RP40-2415SG-HC [ETC]

CONV DC/DC 40W 18-36VIN 15VOUT;
RP40-2415SG-HC
型号: RP40-2415SG-HC
厂家: ETC    ETC
描述:

CONV DC/DC 40W 18-36VIN 15VOUT

文件: 总9页 (文件大小:628K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
• 2:1 input voltage range  
• 1.6kVDC isolation  
Features  
DC/DC Converter  
• UL certified  
• Efficiency up to 90%  
Regulated  
Converter  
• Six-sided continuous shield  
• Available as power module (RPM40-G)  
RP40-G  
Description  
40 Watt  
2” x 2”  
The RP40-G series DC/DC converters are certified to UL 60950-1 and to cUL 60950-1. This makes  
them ideal for all telecom and industrial applications where approved safety standards are required. The  
industry standard 2” x 2” package meets military standards for thermal shock and vibration tolerance.  
Single, Dual and  
Triple Output  
Selection Guide  
Part Number  
Input  
Output  
Output  
Current  
[mA]  
Input (1) Efficiency (1) Max. Capacitive  
Voltage Range Voltage  
Current  
[mA]  
typ.  
[%]  
Load (2)  
[µF]  
[VDC]  
9-18  
9-18  
9-18  
9-18  
18-36  
18-36  
18-36  
18-36  
36-75  
36-75  
36-75  
36-75  
9-18  
[VDC]  
3.3  
5
12  
15  
3.3  
5
12  
15  
3.3  
5
12  
15  
12  
15  
12  
15  
12  
15  
RP40-123.3SG (3)  
RP40-1205SG (3)  
RP40-1212SG (3)  
RP40-1215SG (3)  
RP40-243.3SG (3)  
RP40-2405SG (3)  
RP40-2412SG (3)  
RP40-2415SG (3)  
RP40-483.3SG (3)  
RP40-4805SG (3)  
RP40-4812SG (3)  
RP40-4815SG (3)  
RP40-1212DG (3)  
RP40-1215DG (3)  
RP40-2412DG (3)  
RP40-2415DG (3)  
RP40-4812DG (3)  
RP40-4815DG (3)  
RP40-120512TG (3)  
RP40-120515TG (3)  
RP40-240512TG (3)  
RP40-240515TG (3)  
RP40-480512TG (3)  
RP40-480515TG (3)  
8000  
8000  
3333  
2666  
8000  
8000  
3333  
2666  
8000  
8000  
3333  
2666  
1800  
1400  
1800  
1400  
1800  
1400  
2558  
3876  
3876  
3830  
1264  
1873  
1894  
1872  
625  
86  
86  
86  
87  
87  
89  
88  
89  
88  
90  
89  
89  
85  
85  
87  
87  
87  
87  
86  
86  
87  
87  
88  
88  
21000  
13600  
2360  
1510  
21000  
13600  
2360  
1510  
21000  
13600  
2360  
1510  
1200  
750  
1200  
750  
1200  
926  
936  
936  
4235  
4118  
2069  
2011  
1034  
1006  
3837  
3779  
1897  
1868  
938  
E196683  
9-18  
18-36  
18-36  
36-75  
36-75  
9-18  
750  
UL60950-1 certified  
5/ 12 6000/ 400  
5/ 15 6000/ 300  
5/ 12 6000/ 400  
5/ 15 6000/ 300  
5/ 12 6000/ 400  
5/ 15 6000/ 300  
6800/ 330  
6800/ 110  
6800/ 330  
6800/ 110  
6800/ 330  
6800/ 110  
9-18  
18-36  
18-36  
36-75  
36-75  
923  
Notes:  
Note1: Maximum values at nominal input voltage and full load of standard type  
Note2: Max. Cap load is tested at minimum Input and constant resistive load  
Model Numbering  
RP40-__ __ G- _  
(3)  
“Package  
nom. Input Voltage  
Output Voltage  
Single, Dual or Triple  
Notes:  
