CXA-M10L-L [POWER-SYSTEMS]
DC-AC INVERTER UNIT 6W SINGLE & DUAL OUTPUTS, PCB MOUNTABLE; DC -AC逆变单元6W单,双输出, PCB MOUNTABLE型号: | CXA-M10L-L |
厂家: | POWER SYSTEMS GMBH+CO.KG |
描述: | DC-AC INVERTER UNIT 6W SINGLE & DUAL OUTPUTS, PCB MOUNTABLE |
文件: | 总4页 (文件大小:128K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
DC-AC INVERTER UNIT
(STANDARD)
CXA-M10L-L (6W SINGLE & DUAL OUTPUTS, PCB MOUNTABLE)
DESCRIPTION :
TDK DC/AC Inverter, CXA-series, are low-noise, high frequency
power sources developed for driving Cold Cathode Fluorescent
Lamps operating at 20~80 kHz. These inverters are designed to
handle a wide range of lamp characteristics.
FEATURES :
Constant current output ensures compatibility with a wide
range of discharge lamps.
High efficiency resonant circuitry produces low-noise,
sinusoidal-wave output.
One-lamp/two-lamp combined-use capability allows use in
four different configurations.
Common ground or floating bulb configurations.
Compact size and light weight facilitate PC board
mounting.
High Efficiency (80%)
TEMPERATURE & HUMDITY :
Operating Temperature Range
-10 °C ~ +60°C
Storage Temperature Range -20 °C ~ +85°C
Humidity
95 %RH max (No dew)
DIMENSIONS :
Unit :
Weight: 21.0g typ.
mm
3 Min
16.5 Max
29 Max
20.32±0.2
2
1
Jumper
(*1)
Pin
1
Symbol
Note
Vin
GND
Iout1
Iout2
Iout-ret
0 ~ 14,4 Vdc
0 Vdc
2
3
4
5
4
3
5
(2)
5x 0.64±0.07
Bottom View
*1 Remove for Isolated Ground
Unit : mm
Power Systems – The Power Solution
Web:
Email:
www.Power-Systems.de
Info@Power-Systems.de
Address: Dörnet 8 ; 74360 Ilsfeld-Auenstein / Germany
Tel. :
Fax:
+ 49 / 70 62 / 67 59 - 6
+ 49 / 70 62 / 67 59 - 80
All specification are subject to change without notice.
Page ( 1 / 4 )
VER, 25 November 2003
DC-AC INVERTER UNIT
(STANDARD)
CXA-M10L-L (6W SINGLE & DUAL OUTPUTS, PCB MOUNTABLE)
CONNECTOR CONFIGURATION:
ABSOLUTE MAXIMUM RATINGS:
Pin No. Symbols
Ratings
12V
Items
Symbols Specification
Unit
VDC
W
Vin
GND
Vin
0~14.4
6
1
2
3
4
5
Input Voltage
Output Power
0V
Pout
OUT1
400Vrms
400Vrms
0V
OUT2
OUT GND
ELECTRICAL CHARACTERISTICS:
Conditions
Specification
Items
Symbols
Iout
Unit
Connection
Vin [V] Ta [°C] RL [KΩ ]
Min.
Typ.
10
Max.
12±0.12
12±0.6
12±0.6
12±0.6
23±5
40
9
8
11
12
Output
mArms
Current
-10~60
-10~60
-10~60
30~50
30~50
30~50
10
Input Current
Frequency
Iin
F
-
420
28
630
33
mA DC
kHz
1
23
Open Circuit
Voltage
Vopen
Iout
12±0.6
-10~60
∞
1000
1200
-
Vrms
12±0.12
12±0.6
12±0.6
12±0.6
23±5
67
5.1
4.5
-
6
6
6.5
7.1
Output
mArms
Current
-10~60
-10~60
-10~60
50~84
50~84
50~84
Input Current
Frequency
Iin
F
270
31
410 mA DC
2
3
4
26
36
kHz
Open Circuit
Voltage
Vopen
Iout
12±0.6
-10~60
∞
1000
1200
-
Vrms
12±0.12
12±0.6
12±0.6
12±0.6
23±5
80
4.3
3.8
-
5
5
5.5
6.0
Output
mArms
Current
-10~60
-10~60
-10~60
60~100
60~100
60~100
Input Current
Frequency
Iin
F
230
28
350 mA DC
23
33
kHz
Open Circuit
Voltage
Vopen
12±0.6
-10~60
∞
1000
1200
-
Vrms
12±0.12
12±0.6
12±0.6
12±0.6
23±5
80
4.5/4.5
5/5
5/5
420
28
5.5/5.5
6/6
Output
Iout1 /
Iout2
mArms
Current
-10~60
-10~60
-10~60
60~100
60~100
60~100
4/4
-
Input Current
Iin
F
630 mA DC
Frequency
Open Circuit
Voltage
23
33
kHz
Vopen
12±0.6
-10~60
∞
1000
1200
-
Vrms
Power Systems – The Power Solution
Web:
Email:
www.Power-Systems.de
Info@Power-Systems.de
Address: Dörnet 8 ; 74360 Ilsfeld-Auenstein / Germany
Tel. :
Fax:
+ 49 / 70 62 / 67 59 - 6
+ 49 / 70 62 / 67 59 - 80
All specification are subject to change without notice.
