NIPXIE-8130 [NI]
High-Bandwidth, 2.3 GHz Dual-Core Embedded Controller for PXI Express; 高带宽, 2.3 GHz的双核嵌入式控制器PXI Express的型号: | NIPXIE-8130 |
厂家: | National Instruments |
描述: | High-Bandwidth, 2.3 GHz Dual-Core Embedded Controller for PXI Express |
文件: | 总6页 (文件大小:302K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
High-Bandwidth, 2.3 GHz Dual-Core
Embedded Controller for PXI Express
NI PXIe-8130 NEW!
• AMD Turion 64 X2 processor
(2.3 GHz dual core)
Software
• OS and drivers already installed
• Up to 4 GB/s system bandwidth,
up to 1 GB/s slot bandwidth
• 1 GB (1 x 1 GB DIMM) dual-channel
667 MHz DDR2 RAM standard,
• Hard-drive-based recovery image
PXI System Configuration
• Complete PXI system configuration
at ni.com/pxiadvisor
2 GB (2 x 1 GB DIMMs) maximum
• 10/100/1000BaseTX Ethernet
• 4 Hi-Speed USB ports
• ExpressCard/34 slot
• DVI-I video connector
• GPIB (IEEE 488) controller
• RS232 serial port
• IEEE 1284 ECP/EPP parallel port
• Integrated hard drive
• Internal PXI trigger bus routing
• Watchdog timer
such as Windows XP, where multiple applications run simultaneously.
Two applications, such as National Instruments LabVIEW and Microsoft
Excel, can each execute on a separate core at the same time, which
improves overall system performance. Multithreaded applications, such
as NI LabVIEW, take full advantage of dual-core processors because they
automatically separate their tasks into independent threads. A dual-core
processor can simultaneously execute two of these threads.
Overview
The National Instruments PXIe-8130 is a high-performance AMD Turion
64 X2 processor-based embedded controller for use in PXI Express
systems. With the 2.3 GHz dual-core processor, dual-channel 667 MHz
DDR2 memory, the NI PXIe-8130 is ideal for modular instrumentation and
data acquisition applications.
AMD Turion 64 X2 Processor
CPU
(2.3 GHz Dual Core)
High Bandwidth
L2 cache
512 KB x 2 (512 KB per core)
System bandwidth
Slot bandwidth
Up to 4 GB/s
Up to 1 GB/s
4 x4 links
1 GB (1 x 1 GB)
2 GB (2 x 1 GB)
60 GB SATA1
The NI PXIe-8130 features an NVIDIA MCP55 Pro chipset.
This chipset provides four x4 (“by four”) PCI Express lanes that are
forwarded to the PXI chassis backplane to create four x4 PXI Express
slots. Each of these slots has up to 1 GB/s of dedicated bandwidth
with the overall system bandwidth of up to 4 GB/s.
PXI Express 4-link configuration
Dual-channel 667 MHz DDR2 RAM, standard
Dual-channel 667 MHz DDR2 RAM, maximum
Hard drive, minimum
10/100/1000BaseTX (Gigabit) Ethernet
GPIB (IEEE 488) controller
Serial port (RS232)
ꢀ
ꢀ
ꢀ
Parallel port
ꢀ
Hi-Speed USB ports
ꢀ
ExpressCard/34 slot
ꢀ
Watchdog/trigger SMB
Installed OS
ꢀ
Windows XP Professional2
140 GB PATA hard drive for extended temperature, 24/7 operation option.
2Contact National Instruments or visit ni.com/pxiadvisor for information on other available operating systems.
Table 1. NI PXIe-8130 Features
Dual-Core Processor
Figure 1. This NI PXIe-8130 controls an 8-slot PXI Express modular instrument and
data acquisition system.
The NI PXIe-8130 includes the dual-core AMD Turion 64 X2 processor.
