LM96000 [NSC]
Hardware Monitor with Integrated Fan Control; 硬件监控,集成风扇控制型号: | LM96000 |
厂家: | National Semiconductor |
描述: | Hardware Monitor with Integrated Fan Control |
文件: | 总28页 (文件大小:691K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
November 2004
LM96000
Hardware Monitor with Integrated Fan Control
n Noise filtering of temperature reading for fan control
n 1.0˚C digital temperature sensor resolution
General Description
The LM96000, hardware monitor, has a two wire digital
interface compatible with SMBus 2.0. Using an 8-bit Σ∆
ADC, the LM96000 measures:
n 3 PWM fan speed control outputs
n Provides high and low PWM frequency ranges
n 4 fan tachometer inputs
n Monitors 5 VID control lines
n 24-pin TSSOP package
– the temperature of two remote diode connected transis-
tors as well as its own die
– the VCCP, 2.5V, 3.3VSBY, 5.0V, and 12V supplies (in-
ternal scaling resistors).
n XOR-tree test mode
To set fan speed, the LM96000 has three PWM outputs that
are each controlled by one of three temperature zones. High
and low PWM frequency ranges are supported. The
LM96000 includes a digital filter that can be invoked to
smooth temperature readings for better control of fan speed.
The LM96000 has four tachometer inputs to measure fan
speed. Limit and status registers for all measured values are
included.
Key Specifications
n Voltage Measurement Accuracy
n Resolution
2% FS (max)
8-bits, 1˚C
3˚C (max)
n Temperature Sensor Accuracy
n Temperature Range
— LM96000 Operational
— Remote Temp Accuracy
n Power Supply Voltage
n Power Supply Current
0˚C to +85˚C
0˚C to +125˚C
+3.0V to +3.6V
0.53 mA
Features
n 2-wire, SMBus 2.0 compliant, serial digital interface
n 8-bit Σ∆ ADC
Applications
n Monitors VCCP, 2.5V, 3.3 VSBY, 5.0V, and 12V
motherboard/processor supplies
n Monitors 2 remote thermal diodes
n Programmable autonomous fan control based on
temperature readings
n Desktop PC
n Microprocessor based equipment
(e.g. Base-stations, Routers, ATMs, Point of Sales)
Block Diagram
20084601
© 2004 National Semiconductor Corporation
DS200846
www.national.com
Connection Diagram
24 Pin TSSOP
20084602
NS Package MTC24E
Top View
LM96000CIMT (61 units per rail), or
LM96000CIMTX (2500 units per tape and reel)
Pin Descriptions
Symbol
Pin
Type
Name and Function/Connection
SMBDAT
1
Digital I/O
System Management Bus Data. Open-drain output. 5V tolerant,
SMBus 2.0 compliant.
(Open-Drain)
Digital Input
SMBCLK
VID0
2
System Management Bus Clock. Tied to Open-drain output. 5V
tolerant, SMBus 2.0 compliant.
5
Digital Input
Digital Input
Digital Input
Digital Input
Digital Input
POWER
Voltage identification signal from the processor. This value is read
in the VID0–VID4 Status Register.
VID1
6
Voltage identification signal from the processor. This value is read
in the VID0–VID4 Status Register.
VID2
7
Voltage identification signal from the processor. This value is read
in the VID0–VID4 Status Register.
VID3
8
Voltage identification signal from the processor. This value is read
in the VID0–VID4 Status Register.
VID4
19
4
Voltage identification signal from the processor. This value is read
in the VID0–VID4 Status Register.
3.3V
+3.3V pin. Can be powered by +3.3V Standby power if monitoring
in low power states is required. This pin also serves as the analog
input to monitor the 3.3V supply. This pin should be bypassed
with a 0.1µf capacitor in parallel with 100pf. A bulk capacitance of
approximately 10µf needs to be in the near vicinity of the
LM96000.
GND
5V
3
GROUND
Ground for all analog and digital circuitry.
20
Analog Input
Analog input for +5V monitoring.
12V
2.5V
21
22
23
Analog Input
Analog Input
Analog Input
Analog input for +12V monitoring.
Analog input for +2.5V monitoring.
VCCP_IN
Analog input for VCCP (processor voltage) monitoring.
www.national.com
2
Pin Descriptions (Continued)
Symbol
Pin
Type
Name and Function/Connection
Remote1+
18
Remote Thermal Positive input (current source) from the first remote thermal diode.
Diode Positive Serves as the positive input into the A/D. Connected to
Input
THERMDA pin of Pentium processor or the base of a diode
connected MMBT3904 NPN transistor.
Remote1−
Remote2+
Remote2−
17
16
15
Remote Thermal Negative input (current sink) from the first remote thermal diode.
Diode Negative Serves as the negative input into the A/D. Connected to
Input
THERMDC pin of Pentium processor or the emmiter of a diode
connected MMBT3904 NPN transistor.
Remote Thermal Positive input (current source) from the first remote thermal diode.
Diode Positive Serves as the positive input into the A/D. Connected to
Output
THERMDA pin of Pentium processor or the base of a diode
connected MMBT3904 NPN transistor.
Remote Thermal Negative input (current sink) from the first remote thermal diode.
Diode Negative Serves as the negative input into the A/D. Connected to
Input
THERMDC pin of Pentium processor or the emmiter of a diode
connected MMBT3904 NPN transistor.
TACH1
TACH2
TACH3
11
12
9
Digital Input
Digital Input
Digital Input
Digital Input
Input for monitoring tachometer output of fan 1.
Input for monitoring tachometer output of fan 2.
Input for monitoring tachometer output of fan 3.
TACH4/Address
Select
14
Input for monitoring tachometer output of fan 4. If in Address
Select Mode, determines the SMBus address of the LM96000.
PWM1/xTest
Out
24
10
13
Digital Open-Drain Fan speed control 1. When in XOR tree test mode, functions as
Output XOR Tree output.
PWM2
Digital Open-Drain Fan speed control 2.
Output
PWM3/Address
Enable
Digital Open-Drain Fan speed control 3. Pull to ground at power on to enable
Output
Address Select Mode (Address Select pin controls SMBus
address of the device).
3
www.national.com
Absolute Maximum Ratings (Notes 1, 2)
If Military/Aerospace specified devices are required,
please contact the National Semiconductor Sales Office/
Distributors for availability and specifications.
Storage Temperature
−65˚C to +150˚C
Soldering process must comply with National’s reflow
temperature profile specifications. Refer to
www.national.com/packaging/. (Note 6)
Supply Voltage, V+
−0.5V to 6.0V
−0.5V to 6.0V
Voltage on Any Digital Input or
Output Pin
Operating Ratings (Notes 1, 2)
LM96000 Operating Temperature
Range
0˚C ≤ TA ≤ +85˚C
Voltage on 12V Analog Input
Voltage on 5V Analog Input
−0.5V to 16V
−0.5V to 6.66V
Remote Diode Temperature Range
Supply Voltage (3.3V nominal)
VIN Voltage Range
+12V VIN
0˚C ≤ TD ≤ +125˚C
Voltage on Remote1+, Remote2+, −0.5V to (V+ + 0.05V)
+3.0V to +3.6V
Current on Remote1−, Remote2−
Voltage on Other Analog Inputs
Input Current on Any Pin (Note 3)
Package Input Current (Note 3)
Package Dissipation at TA = 25˚C
ESD Susceptibility (Note 4)
Human Body Model
1 mA
−0.5V to 6.0V
5 mA
−0.05V to 16V
−0.05V to 6.66V
3.0V to 4.4V
+5V VIN
20 mA
+3.3V VIN
See (Note 5)
VCCP_IN and All Other Inputs −0.05V to (V+ + 0.05V)
VID0–VID4
−0.05V to 5.5V
0.53 mA
2500V
250V
Typical Supply Current
Machine Model
DC Electrical Characteristics
The following specifications apply for V+ = 3.0V to 3.6V, and all analog input source impedance RS = 50Ω unless otherwise
specified in conditions. Boldface limits apply for TA = TJ over TMIN =0˚C to TMAX=85˚C; all other limits TA =TJ= 25˚C. TA is
the ambient temperature of the LM96000; TJ is the junction temperature of the LM96000; TD is the thermal diode junction tem-
perature.
Symbol
Parameter
Conditions
Typical
Limits
Units
(Note 7)
(Note 8)
(Limits)
POWER SUPPLY CHARACTERISTICS
Supply Current (Note 9)
Converting, Interface and
Fans Inactive, Peak
Current
1.8
3.5
mA (max)
mA
Converting, Interface and
Fans Inactive, Average
Current
0.53
Power-On Reset Threshold Voltage
1.6
2.8
V (min)
V (max)
TEMPERATURE TO DIGITAL CONVERTER CHARACTERISTICS
Resolution
1
8
˚C
Bits
Temperature Accuracy (See (Note 10) for Thermal TD=25˚C
2.5
3
˚C (max)
˚C (max)
˚C (max)
˚C (max)
Diode Processor Type)
TD=0˚C to 100˚C
1
1
TD=100˚C to 125˚C
4
Temperature Accuracy using Internal Diode (Note
3
11)
IDS
External Diode Current Source
High Level
Low Level
188
11.75
16
280
µA (max)
µA
External Diode Current Ratio
ANALOG TO DIGITAL CONVERTER CHARACTERISTICS
TUE
DNL
Total Unadjusted Error(Note 12)
Differential Non-linearity
2
%FS (max)
LSB
1
1
Power Supply Sensitivity
%/V
Total Monitoring Cycle Time (Note 13)
All Voltage and
182
200
ms (max)
Temperature readings
www.national.com
4
DC Electrical Characteristics (Continued)
The following specifications apply for V+ = 3.0V to 3.6V, and all analog input source impedance RS = 50Ω unless otherwise
specified in conditions. Boldface limits apply for TA = TJ over TMIN =0˚C to TMAX=85˚C; all other limits TA =TJ= 25˚C. TA is
the ambient temperature of the LM96000; TJ is the junction temperature of the LM96000; TD is the thermal diode junction tem-
perature.
