MM-0637A-50B [JMK]

Operating Voltage = 48 Vdc Operating Current = 50 Amperes; 工作电压= 48伏直流工作电流= 50安培
MM-0637A-50B
型号: MM-0637A-50B
厂家: JMK INC.    JMK INC.
描述:

Operating Voltage = 48 Vdc Operating Current = 50 Amperes
工作电压= 48伏直流工作电流= 50安培

文件: 总1页 (文件大小:49K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
MM-0637A-50B  
LOAD  
LINE  
Operating Voltage = 48 Vdc  
Operating Current = 50 Amperes  
Operating Temperature Range = -40 to 50 C  
Dielectric Withstanding Voltage  
Line to Line: 707 Vdc for 1 minute  
Line to Case: 2250 Vdc for 1.0 min  
Order P/N:  
MM-0637A-50B  
Safety Agency Approvals  
INSERTION LOSS vs. FREQUENCY  
MM-0637A-50B  
70  
60  
50  
40  
30  
20  
EN  
R
60 950  
C
US  
This compact filter is intended to provide noise reduction  
for telecommunications DC power. The filter is non-  
polarized and the insertion loss is specified at full load.  
DM  
CM  
10  
0
If modifications are needed to suppress transients, or if  
more severe temperature operating parameters are re-  
quired, call or e-mail our Engineering Dept. They will be  
more than happy to assist you.  
.01  
.04  
.1  
.4  
1
4
10  
40  
100  
70  
.02  
2
7
.07  
.2  
.7  
20  
FREQUENCY (MEGAHERTZ)  
.25-20 UNC-2A (4 PL)  
.220 DIA (2 PL)  
.62 DIA (4PL)  
3.10  
1.25  
2.74  
2.25  
.50  
1.00  
.60  
.13  
.75  
2.60  
1.18  
USA  
EUR  
JMK Inc 15 Caldwell Dr. Amherst, NH 03031 PH: 603 886-4100  
email: info@jmkfilters.com  
JMK Inc Glasgow G13 1DN Scotland UK PH: 44-(0) 7785310729 FX: 44-(0) 141 589 1884  
FX: 603 886-4115  

相关型号:

MM-0637A-50C

Operating Voltage = 48 Vdc Operating Current = 50 Amperes
JMK

MM-0637A-50D

Operating Voltage = 48 Vdc (Typical) Operating Voltage Max. = 0-75Vdc
JMK

MM-0637A-60B

Operating Voltage = 48 Vdc Operating Current = 40,50,60 Amperes
JMK

MM-0637A-60C

Operating Voltage = 48 Vdc Operating Current = 40,50,60 Amperes
JMK

MM-0637A-60D

Operating Voltage = 48 Vdc (Typical) Operating Voltage Max. = 0-75Vdc
JMK

MM-0787-100B

The Mm-0787-100B filter is designed for use with large computer or motor installations where heavy current is drawn continuously.
JMK

MM-0787-60B

Operating Voltage = 250/480 V~, 50 / 60 Hz Operating Voltage = 125/208 V~, 50 - 400 Hz
JMK

MM-0787-80B

Operating Voltage = 250/480 V~, 50 / 60 Hz Operating Voltage = 125/208 V~, 50 - 400 Hz
JMK

MM-1018-H

Micro-miniature Reed Switch
RRE

MM-1018-L

Micro-miniature Reed Switch
RRE

MM-1018-M

Micro-miniature Reed Switch
RRE

MM-1208-100

Operating Voltage= 250 / 480 VAC 3 PH Wye OperatingCurrentMax= 80, 100amp
JMK