2.3 GHz Dual-Core Real-Time Embedded  
Controller for PXI Express  
NI PXIe-8130 RT NEW!  
• AMD Turion 64 X2 processor  
(2.3 GHz dual core)  
Development System  
Requirements (Windows)  
• LabVIEW  
• 1 GB (1 x 1 GB DIMM) dual-channel  
RAM standard  
• Extended temperature and 24/7  
operation mode, standard  
• Execution target for NI LabVIEW  
Real-Time or LabWindows/CVI  
Real-Time applications  
• Reliable and deterministic operation  
• Ethernet control of PXI  
• LabVIEW Real-Time Module  
• LabWindows/CVI  
(contact NI)  
Deployment Software (included)  
• LabVIEW Real-Time  
embedded software  
PXI System Configuration  
• Multicore enabled  
• Complete PXI system configuration  
• About 10 percent slower PID loop rates  
than PXI-8106 RT  
at ni.com/pxiadvisor  
• 82 kHz single PID loop rate, maximum  
Overview  
devices through CAN, GPIB, Ethernet, or serial protocols. And use  
NI-VISA to integrate third-party PXI/CompactPCI modules into  
your application.  
National Instruments RT Series PXI embedded controllers deliver a  
flexible, rugged platform for your deterministic, real-time measurement  
and control applications. The high-performance NI PXIe-8130 RT is the first  
National Instruments embedded controller based on PXI Express. You can  
develop your LabVIEW application with the LabVIEW Real-Time Module  
on Windows and download the program to your NI PXIe-8130 RT controller  
via Ethernet. The embedded code executes on a real-time OS. Thus, you  
use the powerful and flexible development tools of LabVIEW to build  
reliable, real-time solutions.  
In addition, the NI PXIe-8130 RT controller includes an external SMB  
connection for use as a trigger input, output, or watchdog timer. Use the  
external SMB to pass trigger and timing signals into and out of the PXI  
trigger bus in your system.  
Run Parallel Tasks on Separate Processor Cores  
The LabVIEW Real-Time Module takes advantage of the available dual  
cores on the AMD processor to increase performance and determinism  
for large real-time test and control applications. You can either explicitly  
assign certain tasks to run on specific cores of the processor or let the  
real-time operating system manage this assignment for you.  
LabVIEW Real-Time applications running on PXI systems achieve  
microsecond loop rates with only 3 to 4 ns of system jitter. These real-time  
measurement and control systems capitalize on the latest processors  
combined with the advanced timing, triggering, and I/O synchronization  
benefits of PXI. Furthermore, NI measurement services software extends  
the timing capabilities of PXI to deliver tight integration with LabVIEW  
Real-Time applications through operations such as hardware-timed  
software loops.  
AMD Turion 64 X2 Processor  
CPU  
(2.3 GHz Dual Core)  
Dual-channel 667 MHz DDR2 RAM, standard  
1 GB (1 x 1 GB)  
Dual-channel 667 MHz DDR2 RAM, maximum  
Storage, hard drive  
2 GB (2 x 1 GB)  
40 GB PATA1  
Storage, solid state  
Optional2  
PXI Express 4-link configuration  
10/100/1000BASE-TX (Gigabit) Ethernet  
GPIB (IEEE 488) controller  
Serial port (RS232)  
4 x 4 links  
Connect to Any I/O  
4
The modularity of PXI and open development environment of LabVIEW  
make it easy to integrate a variety of I/O within your application. Create  
a custom real-time embedded solution using an NI PXIe-8130 RT with  
any number and combination of PXI/CompactPCI plug-in modules.  
With built-in LabVIEW libraries, you can create applications with data  
acquisition, dynamic signal acquisition, motion control, image acquisition,  
reconfigurable I/O, and instrumentation. Communicate with peripheral  
Parallel port  
Hi-Speed USB ports  
ExpressCard/34 slot  
Watchdog/trigger SMB  
140 GB PATA hard drive for extended temperature and 24/7 operation.  
2Optional 512 or 128 MB solid-state drive can replace the hard drive.  
Table 1. NI PXIe-8130 RT Features  
2.3 GHz Dual-Core Real-Time Embedded Controllers for PXI Express  
Loop Rates (kHz)  
Extended Temperature and 24/7 Operation  
Benchmark  
Processing  
None  
Channels DAQ I/O Mode NI PXIe-8130 NI PXI-8106  
An NI 8130 embedded controller comes standard with the extended  
temperature and 24/7 operation mode. It uses a rugged hard drive  
designed for both reliability in low- and high-temperature extremes  
and continuous operation. An NI 8130 has an operating temperature  