Symbol
Parameter
Conditions
Typical
(Note 7)
210
Limits
(Note 8)
140
Units
(Limits)
kΩ (min)
kΩ (max)
Input Resistance, all analog inputs
400
DIGITAL OUTPUT: PWM1, PWM2, PWM3, XTESTOUT
IOL
Logic Low Sink Current
Logic Low Level
VOL=0.4V
8
mA (min)
V (max)
VOL
IOUT = +8 mA
0.4
SMBUS OPEN-DRAIN OUTPUT: SMBDAT
VOL
IOH
Logic Low Output Voltage
High Level Output Current
IOUT = +4 mA
VOUT = V+
0.4V
10
V (max)
0.1
µA (max)
SMBUS INPUTS: SMBCLK. SMBDAT
VIH
Logic Input High Voltage
Logic Input Low Voltage
Logic Input Hysteresis Voltage
2.1
0.8
V (min)
V (max)
mV
VIL
VHYST
300
DIGITAL INPUTS: ALL
VIH
VIL
VTH
IIH
Logic Input High Voltage
2.1
0.8
V (min)
V (max)
V
Logic Input Low Voltage
Logic Input Threshold Voltage
Logic High Input Current
Logic Low Input Current
Digital Input Capacitance
1.5
0.005
−0.005
20
VIN = V+
10
µA (max)
µA (max)
pF
IIL
VIN = GND
−10
CIN
AC Electrical Characteristics
The following specifications apply for V+ = 3.0V to 3.6V unless otherwise specified in conditions. Boldface limits apply for TA
= TJ over TMIN =0˚C to TMAX=85˚C; all other limits TA =TJ= 25˚C.
Symbol
Parameter
Conditions
Typical
Limits
Units
(Note 7)
(Note 8)
(Limits)
TACHOMETER ACCURACY
Fan Count Accuracy
10
% (max)
(max)
Fan Full-Scale Count
65536
Fan Counter Clock Frequency
Fan Count Conversion Time
90
kHz
0.7
1.4
10
sec (max)
FAN PWM OUTPUT
Frequency Setting Accuracy
Frequency Range
% (max)
Hz
10
30
kHz
Duty-Cycle Range
Low frequency range
0 to 100 % (max)
Duty-Cycle Resolution (8-bits)
Spin-Up Time Interval Range
0.390625
100
%
ms ms
4000
Spin-Up Time Interval Accuracy
10
10
% (max)
SPIKE SMOOTHING FILTER
Time Interval Deviation
Time Interval Range
% (max)
sec
35
0.8
sec
SMBUS TIMING CHARACTERISTICS
fSMB
SMBus Operating Frequency
10
100
kHz (min)
kHz (max)
5
www.national.com
AC Electrical Characteristics (Continued)
The following specifications apply for V+ = 3.0V to 3.6V unless otherwise specified in conditions. Boldface limits apply for TA
= TJ over TMIN =0˚C to TMAX=85˚C; all other limits TA =TJ= 25˚C.
Symbol
Parameter
Conditions
Typical
(Note 7)
Limits
(Note 8)
4.7
Units
(Limits)
µs (min)
fBUF
SMBus Free Time Between Stop And
Start Condition
tHD_STA
Hold Time After (Repeated) Start
Condition (after this period, the first
clock is generated)
4.0
µs (min)
tSU:STA
tSU:STO
tHD:DAT
Repeated Start Condition Setup Time
Stop Condition Setup Time
Data Output Hold Time
4.7
4.0
300
930
250
25
µs (min)
µs (min)
ns (min)
ns (max)
ns (min)
ms (min)
ms (max)
µs (min)
µs (min)
µs (max)
ns (max)
ns (max)
ms (max)
tSU:DAT
Data Input Setup Time
tTIMEOUT
Data And Clock Low Time To Reset
Of SMBus Interface Logic(Note 14)
Clock Low Period
35
tLOW
tHIGH
4.7
4.0
50
Clock High Period
tF
Clock/Data Fall Time
300
1000
500
tR
Clock/Data Rise Time
>
V+ 2.8V
tPOR
Time from Power-On-Reset to
LM96000 Reset and Operational
20084603
Note 1: Absolute Maximum Ratings indicate limits beyond which damage to the device may occur. Operating Ratings indicate conditions for which the device is
functional, but do not guarantee specific performance limits. For guaranteed specifications and test conditions, see the Electrical Characteristics. The guaranteed
specifications apply only for the test conditions listed. Some performance characteristics may degrade when the device is not operated under the listed test
conditions.
Note 2: All voltages are measured with respect to GND, unless otherwise noted.
<
>
V+ ), the current at that pin should be limited to 5mA. The 20mA
Note 3: When the input voltage (V ) at any pin exceeds the power supplies (V
GND or V
IN
IN
IN
maximum package input current rating limits the number of pins that can safely exceed the power supplies with an input current of 5mA to four. Parasitic components
and/or ESD protection circuitry are shown below for the LM96000’s pins. The nominal breakdown voltage the zener is 6.5V. Care should be taken not to forward bias
the parasitic diode D1 present on pins D+ and D−. Doing so by more that 50 mV may corrupt temperature measurements. SNP stands for snap-back device.
www.national.com
6
Pin
#
Pin
Name
Circuit
All Input Circuits
1
SMBDAT
A
2
3
SMBCLK
GND
B
A
4
3.3V
Circuit A
5
VID0
6
VID1
7
VID2
8
VID3
9
TACH3
Circuit B
Circuit C
Circuit D
10
11
12
13
14
15
16
17
18
19
20
PWM2
TACH1
TACH2
PWM3/AddEnable
TACH4/AddSel
REMOTE2−
REMOTE2+
REMOTE1−
REMOTE1+
VID4
C
D
C
D
A
E
5V
21
22
23
24
12V
2.5V
VCCP_IN
PWM1/xTEXTOUT
A
Circuit E
Note 4: Human body model, 100pF discharged through a 1.5kΩ resistor. Machine model, 200pF discharged directly into each pin.
Note 5: Thermal resistance junction-to-ambient when attached to a double-sided printed circuit board with 1 oz. foil is 113 ˚C/W.
Note 6: Reflow temperature profiles are different for packages containing lead (Pb) than for those that do not.
Note 7: Typicals are at T = 25˚C and represent most likely parametric norm.
A
Note 8: Limits are guaranteed to National’s AOQL (Average Outgoing Quality Level).
Note 9: The average current can be calculated from the peak current using the following equation:
Quiescent current will not increase substantially with an SMBus transaction.
Note 10: The accuracy of the LM96000CIMT is guaranteed when using the thermal diode of Intel Pentium 4 90nm processors or any thermal diode with a
non-ideality of 1.011 and series resistance of 3.33Ω. When using a 2N3904 type transistor as a thermal diode the error band will be typically shifted by -?˚C.
Note 11: Local temperature accuracy does not include the effects of self-heating. The rise in temperature due to self-heating is the product of the internal power
dissipation of the LM96000 and the thermal resistance. See (Note 5) for the thermal resistance to be used in the self-heating calculation.
Note 12: TUE , total unadjusted error, includes ADC gain, offset, linearity and reference errors. TUE is defined as the "actual Vin" to achieve a given code transition
minus the "theoretical Vin" for the same code. Therefore, a positive error indicates that the input voltage is greater than the theoretical input voltage for a given code.
If the theoretical input voltage was applied to an LM96000 that has positive error, the LM96000’s reading would be less than the theoretical.
Note 13: This specification is provided only to indicate how often temperature and voltage data is updated. The LM96000 can be read at any time without regard
to conversion state (and will yield last conversion result).
7
www.national.com
Note 14: Holding the SMBDAT and/or SMBCLK lines Low for a time interval greater than t
will reset the LM96000’s SMBus state machine, therefore setting
TIMEOUT
the SMBDAT pin to a high impedance state.
Functional Description
1.0 SMBUS
The LM96000 is compatible with devices that are compliant to the SMBus 2.0 specification. More information on this bus can be
found at: http://www.smbus.org/. Compatibility of SMBus2.0 to other buses is discussed in the SMBus 2.0 specification.
1.1 Addressing
LM96000 is designed to be used primarily in desktop systems that require only one monitoring device.
If only one LM96000 is used on the motherboard, the designer should be sure that the Address Enable/PWM3 pin is High during
the first SMBus communication addressing the LM96000. Address Enable/PWM3 is an open drain I/O pin that at power-on
defaults to the input state of Address Enable. A maximum of 10k pull-up resistance on Address Enable/PWM3 is required to
assure that the SMBus address of the device will be locked at 010 1110b, which is the default address of the LM96000.
During the first SMBus communication TACH4 and PWM3 can be used to change the SMBus address of the LM96000 to
0101101b or 0101100b. LM96000 address selection procedure:
A 10 kΩ pull-down resistor to ground on the Address Enable/PWM3 pin is required. Upon power up, the LM96000 will be placed
into Address Enable mode and assign itself an SMBus address according to the state of the Address Select input. The
LM96000 will latch the address during the first valid SMBus transaction in which the first five bits of the targeted address match
those of the LM96000 address, 0 1011b. This feature eliminates the possibility of a glitch on the SMBus interfering with address
selection. When the PWM3/Address Enable pin is not used to change the SMBus address of the LM96000, it will remain in a
high state until the first communication with the LM96000. After the first SMBus transaction is completed PWM3 and TACH4 will
return to normal operation.
