NIPXIE-8105 [NI]
2.0 GHz Dual-Core Embedded Controller for PXI Express; 2.0 GHz的双核嵌入式控制器PXI Express的型号: | NIPXIE-8105 |
厂家: | National Instruments |
描述: | 2.0 GHz Dual-Core Embedded Controller for PXI Express |
文件: | 总6页 (文件大小:362K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
2.0 GHz Dual-Core Embedded Controller for PXI Express
NI PXIe-8105
• Intel Core Duo processor T2500
(2.0 GHz dual core)
Software
• OS and drivers already installed
• Up to 1 GB/s system bandwidth
• Up to 1 GB/s slot bandwidth
• 512 MB (1 x 512 MB DIMM) dual-channel
667 MHz DDR2 RAM standard,
• Hard drive-based recovery image
PXI Express System Configuration
• Complete PXI Express system
configuration at ni.com/pxiadvisor
4 GB (2 x 2 GB DIMMs) maximum
• Integrated I/O
• 10/100/1000BASE-TX Ethernet
• 4 Hi-Speed USB ports
• ExpressCard/34 slot
• DVI-I video connector
• GPIB (IEEE 488) controller
• RS232 serial port
• IEEE 1284 ECP/EPP parallel port
• Integrated hard drive
• Internal PXI trigger bus routing
• Watchdog timer
Overview
Dual-Core Processor
The National Instruments PXIe-8105 is a high-performance Intel Core
Duo processor T2500-based embedded controller for use in PXI Express
and CompactPCI Express systems. With its 2.0 GHz dual-core processor
and dual-channel 667 MHz DDR2 memory, the NI PXIe-8105 is ideal for
applications requiring intensive analysis or system development. An
NI PXIe-8105 embedded controller in a PXI Express chassis, such as the
NI PXIe-1062Q, offers a compact, high-performance PC platform for
modular instrumentation and data acquisition applications.
The NI PXIe-8105 includes the dual-core Intel Core Duo processor T2500.
Dual-core processors contain two cores, or computing engines, in one
physical processor. This enables dual-core processors to simultaneously
execute two computing tasks, which is advantageous in multitasking
environments, such as Windows XP, where multiple applications run
simultaneously. Two applications, such as NI LabVIEW and Microsoft
Excel, each execute on a separate core at the same time. This improves
overall system performance. Multithreaded applications, such as
LabVIEW, take full advantage of dual-core processors because they
separate their tasks into independent threads. A dual-core processor can
simultaneously execute two of these threads.
CPU
Intel Core Duo processor T2500
(2.0 GHz Dual Core)
667 MHz
Front-side bus
L2 cache
2048 KB
System bandwidth
Up to 1 GB/s
Slot bandwidth
Up to 1 GB/s
PXI Express 4-link configuration
PXI Express 2-link configuration
Dual-channel 667 MHz DDR2 RAM, standard
Dual-channel 667 MHz DDR2 RAM, maximum
Hard drive, minimum
3 x4 links and 1 x1 link
2 x4 links
512 MB (1 x 512 MB)
4 GB (2 x 2 GB)
60 GB SATA1
10/100/1000BASE-TX Ethernet
GPIB (IEEE 488) controller
Serial port (RS232)
ꢀ
ꢀ
ꢀ
Parallel port
ꢀ
Hi-Speed USB ports
4
ExpressCard/34 slot
ꢀ
–
2
PS/2 keyboard/mouse connector
Watchdog/trigger SMB
Installed OS
ꢀ
Windows XP Professional3
130 GB PATA hard drive for extended temperature option
Figure 1. This NI PXIe-8105 controls an 8-slot PXI Express modular instrumentation and
data acquisition system.
