RP40-2415DG [RECOM]
40 Watt Single, Dual, Positive Dual & Triple Output; 40瓦单,双,双正与三路输出![RP40-2415DG](http://pdffile.icpdf.com/pdf1/p00066/img/icpdf/RP40-241-5_348537_icpdf.jpg)
型号: | RP40-2415DG |
厂家: | ![]() |
描述: | 40 Watt Single, Dual, Positive Dual & Triple Output |
文件: | 总5页 (文件大小:88K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
![](http://public.icpdf.com/style/img/ads.jpg)
● 2:1 Wide Input Voltage Range
● 40 Watts Output Power
● 1.6kVDC Isolation
POWERLINE
Features
DC/DC-Converter
● Fixed Operating Frequency
● Six-Sided Continuous Shield
● Design Meet Safety Standard
● International Safety Standard Approvals
● Standard 50.8 x50.8x10.2mm Package
● Efficiency to 90%
RP40-
S_D_TG
Series
Selection Guide 12V, 24V and 48V Input Types
Part Number
Input
Range
VDC
Output
Voltage
VDC
Output
Current
mA
Input (4) Efficiency(5) Capacitive(6)
40 Watt
Current
Load max.
mA
%
µF
Single, Dual,
Positive Dual
Triple Output
RP40-121.5SG
RP40-121.8SG
RP40-122.5SG
RP40-123.3SG
RP40-1205SG
RP40-1212SG
RP40-1215SG
RP40-241.5SG
RP40-241.8SG
RP40-242.5SG
RP40-243.3SG
RP40-2405SG
RP40-2412SG
RP40-2415SG
RP40-481.5SG
RP40-481.8SG
RP40-482.5SG
RP40-483.3SG
RP40-4805SG
RP40-4812SG
RP40-4815SG
RP40-1212DG
RP40-1215DG
RP40-2412DG
RP40-2415DG
RP40-4812DG
RP40-4815DG
9-18
9-18
1.5
1.8
2.5
3.3
5
8000
8000
8000
8000
8000
3333
2666
8000
8000
8000
8000
8000
3333
2666
8000
8000
8000
8000
8000
3333
2666
1800
1400
1800
1400
1800
1400
1351
1579
2137
2750
4065
4065
4015
649
78
80
82
84
86
86
87
81
83
85
87
89
88
89
82
84
86
88
90
89
89
85
85
87
87
87
87
45000
37700
27000
21000
13600
2360
&
9-18
9-18
9-18
9-18
12
15
1.5
1.8
2.5
3.3
5
9-18
1510
18-36
18-36
18-36
18-36
18-36
18-36
18-36
36-75
36-75
36-75
36-75
36-75
36-75
36-75
9-18
45000
37700
27000
21000
13600
2360
759
1029
1325
1961
2048
1985
321
12
15
1.5
1.8
2.5
3.3
5
1510
45000
37700
27000
21000
13600
2360
375
508
655
969
12
15
12
15
12
15
12
15
1000
992
1510
4444
4321
2169
2108
1084
1054
1200
9-18
750
18-36
18-36
36-75
36-75
1200
750
1200
750
for Triple Output continued on next page
Description
The RP40-xxxxG Series of DC/DC Converters are fully certified to EN 60950: 2000. This makes them
ideal for all
Telecom and safety applications where approved isolation is required.
They also meet UL 1950 and CSA 950 standards.
21-July-2005
www.recom-international.com
253
POWERLINE
RP40-S_D_TG
Series
DC/DC-Converter
Selection Guide 12V, 24V and 48V Input Types
Part Number
Input
Range
VDC
Output
Voltage
VDC
Output
Current
mA
Input (4) Efficiency(5) Capacitive(6)
Current
Load max.