Address Enable
Address Select
Board Implementation
SMBus Address
010 1100b, 2Ch
010 1101b, 2Dh
010 1110b, 2Eh
0
0
1
0
1
X
Pulled to ground through a 10 kΩ resistor
Pulled to 3.3V or to GND through a 10 kΩ resistor
Pulled to 3.3V through a 10 kΩ resistor
In this way, up to three LM96000 devices can exists on an SMBus at any time. Multiple LM96000 devices can be used to monitor
additional processors and temperature zones. When using the non-default addresses additional circuitry will be required if TACH4
and PWM3 require to function correctly. Such circuitry could consist of GPIO pins from a micro-controller. During the first
communication the micro-controller would drive the Address Enable and Address Select pins to the proper state for the required
address. After the first SMBus communication the micro-controller would drive it’s pins into TRISTATE allowing TACH4 and
PWM3 to operate correctly.
20084604
2.0 FAN REGISTER DEVICE SET-UP
The BIOS will follow the following steps to configure the fan registers on the LM96000. The registers corresponding to each
function are listed. All steps may not be necessary if default values are acceptable. Regardless of all changes made by the BIOS
to the fan limit and parameter registers during configuration, the LM96000 will continue to operate based on default values until
the START bit (bit 0), in the Ready/Lock/Start/Override register (address 40h), is set. Once the fan mode is updated, by setting
the START bit to 1, the LM96000 will operate using the values that were set by the BIOS in the fan control limit and parameter
registers (adress 5Ch through 6Eh).
www.national.com
8
Functional Description (Continued)
1. Set limits and parameters (not necessarily in this order):
– [5F-61h] Set PWM frequencies and auto fan control range.
– [62-63h] Set spike smoothing and min/off.
– [5C-5Eh] Set the fan spin-up delays.
– [5C-5Eh] Match each fan with a corresponding thermal zone.
– [67-69h] Set the fan temperature limits.
– [6A-6Ch] Set the temperature absolute limits.
– [64-66h] Set the PWM minimum duty cycle.
– [6D-6Eh] Set the temperature Hysteresis values.
2. [40h] Set bit 0 (START) to update fan control and limit register values and start fan control based on these new values.
3. [40h] Set bit 1 (LOCK) to lock the fan limit and parameter registers (optional).
3.0 AUTO FAN CONTROL OPERATING MODE
The LM96000 includes the circuitry for automatic fan control. In Auto Fan Mode, the LM96000 will automatically adjust the PWM
duty cycle of the PWM outputs. PWM outputs are assigned to a thermal zone based on the fan configuration registers. It is
possible to have more than one PWM output assigned to a thermal zone. For example, PWM outputs 2 and 3, connected to two
chassis fans, may both be controlled by thermal zone 2. At any time, the temperature of a zone exceeds its absolute limit, all PWM
outputs will go to 100% duty cycle to provide maximum cooling to the system.
4.0 REGISTER SET
Register Read/ Register
Address Write Name
Bit 7 Bit 6 Bit 5 Bit 4 Bit 3
(MSB)
Bit 2
Bit 1
Bit 0 Default Lock?
(LSB)
Value
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
01h
68h
00h
00h
00h
N/A
00h
FFh
00h
FFh
00h
20h
21h
22h
23h
24h
25h
26h
27h
28h
29h
2Ah
2Bh
2Ch
2Dh
2Eh
2Fh
30h
31h
32h
3Eh
3Fh
40h
41h
42h
43h
44h
45h
46h
47h
48h
R
2.5V
7
7
6
6
5
5
4
4
3
3
2
2
1
1
1
1
1
1
1
1
0
0
0
0
0
0
0
0
R
VCCP_IN
R
3.3V
7
6
5
4
3
2
R
5V
7
6
5
4
3
2
R
12V
7
6
5
4
3
2
R
Processor (Zone1) Temp
Internal (Zone2) Temp
Remote (Zone3) Temp
Tach1 LSB
7
6
5
4
3
2
R
7
6
5
4
3
2
R
7
6
5
4
3
2
R
7
6
5
4
3
2
LEVEL1 LEVEL0
R
Tach1 MSB
15
7
14
6
13
5
12
4
11
3
10
2
9
8
R
Tach2 LSB
LEVEL1 LEVEL0
R
Tach2 MSB
15
7
14
6
13
5
12
4
11
3
10
2
9
8
R
Tach3 LSB
LEVEL1 LEVEL0
R
Tach3 MSB
15
7
14
6
13
5
12
4
11
3
10
2
9
8
R
Tach4 LSB
LEVEL1 LEVEL0
R
Tach4 MSB
15
7
14
6
13
5
12
4
11
3
10
2
9
8
R/W
R/W
R/W
R
Fan1 Current PWM Duty
Fan2 Current PWM Duty
Fan3 Current PWM Duty
Company ID
Version/Stepping
1
0
7
6
5
4
3
2
1
1
0
0
7
6
5
4
3
2
7
6
5
4
3
2
1
0
R
VER3 VER2 VER1 VER0 STP3
STP2
STP1
STP0
R/W
R
Ready/Lock/Start/Override RES RES RES RES OVRID READY LOCK START
Interrupt Status Register 1 ERR
ZN3 ZN2 ZN1
5V
3.3V
VCCP
2.5V
R
Interrupt Status Register 2 ERR2 ERR1 FAN4 FAN3 FAN2
FAN1
RES
12V
R
VID0–4
RES RES RES VID4 VID3
VID2
VID1
VID0
R/W
R/W
R/W
R/W
R/W
2.5V Low Limit
2.5V High Limit
VCCP Low Limit
VCCP High Limit
3.3V Low Limit
7
7
7
7
7
6
6
6
6
6
5
5
5
5
5
4
4
4
4
4
3
3
3
3
3
2
2
2
2
2
1
1
1
1
1
0
0
0
0
0
9
www.national.com
Functional Description (Continued)
Register Read/ Register
Address Write Name
Bit 7 Bit 6 Bit 5 Bit 4 Bit 3
(MSB)
Bit 2
Bit 1
Bit 0 Default Lock?
(LSB)
Value
FFh
00h
49h
4Ah
4Bh
4Ch
4Dh
4Eh
R/W
R/W
R/W
R/W
R/W
R/W
3.3V High Limit
7
7
7
7
7
7
6
6
6
6
6
6
5
5
5
5
5
5
4
4
4
4
4
4
3
3
3
3
3
3
2
2
2
2
2
2
1
1
1
1
1
1
0
0
0
0
0
0
5V Low Limit
5V High Limit
FFh
00h
12V Low Limit
12V High Limit
FFh
81h
Processor (Zone1) Low
Temp
4Fh
50h
51h
52h
53h
R/W
R/W
R/W
R/W
R/W
Processor (Zone1) High
Temp
7
7
7
7
7
6
6
6
6
6
5
5
5
5
5
4
4
4
4
4
3
3
3
3
3
2
2
2
2
2
1
1
1
1
1
0
0
0
0
0
7Fh
81h
7Fh
81h
7Fh
Internal (Zone2) Low
Temp
Internal (Zone2) High
Temp
Remote (Zone3) Low
Temp
Remote (Zone3) High
Temp
54h
55h
56h
57h
58h
59h
5Ah
5Bh
5Ch
5Dh
5Eh
5Fh
60h
61h
62h
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
Tach1 Minimum LSB
Tach1 Minimum MSB
Tach2 Minimum LSB
Tach2 Minimum MSB
Tach3 Minimum LSB
Tach3 Minimum MSB
Tach4 Minimum LSB
Tach4 Minimum MSB
Fan1 Configuration
Fan2 Configuration
Fan3 Configuration
Fan1 Range/Frequency
Fan2 Range/Frequency
Fan3 Range/Frequency
Min/Off, Zone1 Spike
Smoothing
7
15
7
6
14
6
5
13
5
4
12
4
3
11
2
10
2
1
9
1
9
1
9
1
9
0
8
FFh
FFh
FFh
FFh
FFh
FFh
FFh
FFh
62h
62h
62h
C4h
C4h
C4h
00H
3
0
15
7
14
6
13
5
12
4
11
10
2
8
3
0
15
7
14
6
13
5
12
4
11
10
2
8
3
0
15
14
13
12
11
10
8
ZON2 ZON1 ZON0 INV
ZON2 ZON1 ZON0 INV
ZON2 ZON1 ZON0 INV
RES
RES
RES
SPIN2 SPIN1
SPIN2 SPIN1
SPIN2 SPIN1
SPIN0
SPIN0
SPIN0
FRQ0
FRQ0
FRQ0
ZN1-0
U
U
U
U
U
U
U
RAN3 RAN2 RAN1 RAN0 HLFRQ FRQ2
RAN3 RAN2 RAN1 RAN0 HLFRQ FRQ2
RAN3 RAN2 RAN1 RAN0 HLFRQ FRQ2
OFF3 OFF2 OFF1 RES ZN1E ZN1-2
FRQ1
FRQ1
FRQ1
ZN1-1
63h
R/W
Zone2, Zone3 Spike
Smoothing
ZN2E ZN2-2 ZN2-1 ZN2-0 ZN3E ZN3-2
ZN3-1
ZN3-0
00h
U
64h
65h
66h
67h
68h
69h
6Ah
R/W
R/W
R/W
R/W
R/W
R/W
R/W
Fan1 PWM Minimum
Fan2 PWM Minimum
Fan3 PWM Minimum
Zone1 Fan Temp Limit
Zone2 Fan Temp Limit
Zone3 Fan Temp Limit
Zone1 Temp Absolute
Limit
7
7
7
7
7
7
7
6
6
6
6
6
6
6
5
5
5
5
5
5
5
4
4
4
4
4
4
4
3
3
3
3
3
3
3
2
2
2
2
2
2
2
1
1
1
1
1
1
1
0
0
0
0
0
0
0
80h
80h
80h
5Ah
5Ah
5Ah
64h
U
U
U
U
U
U
U
6Bh
6Ch
R/W
R/W
Zone2 Temp Absolute
Limit
7
7
6
6
5
5
4
4
3
3
2
2
1
1
0
0
64h
64h
U
U
Zone3 Temp Absolute
Limit
6Dh
6Eh
R/W
R/W
Zone1, Zone2 Hysteresis
Zone3 Hysteresis
H1-3 H1-2 H1-1 H1-0 H2-3
H3-3 H3-2 H3-1 H3-0 RES
H2-2
RES
H2-1
RES
H2-0
RES
44h
40h
U
U
www.national.com
10
Functional Description (Continued)
Register Read/ Register
Address Write Name
Bit 7 Bit 6 Bit 5 Bit 4 Bit 3
(MSB)
Bit 2
Bit 1
Bit 0 Default Lock?