Page ( 2 / 4 )
VER, 25 November 2003
DC-AC INVERTER UNIT
(STANDARD)
CXA-M10L-L (6W SINGLE & DUAL OUTPUTS, PCB MOUNTABLE)
APPLICATION:
Connection 1
Connection 3
Pin1 (Vin)
Pin3 (out1)
Pin4 (out2)
Pin1 (Vin)
Pin3 (out1)
Pin4 (out2)
CCFL
CCFL
Vin
Vin
Pin2 (GND) Pin5 (out GND)
Pin2 (GND) Pin5 (out GND)
Connection 2
Connection 4
Pin1 (Vin)
Pin3 (out1)
Pin4 (out2)
Pin1 (Vin)
Pin3 (out1)
Pin4 (out2)
CCFL2
CCFL
CCFL1
Vin
Vin
Pin2 (GND) Pin5 (out GND)
Pin2 (GND) Pin5 (out GND)
Note 1.
Note 2.
For circuit connection, please prefer to test circuit diagram.
Please use minimum of 2mm clearance (all directions) between inverter high voltage area and any
conductors. Please refer to mechanical drawing for marking of high voltage area.
Note 3.
Note 4.
Open voltage (strike voltage) is measured across the transformer secondary winding at no load as the
reading at the output connector would be less than the actual value.
If the start up voltage falls below Cold Cathode Tube strike voltage, the CCFL will not light up easily
specially at lower ambient temperature. Please review mounting instruction to avoid any abnormal
operation due to coupling/leakage capacitance of inverter high voltage area to any surrounding conductor.
Note 5.
Note 6.
For operation in floating mode, please remove jumper (J1) on top side of PCB that pin2 and pin5.
To prevent electrical discharge from high voltage area, please use non-conductive fastener in U mounting
hole.
Power Systems – The Power Solution
Web:
Email:
www.Power-Systems.de
Info@Power-Systems.de
Address: Dörnet 8 ; 74360 Ilsfeld-Auenstein / Germany
Tel. :
Fax:
+ 49 / 70 62 / 67 59 - 6
+ 49 / 70 62 / 67 59 - 80
All specification are subject to change without notice.
Page ( 3 / 4 )
VER, 25 November 2003
DC-AC INVERTER UNIT
(STANDARD)
CXA-M10L-L (6W SINGLE & DUAL OUTPUTS, PCB MOUNTABLE)
TEST CIRCUIT
Connection
Test circuit
Notes
lin
A
(1)Vin
OUT1 (3)
OUT2 (4)
Vin
Vin
Vin
Vin
V
V
V
V
RL
RL
RL
Short of OUT1,OUT2
1
A
(2)GND
OUT GND(5)
lout
lout
lout
1000:1
V
lin
A
(1)Vin
OUT1 (3)
OUT2 (4)
NC
A
Open of OUT2
2
3
4
(2)GND
OUT GND(5)
1000:1
V
lin
A
(1)Vin
OUT1 (3)
OUT2 (4)
Short of OUT2,OUT GND
A
(2)GND
OUT GND(5)
1000:1
V
lin
A
(1)Vin
OUT1 (3)
OUT2 (4)
RL1
lout2
A
(2)GND
OUT GND(5)
RL2
A
1000:1
V
lout1
Power Systems – The Power Solution
Web:
Email:
www.Power-Systems.de
Info@Power-Systems.de
Address: Dörnet 8 ; 74360 Ilsfeld-Auenstein / Germany
Tel. :
Fax:
+ 49 / 70 62 / 67 59 - 6
+ 49 / 70 62 / 67 59 - 80
All specification are subject to change without notice.
Page ( 4 / 4 )
VER, 25 November 2003
相关型号: