Current Transducers HTB 50 .. 400-P/SP5  
and HTB 50 .. 100-TP/SP5  
IPN = 50 .. 400 A  
For the electronic measurement of currents: DC, AC, pulsed, mixed,  
with a galvanic isolation between the primary circuit (high power) and  
the secondary circuit (electronic circuit).  
Electrical data  
Primarynominal  
r.m.s. current  
IPN (A)  
Primary current  
measuring range  
IP (A)  
Type  
50  
±150  
HTB 50-P/SP5, HTB 50-TP/SP51)  
100  
200  
300  
400  
±300  
±500  
±600  
±600  
HTB 100-P/SP5, HTB 100-TP/SP51)  
HTB 200-P/SP5  
HTB 300-P/SP5  
HTB 400-P/SP5  
Features  
· Hall effect measuring principle  
· Galvanic isolation between primary  
and secondary circuit  
· Isolationvoltage2500V  
· Low power consumption  
VC  
IC  
Vd  
RIS  
VOUT  
ROUT  
RL  
Supplyvoltage(±5%)2)  
Currentconsumption  
R.m.s. voltage for AC isolation test, 50/60 Hz, 1 mn  
Isolationresistance@500VDC  
Output voltage @ ± IPN, RL = 10 kW, TA = 25°C  
Outputinternalresistance  
+12 .. +15  
<15  
2.5  
>500  
VOE ±1.667  
100  
V
mA  
kV  
MW  
V
· Primary bus bar option for 50A and  
100A version for ease of connection  
W
kW  
Loadresistance  
³ 10  
SpecialFeatures  
Accuracy - Dynamic performance data  
· Single power supply from 12V to 15V  
X
Accuracy @ IPN, TA = 25°C (without offset)  
<±1  
% of IPN  
e
Linearity (0 .. ± IPN)  
<±1  
Vc/2±30  
% of IPN  
VOLE  
VOH  
Electrical offset voltage, TA = 25°C  
Hysteresis offset voltage @ IP = 0;  
after an excursion of 3 x IPN  
mV  
Advantages  
<±0.5 % of IPN  
· Small size and space saving  
· Only one design for wide current  
ratings range  
· High immunity to external  
interference.  
VOT  
Thermal drift of VOE  
HTB 50-(T)P/SP5  
HTB 100-(T)P..400-P/SP5 <±0.5  
<±1.0  
mV/K  
mV/K  
%/K  
ms  
TCe  
Thermal drift (% of reading)  
Response time @ 90% of IP  
Frequencybandwidth(-3dB)3)  
<±0.05  
<3  
DC .. 50 kHz  
G
tr  
f
General data  
Applications  
TA  
TS  
m
Ambientoperatingtemperature  
Ambientstoragetemperature  
Mass (-TP version)  
-25 .. +85  
-25 .. +85  
<30 (<36)  
°C  
°C  
g
· AC variable speed drives  
· Static converters for DC motor drives  
· Battery supplied applications  
· Uninterruptible Power Supplies  
(UPS)  
· Switched Mode Power Supplies  
(SMPS)  
· Power supplies for welding  
applications.  
Notes : EN 50178 approval pending  
1) -TP version is equipped with a primary bus bar.  
2) Operating at +12V £ Vc < +15V will reduce measuring range.  
3) Derating is needed to avoid excessive core heating at high frequency.  
030221/0  
LEM Components  
www.lem.com  
HTB 50 ... 400-P/SP5  
Left view  
Back view  
Positive Current Flow  
39  
14 MAX.  
2 1  
3
4-0.635x0.635  
3
24.5  
5.5  
Secondary Pin Identification  
2-P=2.5  
2-d2  
Mounting Pins  
1 +Vc  
2 0V  
3 Output  
3
10  
19  
Bottom View  
HTB 50 ... 100-TP/SP5  
39  
Left view  
14 MAX.  
Back view  
32 1  
1.5  
1.5  
1.5  
-0.635x0.635  
3
10  
3
Positive Current Flow  
10.5  
2-P=2.5  
9
3
Secondary Pin Identification  
6-1.5x1.5  
3.25  
1 +Vc  
2 0V  
3 Output  
3
Bottom view  
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without previous notice.  

相关型号:

HTB100-P_07

Current Transducers
LEM

HTB100-SP5

Current Transducers
LEM

HTB100-SP51

Current Transducers
LEM

HTB100-TP

Current Transducers HTB 50~400-P and HTB 50~100-TP
LEM

HTB100-TP/SP5

Current Transducers HTB 50~400-P/SP5 and HTB 50~100-TP/SP5
LEM

HTB100-TP1

Current Transducers
LEM

HTB150-P

Current Transducer HTB 50 .. 400 - P and HTB 50 .. 100 - TP
LEM

HTB1A60

4 Quadrants Sensitive TRIAC
SEMIHOW

HTB1A80

4 Quadrants Sensitive TRIAC
SEMIHOW

HTB200-P

Current Transducers HTB 50~400-P and HTB 50~100-TP
LEM

HTB200-P/SP5

Current Transducers HTB 50~400-P/SP5 and HTB 50~100-TP/SP5
LEM

HTB200-SP5

Current Transducers
LEM