(LSB)
XEN
T1-0
Value
00h
00h
7h
6Fh
74h
75h
R/W
R/W
R/W
XOR Test Tree Enable
Tach Monitor Mode
Fan Spin-up Mode
RES RES RES RES
RES
RES
T2-0
RES
T1-1
U
U
RES RES T3/4-1 T3/4-0 T2-1
RES RES RES RES RES
PWM3 PWM2 PWM1
SU SU SU
Note: Reserved bits will always return 0 when read.
4.1 Register 20-24h: Voltage Reading
Register
Address
20h
Read/
Write
R
Register
Name
2.5V
Bit 7
(MSB)
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
(LSB)
Default
Value
N/A
7
7
7
7
7
6
6
6
6
6
5
5
5
5
5
4
4
4
4
4
3
3
3
3
3
2
2
2
2
2
1
1
1
1
1
0
0
0
0
0
21h
R
VCCP
3.3V
N/A
22h
R
N/A
23h
R
5V
N/A
24h
R
12V
N/A
3
The Register Names difine the typical input voltage at which the reading is
⁄4 full scale or C0h.
The Voltage Reading registers are updated automatically by the LM96000 at a minimum frequency of 4 Hz. These registers are
read only — a write to these registers has no effect.
4.2 Register 25-27h: Temperature Reading
Register
Address
25h
Read/
Write
R
Register
Name
Bit 7
(MSB)
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
(LSB)
Default
Value
N/A
Processor (Zone1) Temp
Internal (Zone2) Temp
Remote (Zone3) Temp
7
7
7
6
6
6
5
5
5
4
4
4
3
3
3
2
2
2
1
1
1
0
0
0
26h
R
N/A
27h
R
N/A
The Temperature Reading registers reflect the current temperatures of the internal and remote diodes. Processor (Zone1) Temp
register reports the temperature measured by the thermal diode connected to the Remote1− and Remote1+ pins, Remote
(Zone3) Temp register reports the temperature measured by the thermal diode connected to the the Remote2− and Remote2+
pins, and the Internal (Zone2) Temp register reports the temperature measured by the internal (junction) temperature sensor.
Temperatures are represented as 8 bit, 2’s complement, signed numbers, in Celsius, as shown below in Table 1. The Temperature
Reading register will return a value of 80h if the remote diode pins are not used by the board designer or are not functioning
properly. This reading will cause the zone limit bit(s) (bits 6 and 4) in the Interrupt Status Register (41h) and the remote diode fault
status bit(s) (bit 6 or 7) in the Interrupt Status Register 2 (42h) to be set. The Temperature Reading registers are updated
automatically by the LM96000 at a minimum frequency of 4 Hz. These registers are read only — a write to these registers has
no effect.
TABLE 1. Temperature vs Register Reading
Temperature
Reading (Dec)
Reading (Hex)
−127˚C
−127
81h
.
.
.
.
.
.
.
.
.
−50˚C
−50
CEh
11
www.national.com
Functional Description (Continued)
TABLE 1. Temperature vs Register Reading (Continued)
Temperature
Reading (Dec)
Reading (Hex)
.
.
.
.
.
.
.
.
.
0˚C
0
00h
.
.
.
.
.
.
.
.
.
127˚C
127
7Fh
80h
(SENSOR ERROR)
4.3 Register 28-2Fh: Fan Tachometer Reading
Register
Address
28h
Read/
Write
R
Register
Name
Bit 7
(MSB)
7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
(LSB)
LEVEL0
8
Default
Value
N/A
Tach1 LSB
Tach1 MSB
Tach2 LSB
Tach2 MSB
Tach3 LSB
Tach3 MSB
Tach4 LSB
Tach4 MSB
6
5
4
3
2
LEVEL1
29h
R
15
7
14
6
13
5
12
4
11
3
10
2
9
N/A
2Ah
R
LEVEL1
LEVEL0
8
N/A
2Bh
R
15
7
14
6
13
5
12
4
11
3
10
2
9
N/A
2Ch
R
LEVEL1
LEVEL0
8
N/A
2Dh
R
15
7
14
6
13
5
12
4
11
3
10
2
9
N/A
2Eh
R
LEVEL1
9
LEVEL0
8
N/A
2Fh
R
15
14
13
12
11
10
N/A
The Fan Tachometer Reading registers contain the number of 11.111 µs periods (90 kHz) between full fan revolutions. The results
are based on the time interval of two tachometer pulses, since most fans produce two tachometer pulses per full revolution. These
registers will be updated at least once every second.
The value, for each fan, is represented by a 16-bit unsigned number.
The Fan Tachometer Reading registers will always return an accurate fan tachometer measurement, even when a fan is disabled
or non-functional.
The least two significant bits (LEVEL1 and LEVEL2) of the least significant byte are used to indicate the accuracy level of the
tachometer reading. The accuracy ranges from most to least accurate. [LEVEL1:LEVEL2]=11indicates a most accurate value,
[LEVEL1:LEVEL2]=01 indicates the least accurate value and [LEVEL1:LEVEL2]=00 is reserved for future use.
FF FFh indicates that the fan is not spinning, or that the tachometer input is not connected to a valid signal. These registers are
read only — a write to these registers has no effect.
When the LSByte of the LM96000 16-bit register is read, the other byte (MSByte) is latched at the current value until it is read.
At the end of the MSByte read the Fan Tachometer Reading registers are updated.
During spin-up, the PWM duty cycle reported is 0%.
4.4 Register 30-32h: Current PWM Duty
Register
Address
30h
Read/
Write
R/W
Register
Name
Bit 7
(MSB)
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
(LSB)
Default
Value
N/A
Fan1 Current PWM Duty
Fan2 Current PWM Duty
Fan3 Current PWM Duty
7
7
7
6
6
6
5
5
5
4
4
4
3
3
3
2
2
2
1
1
1
0
0
0
31h
R/W
N/A
32h
R/W
N/A
The Current PWM Duty registers store the current duty cycle at each PWM output. At initial power-on, the PWM duty cycle is
100% and thus, when read, this register will return FFh. After the Ready/Lock/Start/Override register Start bit is set, this register
and the PWM signals will be updated based on the algorithm described in the Auto Fan Control Operating Mode section.
When read, the Current PWM Duty registers return the current PWM duty cycle. These registers are read only unless the fan is
in manual (test) mode, in which case a write to these registers will directly control the PWM duty cycle for each fan. The PWM
duty cycle is represented as shown in the following table.
Current Duty
Value (Decimal)
Value (Hex)
0%
0
00h
www.national.com
12
Functional Description (Continued)
Current Duty
Value (Decimal)
Value (Hex)
0.3922%
1
01h
.
.
.
.
.
.
.
.
.
25.098%
64
40h
.
.
.
.
.
.
.
.
.
50.196%
128
80h
.
.
.
.
.
.
.
.
.
100%
255
FFh
4.5 Register 3Eh: Company ID
Register
Address
3Eh
Read/
Write
R
Register
Name
Bit 7
(MSB)
7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
(LSB)
0
Default
Value
01h
Company ID
6
5
4
3
2
1
The company ID register contains the company identification number. For National Semiconductor this is 01h. This number is
assigned by Intel and is a method for uniquely identifying the part manufacturer. This register is read only — a write to this
register has no effect.
4.6 Register 3Fh: Version/Stepping
Register
Address
3Fh
Read/
Write
R
Register
Name
Bit 7
(MSB)
VER3
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
(LSB)
STP0
Default
Value
68h
Version/Stepping
VER2
VER1
VER0
STP3
STP2
STP1
The four least significant bits of the Version/Stepping register [3.0] contain the current stepping of the LM96000 silicon. The four
most significant bits [7.4] reflect the LM96000 base device number when set to a value of 0110b. For the LM96000, this register
will read 01101000b (68h). Bit 3 of the stepping field is set to indicate that the LM96000 is a super-set of the LM85 family of
products.
The register is used by application software to identify which device in the hardware monitor family of ASICs has been
implemented in the given system. Based on this information, software can determine which registers to read from and write to.
Further, application software may use the current stepping to implement work-arounds for bugs found in a specific silicon
stepping.
This register is read only — a write to this register has no effect.
4.7 Register 40h: Ready/Lock/Start/Override
Register Read/ Register
Address Write Name
40h R/W
Bit 7
(MSB)
Bit 6 Bit 5 Bit 4 Bit 3
Bit 2
Bit 1
Bit 0
(LSB)
Default
Value
Ready/Lock/Start/Override RES
RES RES RES OVRID READY LOCK START 00h
13
www.national.com
Functional Description (Continued)
Bit
Name
R/W
Default
Description
0
START
R/W
0
When software writes a 1 to this bit, the LM96000 fan monitoring and PWM
output control functions will use the values set in the fan control limit and
parameter registers (address 5Ch through 6Eh). Before this bit is set, the
LM96000 will not update the used register values, the default values will
remain in effect. Whenever this bit is set to 0, the LM96000 fan monitoring and
PWM output control functions use the default fan limits and parameters,
regardless of the current values in the limit and parameter registers (5C
through 6Eh). The LM96000 will preserve the values currently stored in the
limit and parameter registers when this bit is set or cleared. This bit is not
effected by the state of the Lock bit.