Dual-core processors contain two cores, or computing engines, in one
physical package. Dual-core processors can simultaneously execute two
computing tasks, which is advantageous in multitasking environments,
High-Bandwidth, 2.3 GHz Dual-Core Embedded Controller for PXI Express
Hardware
Video
With state-of-the-art packaging, the NI PXIe-8130 integrates the
AMD Turion 64 X2 processor and all standard and extended PC I/O ports
into a single unit. By integrating many I/O ports on the controller, all
active slots in the chassis remain available for measurement and control
modules. This rugged modular design minimizes integration issues and
eliminates the need for complex cabling to daughter boards. The
NI PXIe-8130 block diagram is shown in Figure 2.
The NI PXIe-8130 includes an integrated ATI Radeon X300 graphics
processing unit, which delivers intense, realistic 3D graphics with sharp
images, fast rendering, smooth motion, and high detail, without the need
for an additional video card or peripheral. This unique architecture provides
balanced memory usage between graphics and the system for optimal
performance. Additionally, the NI PXIe-8130 features a DVI-I video
connector, compatible with digital (DVI) and analog (VGA) monitors. A DVI-I
to VGA adapter is included with the controller for use with VGA monitors.
Memory
The NI PXIe-8130 uses dual-channel 667 MHz DDR2 SDRAM, which
makes the controller ideal for data-intensive applications requiring
significant analysis. The NI PXIe-8130 has two SO-DIMM sockets for
the DDR2 SDRAM. 1 GB (1 x 1 GB DIMM) of RAM is standard with
upgrade options to 2 GB.
Extended Temperature and
24/7 Operation Option
The NI PXIe-8130 embedded controller is available in two versions
to address different environmental and usage conditions. The primary
difference is that the version for extended temperature and 24/7
operation uses a different hard drive, designed for both reliability in
low- and high-temperature extremes and 24/7 operation. The standard
version of the controllers has an operating temperature of 5 to 50 °C
and a storage temperature of -40 to 65 °C. The extended temperature
and 24/7 operation version has an operating temperature of 0 to 55 °C
and a storage temperature of -40 to 71 °C.
Figure 2. NI PXIe-8130 Block Diagram
Peripheral I/O
The NI PXIe-8130 includes high-performance peripheral I/O such as
10/100/1000BaseTX (Gigabit) Ethernet and four Hi-Speed USB ports
for connection to a keyboard, a mouse, a CD-ROM/DVD-ROM drive
for software installation, or other standard PC peripherals such as
speakers, printers, or memory sticks. Use the IEEE 1284 ECP/EPP
parallel port to connect to a wide variety of devices, including tape
backup drives, printers, and scanners. An RS232 port is available for
connecting to serial devices. Additionally, the NI PXIe-8130 controller
includes an integrated GPIB (IEEE 488) controller, which provides control
of external instrumentation, saving additional cost and a slot.
You can also use the extended temperature and 24/7 operation
version for applications that require continuous operation for up to
24 hours/day, seven days/week because the hard drive is rated for
24/7 operation. The hard drive in the standard version of the controllers
is designed to be powered on for eight hours/day, five days/week.
Additionally, 24/7 operation applications may subject the hard drive
to a high duty cycle (the percentage of the maximum sustained
ExpressCard
The NI PXIe-8130 features an ExpressCard/34 slot. ExpressCard uses the
PCI Express and Hi-Speed USB serial interfaces to provide up to 2.5 Gb/s throughput of the hard drive). The hard drive in the standard version
of bidirectional throughput. Use the ExpressCard/34 slot to add a second
Gigabit Ethernet port to your system or additional peripheral I/O such as
external hard drives, RAID arrays, 802.11 wireless LAN, IEEE 1394,
Bluetooth, or various memory adapters.
of the controllers is designed for a 20 percent duty cycle. The hard
drive in the extended temperature and 24/7 operation version has a
capacity of 40 GB (minimum) versus the 60 GB (minimum) hard drive
used in the standard version of the controllers. See specifications for
further details.
BUY ONLINE at ni.com or CALL 800 813 3693 (U.S.)
2
High-Bandwidth, 2.3 GHz Dual-Core Embedded Controller for PXI Express
development experience with your PXI system out of the box. To configure
Software
a complete PXI system with FIS, contact National Instruments or visit
The NI PXIe-8130 comes with the following minimum set of software
already installed:
ni.com/pxiadvisor.