2For a legacy PS/2 keyboard and mouse, add the USB-to-dual-PS/2 adapter
3Contact National Instruments or visit ni.com/pxiadvisor for information on other available operating systems
Table 1. NI PXIe-8105 Features
2.0 GHz Dual-Core Embedded Controller for PXI Express
Intel Core 2 Duo
CPU
Hardware
With state-of-the-art packaging, the NI PXIe-8105 embedded controller
integrates the Intel Core Duo processor T2500 and all standard and
extended PC I/O ports into a single unit. By integrating many I/O ports on
the controller, all active slots in the PXI Express chassis remain available
for measurement modules. This rugged one-piece controller design
minimizes integration issues and eliminates the need for complex cabling
to daughter boards. The NI PXIe-8105 also uses the Mobile Intel 945GM
Chipset
Graphics
Memory
Controller
Hub
2 SO-DIMM
DDR2 SDRAM
PC2 5400
DUAL CH
DVI-I
Connector
PCI Bus
GPIB
ExpressCard/34
DMI Interface
Express chipset to deliver maximum performance, flexibility, and stability.
A block diagram of the NI PXIe-8105 is shown in Figure 2.
3 x4 PCIe
Links
4 Hi-Speed
USB Ports
Chipset
I/O Controller
Hub
PXI Express
Connector/
Triggers
PCIe
Switch
x4
PCIe
Link
Peripheral I/O
Gigabit
Ethernet
x1 PCIe Link
The NI PXIe-8105 includes high-performance peripheral I/O such as
10/100/1000BASE-TX (gigabit) Ethernet and four Hi-Speed USB ports
for connection to a keyboard, a mouse, a CD-ROM/DVD-ROM drive for
software installation, or other standard PC peripherals such as speakers,
printers, or memory sticks. Use the IEEE 1284 ECP/EPP parallel port to
connect to a wide variety of devices, including tape backup drives,
printers, and scanners. An RS232 port is available for connecting to
serial devices. Additionally, the NI PXIe-8105 includes an integrated GPIB
(IEEE 488) controller, which provides control of external instrumentation,
saving additional cost and a slot.
LPC Bus
Hard Drive
SMB to
Triggers
LPT 1
Super I/O
COM 1
Watchdog
SMB
Figure 2. NI PXIe-8105 Block Diagram
DDR2 SDRAM. 512 MB (1 x 512 MB DIMM) of RAM is standard with the
NI PXIe-8105, with upgrade options to either 1, 2, 3, or 4 GB.
ExpressCard
The NI PXIe-8105 includes an ExpressCard/34 slot. ExpressCard uses the
PCI Express and Hi-Speed USB serial interfaces to provide up to 2.5 Gb/s
of bidirectional throughput. Use the ExpressCard/34 slot to add a second
gigabit Ethernet port to your system or additional peripheral I/O such as
external SATA hard drives, 802.11 wireless LAN, IEEE 1394, Bluetooth,
or various memory adapters.
Extended Temperature Option
The NI PXIe-8105 is available in two versions to address different
environmental conditions. The basic version has an operating temperature
of 5 to 50 °C and a storage temperature of -40 to 65 °C. The extended-
temperature version has an operating temperature of 0 to 55 °C and a
storage temperature of -40 to 71 °C. The primary difference is that the
extended-temperature option uses a hard drive designed for reliability in
Video
The NI PXIe-8105 features the integrated Intel Graphics Media Accelerator low- and high-temperature extremes. This extended temperature hard
950, which delivers intense, realistic 3D graphics with sharp images, fast
rendering, smooth motion, and high detail, without the need for an additional
video card or peripheral. This unique architecture provides balanced
memory usage between graphics and the system for optimal performance.
drive has a capacity of 30 GB (minimum) versus 60 GB (minimum) on the
standard controller. See specifications for further details.
Software
Additionally, the NI PXIe-8105 includes a DVI-I video connector, compatible The NI PXIe-8105 comes with the following minimum set of software
with digital (DVI) and analog (VGA) monitors. A DVI-I to VGA adapter is
included with the controller for use with VGA monitors.
already installed:
• Microsoft Windows XP Professional OS (contact National Instruments
or visit ni.com/pxiadvisor for localized versions of Windows XP and
for other available operating systems)
Memory
The NI PXIe-8105 uses dual-channel 667 MHz DDR2 SDRAM. This feature • Hard drive-based recovery image
makes the controllers ideal for data-intensive applications requiring
significant analysis. The NI PXIe-8105 has two SO-DIMM sockets for the
• NI-VISA and NI-488.2 drivers
• Drivers for all built-in I/O ports (Table 1)
BUY ONLINE at ni.com or CALL 800 813 3693 (U.S.)