It is expected that all limit and parameter registers will be set by BIOS or
application software prior to setting this bit.
1
LOCK
R/W
0
0
Setting this bit to 1 locks specified limit and parameter registers. Once this bit
is set, limit and parameter registers become read only and will remain locked
until the device is powered off. This register bit becomes read only once it is
set.
2
3
READY
OVRID
R
The LM96000 sets this bit automatically after the part is fully powered up, has
completed the power-up-reset process, and after all A/D converters are
properly functioning.
R/W
If this bit is set to 1, all PWM outputs will go to 100% duty cycle regardless of
whether or not the lock bit is set. The OVRID bit has precedence over the
disabled mode. Therefore, when OVRID is set the PWM will go to 100% even
if the PWM is in the disabled mode.
4–7
Reserved
R
0
Reserved
4.8 Register 41h: Interrupt Status Register 1
Register
Address
41h
Read/
Write
R
Register
Name
Bit 7
(MSB)
ERR
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
(LSB)
2.5V
Default
Value
00h
Interrupt Status 1
ZN3
ZN2
ZN1
5V
3.3V
VCCP
The Interrupt Status Register 1 bits will be automatically set, by the LM96000, whenever a fault condition is detected. A fault
condition is detected whenever a measured value is outside the window set by its limit registers. ZN3 and ZN1 bits will be set
when a diode fault condition, such as a disconect or short, is detected. More than one fault may be indicated in the interrupt
register when read. This register will hold a set bit(s) until the event is read by software. The contents of this register will be
cleared (set to 0) automatically by the LM96000 after it is read by software, if the fault condition is no longer exists. Once set, the
Interrupt Status Register 1 bits will remain set until a read event occurs, even if the fault condition no longer exists
This register is read only — a write to this register has no effect.
Bit
Name
R/W
Default
Description
0
2.5V_Error
R
0
The LM96000 automatically sets this bit to 1 when the 2.5V input voltage
is less than or equal to the limit set in the 2.5V Low Limit register or
greater than the limit set in the 2.5V High Limit register.
1
2
3
VCCP_Error
3.3V_Error
5V_Error
R
R
R
0
0
0
The LM96000 automatically sets this bit to 1 when the VCCP input voltage
is less than or equal to the limit set in the VCCP Low Limit register or
greater than the limit set in the VCCP High Limit register.
The LM96000 automatically sets this bit to 1 when the 3.3V input voltage
is less than or equal to the limit set in the 3.3V Low Limit register or
greater than the limit set in the 3.3V High Limit register.
The LM96000 automatically sets this bit to 1 when the 5V input voltage is
less than or equal to the limit set in the 5V Low Limit register or greater
than the limit set in the 5V High Limit register.
www.national.com
14
Functional Description (Continued)
Bit
Name
R/W
Default
Description
4
Zone 1 Limit
Exceeded
R
0
The LM96000 automatically sets this bit to 1 when the temperature input
measured by the Remote1− and Remote1+ inputs is less than or equal to
the limit set in the Processor (Zone1) Low Temp register or more than the
limit set in the Processor (Zone1) High Temp register. This bit will be set
when a diode fault is detected.
5
6
Zone 2 Limit
Exceeded
R
R
0
0
The LM96000 automatically sets this bit to 1 when the temperature input
measured by the internal temperature sensor is less than or equal to the
limit set in the Internal (Zone2) Low Temp register or greater than the limit
set in the Internal (Zone2) High Temp register.
Zone 3 Limit
Exceeded
The LM96000 automatically sets this bit to 1 when the temperature input
measured by the Remote2− and Remote2+ inputs is less than or equal to
the limit set in the Internal (Zone2) Low Temp register or greater than the
limit set in the Remote (Zone3) High Temp register. This bit will be set
when a diode fault is detected.
7
Error in Status
Register 2
R
0
If there is a set bit in Status Register 2, this bit will be set to 1.
4.9 Register 42h: Interrupt Status Register 2
Register Read/ Register
Bit 7
(MSB)
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1 Bit 0
(LSB) Value
ERR1 FAN4 FAN3 FAN2 FAN1 RES 12V 00h
Default
Address Write
42h
Name
R
Interrupt Status Register 2 ERR2
The Interrupt Status Register 2 bits will be automatically set, by the LM96000, whenever a fault condition is detected. Interrupt
Status Register 2 identifies faults caused by temperature sensor error, fan speed droping below minimum set by the tachometer
minimum register, the 12V input voltage going outside the window set by its limit registers. Interrupt Status Register 2 will hold
a set bit until the event is read by software. The contents of this register will be cleared (set to 0) automatically by the LM96000
after it is ready by software, if fault condition no longer exists. Once set, the Interrupt Status Register 2 bits will remain set until
a read event occurs, even if the fault no longer exists
This register is read only — a write to this register has no effect.
Bit
Name
R/W
Default
Description
0
+12V_Error
R
0
The LM96000 automatically sets this bit to 1 when the 12V input voltage
either falls below the limit set in the 12V Low Limit register or exceeds the
limit set in the 12V High Limit register.
1
2
Reserved
R
R
0
0
Reserved
Fan1 Stalled
The LM96000 automatically sets this bit to 1 when the TACH1 input
reading is above the value set in the Tach1 Minimum MSB and LSB
registers.
3
4
5
6
Fan2 Stalled
Fan3 Stalled
Fan4 Stalled
R
R
R
R
0
0
0
0
The LM96000 automatically sets this bit to 1 when the TACH2 input
reading is above the value set in the Tach2 Minimum MSB and LSB
registers.
The LM96000 automatically sets this bit to 1 when the TACH3 input
reading is above the value set in the Tach3 Minimum MSB and LSB
registers.
The LM96000 automatically sets this bit to 1 when the TACH4 input
reading is above the value set in the Tach4 Minimum MSB and LSB
registers.
Remote Diode
1 Fault
The LM96000 automatically sets this bit to 1 when there is either a short
or open circuit fault on the Remote1+ or Remote1− thermal diode input
pins. A diode fault will also set bit 4, Diode 1 Zone Limit bit, of Interrupt
Status Register 1.
15
www.national.com
Functional Description (Continued)
Bit
Name
R/W
Default
Description
7
Remote Diode
2 Fault
R
0
The LM96000 automatically sets this bit to 1 when there is either a short
or open circuit fault on the Remote2+ or Remote2− thermal diode input
pins. A diode fault will also set bit 6, Diode 2 Zone Limit bit, of Interrupt
Status Register 1.
4.10 Register 43h: VID
Register
Address
43h
Read/
Write
R
Register
Name
Bit 7
(MSB)
RES
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
(LSB)
VID0
Default
Value
VID0–4
RES
RES
VID4
VID3
VID2
VID1
The VID register contains the values of LM96000 VID0–VID4 input pins. This register indicates the status of the VID lines that
interconnect the processor to the Voltage Regulator Module (VRM). Software uses the information in this register to determine the
voltage that the processor is designed to operate at. With this information, software can then dynamically determine the correct
values to place in the VCCP Low Limit and VCCP High Limit registers.
This register is read only — a write to this register has no effect.
4.11 Registers 44-4Dh: Voltage Limit Registers
Register
Address
44h
Read/
Write
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
Register
Name
Bit 7
(MSB)
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
(LSB)
Default
Value
00h
2.5V Low Limit
2.5V High Limit
VCCP Low Limit
VCCP High Limit
3.3V Low Limit
3.3V High Limit
5V Low Limit
5V High Limit
12V Low Limit
12V High Limit
7
7
7
7
7
7
7
7
7
7
6
6
6
6
6
6
6
6
6
6
5
5
5
5
5
5
5
5
5
5
4
4
4
4
4
4
4
4
4
4
3
3
3
3
3
3
3
3
3
3
2
2
2
2
2
2
2
2
2
2
1
1
1
1
1
1
1
1
1
1
0
0
0
0
0
0
0
0
0
0
45h
FFh
00h
46h
47h
FFh
00h
48h
49h
FFh
00h
4Ah
4Bh
FFh
00h
4Ch
4Dh
FFh
If a voltage input either exceeds the value set in the voltage high limit register or falls below the value set in the voltage low limit
register, the corresponding bit will be set automatically by the LM96000 in the interrupt status registers (41-42h). Voltages are
3
presented in the registers at
⁄4 full scale for the nominal voltage, meaning that at nominal voltage, each input will be C0h, as
shown in Table 2.
Setting the Ready/Lock/Start/Override register Lock bit has no effect on these registers.
TABLE 2. Voltage Limits vs Register Setting
Input
Nominal
Voltage
2.5V
Register Setting at
Nominal Voltage
Maximum
Voltage
3.32V
Register Reading at
Maximum Voltage
Minimum
Voltage
0V
Register Reading at
Minimum Voltage
2.5V
VCCP
3.3V
5V
C0h
C0h
C0h
C0h
C0h
FFh
FFh
FFh
FFh
FFh
00h
00h
AFh
00h
00h
2.25V
3.3V
3.00V
0V
4.38V
3.0V
0V
5.0V
6.64V
12V
12.0V
16.00V
0V
4.12 Registers 4E-53h: Temperature Limit Registers
Register
Address
4Eh
Read/
Write
R/W
Register
Name
Bit 7
(MSB)
7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
(LSB)
0
Default
Value
81h
Processor (Zone1)
Low Temp
6
6
5
5
4
4
3
3
2
2
1
1
4Fh
R/W
Processor (Zone1)
High Temp
7
0
7Fh
www.national.com
16
Functional Description (Continued)
Register
Address
50h
Read/
Write
R/W
Register
Name
Bit 7
(MSB)
7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
(LSB)
0
Default
Value
81h
Processor (Zone2)
Low Temp
6
6
6
6
5
5
5
5
4
4
4
4
3
3
3
3
2
2
2
2
1
1
1
1
51h
52h
53h
R/W
R/W
R/W
Processor (Zone2)
High Temp
7
7
7
0
0
0
7Fh
81h
7Fh
Processor (Zone3)
Low Temp
Processor (Zone3)
High Temp
If an external temperature input or the internal temperature sensor either exceeds the value set in the corresponding high limit
register or falls below the value set in the corresponding low limit register, the corresponding bit will be set automatically by the
LM96000 in the Interrupt Status Register 1 (41h). For example, if the temperature read from the Remote1− and Remote1+ inputs
exceeds the Processor (Zone1) High Temp register limit setting, Interrupt Status Register 1 ZN1 bit will be set. The temperature
limits in these registers are represented as 8 bit, 2’s complement, signed numbers in Celsius, as shown below in Table 3.