• Microsoft Windows XP Professional OS (contact National Instruments USB Peripherals
or visit ni.com/pxiadvisor for localized versions of Windows XP and
National Instruments offers a USB-to-dual-PS/2 keyboard/mouse adapter
for other available operating systems)
cable to connect a legacy PS/2 keyboard and mouse to a single USB port
on your embedded controller. Additionally, NI offers external USB CD-ROM/
DVD-ROM and USB floppy drives for use with your embedded controller.
Connect these drives to your embedded controller for easy software
installation and upgrades. Both are completely powered through the
USB ports, so no external power connections are required. Additional
USB peripherals, such as USB speakers to add audio or USB memory
sticks to add easily removable memory, are widely available from PC
peripheral manufacturers.
• Hard-drive-based recovery image
• NI-VISA and NI-488.2 drivers
• Drivers for all built-in I/O ports (Table 1)
With NI Factory Installation Services (FIS) added to a PXI system order,
your embedded controller is shipped already configured with all software
and drivers applicable for your system. For example, assume you order
a PXI system that includes LabVIEW and NI TestStand software, as well
as data acquisition modules, a digitizer, an arbitrary waveform generator,
and a digital multimeter (DMM). With FIS, NI not only assembles and
tests your system, but also fully configures the embedded controller with Additional Peripheral I/O
the appropriate NI-DAQmx, NI-SCOPE, NI-FGEN, and NI-DMM drivers,
With National Instruments FIS, you receive complete system-level
as well as LabVIEW and NI TestStand.
assembly and functional testing of the PXI chassis, controller, and
all peripheral devices, as well as installation of all device drivers and
software programs (such as NI LabVIEW). For online configuration of
a complete PXI system, including information about FIS, visit the PXI
Advisor at ni.com/advisor.
Additionally, your embedded controller is configured with a customized
hard-drive-based recovery image, so you can restore your controller to
the as-shipped configuration at any time. This combination of software
configuration and recovery tools provides both a productive and reliable
40 GB (or greater) 2.5 in. PATA Ext Temp,
Ordering Information
24/7 Blank HDD Spare/Replacement ..............................779175-02
USB-to-dual-PS/2 keyboard/mouse adapter cable ..............778713-02
External USB CD-ROM/DVD-ROM drive ..............................778492-01
External USB floppy drive......................................................778492-02
USB English keyboard and optical mouse ............................779660-01
Parallel port adapter cable (6 in.)..........................................777169-01
Micro-GPIB to GPIB adapter cable (0.2 m) ........................183285-0R2
Micro-GPIB to GPIB cable (1 m) ............................................183285-01
Micro-GPIB to GPIB cable (2 m) ............................................183285-02
ExpressCard strain-relief accessory
For online configuration of a complete PXI system, including Factory
Installation Services, visit ni.com/pxiadvisor.
Step 1. Controller Model – select one of the following.
NI PXIe-8130
Base ..................................................................................780031-xx
Extended Temperature and 24/7 Operation......................780032-xx
Step 2. Replace “xx” to select installed OS.
Windows XP Professional (English)1 ..................................................01
1Contact National Instruments or visit ni.com/pxiadvisor for the latest
operating systems.
for embedded controllers..................................................192524-01
NI MKD-1117 (rack-mount 1U LCD monitor,
keyboard, mouse drawer)..................................................779872-01
NI FPM-1017 (17 in. flat panel monitor) ..............................779559-01
NI FPT-1015 (flat panel touch screen with
VGA interface and USB) ..................................................779560-01
2For additional peripheral I/O modules, including serial, IEEE 1394, and SCSI, visit
ni.com/pxiadvisor.
Step 3. Memory upgrades – select the amount of upgrade memory.
Standard:
1 GB (1 x 1 GB DIMM)
Recommended upgraded memory configurations:
2 GB (1 x 1 GB DIMM must be purchased)
1 GB DDR2 RAM ..........................................................780031-1024
Step 4. Accessories2
60 GB (or greater) 2.5 in. SATA Blank
BUY NOW!