2
2.0 GHz Dual-Core Embedded Controller for PXI Express
With NI Factory Installation Services (FIS) added to a PXI Express
USB Peripherals
system order, your embedded controller is shipped already configured
with all software and drivers applicable for your system. For example,
assume you order a PXI Express system that includes LabVIEW and
NI TestStand software, as well as data acquisition modules, a digitizer,
an arbitrary waveform generator, and a digital multimeter (DMM).
With FIS, NI not only assembles and tests your system but also fully
configures the embedded controller with the appropriate NI-DAQmx,
NI-SCOPE, NI-FGEN, and NI-DMM drivers, as well as LabVIEW and
NI TestStand. Additionally, your embedded controller is configured with
a hard drive-based recovery image, so you can restore your controller to
the as-shipped configuration at any time. This combination of software
configuration and recovery tools provides both a productive and reliable
development experience with your PXI Express system out of the box.
To configure a complete PXI Express system with FIS, contact
National Instruments or visit ni.com/pxiadvisor.
National Instruments offers a USB-to-dual-PS/2 keyboard/mouse adapter
cable to connect a legacy PS/2 keyboard and mouse to a single USB port
on your embedded controller. Additionally, NI offers external USB
CD-ROM/DVD-ROM and USB floppy drives for use with your embedded
controller. Using the USB interfaces, connect these drives to your
embedded controller for easy software installation and upgrades. Both
are completely powered through the USB port, so no external power
connections are required. Additional USB peripherals, such as USB
speakers to add audio or USB memory sticks to add easily removable
memory, are widely available from PC peripheral manufacturers.
Additional Peripheral Ports
National Instruments offers numerous plug-in modules to add more
peripherals and ports to your PXI Express system. With the wide variety
of peripheral devices available, you can choose modules that add
communication with serial, IEEE 1394, and SCSI, in addition to numerous
others. You also can obtain modules for controlling other PXI or VXI/VME
systems. Visit ni.com/pxiadvisor to configure a system with additional
peripheral modules.
Ordering Information
Step 4. Accessories2
For online configuration of a complete PXI Express system, including
USB-to-dual-PS/2 keyboard/mouse adapter cable ..............778713-02
External USB CD-ROM/DVD-ROM drive ..............................778492-01
External USB floppy drive......................................................778492-02
Spare DVI-I to VGA adapter ..................................................778713-03
Parallel port adapter cable (6 in.)..........................................777169-01
Micro-GPIB to GPIB adapter cable (0.2 m) ........................183285-0R2
Micro-GPIB to GPIB cable (1 m) ............................................183285-01
Micro-GPIB to GPIB cable (2 m) ............................................183285-02
ExpressCard strain-relief accessory
Factory Installation Services, visit ni.com/pxiadvisor.
Step 1. Controller Model – select one of the following.
NI PXIe-8105
Base ..................................................................................779710-xx
Extended Temperature ......................................................779711-xx
Step 2. Replace “xx” to select installed OS.
01....................................................Windows XP Professional (English)
00..................................................Localized Windows XP or Other OS1
1Contact National Instruments or visit ni.com/pxiadvisor for the latest
operating systems.
for embedded controller....................................................192524-01
USB English keyboard and optical mouse ............................779660-01
Flat panel monitor with VGA input ......................................779559-01
NI FPT-1015 15 in. flat panel touch screen with
Step 3. Memory upgrades – select the amount of
upgrade memory.