Setting the Ready/Lock/Start/Override register Lock bit has no effect on these registers.
TABLE 3. Temperature Limits vs Register Settings
Temperature
Reading (Decimal)
Reading (Hex)
−127˚C
−127
81h
.
.
.
.
.
.
.
.
.
−50˚C
−50
CEh
.
.
.
.
.
.
.
.
.
0˚C
0
00h
.
.
.
.
.
.
.
.
.
50˚C
50
32h
.
.
.
.
.
.
.
.
.
127˚C
127
7Fh
4.13 Registers 54-5Bh: Fan Tachometer Low Limit
Register
Address
54h
Read/
Write
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
Register
Name
Bit 7
(MSB)
7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
(LSB)
Default
Value
FFh
Tach1 Minimum LSB
Tach1 Minimum MSB
Tach2 Minimum LSB
Tach2 Minimum MSB
Tach3 Minimum LSB
Tach3 Minimum MSB
Tach4 Minimum LSB
Tach4 Minimum MSB
6
5
4
3
2
1
9
1
9
1
9
1
9
0
8
0
8
0
8
0
8
55h
15
7
14
6
13
5
12
4
11
3
10
2
FFh
56h
FFh
57h
15
7
14
6
13
5
12
4
11
3
10
2
FFh
58h
FFh
59h
15
7
14
6
13
5
12
4
11
3
10
2
FFh
5Ah
FFh
5Bh
15
14
13
12
11
10
FFh
The Fan Tachometer Low Limit registers indicate the tachometer reading under which the corresponding bit will be set in the
Interrupt Status Register 2 register. In Auto Fan Control mode, the fan can run at low speeds, so care should be taken in software
17
www.national.com
Functional Description (Continued)
to ensure that the limit is high enough not to cause sporadic alerts. The fan tachometer will not cause a bit to be set in Interrupt
Status Register 2 if the current value in Current PWM Duty registers is 00h or if the fan 1 disabled via the Fan Configuration
Register. Interrupts will never be generated for a fan if its minimum is set to FF FFh.
Given the insignificance of Bit 0 and Bit 1, these bits could be programmed to remember which fan is which, as follows.
Fan
Bit 1
Bit 0
CPU
0
0
1
1
0
1
0
1
Memory
Chassis Front
Chassis Rear
Setting the Ready/Lock/Start/Override register Lock bit has no effect these registers.
4.14 Registers 5C-5Eh: Fan Configuration
Register Read/ Register
Address Write Name
Bit 7
(MSB)
Bit 6
Bit 5
Bit 4 Bit 3 Bit 2
Bit 1
Bit 0
(LSB) Value
Default Lock?
5Ch
5Dh
5Eh
R/W
R/W
R/W
Fan1 Configuration ZON2 ZON1 ZON0 INV
Fan2 Configuration ZON2 ZON1 ZON0 INV
Fan3 Configuration ZON2 ZON1 ZON0 INV
RES SPIN2 SPIN1 SPIN0 62h
RES SPIN2 SPIN1 SPIN0 62h
RES SPIN2 SPIN1 SPIN0 62h
U
U
U
This register becomes Read Only when the Ready/Lock/Start/Override register Lock bit is set. Any further attempts to write to this
register shall have no effect. After power up the default value is used whenever the Ready/Lock/Start/Override register Start bit
is cleared even though modifications to this register are possible.
Bits [7:5] Zone/Mode
Bits [7:5] of the Fan Configuration registers associate each fan with a temperature sensor. When in Auto Fan Mode the fan will
be assigned to a zone, and its PWM duty cycle will be adjusted according to the temperature of that zone. If ‘Hottest’ option is
selected (101 or 110), the fan will be controlled by the hottest of zones 2 and 3, or of zones 1, 2, and 3. To determine the ‘Hottest’
zone the PWM level for each zone is calculated then the the highest PWM value is selected. When in manual control mode, the
Current PWM duty registers (30h-32h) become Read/Write. It is then possible to control the PWM outputs with software by writing
to these registers. When the fan is disabled (100) the corresponding PWM output should be driven low (or high, if inverted).
Zone 1: External Diode 1 (processor)
Zone 2: Internal Sensor
Zone 3: External Diode 2
TABLE 4. Fan Zone Setting
ZON[2:0]
000
Fan Configuration
Fan on zone 1 auto
001
Fan on zone 2 auto
010
Fan on zone 3 auto
011
Fan always on full
100
Fan disabled
101
Fan controlled by hottest of zones 2, 3
Fan controlled by hottest of zones 1, 2, 3
Fan manually controlled (Test Mode)
110
111
Bit [4] PWM Invert
Bit [4] inverts the PWM output. If set to 0, 100% duty cycle will yield an output that is always high. If set to 1, 100% duty cycle
will yield an output that is always low.
Bit [3] Reserved
Bits [2:0] Spin Up
Bits [2:0] specify the ‘spin up’ time for the fan. When a fan is being started from a stationary state, the PWM output is held at 100%
duty cycle for the time specified in the table below before scaling to a lower speed.
www.national.com
18
Functional Description (Continued)
TABLE 5. Fan Spin-Up Register
SPIN[2:0]
000
Spin Up Time
0 sec
001
100 ms
010
250 ms
011
400 ms
100
700 ms
101
1000 ms
2000 ms
4000 ms
110
111
4.15 Registers 5F-61h: Auto Fan Speed Range, PWM Frequency
Register Read/ Register
Address Write Name
Bit 7
(MSB)
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
(LSB) Value
Default Lock?
5Fh
60h
61h
R/W
R/W
R/W
Zone1 Range/Fan1 RAN3 RAN2 RAN1 RAN0 HLFRQ FRQ2 FRQ1 FRQ0 C4h
U
U
U
Frequency
Zone2 Range/Fan2 RAN3 RAN2 RAN1 RAN0 HLFRQ FRQ2 FRQ1 FRQ0 C4h
Frequency
Zone3 Range/Fan3 RAN3 RAN2 RAN1 RAN0 HLFRQ FRQ2 FRQ1 FRQ0 C4h
Frequency
In Auto Fan Mode, when the temperature for a zone is above the Temperature Limit (Registers 67-69h) and below its Absolute
Temperature Limit (Registers 6A-6Ch), the speed of a fan assigned to that zone is determined as follows.
When the temperature reaches the Fan Temp Limit for a zone, the PWM output assigned to that zone will be Fan PWM Minimum.
Between Fan Temp Limit and (Fan Temp Limit + Range), the PWM duty cycle will increase linearly according to the temperature
as shown in the figure below. The PWM duty cycle will be 100% at (Fan Temp Limit + Range).
20084606
FIGURE 1. Fan Activity above Fan Temp Limit
Example for PWM1 assigned to Zone 1:
– Zone 1 Fan Temp Limit (Register 67h) is set to 50˚C (32h).
– Range (Register 5Fh) is set to 8˚C (6xh).
– Fan 1 PWM Minimum (Register 64h) is set to 50% (32h).
In this case, the PWM1 duty cycle will be 50% at 50˚C.
Since (Zone 1 Fan Temp Limit) + (Zone 1 Range) = 50˚C + 8˚C = 58˚C, the fan will run at 100% duty cycle when the temperature
of the Zone 1 sensor reaches 58˚C.
Since the midpoint of the fan control range is 54˚C, and the median duty cycle is 75% (Halfway between the PWM Minimum and
100%), PWM1 duty cycle would be 75% at 54˚C.
19
www.national.com
Functional Description (Continued)
Above (Zone 1 Fan Temp Limit) + (Zone 1 Range), the duty cycle will be 100%.
PWM frequency bits [3:0]
The PWM frequency bits [3:0] determine the PWM frequency for the fan.The LM96000 has high and low frequency ranges for the
PWM outputs, that are controlled by the HLFRQ bit.
PWM Frequency Selection (Default = 0011 = 30.04 Hz).
TABLE 6. Register Setting vs PWM Frequency
HLFRQ
Freq [2:0]
000
001
010
011
PWM Frequency
10.01 Hz
15.02 Hz
23.14 Hz
30.04 Hz
38.16 Hz
47.06 Hz
61.38 Hz
94.12 Hz
22.5 kHz
24 kHz
0
0
0
0
0
0
0
0
1
1
1
1
1
1
1
1
100
101
110
111
000
001
010
011
25.7 kHz
25.7 kHz
27.7 kHz
27.7 kHz
30 kHz
100
101
110
111
30 kHz
Range Selection RAN [3:0]
RAN [3:0]
Range (˚C)
0000
0001
0010
0011
0100
0101
0110
0111
1000
1001
1010
1011
1100
1101
1110
1111
2
2.5
3.33
4
5
6.67
8
10
13.33
16
20
26.67
32
40
53.33
80
This register becomes Read Only when the Ready/Lock/Start/Override register Lock bit is set. Any further attempts to write to this
register shall have no effect. After power up the default value is used whenever the Ready/Lock/Start/Override register Start bit
is cleared even though modifications to this register are possible.
4.16 Registers 62, 63h: Min/Off, Spike Smoothing
Register Read/ Register
Address Write Name
Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Default Lock?
