DC-AC INVERTER UNIT
CXA-M10A-L (6W SINGLE & DUAL OUTPUTS, PCB MOUNTABLE)
(STANDARD)
DESCRIPTION :
TDK DC/AC Inverter, CXA-series, are low-noise, high frequency
power sources developed for driving Cold Cathode Fluorescent
Lamps operating at 20~80 kHz. These inverters are designed to
handle a wide range of lamp characteristics.
FEATURES :
Constant current output ensures compatibility with a wide
range of discharge lamps.
High efficiency resonant circuitry produces low-noise,
sinusoidal-wave output.
One-lamp/two-lamp combined-use capability allows use in
four different configurations.
Common ground or floating bulb configurations.
Compact size and light weight facilitate PC board
mounting.
High Efficiency (80%)
TEMPERATURE & HUMDITY :
Operating Temperature Range
Storage Temperature Range
Humidity
-10 °C ~ +60°C
-20 °C ~ +85°C
95 %RH max (No dew)
DIMENSIONS :
3 Min
16.5 Max
29 Max
Unit :
mm
Weight: 21.0g typ.
20.32±0.2
2
1
Jumper
(*1)
Pin
1
Symbol
Vin
Note
0 ~ 6 Vdc
0 Vdc
2
GND
3
Iout1
Iout2
Iout-ret
4
5
3
4
5
(2)
5x 0.64±0.07
Bottom View
*1 Remove for Isolated Ground
Unit : mm
Power Systems – The Power Solution
Web:
Email:
www.Power-Systems.de
Info@Power-Systems.de
Address: Dörnet 8 ; 74360 Ilsfeld-Auenstein / Germany
Tel. :
Fax:
+ 49 / 70 62 / 67 59 - 6
+ 49 / 70 62 / 67 59 - 80
All specification are subject to change without notice.
Page ( 1 / 4 )
VER, 25 November 2003
DC-AC INVERTER UNIT
CXA-M10A-L (6W SINGLE & DUAL OUTPUTS, PCB MOUNTABLE)
(STANDARD)
CONNECTOR CONFIGURATION:
ABSOLUTE MAXIMUM RATINGS:
Pin No. Symbols
Ratings
5V
Items
Symbols Specification
Unit
VDC
W
Vin
GND
Vin
0~6.0
6
1
2
3
4
5
Input Voltage
Output Power
0V
Pout
OUT1
400Vrms
400Vrms
0V
OUT2
OUT GND
ELECTRICAL CHARACTERISTICS:
Conditions
Specification
Items
Symbols
Iout
Unit Connection
mArms
Vin [V] Ta [°C] RL [K
Min.
Typ.
10
Max.
Ω]
5±0.05
5±0.25
5±0.25
5±0.25
23±5
40
9
8
11
12
Output
Current
-10~60
-10~60
-10~60
30~50
30~50
30~50
10
-
1000
28
1500
33
Input Current
Frequency
Iin
F
mA DC
1
23
kHz
Open Circuit
Voltage
5±0.25
-10~60
1000
1200
-
Vopen
Iout
Vrms
∞
5±0.05
5±0.25
5±0.25
5±0.25
23±5
67
5.1
4.5
-
6
6
6.5
7.1
Output
Current
mArms
-10~60
-10~60
-10~60
50~84
50~84
50~84
600
32
1000
37
Input Current
Iin
F
mA DC
2
27
Frequency
Open Circuit
Voltage
kHz
5±0.25
-10~60
1000
1200
-
Vopen
Iout
Vrms
∞
5±0.05
5±0.25
5±0.25
5±0.25
23±5
80
4.2
3.7
-
5
5
5.4
5.9
900
33
Output
Current
mArms
-10~60
-10~60
-10~60
60~100
60~100
60~100
600
28
Input Current
Frequency
Iin
F
mA DC
3
23
kHz
Open Circuit
Voltage
5±0.25
-10~60
1000
1200
-
Vopen
Vrms
∞
5±0.05
5±0.25
5±0.25
5±0.25
23±5
80
4.5/4.5
5/5
5/5
5.5/5.5
6/6
Output
Current
Iout1 /
Iout2
mArms
-10~60
-10~60
-10~60
60~100
60~100
60~100
4/4
-
1000
28
1500
33
Input Current
Frequency
Iin
F
mA DC
4
23
kHz
Open Circuit
Voltage
5±0.25
-10~60
1000
1200
-
Vopen
Vrms
∞
Power Systems – The Power Solution
Web:
Email:
www.Power-Systems.de
Info@Power-Systems.de
Address: Dörnet 8 ; 74360 Ilsfeld-Auenstein / Germany
Tel. :
Fax:
+ 49 / 70 62 / 67 59 - 6
+ 49 / 70 62 / 67 59 - 80
All specification are subject to change without notice.
Page ( 2 / 4 )
VER, 25 November 2003
DC-AC INVERTER UNIT
CXA-M10A-L (6W SINGLE & DUAL OUTPUTS, PCB MOUNTABLE)
(STANDARD)
APPLICATION
Connection 1
Connection 3
Pin1 (Vin)
Pin3 (out1)
Pin4 (out2)
Pin1 (Vin)
Pin3 (out1)
Pin4 (out2)
CCFL
CCFL
Vin
Vin
Pin2 (GND) Pin5 (out GND)
Pin2 (GND) Pin5 (out GND)
Connection 2
Connection 4
Pin1 (Vin)
Pin3 (out1)
Pin4 (out2)
Pin1 (Vin)
Pin3 (out1)
Pin4 (out2)
CCFL2
CCFL
CCFL1
Vin
Vin
Pin2 (GND) Pin5 (out GND)
Pin2 (GND) Pin5 (out GND)
Note 1.
Note 2.
For circuit connection, please prefer to test circuit diagram.
Please use minimum of 2mm clearance (all directions) between inverter high voltage area and any
conductors. Please refer to mechanical drawing for marking of high voltage area.
Note 3.
Note 4.
Open voltage (strike voltage) is measured across the transformer secondary winding at no load as the
reading at the output connector would be less than the actual value.
If the start up voltage falls below Cold Cathode Tube strike voltage, the CCFL will not light up easily
specially at lower ambient temperature. Please review mounting instruction to avoid any abnormal
operation due to coupling/leakage capacitance of inverter high voltage area to any surrounding conductor.
Note 5.
Note 6.
For operation in floating mode, please remove jumper (J1) on top side of PCB that pin2 and pin5.
To prevent electrical discharge from high voltage area, please use non-conductive fastener in U mounting
hole.
Power Systems – The Power Solution
Web:
Email:
www.Power-Systems.de
Info@Power-Systems.de
Address: Dörnet 8 ; 74360 Ilsfeld-Auenstein / Germany
Tel. :
Fax:
+ 49 / 70 62 / 67 59 - 6
+ 49 / 70 62 / 67 59 - 80
All specification are subject to change without notice.
Page ( 3 / 4 )
VER, 25 November 2003
DC-AC INVERTER UNIT
CXA-M10A-L (6W SINGLE & DUAL OUTPUTS, PCB MOUNTABLE)
(STANDARD)
TEST CIRCUIT
Power Systems – The Power Solution
Web:
Email:
www.Power-Systems.de
Info@Power-Systems.de
Address: Dörnet 8 ; 74360 IlsfeAuenstein / Gany
Tel. :
Fax:
+ 49 / 70 62 / 67 59 - 6
+ 49 / 70 62 / 67 59 - 80
All specification are subject to change without notice.
Page ( 4 / 4 )
VER, 25 Novembe03