DC-AC INVERTER UNIT
CXA-P1012-NJL (9.0W DUAL OUTPUTS)
DESCRIPTION:
(PRELIMINARY INFORMATION)
This DC to AC Inverter was developed for large size LCD panel
as Multiple Media, Replacement of CRT Monitor and other
general Purpose.
APPLICABLE LCD:
9 to 15 inches Double lamp type
Lamp Voltage 600V
Lamp Current 5mA
CXA-P1012-NJL
LOT. 7X
FEATURES :
MADE IN JAPAN
High Efficiency (85%)
Fuse protection
Low noise with voltage resonant circuit
8mm Low Profile
TEMPERATURE & HUMDITY :
Operating Temperature Range
Storage Temperature Range
Humidity
-10 °C ~ +60°C
-30 °C ~ +85°C
95 %RH max
DIMENSIONS :
130.5 max
124±0.2
48±0.2
3±0.3
Unit:
mm
3-φ2.2±0.1
Weight: 21.0g typ.
CN2
CN3
1
1
1
CN1
b
4
2
1
3
b
No.
1
2
3
4
Part Discription
PCB
Connector CN1
Connector CN2
Connector CN3
Qty.
Material
UL94V-0 (FR-4 or CEM-3)
S5B-PH-SM3
Note
t=1.0mm
JST
JST
JST
1
1
1
1
SM02(8.0)B-BHS-1
SM02(8.0)B-BHS-1
Power Systems – The Power Solution
Web:
www.Power-Systems.de
Info@Power-Systems.de
Address: Dörnet 8 ; 74360 Ilsfeld-Auenstein / Germany
Email:
Tel. :
Fax:
+ 49 / 70 62 / 67 59 - 6
+ 49 / 70 62 / 67 59 - 80
All specification are subject to change without notice.
Page ( 1 / 4 )
VER, 04 October 2002
DC-AC INVERTER UNIT
CXA-P1012-NJL (9.0W DUAL OUTPUTS)
Input Side CN1:
(PRELIMINARY INFORMATION)
Output Side CN2, CN3:
Pin No.
Pin No. Symbols
Ratings
12V
0V
Symbols
Ratings
600 Vrms
-
CN 1-1
CN 1-2
CN 1-3
CN 1-4
CN 1-5
Vin
GND
CN 2-1
CN 3-1
CN 3-2
CN 3-3
V
HIGH 1, 2
CN 2-2
CN 2-3
N.C.
V
LOW 1, 2
(2V)
N.C.
-
ELECTRICAL CHARACTERISTICS:
Conditions
Specification
Items
Symbols
Unit
Vin (V) Ta (°C) RL 1, 2 (KΩ ) Min. Typ. Max.
Iout1
Iout2
Iout1
Iout2
Iin
12±0.12 18~28
120
4.5
4.0
5.0
5.0
5.5
6.0
Output Current
mArms
110~130
Input Current
Frequency
12±0.6 -10~60
-
620
37
900 mA DC
44
-
F
30
kHz
Vrms
Open Circuit Voltage Vopen 1, 2
∞
1400 1500
Power Systems – The Power Solution
Web:
www.Power-Systems.de
Info@Power-Systems.de
Address: Dörnet 8 ; 74360 Ilsfeld-Auenstein / Germany
Email:
Tel. :
Fax:
+ 49 / 70 62 / 67 59 - 6
+ 49 / 70 62 / 67 59 - 80
All specification are subject to change without notice.
Page ( 2 / 4 )
VER, 04 October 2002
DC-AC INVERTER UNIT
CXA-P1012-NJL (9.0W DUAL OUTPUTS)
APPLICATION (For Example):
Non Dimming Type
(PRELIMINARY INFORMATION)
CN1-1(Vin)
CN1-2(GND)
CN1-5(NC)
CN1-3(NC)
CN1-4(NC)
CN2-1(Vhigh1)
Iout1
Iout2
Vin
12V
CCFL1
RL1
CN2-3(Vlow1)
CN3-1(Vhigh2)
CCFL2
RL2
CN3-3(Vlow2)
Dimming by DC/DC
Converter
CN1-1(Vin)
CN1-2(GND)
CN1-5(NC)
CN1-3(NC)
CN1-4(NC)
CN2-1(Vhigh1)
Iout1
CCFL1
RL1
CN2-3(Vlow1)
CN3-1(Vhigh2)
DC/DC Converter
(Mother Board)
Iout2
CCFL2
RL2
CN3-3(Vlow2)
Dimming by PWM
CN1-1(Vin)
CN1-2(GND)
CN1-5(NC)
CN1-3(NC)
CN1-4(NC)
CN2-1(Vhigh1)
Iout1
CCFL1
RL1
CN2-3(Vlow1)
CN3-1(Vhigh2)
Duty Dimmig
(Mother Board)
Iout2
CCFL2
RL2
CN3-3(Vlow2)
TEST CIRCUIT:
O s c illo s c o p e
F
V
~
Iin
C N 2 -1
A
C N 1 -1
-
R L 1
V in
1 0 0 0 :1
1 2 V
V
C N 2 -3
C N 1 -2
C N 1 -3
C N 1 -4
C N 1 -5
V o p e n 1
-
A
~
Io u t1
N C
N C
V
~
C N 3 -1
C N 3 -3
N C
R L 2
1 0 0 0 :1
V o p e n 2
A
~
Io u t2
Power Systems – The Power Solution
Web:
www.Power-Systems.de
Info@Power-Systems.de
Address: Dörnet 8 ; 74360 Ilsfeld-Auenstein / Germany
Email:
Tel. :
Fax:
+ 49 / 70 62 / 67 59 - 6
+ 49 / 70 62 / 67 59 - 80
All specification are subject to change without notice.
Page ( 3 / 4 )
VER, 04 October 2002
DC-AC INVERTER UNIT
CXA-P1012-NJL (9.0W DUAL OUTPUTS)
(PRELIMINARY INFORMATION)
Note 1.
Note 2.
For circuit connection, please prefer to test circuit diagram.
Please use minimum of 2mm clearance (all directions) between inverter high voltage area and any
conductors. Please refer to mechanical drawing for marking of high voltage area.
Note 3.
Note 4.
Note 5.
Open voltage (strike voltage) is measured across the transformer secondary winding at no load as the
reading at the output connector would be less than the actual value.
The output of this dc-ac inverter is insulated in electricity with the input part.
Please use CN2-3 and CN3-3 side when you connect the Vlow side of the output with the ground.
Please use the screw of the insulator to prevent the electrical discharge or make the installation. Screw the
first side and an insulated structure in electricity because the output pattern of a high voltage is laid out to
be near when you use the installation hold of part b in the externals dimensional drawing.
Note 6.
If the start up voltage falls below Cold Cathode Tube strike voltage, the CCFL will not light up easily
specially at lower ambient temperature. Please review mounting instruction to avoid any abnormal
operation due to coupling/leakage capacitance of inverter high voltage area to any surrounding conductor.
Power Systems – The Power Solution
Web:
www.Power-Systems.de
Info@Power-Systems.de
Address: Dörnet 8 ; 74360 Ilsfeld-Auenstein / Germany
Email:
Tel. :
Fax:
+ 49 / 70 62 / 67 59 - 6
+ 49 / 70 62 / 67 59 - 80
All specification are subject to change without notice.
Page ( 4 / 4 )
VER, 04 October 2002
相关型号:
©2020 ICPDF网 联系我们和版权申明