(MSB) (LSB) Value
62h
R/W
Min/Off, Zone1 Spike Smoothing OFF3 OFF2 OFF1 RES ZN1E ZN1-2 ZN1-1 ZN1-0 00h
U
www.national.com
20
Functional Description (Continued)
Register Read/ Register
Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Default Lock?
(MSB) (LSB) Value
Zone2, Zone3 Spike Smoothing ZN2E ZN2-2 ZN2-1 ZN2-0 ZN3E ZN3-2 ZN3-1 ZN3-0 00h
Address Write Name
63h R/W
U
The Off/Min Bits [7:5] specify whether the duty cycle will be 0% or Minimum Fan Duty when the measured temperature falls below
the Temperature LIMIT register setting (see table below). OFF1 applies to fan 1, OFF2 applies to fan 2, and OFF3 applies to fan
3.
If the Remote1 or Remote2 pins are connected to a processor or chipset, instantaneous temperature spikes may be sampled by
the LM96000. If these spikes are not ignored, the CPU fan (if connected to LM96000) may turn on prematurely and produce
unpleasant noise. For this reason, any zone that is connected to a chipset or processor should have spike smoothing enabled.
When spike smoothing is enabled, the temperature reading registers will still reflect the current value of the temperature — not
the ‘smoothed out’ value.
ZN1E, ZN2E, and ZN3E enable temperature smoothing for zones 1, 2, and 3 respectively.
ZN1-2, ZN1-1, and ZN1-0 control smoothing time for Zone 1.
ZN2-2, ZN2-1, and ZN2-0 control smoothing time for Zone 2.
ZN3-2, ZN3-1, and ZN3-0 control smoothing time for Zone 3.
These registers become ready only when the Ready/Lock/Start/Override register Lock bit is set. Any further attempts to write to
these registers shall have no effect.
20084607
FIGURE 2. What LM96000 Auto Fan Control Sees With and Without Spike Smoothing
TABLE 7. Spike Smoothing
ZN-X[2:0]
000
Spike Smoothed Over
35 seconds
001
17.6 seconds
11.8 seconds
7.0 seconds
010
011
100
4.4 seconds
101
3.0 seconds
110
1.6 seconds
111
.8 seconds
TABLE 8. PWM Output Below Limit Depending on Value of Off/Min
Off/Min
PWM Action
0
1
At 0% duty below LIMIT
At Min PWM Duty below LIMIT
21
www.national.com
Functional Description (Continued)
4.17 Registers 64-66h: Minimum PWM Duty Cycle
Register Read/ Register
Bit 7
(MSB)
Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0
(LSB) Value
80h
80h
80h
Default Lock?
Address Write
Name
64h
65h
66h
R/W
R/W
R/W
Fan1 PWM Minimum
Fan2 PWM Minimum
Fan3 PWM Minimum
7
7
7
6
6
6
5
5
5
4
4
4
3
3
3
2
2
2
1
1
1
0
U
U
U
0
0
These registers specify the minimum duty cycle that the PWM will output when the measured temperature reaches the
Temperature LIMIT register setting.
This register becomes Read Only when the Ready/Lock/Start/Override register Lock bit is set. Any further attempts to write to this
register shall have no effect. After power up the default value is used whenever the Ready/Lock/Start/Override register Start bit
is cleared even though modifications to this register are possible.
TABLE 9. PWM Duty vs Register Setting for PWM Low Frequency Range
Current Duty
Value (Decimal)
Value (Hex)
0%
0
00h
0.3922%
1
01h
.
.
.
.
.
.
.
.
.
25.098%
64
40h
.
.
.
.
.
.
.
.
.
50.196%
128
80h
.
.
.
.
.
.
.
.
.
100%
255
FF
PWM Duty Cycle vs Register Setting for PWM High Frequency Range
22.5KHz PWM Frequency
24KHz PWM Frequency
PWM Duty Cycle
PWM Duty Cycle
Level (%)
0.00
Value in Decimal
0
Value in Hex
0
Level (%)
0
Value in Decimal
0
Value in Hex
0
6.25
1 - 15
01 - 0F
10 - 1F
20 - 2F
30 - 3F
40 - 4F
50 - 5F
60 - 6F
70 - 7F
80 - 8F
90 - 9F
A0 - AF
B0 - BF
C0 - CF
D0 - DF
E0 - EF
F0 - FF
6.67
1 - 16
01 - 10
11 - 21
22 - 32
33 - 43
44 - 54
55 - 65
66 - 76
77 - 88
89 - 99
9A - AA
AB - BB
BC - CC
CD - DD
DE - EE
EF - FF
12.50
16 - 31
13.33
20.00
26.67
33.33
40.00
46.67
53.33
60.00
66.67
73.33
80.00
86.67
93.33
100.00
17 - 33
18.75
32 - 47
34 - 50
25.00
48 - 63
51 - 67
31.25
64 - 79
68 - 84
37.50
80 - 95
85 - 101
102 - 118
119 - 136
137 - 153
154 - 170
171 - 187
188 - 204
205 - 221
222 - 238
239 - 255
43.75
96 - 111
112 - 127
128 - 143
144 - 159
160 - 175
176 - 191
192 - 207
208 - 223
224 - 239
240 - 255
50.00
56.25
62.50
68.75
75.00
81.25
87.50
93.75
100.00
www.national.com
22
Functional Description (Continued)
27.7KHz PWM Frequency
PWM Duty Cycle
25.7KHz PWM Frequency
PWM Duty Cycle
Level (%)
46.15
Value in Decimal
98 - 117
Value in Hex
62 - 75
Level (%)
0
Value in Decimal
0
Value in Hex
0
53.85
118 - 137
138 - 157
158 - 176
177 - 196
197 - 216
217 - 235
236 - 255
76 - 89
61.54
8A - 9D
9E - B0
B1 - C4
C5 - D8
D9 - EB
EC - FF
7.14
1 - 17
01 - 11
12 - 24
25 - 36
37 - 48
49 - 5A
5B - 6D
6E - 7F
80 - 91
92 - A4
A5 - B6
B7 - C8
C9 - DA
DB - ED
EE - FF
69.23
14.29
21.43
28.57
35.71
42.86
50.00
57.14
64.29
71.43
78.57
85.71
92.86
100.00
18 - 36
76.92
37 - 54
84.62
55 - 72
92.31
73 - 90
100.00
91 - 109
110 - 127
128 - 145
146 - 164
165 - 182
183 - 200
201 - 218
219 - 237
238 - 255
30KHz PWM Frequency
PWM Duty Cycle
Level (%)
0
Value in Decimal
0
Value in Hex
0
8.33
1 - 20
01 - 14
15 - 2A
2B - 3F
40 - 54
55 - 6A
6B - 7F
80 - 94
95 - AA
AB - BF
C0 - D4
D5 - EA
EB - FF
16.67
21 - 42
25.00
43 - 63
33.33
64 - 84
41.67
85 - 106
107 - 127
128 - 148
149 - 170
171 - 191
192 - 212
213 - 234
235 - 255
27.7KHz PWM Frequency
50.00
PWM Duty Cycle
58.33
Level (%)
0
Value in Decimal
0
Value in Hex
0
66.67
75.00
7.69
1 - 19
01 - 13
14 - 26
27 - 3A
3B - 4E
4F - 61
83.33
15.38
23.08
30.77
38.46
20 - 38
39 - 58
59 - 78
79 - 97
91.67
100.00
4.18 Registers 67-69h: Temperature Limit
Register Read/ Register
Bit 7
Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0
Default Lock?
Address Write
Name
(MSB)
(LSB) Value
5Ah
5Ah
5Ah
67h
68h
69h
R/W
R/W
R/W
Zone1 Fan Temp Limit
Zone2 Fan Temp Limit
Zone3 Fan Temp Limit
7
7
7
6
6
6
5
5
5
4
4
4
3
3
3
2
2
2
1
1
1
0
U
U
U
0
0
These are the temperature limits for the individual zones. When the current temperature equals this limit, the fan will be turned
on if it is not already. When the temperature exceeds this limit, the fan speed will be increased according to the algorithm set forth
in the Auto Fan Range, PWM Frequency register description. Default = 90˚C = 5Ah
This register becomes Read Only when the Ready/Lock/Start/Override register Lock bit is set. Any further attempts to write to this
register shall have no effect. After power up the default value is used whenever the Ready/Lock/Start/Override register Start bit
is cleared even though modifications to this register are possible.
TABLE 10. Temperature Limit vs Register Setting
Temperature Reading (Decimal)
Reading (Hex)
−127˚C
−127
81h
.
.
.
.
.
.
.
.
.
−50˚C
−50
CEh
.
.
.
.
.
.
.
.
.
23
www.national.com
Functional Description (Continued)
TABLE 10. Temperature Limit vs Register Setting (Continued)
Temperature Reading (Decimal)
Reading (Hex)
0˚C
0
00h
.
.
.
.
.
.
.
.
.
50˚C
50
32h
.
.
.
.
.
.
.
.
.
127˚C
127
7Fh
4.19 Registers 6A-6Ch: Absolute Temperature Limit
Register Read/
Address Write
Register
Name
Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Default Lock?
(MSB)
(LSB)
Value
64h
6Ah
6Bh
6Ch
R/W
R/W
R/W
Zone1 Absolute Temp Limit
Zone2 Absolute Temp Limit
Zone3 Absolute Temp Limit
7
7
7
6
6
6
5
5
5
4
4
4
3
3
3
2
2
2
1
1
1
0
0
0
U
U
U
64h
64h
In the Auto Fan mode, if a zone exceeds the temperature set in the Absolute Temperature Limit register, all of the PWM outputs
will incresase its duty cycle to 100%. This is a safety feature that attempts to cool the system if there is a potentially catastrophic
thermal event. If set to 80h (-128˚C), the feature is disabled. Default=100˚C=64h
These registers become Read Only when the Ready/Lock/Start/Override register Lock bit is set. Any further attempts to write to
these registers shall have no effect. After power up the default values are used whenever the Ready/Lock/Start/Override register
Start bit is cleared even though modifications to these registers are possible.