of 0 to 55 °C and a storage temperature of -40 to 71 °C.  
1
1
1
1
1
16  
16  
16  
16  
16  
Polling  
Polling  
Interrupt  
Interrupt  
Interrupt  
Polling  
82.0  
74.6  
34.7  
66.9  
72.2  
24.4  
22.5  
26.4  
25.1  
22.0  
86.6  
85.5  
37.5  
76.9  
67.3  
28.9  
26.4  
15.7  
28.2  
25.3  
PID  
PID  
Local Logging  
Host Communication  
None  
Analog Input  
and Output  
PID  
PID  
Polling  
You can also use the NI PXIe-8130 RT for applications that require  
continuous operation for up to 24 hours/day, seven days/week because the  
hard drive is rated for such operation. Standard hard drives are designed  
to be powered on for eight hours/day, five days/week. The hard drive used  
in the NI PXIe-8130 RT controller is rated for continuous operation and  
exposure to high duty cycles (the percentage of the maximum sustained  
throughput of the hard drive). This makes the controller suitable for a large  
variety of applications and deployment conditions.  
Interrupt  
Interrupt  
Interrupt  
Local Logging  
Host Communication  
Table 2. Maximum loop rates for LabVIEW Real-Time PXI/PXI Express systems are  
shown. (All benchmarks use LabVIEW 8.5 Real-Time Module with NI-DAQmx 8.5.  
Processors for both the controllers were used in the dual-core mode. Benchmarks were  
revised to adhere to the architecture recommended by NI for symmetric multiprocessing-  
enabled systems. Benchmarks that do not test network performance run on a headless  
target without a direct Ethernet connection for maximum performance. Benchmarks  
that do test network performance use interrupt-mode Ethernet via a direct connection  
between the host PC and real-time target with a crossover cable.) Visit ni.com or  
contact National Instruments for additional benchmarks.  
Create Reliable Stand-Alone Systems  
To ensure reliable operation, embedded LabVIEW applications continue  
to run even if the host PC is interrupted or rebooted. Because the  
NI PXIe-8130 RT embedded controller runs in a separate chassis with  
a dedicated power supply, you can shut down the host computer  
entirely without disrupting the real-time program.  
Ordering Information  
For stand-alone operation, you can embed code in the system so  
that it starts automatically when the system boots, requiring no human  
interaction. Use the LabVIEW Professional Development System and  
LabVIEW Real-Time Module to compile your LabVIEW application into  
an executable and download it to your NI PXIe-8130 RT controller.  
To order a complete PXI system based on a LabVIEW Real-Time  
embedded controller, visit ni.com/pxiadvisor.  
Controller Model  
NI PXIe-8130 RT  
Extended Temperature and 24/7 Operation (standard) ........780032-33  
Dual-Boot Option  
Memory Upgrades  
You can configure NI PXI embedded controllers to boot into Windows  
or the LabVIEW Real-Time OS. NI Measurement & Automation Explorer  
(MAX) includes features for installing and configuring PXI embedded  
controllers as LabVIEW Real-Time targets. The controllers use a  
hardware switch or BIOS setting to boot into the desired OS.  
The result is a PXI embedded controller that can run embedded  
LabVIEW Real-Time or Windows applications. When the controller is in  
real-time mode, you need another Windows computer to develop and  
debug the LabVIEW Real-Time code for the PXI controller. To enable a  
Windows PXI embedded controller to dual-boot with the real-time OS,  
you must purchase the LabVIEW Real-Time embedded deployment  
software for the controller.  
Standard: 1 GB (1 x 1 GB DIMM)  
Recommended upgraded memory configurations:  
2 GB (1 x 1 GB DIMM must be purchased)  
1 GB DDR2 DIMM RAM................................................780031-1024  
Select Solid-State Storage Options  
Solid-state HDD, 128 M......................................................779175-128  
Solid-state HDD, 512 M......................................................779175-512  
Select Accessories  
Micro-GPIB to GPIB cable, 0.2 m ......................................183285-0R2  
Micro-GPIB to GPIB cable, 1 m ............................................183285-01  
Micro-GPIB to GPIB cable, 2 m ............................................183285-02  
NI PXI-8252 IEEE 1394 interface module..............................778925-01  
BUY NOW!  
For complete product specifications, pricing, and accessory  
information, call 800 813 3693 (U.S.) or go to ni.com/pxi.  
BUY ONLINE at ni.com or CALL 800 813 3693 (U.S.)  