For complete product specifications, pricing, and accessory
information, call 800 813 3693 (U.S.) or go to ni.com/pxi.
HDD Spare/Replacement..................................................779175-03
BUY ONLINE at ni.com or CALL 800 813 3693 (U.S.)
3
High-Bandwidth, 2.3 GHz Dual-Core Embedded Controller for PXI Express
Operating Environment
Ambient temperature range
Specifications
Specifications subject to change without notice.
Base ................................................ 5 to 50 °C (tested in accordance
with IEC-60068-2-1 and IEC-
Features
Processor............................................. AMD 2.3 GHz Turion 64 X2
Chipset ................................................ NVIDIA MCP55 Pro
System Memory (RAM)....................... 1 GB dual-channel DDR2 RAM
PC2 5300 (standard)
60068-2-2; meets
MIL-PRF-28800F Class 3 high-
temperature limit)
Extended temperature range.......... 0 to 55 °C (tested in accordance
with IEC-60068-2-1 and
2 GB dual-channel DDR2 RAM
PC2 5300 (maximum)
IEC-60068-2-2; meets
Ethernet............................................... 10/100/1000BaseTX,
RJ45 connector
MIL-PRF-28800F Class 3 low-
temperature limit and
Hard Drive
MIL-PRF-28800F Class 2 high-
temperature limit)
Relative humidity range...................... 10 to 90%, noncondensing
(tested in accordance with
Base ................................................ 60 GB minimum, internal 2.5 in.,
9.5 mm Serial ATA 1.0 interface
Extended Temperature and
24/7 Operation Option.................... 40 GB minimum, internal
2.5 in., 9.5 mm Fast Ultra
ATA100 interface
Video ................................................... ATI Radeon X300
Embedded GPU
Serial................................................... 1 (RS232)
Parallel ................................................ IEEE 1284 Type C miniature
connector (adapter cable
IEC-60068-2-56)
Storage Environment
Ambient temperature range
Base ................................................ 40 to 65 °C (tested in
accordance with IEC-60068-2-1
and IEC-60068-2-2; meets
MIL-PRF-28800F Class 3 low-
temperature limit)
Extended temperature range.......... -40 to 71 °C (tested in
accordance with IEC-60068-2-1
and IEC-60068-2-2; meets
not included)
GPIB .................................................... PCI-GPIB/TNT, micro D25
connector IEEE 488 and
HS488 transfers
MIL-PRF-28800F Class 3 limits)
Relative humidity range...................... 5 to 95% noncondensing
(tested in accordance with
Hi-Speed USB .....................................
4
PXI Express Link Configurations
PXI Express 4-link configuration......... 4 x4 links
IEC-60068-2-56)
Current (A)
Shock and Vibration
Operating shock .................................. 30 g peak, half-sine, 11 ms
Voltage (V)
+3.3 V
+5 V
Typical
1.80
3.50
Maximum
3.90
pulse (tested in accordance
4.70
+12 V
-12 V
+5 VAux
2.75
0.00
0.35
4.00
0.00
0.70
with IEC-60068-2-27; meets
MIL-PRF-28800F Class 2 limits)
Random vibration
Operating ........................................ 5 to 500 Hz, 0.3 grms
(with solid-state hard drive)
Nonoperating.................................. 5 to 500 Hz, 2.4 grms (tested in
accordance with IEC-60068-2-64;
Physical
Board dimensions ............................... 4-slot 3U PXI Express module
Slot requirements ............................... One system slot plus three
controller expansion slots
Compatibility....................................... Fully compatible with PXI
Express Specification 1.0
nonoperating test profile
exceeds the requirements of
MIL-PRF-28800F, Class 3)
Weight................................................. 0.98 kg (2.15 lb) typical
Safety Compliance
• IEC 61010-1, EN 61010-1
• UL 61010-01, CSA 61010-1
Environment
Maximum altitude............................... 2,000 m (800 mbar)
(at 25 °C ambient temperature)
Electromagnetic Compatibility
• EN 61326 EMC requirements; Minimum Immunity
Pollution degree..................................