Standard:
VGA interface and USB ....................................................779560-01
512 MB (1 x 512 MB DIMM)
2For additional peripheral modules, including serial, IEEE 1394, and SCSI, visit
Recommended upgraded memory configurations:
1 GB (1 x 512 MB DIMM must be purchased)
2 GB (2 x 1 GB DIMMs must be purchased)
4 GB (2 x 2 GB DIMMs must be purchased)
512 MB DDR2 RAM ............................................................779302-512
1 GB DDR2 RAM................................................................779302-1024
2 GB DDR2 RAM................................................................780031-2048
ni.com/pxiadvisor.
BUY NOW!
For complete product specifications, pricing, and accessory
information, call 800 813 3693 (U.S.) or go to ni.com/pxi.
BUY ONLINE at ni.com or CALL 800 813 3693 (U.S.)
3
2.0 GHz Dual-Core Embedded Controller for PXI Express
Specifications
Specifications subject to change without notice.
Features
Processor................................................................................ Intel Core Duo processor T2500 (2.0 GHz dual core)
Chipset ................................................................................... Mobile Intel 945GM Express chipset
Ethernet.................................................................................. 10/100/1000BASE-TX, RJ45 connector
Video ...................................................................................... Intel Graphics Media Accelerator 950
Serial...................................................................................... 1 (RS232)
Parallel Port............................................................................ IEEE 1284 Type C connector (miniature) (adapter cable not included)
GPIB ....................................................................................... PCI-GPIB/TNT, micro D25 connector IEEE 488 and HS488 transfers
(adapter cable not included)
Hi-Speed USB ........................................................................
4
RAM ....................................................................................... 2 SO-DIMM sockets, DDR2 SDRAM, PC2 5400, dual channel
512 MB (1 x 512 DIMM) standard,
4 GB (2 x 2 GB DIMMs) maximum
Hard Drive
Base................................................................................... 60 GB minimum, internal 2.5 in., 9.5 mm Serial ATA 1.0 interface
Extended Temperature Option........................................... 30 GB minimum, internal 2.5 in., 9.5 mm Fast Ultra ATA100 interface
V (I/O) Keying......................................................................... Chassis V (I/O) = +5 VDC (blue key)
PXI Express Link Configurations
PXI Express 4-link configuration............................................ 3 x4 links and 1 x1 link
PXI Express 2-link configuration............................................ 2 x4 links
Power Requirements
Current (A)
Voltage (V)
Typical
Maximum
+3.3
+5
+5_STBY
+12
2
3.5
3
1
3.75
0
1.5
0.6
1.5
0
-12
Physical
Board dimensions .................................................................. 4-slot 3U PXI Express module
Slot requirements .................................................................. 1 system slot, 3 controller expansion slots
Compatibility.......................................................................... Fully compatible with PXI Express Specification 1.0
Weight.................................................................................... 0.97 kg (2.14 lb) typical
Environment
Maximum altitude.................................................................. 2,000 m (800 mbar) (at 25 °C ambient temperature)
Pollution degree.....................................................................
For indoor use only.
2
Operating Environment
Ambient temperature
Base............................................................................... 5 to 50 °C (tested in accordance with IEC-60068-2-1 and IEC-60068-2-2;
meets MIL-PRF-28800F Class 3 high temperature limit)
Extended temperature................................................... 0 to 55 °C (tested in accordance with IEC-60068-2-1 and IEC-60068-2-2;
meets MIL-PRF-28800F Class 3 low temperature limit and MIL-PRF-28800F Class 2
high temperature limit)
Relative humidity............................................................... 10 to 90% noncondensing (tested in accordance with IEC-60068-2-56)
BUY ONLINE at ni.com or CALL 800 813 3693 (U.S.)