2
2.3 GHz Dual-Core Real-Time Embedded Controllers for PXI Express  
Operating Environment  
Ambient temperature range ............... 0 to 55 °C (tested in accordance  
Specifications  
Specifications subject to change without notice.  
with IEC-60068-2-1 and  
IEC-60068-2-2; meets  
Features  
Processor............................................. AMD 2.3 GHz Turion 64 X2  
Chipset ................................................ nVIDIA MCP55 Pro  
System Memory (RAM)....................... 1 GB dual-channel DDR2 RAM  
PC2 5300 (standard)  
MIL-PRF-28800F Class 3  
low-temperature limit and  
MIL-PRF-28800F Class 2  
high-temperature limit)  
2 GB dual-channel DDR2 RAM  
PC2 5300 (maximum)  
Relative humidity range...................... 10 to 90%, noncondensing  
(tested in accordance with  
Ethernet............................................... 10/100/1000BASE-TX,  
RJ45 connector  
Hard Drive  
Extended Temperature and  
24/7 Operation................................ 40 GB minimum, internal  
2.5 in., 9.5 mm Fast Ultra  
ATA100 interface  
Video ................................................... ATI Radeon X300  
Embedded GPU  
Serial................................................... 1 (RS232)  
Parallel ................................................ IEEE 1284 Type C miniature  
connector (adapter cable  
IEC-60068-2-56)  
Storage Environment  
Ambient temperature range ............... -40 to 71 °C (tested in  
accordance with IEC-60068-2-1  
and IEC-60068-2-2; meets  
MIL-PRF-28800F Class 3 limits)  
Relative humidity range...................... 5 to 95% noncondensing  
(tested in accordance with  
IEC-60068-2-56)  
Shock and Vibration  
Operating shock .................................. 30 g peak, half-sine, 11 ms  
not included)  
pulse (tested in accordance  
with IEC-60068-2-27; meets  
MIL-PRF-28800F Class 2 limits)  
GPIB .................................................... PCI-GPIB/TNT, micro D25  
connector IEEE 488 and  
HS488 transfers  
Random vibration  
Hi-Speed USB .....................................  
4
Operating ........................................ 5 to 500 Hz, 0.3 grms  
(with solid-state hard drive)  
Nonoperating.................................. 5 to 500 Hz, 2.4 grms (tested in  
accordance with IEC-60068-2-64;  
PXI Express Link Configurations  
PXI Express 4-link configuration......... 4 x4 links  
Power Requirements  
nonoperating test profile  
exceeds the requirements of  
Current (A)  
MIL-PRF-28800F, Class 3)  
Voltage (V)  
+3.3 V  
+5 V  
+12 V  
-12 V  
Typical  
1.80  
3.50  
2.75  
0.00  
Maximum  
3.90  
4.70  
4.00  
0.00  
Safety Compliance  
• IEC 61010-1, EN 61010-1  
• UL 61010-01, CSA 61010-1  
+5 VAux  
0.35  
0.70  
Electromagnetic Compatibility  
• EN 61326 EMC requirements; Minimum Immunity  
Physical  
Board dimensions ............................... 4-slot 3U PXI Express module  
Slot requirements ............................... 1 system slot plus 3  
controller expansion slots  
Compatibility....................................... Fully compatible with PXI  
Express Specification 1.0  
• EN 55011 Emissions; Group 1, Class A  
• CE, C-Tick, ICES, and FCC Part 15 Emissions; Class A  
CE Compliance  
This product meets the essential requirements of applicable European  
Directives, as amended for CE marking, as follows:  
Weight................................................. 0.98 kg (2.15 lb) typical  
• 2006/95/EC; Low-Voltage Directive (safety)  
• 2004/108/EC; Electromagnetic Compatibility Directive (EMC)  
Environment  
Maximum altitude............................... 2,000 m (800 mbar)  
Refer to the Declaration of Conformity (DoC) for this product for any  
additional regulatory compliance information. To obtain the DoC for this  
product, visit ni.com/certification, search by model number or product  
line, and click the appropriate link in the Certification column.  
(at 25 °C ambient temperature)  
2
Pollution degree..................................  
For indoor use only.  
BUY ONLINE at ni.com or CALL 800 813 3693 (U.S.)  
3
NI Services and Support  
NI has the services and support to meet  
Local Sales and Technical Support  
your needs around the globe and through  
the application life cycle – from planning  
and development through deployment  
and ongoing maintenance. We offer  
services and service levels to meet  
customer requirements in research,  
