltage for +12 v  
MIN  
10.5  
TYPICAL  
5
MAX  
30  
DIMENSION  
Vdc  
A
Relay Raꢀng* (230Vac) RLY1-4  
12  
Supply Current :  
Quiescent  
All relays operaꢀng*  
10  
140  
mA  
mS  
Time delay from Tx on switch to Rx Relay operaꢀon  
Time delay from Tx sw relax to Rx Relay release  
100  
300  
MS  
*The relay contacts in this unit are for funcꢀonal use only and must not be used for isolaꢀon purposes  
Is a trade name of R F Solutions Ltd
William alexander house, William way,  
Burgess Hill, West Sussex,  
RH15 9AG  
Email : sales@rfsolutions.co.uhttp://www.rfsolutions.co.u
Tel: +44 (0)1444 22790
Fax: +44 (0)1444 22789
FIRETRAP  
Mechanical Dimensions  
50.00  
All Dimensions in mm  
82.00  
RF Soluꢀons Ltd. Recycling Noꢀce  
Meets the following EC Direcꢀves:  
DO NOT  
Discard with normal waste, please recycle.  
Waste Baꢁeries and Accumulators  
Direcꢀve 2006/66/EC  
ROHS Direcꢀve 2002/95/EC  
Specifies certain limits for hazardous substances.  
Where baꢁeries are fiꢁed, before recycling the prod-  
uct, the baꢁeries must be removed and disposed of  
at a licensed collecꢀon point.  
WEEE Direcꢀve 2002/96/EC  
Waste electrical & electronic equipment. This product must be  
disposed of through a licensed WEEE collecꢀon point.  
RF Soluꢀons Ltd., fulfils its WEEE obligaꢀons by membership  
Environment Agency producer registraꢀon number:  
WEE/JB0104WV.  
Disclaimer:  
Whilst the informaꢀon in this document is believed to be correct at the ꢀme of issue, RF Soluꢀons Ltd does not accept any liability whatsoever for its accuracy, adequacy or completeness. No express  
or implied warranty or representaꢀon is given relaꢀng to the informaꢀon contained in this document. RF Soluꢀons Ltd reserves the right to make changes and improvements to the product(s)  
described herein without noꢀce. Buyers and other users should determine for themselves the suitability of any such informaꢀon or products for their own parꢀcular requirements or specificaꢀon(s).  
RF Soluꢀons Ltd shall not be liable for any loss or damage caused as a result of users own determinaꢀon of how to deploy or use RF Soluꢀons Ltds products. Use of RF Soluꢀons Ltd products or  
components in life support and/or safety applicaꢀons is not authorised except with express wriꢁen approval. No licences are created, implicitly or otherwise, under any of RF Soluꢀons Ltds intellec-  
tual property rights. Liability for loss or damage resulꢀng or caused by reliance on the informaꢀon contained herein or from the use of the product (including liability resulꢀng from negligence or  
where RF Soluꢀons Ltd was aware of the possibility of such loss or damage arising) is excluded. This will not operate to limit or restrict RF Soluꢀons Ltds liability for death or personal injury resulꢀng  
from its negligence.  

相关型号:

FIRETRAP-S1

FIRETRAP
RFSOLUTIONS
RFSOLUTIONS
RFSOLUTIONS
RFSOLUTIONS
RFSOLUTIONS
RFSOLUTIONS
RFSOLUTIONS
RFSOLUTIONS
RFSOLUTIONS

FIS-6100-0035G

IMAGING CAMERA HANDHELD
OMRON

FIS-6100-0038G

IMAGING CAMERA HANDHELD
OMRON

FIS-6100-0039G

IMAGING CAMERA HANDHELD
OMRON