For indoor use only.
2
• EN 55011 Emissions; Group 1, Class A
• CE, C-Tick, ICES, and FCC Part 15 Emissions; Class A
BUY ONLINE at ni.com or CALL 800 813 3693 (U.S.)
4
High-Bandwidth, 2.3 GHz Dual-Core Embedded Controller for PXI Express
CE Compliance
This product meets the essential requirements of applicable European
Directives, as amended for CE marking, as follows:
• 73/23/EEC; Low-Voltage Directive (safety)
• 89/336/EEC; Electromagnetic Compatibility Directive (EMC)
Refer to the Declaration of Conformity (DoC) for this product for any
additional regulatory compliance information. To obtain the DoC for
this product, visit ni.com/certification, search by model number or
product line, and click the appropriate link in the Certification column.
Waste Electrical and Electronic Equipment (WEEE)
EU Customers: At the end of their life cycle, all products must be sent
to a WEEE recycling center. For more information about WEEE recycling
centers and National Instruments WEEE initiatives, visit
ni.com/environment/weee.htm.
BUY ONLINE at ni.com or CALL 800 813 3693 (U.S.)
5
NI Services and Support
NI has the services and support to meet
Local Sales and Technical Support
your needs around the globe and through
the application life cycle – from planning
and development through deployment
and ongoing maintenance. We offer
services and service levels to meet
customer requirements in research,
design, validation, and manufacturing.
Visit ni.com/services.
In offices worldwide, our staff is local to the country, giving you access
to engineers who speak your language. NI delivers industry-leading
technical support through online knowledge bases, our applications
engineers, and access to 14,000 measurement and automation
professionals within NI Developer Exchange forums. Find immediate
answers to your questions at ni.com/support.
We also offer service programs that provide automatic upgrades to
your application development environment and higher levels of technical
support. Visit ni.com/ssp.
Training and Certification
NI training is the fastest, most certain route to productivity with our
products. NI training can shorten your learning curve, save development
time, and reduce maintenance costs over the application life cycle. We
schedule instructor-led courses in cities worldwide, or we can hold a
course at your facility. We also offer a professional certification program
Hardware Services
NI Factory Installation Services
NI Factory Installation Services (FIS) is the fastest and easiest way to
use your PXI or PXI/SCXI combination systems right out of the box.
that identifies individuals who have high levels of skill and knowledge on Trained NI technicians install the software and hardware and configure
using NI products. Visit ni.com/training.
the system to your specifications. NI extends the standard warranty by
one year on hardware components (controllers, chassis, modules)
purchased with FIS. To use FIS, simply configure your system online
with ni.com/pxiadvisor.
Professional Services
Our NI Professional Services team is composed of NI applications
and systems engineers and a worldwide National Instruments Alliance
Partner program of more than 600 independent consultants and
integrators. Services range
Calibration Services
NI recognizes the need to maintain properly calibrated devices for
high-accuracy measurements. We provide manual calibration
procedures, services to recalibrate your products, and automated
calibration software specifically designed for use by metrology
laboratories. Visit ni.com/calibration.
from start-up assistance to
turnkey system integration.
Visit ni.com/alliance.
OEM Support
We offer design-in consulting and product integration assistance if you
want to use our products for OEM applications. For information about
special pricing and services for OEM customers, visit ni.com/oem.
Repair and Extended Warranty
NI provides complete repair services for our products. Express repair
and advance replacement services are also available. We offer
extended warranties to help you meet project life-cycle requirements.
Visit ni.com/services.
ni.com • 800 813 3693
*351505A-01*
351505A-01
2007-8951-501-101-D
National Instruments • info@ni.com
© 2007 National Instruments Corporation. All rights reserved. HS488, LabVIEW, National Instruments, National Instruments Alliance Partner, NI, ni.com, and
SCXI are trademarks of National Instruments. Other product and company names listed are trademarks or trade names of their respective companies.
A National Instruments Alliance Partner is a business entity independent from NI and has no agency, partnership, or joint-venture relationship with NI.
相关型号:
©2020 ICPDF网 联系我们和版权申明