Note3: add suffix “-HC” for premounted Heat-sink with clips  
Ordering Examples  
RP40-2405SG = 24V Input, 5V Output, Single  
RP40-4812DG-HC = 48V Input, 12V Output, Dual, Heat-sink premounted  
www.recom-power.com  
REV.: 3/2019  
PD-1  
RP40-G  
DC/DC Converter  
Specifications (measured @ Ta= 25°C, nom. Vin, full load unless otherwise stated)  
Series  
BASIC CHARACTERISTICS  
Parameter  
Condition  
Min.  
Typ.  
Max.  
Input Filter  
LC Type  
nom. Vin = 12VDC  
nom. Vin = 24VDC  
nom. Vin = 48VDC  
9VDC  
18VDC  
36VDC  
12VDC  
24VDC  
48VDC  
18VDC  
36VDC  
75VDC  
36VDC  
50VDC  
100VDC  
9VDC  
Input Voltage Range  
Input Surge Voltage  
nom. Vin = 12VDC  
nom. Vin = 24VDC  
nom. Vin = 48VDC  
DC-DC ON  
100ms max.  
nom. Vin = 12VDC  
nom. Vin = 24VDC  
nom. Vin = 48VDC  
DC-DC OFF  
8VDC  
16VDC  
34VDC  
DC-DC ON  
DC-DC OFF  
17.8VDC  
36VDC  
+10%  
Under Voltage Lockout (UVLO)  
DC-DC ON  
DC-DC OFF  
Output Voltage Trimming (4)  
refer to “OUTPUT VOLTAGE TRIMMING“  
-10%  
Input Reflected Ripple Current (5)  
40mAp-p  
Single  
Dual and Triple  
0%  
10%  
Minimum Load (6)  
Power up  
ON/OFF CTRL  
25ms  
25ms  
Start-up Time  
V
Open or 3.0VDC < CTRL< 12VDC  
DC-DC ON  
DC-DC OFF  
ON/OFF CTRL (7)  
Positive Logic  
V
Short or 0VDC < CTRL< 1.2VDC  
DC-DC ON  
DC-DC OFF  
-0.5mA  
270kHz  
+0.5mA  
2.5mA  
Input Current of CTRL pin  
Standby Current  
Internal Operating Frequency  
300kHz  
330kHz  
3.3Vout, 5Vout  
12Vout, 15Vout  
50mVp-p  
75mVp-p  
Single  
Dual  
measured at 20MHz BW  
with a 0.1µF/50V MLCC  
12Vout  
15Vout  
120mVp-p  
150mVp-p  
Ripple and Noise  
5Vout  
12Vout, 15Vout  
50mVp-p  
75mVp-p  
Triple  
Notes:  
Note4: For the single output: Maximum output deviation is 10% inclusive of remote sense and trim. If remote sense is not being used,  
the +Sense should be connected to its corresponding +Vout and likewise the -Sense should be connected to its corresponding -Vout  
Note5: Simulated source impedance of 12µH. 12µH inductor in series with +Vin  
Note6: The dual and triple output required a minimum loading on the output to maintain specified regulation. Operation under  
no-load condition will not damage these devices, however they may not meet all listed specification  
Note7: The pin voltage is referenced to -Vin pin  
RP40-1205SG  
Efficiency vs. Output Current  
Efficiency vs. Input Voltage  
90  
85  
80  
75  
70  
65  
60  
95  
90  
85  
80  
75  
70  
65  
60  
55  
50  
45  
9Vin  
12Vin  
18Vin  
40  
10  
9
10  
11  
12  
13  
14  
15  
16  
17  
18  
20  
30  
40  
50  
60  
70  
80  
90  
100  
Output Current [%]  
Input Voltage [VDC]  
continued on next page  
www.recom-power.com  
REV.: 3/2019  
PD-2  
RP40-G  
DC/DC Converter  
Specifications (measured @ Ta= 25°C, nom. Vin, full load unless otherwise stated)  