mA
%
µF
RP40-123.305DG
RP40-243.305DG
RP40-483.305DG
9-18
18-36
36-75
3.3 / 5 4A / 4A (total 8A)(12) 3416
3.3 / 5 4A / 4A (total 8A)(12) 1689
3.3 / 5 4A / 4A (total 8A)(12) 823
85
86
88
11000 / 6800
11000 / 6800
11000 / 6800
RP40-123.312TG
RP40-123.315TG
RP40-120512TG
RP40-120515TG
RP40-243.312TG
RP40-243.315TG
RP40-240512TG
RP40-240515TG
RP40-483.312TG
RP40-483.315TG
RP40-480512TG
RP40-480515TG
9-18
9-18
9-18
9-18
3.3 / 12
3.3 / 15
5 / 12
6000 / 400
6000 / 300
6000 / 400
6000 / 300
6000 / 400
6000 / 300
6000 / 400
6000 / 300
6000 / 400
6000 / 300
6000 / 400
6000 / 300
3063
3000
4024
3963
1512
1481
1989
1958
747
84
84
86
86
85
85
87
87
86
86
88
88
13000 / 330
13000 / 110
6800 / 330
6800 / 110
13000 / 330
13000 / 110
6800 / 330
6800 / 110
13000 / 330
13000 / 110
6800 / 330
6800 / 110
5 / 15
18-36 3.3 / 12
18-36 3.3 / 15
18-36
18-36
5 / 12
5 / 15
36-75 3.3 / 12
36-75 3.3 / 15
732
36-75
36-75
5 / 12
5 / 15
982
967
Derating-Graph (Ambient Temperature)
RP40-4805SG
125
100
75
Natural Convection
50
25
0
-40 -25 -10 0
60 70 80 90 100
50
Ambient Temperature Range (°C)
Derating graphes are valid only for the shown part numbers. If you need detailed derating-information about a
part-number not shown here please contact our technical customer service at info@recom-development.at
21-July-2005
www.recom-international.com
254
POWERLINE
RP40-S_D_TG
Series
DC/DC-Converter
Typical Characteristics
RP40-4805SG
RP40-4805SG
Efficiency VS Input Voltage
Efficiency VS Output Load
92
91
90
89
88
87
86
85
84
83
82
94
92
90
88
86
84
82
80
75
70
65
1
2
3
4
5
6
7
8
36 42
48
54 60
66 72
75
Output Load (A)
Input Voltage (V)
Specifications (typical at nominal input and 25°C unless otherwise noted)
Input Voltage Range
12V nominal input
24V nominal input
48V nominal input
9-18VDC
18-36VDC
36-75VDC
Under Voltage Lockout
12V input DC-DC ON
DC-DC OFF
9VDC
8VDC
24V input DC-DC ON
DC-DC OFF
48V input DC-DC ON
DC-DC OFF
17.8VDC
16VDC
36VDC
34VDC
Input Filter (see note 1)
L-C Type
Input Voltage Variation dv/dt
Input Surge Voltage (100 ms max.)
(Complies with ETS300 132 part 4.4)
5V/ms max
12V Input
24V Input
48V Input
36VDC
50VDC
100VDC
Input Reflected Ripple (nominal Vin and full load see note 3)
40mAp-p
Start Up Time (nominal Vin and constant resistor load)
Remote ON/OFF (see note 7)
25ms typ.
DC-DC ON
DC-DC OFF
Nominal input
Open or 3.5V < Vr < 12V
Short or 0V < Vr < 1.2V
2.5mA
Remote OFF input current
Output Power
40W max.
Output Voltage Accuracy (full Load and nominal Vin)
Single & Dual
Triple Main
Auxiliary
1%
1%
5%
Voltage Adjustability
Minimum Load
10%
Single and Dual Positive
Dual and Triple
0%
10% of FL
Line Regulation (LL-HL at full load)
Single & Dual
Triple Main
0.5%
1%
Triple Auxiliary
5%
continued on next page
21-July-2005
www.recom-international.com
255
POWERLINE
RP40-S_D_TG
Series
DC/DC-Converter
Specifications (typical at nominal input and 25°C unless otherwise noted)
Load Regulation (10% to 100% FL see note 9 and 10)
Single
Dual
0.5%
1%
Triple Main
Auxiliary
2%
5%
Cross Regulation (Note 11)
Triple Main
1%
Dual / Triple Auxiliary
5%
Ripple and Noise (20MHz bandwith)
(Measured with a 1004pF/50V MLCC)
Single 1.5, 1.8, 2.5, 3.3, 5V
Single 12, 15V
Dual 12V
Dual 15V
RP40-xx3.305DG
RP40-xxxxxxTG
50mVp-p
75mVp-p
120mVp-p
150mVp-p
100mVp-p
50 / 75mVp-p
Temperature Coefficient
0.02%/°C, max.
Transient Response (25% load step change)
300µS
Over Voltage Protection
Zener diode clamp (only single)
1.5, 1.8, 2.5, 3.3V
5V
12V
3.9V
6.2V
15V
15V
18V
Over Load Protection (% of full load at nominal Vin)
Short Circuit Protection
Efficiency
150% max.
Hiccup, automatic recovery
see „Selection Guide“ table
1.600VDC min.
Isolation Voltage
Isolation Resistance
109 Ω min.
Isolation Capacitance
1000pF max.
Operating Frequency
300kHz typ.