4
2.0 GHz Dual-Core Embedded Controller for PXI Express
Storage Environment
Ambient temperature
Base............................................................................... -40 to 65 °C (tested in accordance with IEC-60068-2-1 and IEC-60068-2-2;
meets MIL-PRF-28800F Class 3 low temperature limit)
Extended temperature................................................... -40 to 71 °C (tested in accordance with IEC-60068-2-1 and IEC-60068-2-2;
meets MIL-PRF-28800F Class 3 limits)
Relative humidity............................................................... 5 to 95% noncondensing (tested in accordance with IEC-60068-2-56)
Shock and Vibration
Operational shock.................................................................. 30 g peak, half-sine, 11 ms pulse (tested in accordance with IEC-60068-2-27;
meets MIL-PRF-28800F Class 2 limits)
Random vibration
Operating........................................................................... 5 to 500 Hz, 0.3 grms (with solid-state hard drive)
Nonoperating..................................................................... 5 to 500 Hz, 2.4 grms (tested in accordance with IEC-60068-2-64;
nonoperating test profile exceeds the requirements of MIL-PRF-28800F, Class 3)
Note: Specifications subject to change without notice.
Safety Compliance
EN 61010-1, IEC 61010-1, UL 61010-01, CSA 61010-1
Electromagnetic Compatibility
Refer to the Declaration of Conformity (DoC) for regulatory compliance information.
To obtain the DoC for this product, click Declaration of Conformity at ni.com/certification.
BUY ONLINE at ni.com or CALL 800 813 3693 (U.S.)
5
NI Services and Support
NI has the services and support to meet
Local Sales and Technical Support
your needs around the globe and through
the application life cycle – from planning
and development through deployment
and ongoing maintenance. We offer
services and service levels to meet
customer requirements in research,
design, validation, and manufacturing.
Visit ni.com/services.
In offices worldwide, our staff is local to the country, giving you access
to engineers who speak your language. NI delivers industry-leading
technical support through online knowledge bases, our applications
engineers, and access to 14,000 measurement and automation
professionals within NI Developer Exchange forums. Find immediate
answers to your questions at ni.com/support.
We also offer service programs that provide automatic upgrades to
your application development environment and higher levels of technical
support. Visit ni.com/ssp.
Training and Certification
NI training is the fastest, most certain route to productivity with our
products. NI training can shorten your learning curve, save development
time, and reduce maintenance costs over the application life cycle. We
schedule instructor-led courses in cities worldwide, or we can hold a
course at your facility. We also offer a professional certification program
Hardware Services
NI Factory Installation Services
NI Factory Installation Services (FIS) is the fastest and easiest way to
use your PXI or PXI/SCXI combination systems right out of the box.
that identifies individuals who have high levels of skill and knowledge on Trained NI technicians install the software and hardware and configure
using NI products. Visit ni.com/training.
the system to your specifications. NI extends the standard warranty by
one year on hardware components (controllers, chassis, modules)
purchased with FIS. To use FIS, simply configure your system online
with ni.com/pxiadvisor.
Professional Services
Our NI Professional Services team is composed of NI applications
and systems engineers and a worldwide National Instruments Alliance
Partner program of more than 600 independent consultants and
integrators. Services range
Calibration Services
NI recognizes the need to maintain properly calibrated devices for
high-accuracy measurements. We provide manual calibration
procedures, services to recalibrate your products, and automated
calibration software specifically designed for use by metrology
laboratories. Visit ni.com/calibration.
from start-up assistance to
turnkey system integration.
Visit ni.com/alliance.
OEM Support
We offer design-in consulting and product integration assistance if you
want to use our products for OEM applications. For information about
special pricing and services for OEM customers, visit ni.com/oem.
Repair and Extended Warranty
NI provides complete repair services for our products. Express repair
and advance replacement services are also available. We offer
extended warranties to help you meet project life-cycle requirements.
Visit ni.com/services.
ni.com • 800 813 3693
*351391B-01*
351391B-01
2007-9289-501-101-D
National Instruments • info@ni.com
© 2007 National Instruments Corporation. All rights reserved. HS488, LabVIEW, National Instruments, National Instruments Alliance Partner, NI TestStand, NI, ni.com, and SCXI are
trademarks of National Instruments. Other product and company names listed are trademarks or trade names of their respective companies.
A National Instruments Alliance Partner is a business entity independent from NI and has no agency, partnership, or joint-venture relationship with NI.
相关型号:
©2020 ICPDF网 联系我们和版权申明