Series  
RP40-2405SG  
Efficiency vs. Output Current  
Efficiency vs. Input Voltage  
95  
90  
95  
90  
85  
80  
75  
70  
65  
60  
55  
85  
80  
75  
70  
65  
60  
18Vin  
24Vin  
36Vin  
50  
45  
40  
10  
9
10  
11  
12  
13  
14  
15  
16  
17  
18  
20  
30  
40  
50  
60  
70  
80  
90  
100  
Output Current [%]  
Input Voltage [VDC]  
RP40-4805SG  
Efficiency vs. Output Current  
Efficiency vs. Input Voltage  
95  
90  
85  
80  
75  
70  
65  
60  
95  
90  
85  
80  
75  
70  
65  
60  
55  
36Vin  
48Vin  
75Vin  
50  
45  
40  
10  
40  
20  
30  
50  
60  
70  
80  
90  
100  
36  
40  
44  
48  
52  
56  
60  
64  
68  
72  
75  
Output Current [%]  
Input Voltage [VDC]  
OUTPUT VOLTAGE TRIMMING  
Output Voltage Trimming  
Some single/dual output Powerline converters offer the feature of trimming the output voltage over a certain range around the nominal value by  
using external trim resistors. No general equation can be given for calculating the trim resistors, but the following trimtables give typical values for  
choosing these trimming resistors. If voltages between the given trim points are required, extrapolate between the two nearest given values to work  
out the resistor required or use a variable resistor to set the output voltage. Output can be externally trimmed by using the method shown below.  
Trim up  
Trim down  
-Sense  
Trim  
or -Vout  
R
R
U
D
+Sense  
Trim  
or +Vout  
RP40-xx3.3SG  
[%]  
[VDC]  
[kW]  
Trim up  
1
2
3
4
5
6
7
8
9
10  
Vout =  
RU =  
3.333  
57.93  
3.366  
26.16  
3.399  
15.58  
3.432  
10.28  
3.465  
7.11  
3.498  
3.531  
3.48  
3.564  
2.34  
3.597  
1.46  
3.63  
0.75  
4.99  
[%]  
[VDC]  
[kW]  
Trim down  
Vout =  
RD =  
1
2
3
4
5
6
7
8
9
10  
3.267  
69.47  
3.234  
31.23  
3.201  
18.49  
3.168  
12.12  
3.135  
8.29  
3.102  
5.74  
3.069  
3.92  
3.036  
2.56  
3.003  
1.50  
2.97  
0.65  
continued on next page  
www.recom-power.com  
REV.: 3/2019  
PD-3  
RP40-G  
DC/DC Converter  
Specifications (measured @ Ta= 25°C, nom. Vin, full load unless otherwise stated)  
Series  
RP40-xx05SG  
[%]  
[VDC]  
[kW]  
Trim up  
Vout =  
RU =  
1
2
3
4
5
6
7
8
9
10  
5.05  
36.57  
5.10  
16.58  
5.15  
9.92  
5.20  
6.58  
5.25  
4.59  
5.30  
3.25  
5.35  
2.30  
5.4  
5.45  
1.03  
5.50  
0.59  
1.59  
[%]  
[VDC]  
[kW]  
Trim down  
Vout =  
RD =  
1
2
3
4
5
6
7
8
9
10  
4.95  
45.53  
4.90  
20.61  
4.85  
12.31  
4.80  
8.15  
4.75  
5.66  
4.70  
4.00  
4.65  
2.81  
4.60  
1.92  
4.55  
1.23  
4.50  
0.68  
RP40-xx12SG  
[%]  
[VDC]  
[kW]  
Trim up  
1
2
3
4
5
6
7
8
9
10  
Vout =  
RU =  
12.12  
12.24  
165.95  
12.36  
98.64  
12.48  
64.98  
12.60  
44.78  
12.72  
31.32  
12.84  
21.70  
12.96  
14.49  
13.08  
8.88  
13.20  
4.39  
367.91  
[%]  
[VDC]  
[kW]  
