HTB150-P [LEM]

Current Transducer HTB 50 .. 400 - P and HTB 50 .. 100 - TP;
HTB150-P
型号: HTB150-P
厂家: LEM    LEM
描述:

Current Transducer HTB 50 .. 400 - P and HTB 50 .. 100 - TP

文件: 总3页 (文件大小:551K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Current Transducer HTB 50 .. 400 - P  
and HTB 50 .. 100 - TP  
For the electronic measurement of currents: DC, AC, pulsed...,  
with a galvanic isolation between the primary circuit (high power) and  
the secondary circuit (electronic circuit).  
IPN = 50 .. 400 A  
Electrical data  
Primary nominal  
current rms  
IPN (A)  
Primary current  
measuring range  
IPM (A)  
Type  
Features  
± 50  
± 150  
± 300  
± 450  
± 500  
± 600  
± 600  
HTB 50-P, HTB 50-TP1)  
HTB 100-P, HTB 100-TP1)  
HTB 150-P  
HTB 200-P  
HTB 300-P  
● Hall effect measuring principle  
● Galvanic isolation between  
primary and secondary circuit  
● Isolation voltage 2500 V  
● Low power consumption  
● Wide power supply: ± 12 ..15 V  
● Primary bus bar option for 50  
A and 100 A version for ease of  
connection  
± 100  
± 150  
± 200  
± 300  
± 400  
HTB 400-P  
VC  
IC  
Supply voltage (± 5 %)2)  
Current consumption  
± 12 ..15  
± 15  
2.5  
> 500  
± 4  
100  
> 10  
V
mA  
kV  
MW  
V
Vd  
Rms voltage for AC isolation test, 50 Hz, 1 min  
Isolation resistance @ 500 VDC  
Output voltage (Analog)@ ± IPN, RL = 10kW, TA = 25°C  
Output internal resistance  
RIS  
VOUT  
ROUT  
RL  
Advantages  
W
kW  
Load resistance  
● Small size and space saving  
● Only one design for wide current  
ratings range  
Accuracy - Dynamic performance data  
● High immunity to external  
interference.  
X
Accuracy @ IPN, TA = 25°C (excluding offset)  
Linearity error (0 .. ± IPN)  
Electrical offset voltage @ TA = 25°C  
Hysteresis offset voltage @ IP = 0;  
< ± 1  
< ± 1  
< ± 30  
% of IPN  
% of IPN  
mV  
e
L
Applications  
VOE  
VOH  
● AC variable speed drives  
● Static converters for DC motor  
drives  
● Battery supplied applications  
● Uninterruptible Power Supplies  
(UPS)  
after an excursion of 1 x IPN < ± 1  
% of IPN  
mV/K  
mV/K  
%/K  
TCVOE Temperature coefficient of VOE HTB 50-(T)P  
HTB 100-(T)P .. 400-P  
TCVOUT Temperature coefficient of VOUT (% of reading)  
tr  
BW  
< ± 2.0  
< ± 1.0  
< ± 0.1  
< 3  
Response time to 90% of IPN step  
Frequency bandwidth (- 3 dB)3)  
µs  
kHz  
DC .. 50  
● Switched Mode Power Supplies  
(SMPS)  
General data  
● Power supplies for welding  
applications  
TA  
TS  
m
Ambient operating temperature  
Ambient storage temperature  
Mass  
Standards  
- 40 .. + 80  
- 40 .. + 85  
< 30 ( < 36)  
EN 50178 :  
°C  
°C  
g
Application domain  
● Industrial  
1997  
2 pins of Ø2mm diameter are available on transducer  
for PCB soldering  
Notes : 1) -TP version is equipped with a primary bus bar.  
2) Operating at ±12V ≤ Vc < ±15V will reduce the measuring range.  
3) Derating is needed to avoid excessive core heating at high frequency.  
Page 1/3  
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice.  
120425/12  
www.lem.com  
Current Transducer HTB 50 .. 400-P and HTB 50 .. 100-TP  
Isolation characteristics  
Vd  
Ve  
Vw  
Rms voltage for AC isolation test, 50 Hz, 1 min  
Partial discharge extinction voltage rms @ 10pC  
Impulse withstand voltage 1.2/50 µs  
2.5  
> 500  
4
kV  
V
kV  
dCp  
dCl  
CTI  
Creepage distance  
Clearance distance  
Comparative tracking index (Group IIIa)  
> 4.5  
> 4.5  
275  
mm  
mm  
Application examples  
According to EN 50178 and CEI 61010-1 standards and following conditions :  
- Over voltage category III  
- Pollution degree 2  
- Heterogeneous field  
EN 50178  
IEC 61010-1  
Single isolation  
300 V  
150 V  
300 V  
150 V  
Reinforced isolation  
Safety  
This transducer must be used in electric/electronic equipment with respect  
to applicable standards and safety requirements in accordance with the  
manufacturer’s operating instructions.  
Caution, risk of electrical shock  
When operating the transducer, certain parts of the module can carry hazardous  
voltage (eg. primary busbar, power supply).  
Ignoring this warning can lead to injury and/or cause serious damage.  
This transducer is a built-in device, whose conducting parts must be inaccessible  
after installation.  
A protective housing or additional shield could be used.  
Main supply must be able to be disconnected.  
Page 2/3  
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice.  
120425/12  
www.lem.com  
Dimensions HTB 50 .. 400-P and HTB 50 .. 100-TP (in mm. 1 mm = 0.0394 inch)  
Page 3/3  
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice.  
120425/12  
www.lem.com  

相关型号:

HTB1A60

4 Quadrants Sensitive TRIAC
SEMIHOW

HTB1A80

4 Quadrants Sensitive TRIAC
SEMIHOW

HTB200-P

Current Transducers HTB 50~400-P and HTB 50~100-TP
LEM

HTB200-P/SP5

Current Transducers HTB 50~400-P/SP5 and HTB 50~100-TP/SP5
LEM

HTB200-SP5

Current Transducers
LEM

HTB2800S

HIGH TEMPERATURE HYBRID DC-DC CONVERTER
INFINEON

HTB2800S_15

HIGH TEMPERATURE HYBRID DC-DC CONVERTER
INFINEON

HTB300-P

Current Transducers HTB 50~400-P and HTB 50~100-TP
LEM

HTB300-P/SP5

Current Transducers HTB 50~400-P/SP5 and HTB 50~100-TP/SP5
LEM

HTB300-SP5

Current Transducers
LEM

HTB400-P

Current Transducers HTB 50~400-P and HTB 50~100-TP
LEM

HTB400-P/SP5

Current Transducers HTB 50~400-P/SP5 and HTB 50~100-TP/SP5
LEM