Approved to Safety Standards
Single,Triple
Dual
UL 1950, EN60950
EN60950
Operating Temperature Range
Maximum Case Temperature
-40°C to +85°C(with derating)
100°C
Storage Temperature Range
-55°C to +105°C
Thermal Impedance (see note 8)
Natural convection
Heat Sink with 20LFM
Heat Sink with 500LFM
9.2°C/Watt
8.5°C/Watt
2.8°C/Watt
Thermal Shock
Vibration
MIL-STD-810D
10-55Hz, 2G, 30 Min. along X, Y and Z
5% to 95% RH
Relative Humidity
Case Material
Base Material
Potting Material
Nickel-Coated copper
Non-conductive black plastic FR4
Epoxy (UL94-V0)
Conducted Emissions
Radiated Emissions
ESD
Radiated Immunity
Fast Transient
Surge
EN55022
EN55022
Level A
Level A
EN61000-4-2
EN61000-4-3
EN61000-4-4
EN61000-4-5
EN61000-4-6
Perf. Criteria 2
Perf. Criteria 2
Perf. Criteria 2
Perf. Criteria 2
Perf. Criteria 2
Conducted Immunity
Weight
60g
50.8 x 50.8 x 10.2mm
1.398 x 106 Hours
Dimensions
MTBF (see note 2)
256
21-July-2005
www.recom-international.com
POWERLINE
RP40-S_D_TG
Series
DC/DC-Converter
Notes :
1. Maximum output deviation is 10% inclusive of remote sense and trim. If remote sense is not being used, the +Vsense should be connected to its
corresponding +OUTPUT and likewise the sense should be connected to its corresponding -OUTPUT
2. BELLCORE TR-NWT-000332. Case l: 50% Stress, Temperature at 40°C (Ground fixed and controlled environment).
3. Simulated source impedance of 12uH. 12uH inductor in series with +Vin.
4. Maximum value at nominal input voltage and full load of standard type.
5. Typical value at nominal input voltage and full load.
6. Test by minimum Vin and constant resistor load.
7. The ON/OFF control pin voltage is referenced to negative input.
8. Heat sink is optional and P/N: 7G-0026A.
9. The triple output required a minimum 10% loading on the output to maintain specified regulation. Operation under no-load condition will not
damage these devices,however they may not meet all listed specification.
10. Load regulation for triple output:
Main output(V1):10 to 100% with 10% to 100% balanced on auxiliaries.
Auxiliary outputs(V2 and V3):10% to 100% balanced on all outputs.
11.Cross regulation for triple output:
Main output 100% load, auxiliary 100%,other auxiliary25% to 100%.
Auxiliary outputs(V2 and V3):main output 100% load, auxiliary 100%, other auxiliary
25% to 100% or main output 25%,auxiliary 25%,other auxiliary 25% to 100%.
12.The models of RP40-XX3.305DG are specified with a 1uF ceramic output capacitors.
13.An external filter capacitor is required for normal operation. The capacitor should be capable of handing 1A ripple current for 48V/24V models.
RECOM suggest: Nippon chemi-con KMF series, 220µF/100V, ESR 90m Ω.
14.Operating frequency for dual output: master (5Vo) 300KHz slave (3.3Vo) 500KHz.
15.Any condition of dual output (3.3V/5V) rated Iout current, not to exceed 8A of total
output currents. The product safety approval pending.
16.See application notes for EMI-filtering.
Package Style and Pinning (mm)
3rd angle
projection
50.80
50.80
10.20
0.70
dia.
1.0
5.6
Pin Connections
Pin #
Single
+Vin
-Vin
CTRL
NC
Dual
+Vin
-Vin
CTRL
No Pin
Triple
+Vin
-Vin
CTRL
+Aux
Com
Dual Positive
1
2
3
4
5
6
7
8
9
+Vin
-Vin
CTRL
3.3V
45.70
-Sense (Note1) +Vout
+Sense (Note1)
+Vout
3.3V RTN(Com)
4
5
Com
Com
-Vout
Trim
-Aux
NC
NC
5V
+Vout
-Vout(Com)
NC
12.70
-Vout
Trim
2.5
5V RTN(Com)
5.10
1
2
NC = No Connection
Pin Pitch Tolerance 0.35 mm
6
7
5.10
10.20
7.6
15.20
Bottom View
20.30
External Output Trimming
8
9
3
28.20
Output can be externally trimmed by using the method
shown below.
( ) for dual output trim
Trim Up
Trim Down
8(8)
9(9)
9(9)
7(5)
R
R
D
U
21-July-2005
www.recom-international.com
257
相关型号:
©2020 ICPDF网 联系我们和版权申明