Trim down  
Vout =  
RD =  
1
2
3
4
5
6
7
8
9
10  
11.88  
460.99  
11.76  
207.95  
11.64  
123.60  
11.52  
81.42  
11.40  
56.12  
11.28  
39.25  
11.16  
27.20  
11.04  
18.16  
10.92  
11.13  
10.8  
5.51  
RP40-xx15SG  
[%]  
[VDC]  
[kW]  
Trim up  
1
2
3
4
5
6
7
8
9
10  
Vout =  
RU =  
15.15  
15.3  
15.45  
106.06  
15.60  
68.80  
15.75  
46.44  
15.90  
31.53  
16.05  
20.88  
16.20  
12.90  
16.35  
6.69  
16.50  
1.72  
404.18  
180.59  
[%]  
[VDC]  
[kW]  
Trim down  
Vout =  
RD =  
1
2
3
4
5
6
7
8
9
10  
14.85  
499.82  
14.70  
223.41  
14.55  
131.27  
14.40  
85.20  
14.25  
57.56  
14.10  
39.14  
13.95  
25.97  
13.80  
16.10  
13.65  
8.42  
13.50  
2.282  
RP40-xx12DG  
[%]  
[VDC]  
[kW]  
Trim up  
1
2
3
4
5
6
7
8
9
10  
Vout =  
RU =  
24.24  
24.48  
98.10  
24.72  
58.07  
24.96  
38.05  
25.20  
26.04  
25.44  
18.03  
25.68  
12.32  
25.92  
8.03  
26.16  
4.69  
26.40  
2.02  
218.21  
[%]  
[VDC]  
[kW]  
Trim down  
Vout =  
RD =  
1
2
3
4
5
6
7
8
9
10  
23.76  
273.44  
23.52  
123.02  
23.28  
72.87  
23.04  
47.80  
22.80  
32.76  
22.56  
22.73  
22.32  
15.57  
22.08  
10.20  
21.84  
6.02  
21.6  
2.67  
RP40-xx15DG  
[%]  
[VDC]  
[kW]  
Trim up  
1
2
3
4
5
6
7
8
9
10  
Vout =  
RU =  
30.30  
30.60  
120.64  
30.90  
71.43  
31.20  
46.82  
31.50  
32.06  
31.80  
22.21  
32.10  
15.10  
32.40  
9.91  
32.70  
5.81  
33.00  
2.53  
268.29  
[%]  
[VDC]  
[kW]  
Trim down  
Vout =  
RD =  
1
2
3
4
5
6
7
8
9
10  
29.70  
337.71  
29.40  
152.02  
29.10  
90.13  
28.80  
59.18  
28.50  
40.61  
28.20  
28.23  
27.90  
19.39  
27.60  
12.76  
27.30  
7.60  
27.00  
3.47  
www.recom-power.com  
REV.: 3/2019  
PD-4  
RP40-G  
DC/DC Converter  
Specifications (measured @ Ta= 25°C, nom. Vin, full load unless otherwise stated)  
Series  
REGULATIONS  
Parameter  
Condition  
Single, Dual  
Triple Main  
Value  
1.0% max.  
1.0% max.  
5.0% max.  
0.5% max.  
1.0% max.  
5.0% max.  
0.5% max.  
1.0% max.  
Output Accuracy  
Triple Auxiliary  
Single, Dual  
Triple Main  
Triple Auxiliary  
Single  
Line Regulation  
Load Regulation  
low line to high line, full load  
min. load to full load  
Dual  
10% to 100% balanced on auxiliaries  
Triple Main  
2.0% max.  
5.0% max.  
5.0% max.  
10% to 100% balanced on all outputs Triple Auxiliary  
asymmetrical 25%/100% FL  
Dual  
Triple: main output (5Vout)  
100%load, auxiliary 100%,  
other auxiliary 25% to 100% load or  
main output (5Vout) 25%, auxiliary  
25%, other auxiliary 25% to 100%  
Triple Main  
1.0% max.  
Cross Regulation  
Triple Auxiliary  
5.0% max.  
250µs typ.  
Transient Response Recovery Time  
25% load step change  
PROTECTIONS  
Parameter  
Condition  
Value  
Short Circuit Protection (SCP)  
continuous, automatic recovery  
3.3Vout  
3.9VDC  
6.2VDC  
