HTB100-P_07 [LEM]

Current Transducers; 电流传感器
HTB100-P_07
型号: HTB100-P_07
厂家: LEM    LEM
描述:

Current Transducers
电流传感器

传感器
文件: 总2页 (文件大小:637K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Current Transducers HTB 50..400-P/SP5  
and HTB 50..100-TP/SP5  
IPN = 50 .. 400 A  
For the electronic measurement of currents: DC, AC, pulsed, mixed,  
with a galvanic isolation between the primary circuit (high power) and  
the secondary circuit (electronic circuit).  
Electrical data  
Primarynominal  
current rms  
IPN (A)  
Primary current  
measuring range  
IPM (A)  
Type  
Features  
50  
± 150  
± 300  
± 500  
± 600  
± 600  
HTB 50-P/SP5, HTB 50-TP/SP51)  
HTB 100-P/SP5, HTB 100-TP/SP51)  
HTB 200-P/SP5  
HTB 300-P/SP5  
HTB 400-P/SP5  
100  
200  
300  
400  
· Hall effect measuring principle  
· Galvanic isolation between primary  
and secondary circuit  
· Isolationvoltage2500V  
· Low power consumption  
· Primary bus bar option for 50A and  
100A version for ease of connection  
VC  
Supply voltage (± 5 %)2)  
+ 12 .. 15  
V
mA  
kV  
IC  
Current consumption  
< 15  
Vd  
Rms voltage for AC isolation test, 50 Hz, 1 min  
Isolation resistance @ 500 VDC  
Output voltage (Analog) @ ± IPN, RL = 10 kW, TA = 25°C  
Output internal resistance  
2.5  
RIS  
VOUT  
ROUT  
RL  
> 500  
VOE ± 1.667  
100  
MW  
V
Special feature  
W
Load resistance  
³ 10  
kW  
· Single power supply from 12V to 15V  
Accuracy - Dynamic performance data  
Advantages  
X
Accuracy @ IPN, TA = 25°C (excluding offset)  
Linearity error (0 .. ± IPN)  
< ± 1 % of IPN  
< ± 1 % of IPN  
Vc/2 ± 30 mV  
e
· Small size and space saving  
· Only one design for wide current  
ratings range  
· High immunity to external  
interference.  
L
VOE  
VOH  
Electrical offset voltage @ TA = 25°C  
Hysteresis offset voltage @ IP = 0,  
after an excursion of 1 x IPN  
< ± 0.5 % of IPN  
TCVOE  
Temperature coefficient of VOE HTB50-(T)P/SP5  
< ± 1.0 mV/K  
HTB100-(T)P..400-P/SP5 < ± 0.5  
mV/K  
TCVOUT  
tr  
Temperature coefficient of VOUT (% of reading)  
Response time to 90% of IPN step  
Frequency bandwidth (0 .. -3 dB)3)  
< ± 0.05 %/K  
Applications  
< 3  
ms  
· AC variable speed drives  
· Static converters for DC motor drives  
· Battery supplied applications  
· Uninterruptible Power Supplies  
(UPS)  
· Switched Mode Power Supplies  
(SMPS)  
· Power supplies for welding  
applications.  
BW  
DC .. 50  
kHz  
General data  
TA  
TS  
m
Ambient operating temperature  
Ambient storage temperature  
Mass (-TP version)  
- 25 .. + 85 °C  
- 25 .. + 85 °C  
< 30 (< 36)  
g
Notes :  
1)  
-TP version is equipped with a primary bus bar.  
Operating at +12V £ Vc < +15V will reduce measuring range.  
Derating is needed to avoid excessive core heating at high frequency.  
2)  
3)  
Page 1/2  
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice.  
070111/1  
www.lem.com  
Dimensions HTB 50..400-P/SP5 and HTB 50..100-TP/SP5 (in mm. 1 mm = 0.0394 inch)  
HTB 50..400-P/SP5  
Left view  
Back view  
Positive Current Flow  
39  
14 MAX.  
2 1  
3
4-0.635x0.635  
3
24.5  
5.5  
Secondary Pin Identification  
2-P=2.5  
2-d2  
Mounting Pins  
1 +Vc  
2 0V  
3 Output  
3
10  
19  
39  
Bottom View  
HTB 50..100-TP/SP5  
Back view  
Left view  
14 MAX.  
32 1  
1.5  
1.5  
1.5  
3-0.635x0.635  
10  
3
Positive Current Flow  
10.5  
2-P=2.5  
9
3
Secondary Pin Identification  
6-1.5x1.5  
3.25  
1 +Vc  
2 0V  
3 Output  
3
Bottom view  
Page 2/2  
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice.  
070111/1  
www.lem.com  

相关型号:

HTB100-SP5

Current Transducers
LEM

HTB100-SP51

Current Transducers
LEM

HTB100-TP

Current Transducers HTB 50~400-P and HTB 50~100-TP
LEM

HTB100-TP/SP5

Current Transducers HTB 50~400-P/SP5 and HTB 50~100-TP/SP5
LEM

HTB100-TP1

Current Transducers
LEM

HTB150-P

Current Transducer HTB 50 .. 400 - P and HTB 50 .. 100 - TP
LEM

HTB1A60

4 Quadrants Sensitive TRIAC
SEMIHOW

HTB1A80

4 Quadrants Sensitive TRIAC
SEMIHOW

HTB200-P

Current Transducers HTB 50~400-P and HTB 50~100-TP
LEM

HTB200-P/SP5

Current Transducers HTB 50~400-P/SP5 and HTB 50~100-TP/SP5
LEM

HTB200-SP5

Current Transducers
LEM

HTB2800S

HIGH TEMPERATURE HYBRID DC-DC CONVERTER
INFINEON