TABLE 11. Absolute Limit vs Register Setting
Temperature Reading (Decimal)
Reading (Hex)
−127˚C
−127
81h
.
.
.
.
.
.
.
.
.
−50˚C
−50
CEh
.
.
.
.
.
.
.
.
.
0˚C
0
00h
.
.
.
.
.
.
.
.
.
50˚C
50
32h
.
.
.
.
.
.
.
.
.
127˚C
127
7Fh
4.20 Registers 6D-6Eh: Zone Hysteresis Registers
Register Read/ Register
Address Write Name
Bit 7
(MSB)
Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0
Default Lock?
(LSB) Value
6Dh
6Eh
R/W
R/W
Zone1 and Zone2 Hysteresis H1-3
Zone3 Hysteresis H3-3
H1-2 H1-1 H1-0 H2-3 H2-2 H2-1 H2-0
H3-2 H3-1 H3-0 RES RES RES RES
44h
40h
U
U
If the temperature is above Fan Temp Limit, then drops below Fan Temp Limit, the following will occur:
www.national.com
24
Functional Description (Continued)
– The fan will remain on, at Fan PWM Minimum, until the temperature goes a certain amount below Fan Temp Limit.
– The Hysteresis registers control this amount. See below table for details.
These registers become Read Only when the Ready/Lock/Start/Override register Lock bit is set. Any further attempts to write to
thses registers shall have no effect. After power up the default value is used whenever the Ready/Lock/Start/Override register
Start bit is cleared even though modifications to this register are possible.
TABLE 12. Hysteresis Settings
Setting
HYSTERESIS
0h
0˚C
.
.
.
.
.
.
5h
.
5˚C
.
.
.
.
.
Fh
15˚C
4.21 Register 6Fh: Test Register
Register
Address
6Fh
Read/
Write
R/W
Register
Name
Bit 7
(MSB)
Bit 6
Bit 5
Bit 4
Bit 3
RES
Bit 2
Bit 1
Bit 0
(LSB)
XEN
Default
Value
00h
Test Register
RES
RES
RES
RES
RES
RES
If the XEN bit is set high, the part will be placed into XOR tree test mode. Clearing the bit (writing a 0 to the XEN bit) brings the
part out of XOR tree test mode.
This register becomes Read Only when the Ready/Lock/Start/Override register Lock bit is set. Any further attempts to write to this
registers shall have no effect. After power up the default value is used whenever the Ready/Lock/Start/Override register Start bit
is cleared even though modifications to this register are possible.
4.22 Registers 70-7Fh: Vendor Specific Registers
These registers are for vendor specific features, including test registers. They will not default to a specific value on power up.
4.22.1 Register 74h: Tachometer Monitor Mode
Register Read/
Address Write
Register
Name
Bit 7
(MSb)
Bit 6
Bit 5
Bit 4
Bit 3 Bit 2 Bit 1
T2-0 T1-1
Bit 0
(LSb)
T1-0
Default Lock?
Value
74h
R/W
Tach Monitor Mode RES
RES
T3/4-1 T3/4-0 T2-1
00h
Each fan TACH input has 4 possible modes of operation when using the low frequency range for the PWM outputs. Mode 0 is the
only mode that is available when using the high frequecy range for the PWM outputs. The modes for TACH3 and TACH4 share
control bits T3/4-[1:0]; TACH2 is controlled by T2-[1:0]; TACH1 is controlled by T1-[1:0]. The result reported in all modes is based
on 2 pulses per revolution. In order for modes 2 and 3 to function properly it is required that the:
PWM1 output must control the fan that has it’s tachometer output connected to the TACH1 LM96000 input.
PWM2 output must control the fan that has it’s tachometer output connected to the TACH2 LM96000 input.
PWM3 output must control the fans that have their tachometer outputs connected to the TACH3 or TACH4 LM96000 inputs.
Setting (Tn[1:0]) Mode Function
00
01
10
11
0
1
2
3
Traditional tach input monitor, false readings when under minimum detctable RPM
Traditional tach input monitor, FFFFh reading when under minimum detectable RPM
Most accurate readings, FFFFh reading when under minimum detectable RPM
Least effect on programmed PWM of Fan, FFFFh reading when under minimum detectable RPM
•
•
Mode 0: This mode uses the conventional method for fan tachometer pulse detection and does not include any circuitry to
compensate for PWM Fan drive. This mode should be used when PWM drive is not used to power the fan. This mode may
report a false RPM reading when under minimum detectable RPM as shown in the following table.
Mode 1: This mode uses the conventional method for fan tach detection. The reading will be FFFFh if it is below minimum
detectable RPM.
25
www.national.com
Functional Description (Continued)
•
Mode 2: This mode is optimized for accurate RPM readings and activates circuitry that extends the lower side of the RPM
reading as shown in the following table.
•
Mode 3: This mode minimizes the effect on the RPM setting and activates circuitry that extends the lower side of the RPM
reading as shown in the following table.
PWM Frequency
10.01
Mode 0 and 1 Minimum RPM
Mode 2 and 3 Minimum RPM
841
210
315
420
420
420
420
420
420
15.02
1262
1944
2523
3205
3953
5156
7906
23.14
30.04
38.16
47.06
61.38
94.12
This register is not effected when the Ready/Lock/Start/Override register Lock bit is set. After power up the default value is used
whenever the Ready/Lock/Start/Override register Start bit is cleared even though modifications to this register are possible.
4.22.2 Register 75h: Fan Spin-up Mode
Register Read/
Address Write
Register
Name
Bit 7 Bit 6 Bit 5 Bit 4 Bit 3
(MSB)
Bit 2
Bit 1
Bit 0
(LSB)
Default Lock?
Value
75h
R/W Fan Spin-up Mode RES RES RES RES RES PWM3 SU PWM2 SU PWM1 SU
7h
U
The PWM SU bit configures the PWM spin-up mode. If PWM SU is cleared the spin-up time will terminate after time programmed
by the Fan Configuration register has elapsed. When set to a 1, the spin-up time will terminate early if the TACH reading exceeds
the Tach Minimum value or after the time programmed by the Fan Configuration register has elapsed, whichever occurs first.
This register becomes Read Only when the Ready/Lock/Start/Override register Lock bit is set. Any further attempts to write to this
register shall have no effect. After power up the default value is used whenever the Ready/Lock/Start/Override register Start bit
is cleared even though modifications to this register are possible.
4.23 Undefined Registers
Any reads to undefined registers will always return 00h. Writes to undefined registers will have no effect and will not return an
error.
5.0 XOR TEST MODE
The LM96000 incorporates a XOR tree test mode. When the test mode is enabled by setting the “XEN” bit high in the Test
Register at address 6Fh via the SMBus, the part will enter XOR test mode.
Since the test mode an XOR tree, the order of the signals in the tree is not important. SMBDAT and SMBCLK are not to be
included in the test tree.
20084608
www.national.com
26
Applications Information
20084609
Typical Applications Schematic
27
www.national.com
Physical Dimensions inches (millimeters) unless otherwise noted
24-Lead Molded TSSOP Package,
Order Number LM96000CIMT or LM96000CIMTX
NS Package Number MTC24E
JEDEC Registration MO-153, Variation AD
National does not assume any responsibility for use of any circuitry described, no circuit patent licenses are implied and National reserves
the right at any time without notice to change said circuitry and specifications.
For the most current product information visit us at www.national.com.
LIFE SUPPORT POLICY
NATIONAL’S PRODUCTS ARE NOT AUTHORIZED FOR USE AS CRITICAL COMPONENTS IN LIFE SUPPORT DEVICES OR SYSTEMS
WITHOUT THE EXPRESS WRITTEN APPROVAL OF THE PRESIDENT AND GENERAL COUNSEL OF NATIONAL SEMICONDUCTOR
CORPORATION. As used herein:
1. Life support devices or systems are devices or systems
which, (a) are intended for surgical implant into the body, or
(b) support or sustain life, and whose failure to perform when
properly used in accordance with instructions for use
provided in the labeling, can be reasonably expected to result
in a significant injury to the user.
2. A critical component is any component of a life support
device or system whose failure to perform can be reasonably
expected to cause the failure of the life support device or
system, or to affect its safety or effectiveness.
BANNED SUBSTANCE COMPLIANCE
National Semiconductor certifies that the products and packing materials meet the provisions of the Customer Products Stewardship
Specification (CSP-9-111C2) and the Banned Substances and Materials of Interest Specification (CSP-9-111S2) and contain no ‘‘Banned
Substances’’ as defined in CSP-9-111S2.
National Semiconductor
Americas Customer
Support Center
National Semiconductor
Europe Customer Support Center
Fax: +49 (0) 180-530 85 86
National Semiconductor
Asia Pacific Customer
Support Center
National Semiconductor
Japan Customer Support Center
Fax: 81-3-5639-7507
Email: new.feedback@nsc.com
Tel: 1-800-272-9959
Email: europe.support@nsc.com
Deutsch Tel: +49 (0) 69 9508 6208
English Tel: +44 (0) 870 24 0 2171
Français Tel: +33 (0) 1 41 91 8790
Email: ap.support@nsc.com
Email: jpn.feedback@nsc.com
Tel: 81-3-5639-7560
www.national.com
相关型号:
LM96000CIMT/NOPB
IC 1-CHANNEL POWER SUPPLY SUPPORT CKT, PDSO24, MO-153AD, TSSOP-24, Power Management Circuit
NSC
LM96063CISDX
Switch/Digital Output Temperature Sensor, DIGITAL TEMP SENSOR-SERIAL, 11BIT(s), 3Cel, SQUARE, SURFACE MOUNT, MO-299WEED-5, LLP-10
TI
©2020 ICPDF网 联系我们和版权申明