15VDC  
18VDC  
5Vout  
12Vout  
15Vout  
Over Voltage Protection (OVP)  
zener diode clamp  
Over Load Protection (OLP)  
% of Iout rated  
150% typ.  
115°C typ.  
Over Temperature Protection (OTP)  
I/P to O/P  
I/P to O/P to case  
Viso= 500VDC  
1.6kVDC/ 1 minute  
1.6kVDC/ 1 minute  
Isolation Voltage(8)  
Isolation Resistance  
Isolation Capacitance  
1GW min.  
1000pF max.  
Notes:  
Note8: For repeat Hi-Pot testing, reduce the time and/or the test voltage  
Note9: This power module is not internally fused. An input line fuse must always be used  
ENVIRONMENTAL  
Parameter  
Condition  
Value  
without derating  
with derating  
-40°C to +66°C  
-40°C o +100°C  
Operating Temperature Range  
Maximum Case Temperature  
Temperature Coefficient  
+100°C max.  
0.02%/ꢀ max.  
@ natural convection  
0.1m/s  
without heat-sink  
with heat-sink  
9.2ꢀ/W  
7.6ꢀ/W  
Thermal Impedance  
Operating Humidity  
non-condensing  
5% - 95% RH  
continued on next page  
REV.: 3/2019  
www.recom-power.com  
PD-5  
RP40-G  
DC/DC Converter  
Specifications (measured @ Ta= 25°C, nom. Vin, full load unless otherwise stated)  
Series  
Parameter  
Thermal Shock  
Vibration  
Condition  
Value  
according to MIL-STD-810F  
according to MIL-STD-810F  
MIL-HDBꢀ-217F, G.B.  
Bellcore TR-NWT-000332 (10)  
9224 x 102 hours  
1398 x 10³ hours  
MTBF  
Derating Graph (11)  
RP40-483.3SG  
RP40-483.3SG with Heat-sink  
100  
80  
60  
40  
20  
0
100  
80  
60  
40  
20  
0
-40 -20  
0
20 40  
60  
66  
80 100 120  
-40 -20  
0
20 40  
60 80 100 120  
73  
Ambient Temperature [°C]  
Ambient Temperature [°C]  
Notes:  
Note10: BELLCORE TR-NWT-000332. Case l: 50% Stress, Temperature at 40°C (Ground fixed and controlled environment)  
Note11: Derating graphs are valid only for the shown part numbers. If you need detailed derating-information about a part-number  
not shown here please contact RECOM Techsupport for detailed information  
SAFETY AND CERTIFICATIONS  
Certificate Type (Safety)  
Condition  
E196683  
Standard  
UL60950-1, 1st Edition  
CAN/CSA-C22.2 No. 60950-1, 1st Edition  
Information Technology Equipment, General Requirements for Safety  
EAC  
RU-AT.49.09571  
TP TC 004/2011  
RoHS2  
RoHS-2011/65/EU + AM-2015/863  
EMC Compliance  
Condition  
Standard / Criterion  
Electromagnetic compatibility of multimedia equipment - Emission  
requirements  
with external filter  
(see filter suggestion below)  
EN55032, Class A and B  
ESD Electrostatic discharge immunity test  
Radiated, radio-frequency, electromagnetic field immunity test  
Fast Transient and Burst Immunity (12)  
Surge Immunity (12)  
Air 8kV and Contact 6kV  
EN61000-4-2, Criteria B  
EN61000-4-3, Criteria A  
EN61000-4-4, Criteria B  
EN61000-4-5, Criteria B  
EN61000-4-6, Criteria A  