design, validation, and manufacturing.  
Visit ni.com/services.  
In offices worldwide, our staff is local to the country, giving you access  
to engineers who speak your language. NI delivers industry-leading  
technical support through online knowledge bases, our applications  
engineers, and access to 14,000 measurement and automation  
professionals within NI Developer Exchange forums. Find immediate  
answers to your questions at ni.com/support.  
SERVICE  
NEEDS  
We also offer service programs that provide automatic upgrades to  
your application development environment and higher levels of technical  
support. Visit ni.com/ssp.  
Training and Certification  
NI training is the fastest, most certain route to productivity with our  
products. NI training can shorten your learning curve, save development  
time, and reduce maintenance costs over the application life cycle. We  
schedule instructor-led courses in cities worldwide, or we can hold a  
course at your facility. We also offer a professional certification program  
that identifies individuals who have high levels of skill and knowledge  
on using NI products. Visit ni.com/training.  
Hardware Services  
NI Factory Installation Services  
NI Factory Installation Services (FIS) is the fastest and easiest way to  
use your PXI or PXI/SCXI combination systems right out of the box.  
Trained NI technicians install the software and hardware and configure  
the system to your specifications. NI extends the standard warranty  
by one year on hardware components (controllers, chassis, modules)  
purchased with FIS. To use FIS, simply configure your system online  
with ni.com/pxiadvisor.  
Professional Services  
Our NI Professional Services team is composed of NI applications  
and systems engineers and a worldwide National Instruments Alliance  
Partner program of more than 600 independent consultants and  
integrators. Services range  
Calibration Services  
NI recognizes the need to maintain properly calibrated devices for  
high-accuracy measurements. We provide manual calibration procedures,  
services to recalibrate your products, and automated calibration software  
specifically designed for use by metrology laboratories. Visit  
ni.com/calibration.  
from start-up assistance to  
turnkey system integration.  
Visit ni.com/alliance.  
OEM Support  
We offer design-in consulting and product integration assistance if you  
want to use our products for OEM applications. For information about  
special pricing and services for OEM customers, visit ni.com/oem.  
Repair and Extended Warranty  
NI provides complete repair services for our products. Express repair  
and advance replacement services are also available. We offer  
extended warranties to help you meet project life-cycle requirements.  
Visit ni.com/services.  
ni.com • 800 813 3693  
*351508C-01*  
351508C-01  
2008-9745-501-101-D  
National Instruments • info@ni.com  
©2008 National Instruments. All rights reserved. CVI, HS488, LabVIEW, National Instruments, National Instruments Alliance Partner, NI, ni.com, and SCXI are trademarks of National Instruments.  
The mark LabWindows is used under a license from Microsoft Corporation. Windows is a registered trademark of Microsoft Corporation in the United States and other countries. Other product  
and company names listed are trademarks or trade names of their respective companies. A National Instruments Alliance Partner is a business entity independent from National Instruments and  
has no agency, partnership, or joint-venture relationship with National Instruments.  

相关型号:

NIPXIE-8234

Image Acquisition from GigE Vision Cameras
NI

NIPXIE-8360

PCI Express control of PXI Express/CompactPCI Express
NI

NIPXIE-8370

PCI Express control of PXI Express/CompactPCI Express
NI

NIPXIE-PCIE8361

PCI Express control of PXI Express/CompactPCI Express
NI

NIPXIE-PCIE8362

PCI Express control of PXI Express/CompactPCI Express
NI

NIPXIE-PCIE8371

PCI Express control of PXI Express/CompactPCI Express
NI

NIPXIE-PCIE8372

PCI Express control of PXI Express/CompactPCI Express
NI

NIPXIE4331

Data Acquisition with Integrated Signal Conditioning for Bridge-Based Measurements
NI

NIPXIe5162

1.5 GHz analog Sampling rates of 5 GS/s
NI

NIPXIe5185

1.5 GHz analog Sampling rates of 5 GS/s
NI

NIPXIe5186

1.5 GHz analog Sampling rates of 5 GS/s
NI

NIPXIE7961R

16-Channel, 50 MS/s, 14-Bit Digitizer Adapter Module for NI FlexRIO
NI