EN61000-4-8, Criteria A  
10 V/m  
2kV  
1kV  
10 Vr.m.s  
Immunity to conducted disturbances, induced by radio-frequency fields  
Power Magnetic Field Immunity  
100A/m continuous; 1000A/m 1s  
Notes:  
Note12: An external input filter capacitor is required if the module has to meet EN61000-4-4, EN61000-4-5  
The filter capacitor Recom suggests: Nippon chemi-con ꢀY series 220µF/100V  
www.recom-power.com  
REV.: 3/2019  
PD-6  
RP40-G  
DC/DC Converter  
Specifications (measured @ Ta= 25°C, nom. Vin, full load unless otherwise stated)  
Series  
EMC Filtering Suggestions according to EN55032  
Single  
Dual  
C3  
C3  
F1  
F1  
+Vin  
-Vin  
+Vout  
+Vin  
-Vin  
+Vout  
Com  
-Vout  
+Vin  
-Vin  
+Vout  
+Vin  
-Vin  
+Vout  
C1 C2  
C1 C2  
Com  
-Vout  
-Vout  
-Vout  
C4  
C4  
Triple  
C3  
F1  
+Vout  
+Vin  
-Vin  
+Vout  
+Aux  
Com  
-Aux  
C1 C2  
Com  
-Vin  
C4  
Component List Class A  
MODEL  
C1  
C2  
C3/C4  
RP40-12xxSG, RP40-12xxDG  
RP40-12xxTG  
6.8µF/50V, 1812 MLCC  
6.8µF/50V, 1812 MLCC  
2.2µF/100V, 1812 MLCC  
N/A  
1000pF/2kV, 1808 MLCC  
1000pF/2kV, 1808 MLCC  
1000pF/2kV, 1808 MLCC  
RP40-24xxSG, RP40-24xxDG  
RP40-24xxTG  
N/A  
N/A  
RP40-48xxSG, RP40-48xxDG  
RP40-48xxTG  
Dual  
Single  
C5  
C5  
L1  
L1  
F1  
F1  
+Vin  
-Vin  
+Vout +Vin  
+Vout  
Com  
-Vout  
+Vin  
+Vout  
+Vin  
+Vout  
C1 C2  
C3 C4  
C1 C2  
C3 C4  
Com  
-Vout  
-Vin  
-Vout  
-Vin  
-Vout  
-Vin  
C6  
C6  
Triple  
C5  
L1  
F1  
+Vin  
+Vout  
Com  
+Vin  
C1 C2  
C3 C4  
-Vin  
-Vin  
C6  
Component List Class B  
MODEL  
C1  
C2  
C3  
C4  
N/A  
C5/C6  
L1  
RP40-12xxSG  
RP40-12xxDG  
RP40-12xxTG  
4.7µF/50V  
1812 MLCC  
4.7µF/50V  
1812 MLCC  
1000pF/2kV  
1808 MLCC  
CMC: 450µH  
ref.: WE 7448227005 or ref.: CMC-05  
N/A  
RP40-24xxSG  
RP40-24xxDG  
RP40-24xxTG  
6.8µF/50V  
1812 MLCC  
6.8µF/50V  
1812 MLCC  
1000pF/2kV  
1808 MLCC  
CMC: 450µH  
ref.: WE 7448227005 or ref.: CMC-05  
N/A  
N/A  
RP40-48xxSG  
RP40-48xxDG  
RP40-48xxTG  
2.2µF/100V  
1812 MLCC  
2.2µF/100V  
1812 MLCC  
6.8µF/50V  
1812 MLCC  
2.2µF/100V  
1812 MLCC  
1000pF/2kV  
1808 MLCC  
CMC: 830µH  
ref.: WE 744822301 or ref.: CMC-08  
www.recom-power.com  
REV.: 3/2019  
PD-7  
RP40-G  
DC/DC Converter  
Specifications (measured @ Ta= 25°C, nom. Vin, full load unless otherwise stated)  
Series  
DIMENSIONS and PHYSICAL CHARACTERISTICS  
Parameter  
Type  
Value  
case  
base  
nickel coated copper  
FR4 PCB  
Material  
potting  
epoxy (UL94-V0)  
without Heat-sink  
with Heat-sink  
50.8 x 50.8 x 10.2mm  
56.8 x 50.8 x 17.0mm  
Dimensions (LxWxH)  
Weight  
without Heat-sink  
with Heat-sink  
60.0g  
81.06g  
Dimension Drawing (mm)  
Pin Connections  
Pin #  
Single  
+Vin  
Dual  
+Vin  
-Vin  
Triple  
+Vin  
-Vin  
1
2
3
4
5
6
7
8
9
-Vin  
CTRL  
CTRL  
No Pin  
+Vout  
Com  
CTRL  
+AUX  
Com  
-AUX  
+Vout  
Com  
NC  
NC  
-Sense (5)  
+Sense (5)  
+Vout  
-Vout  
Com  
-Vout  
Trim  
Trim  
NC= No Connection  
Pin Pitch Tolerance 0.25mm  
xx.x = 0.5mm  
xx.xx = 0.25mm  
50.8  
50.8  
2.54  
0.1  
18 x 2.54= 45.72  
Ø 1.0  
Recommended Footprint Details  
2.54  
Ø1.3 +0.15/-0  
9
8
4
5
3
7
6
1
2
2
1
6
7
Bottom View  
Top View  
5
4
8
9
3
continued on next page  
REV.: 3/2019  
www.recom-power.com  
PD-8  
RP40-G  
DC/DC Converter  
Specifications (measured @ Ta= 25°C, nom. Vin, full load unless otherwise stated)  
Series  
Dimension Drawing (mm) with Heat-sink  
Pin Connections  
Pin #  
Single  
+Vin  
Dual  
+Vin  
-Vin  
Triple  
+Vin  
-Vin  
50.8  
1
2
3
4
5
6
7
8
9
-Vin  
CTRL  
CTRL  
No Pin  
+Vout  
Com  
CTRL  
+AUX  
Com  
-AUX  
+Vout  
Com  
NC  
NC  
-Sense (5)  
+Sense (5)  
+Vout  
-Vout  
Top View  
Heat-sink  
Com  
-Vout  
Trim  
Trim  
NC= No Connection  
Pin Pitch Tolerance 0.25mm  
xx.x = 0.5mm  
xx.xx = 0.25mm  
56.8  
50.0  
2.54  
18 x 2.54= 45.72  
Ø 1.0  
PACKAGING INFORMATION  
Parameter  
Type  
Value  
tube  
tray  
without heat-sink  
with heat-sink  
255.0 x 54.0 x 22.0mm  
306.0 x 226.0 x 30.0mm  
Packaging Dimension (LxWxH)  
tube  
tray  
without heat-sink  
with heat-sink  
4pcs  
12pcs  
Packaging Quantity  
Storage Temperature Range  
Storage Humidity  
-55°C to +125°C  
5% - 95% RH  
non-condensing  
The product information and specifications may be subꢀect to changes even without prior written notice.The product has been designed for various applications; its suitability lies in the responsibility of each customer. The  
products are not authorized for use in safety-critical applications without RECOMꢁs explicit written consent. A safety-critical application is an application where a failure may reasonably be expected to endanger or cause  
loss of life, inflict bodily harm or damage property. The applicant shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized  
use of RECOM products in such safety-critical applications.  
www.recom-power.com  
REV.: 3/2019  
PD-9  

相关型号:

RP40-2415SGW

40 Watt 2” x 2” Single & Dual Output
RECOM

RP40-2415SGW-HC

CONV DC/DC 40W 9-36VIN 15VOUT
ETC

RP40-2415SGW/N

DC DC CONVERTER 15V 40W
ETC

RP40-2415SGW/N-HC

CONV DC/DC 40W 9-36VIN 15VOUT
ETC

RP40-2415SGWN

40 Watt 2” x 2” Single & Dual Output
RECOM

RP40-242.5SG

40 Watt Single, Dual, Positive Dual & Triple Output
RECOM

RP40-2424DFR/N

CONV DC/DC 40W 9-36VIN +/-24VOUT
ETC

RP40-2424DFR/N-HC

CONV DC/DC 40W 9-36VIN +/-24VOUT
ETC

RP40-2424DFR/P

CONV DC/DC 40W 9-36VIN +/-24VOUT
ETC

RP40-2424SFR/N

CONV DC/DC 40W 9-36VIN 24VOUT TH
ETC

RP40-2424SFR/N-HC

CONV DC/DC 40W 9-36VIN 24VOUT TH
ETC

RP40-243.305DE

40 Watt Single, Dual, Positive Dual & Triple Output
RECOM