FCDM082J1437/02.5 [IVO]
Through Beam Photoelectric Sensor, 1437.5mm Max, Rectangular, Panel Mount;型号: | FCDM082J1437/02.5 |
厂家: | BAUMER IVO GMBH & CO. KG |
描述: | Through Beam Photoelectric Sensor, 1437.5mm Max, Rectangular, Panel Mount 传感器 换能器 |
文件: | 总2页 (文件大小:114K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
SpiderScan detection and measuring light barriers
FCDM 082
Sb = 6,5 m
ꢀ high resolution
ꢀ 100 kHz high clock frequency
ꢀ rugged aluminum housing material
included in delivery
synchronization cable
connector 7 pin (power)
connector RS 422 interface
connector SSI/parallel according interface
other cable lengths on request
general data
measuring field
actual range Sb
beam distance
resolution
length 5 m
237,5 ... 1677,5 mm
< 6,5 m
2,5 mm
2,5 mm
number of beams
alignment aid
light source
96 ... 672
LED green
infrared diode
950 nm
accessories
programming kit:
10163150
wave length
software „SpiderView 082/02.5“
interface cable with converter
RS 422/RS 232
clock frequency
clock speed per beam
100 kHz
length 5 m
10 µs
manual
analysis time
200 µs
electrical data
voltage supply range +Vs
residual ripple
24 VDC 10ꢀ
< 200 mV
1,2 A
current consumption max.
short circuit protection
reverse polarity protection
mechanical data
width / diameter
depth
yes
yes
82 mm
40 mm
type
rectangular
aluminum
housing material
ambient conditions
operating temperature
humidity
-25 ... +55 °C
0 ... 90 ꢀ (non condensed)
IP 65
protection class
order reference
number of beams
measuring field Lm
237,5 mm
height/length L
L1
FCDM 082x0237/02.5
FCDM 082x0477/02.5
FCDM 082x0717/02.5
FCDM 082x0957/02.5
FCDM 082x1197/02.5
FCDM 082x1437/02.5
FCDM 082x1677/02.5
96
390 mm
630 mm
870 mm
1110 mm
1350 mm
1590 mm
1830 mm
128,5 mm
192
288
384
480
576
672
477,5 mm
128,5 mm
128,5 mm
128,5 mm
128,5 mm
128,5 mm
128,5 mm
717,5 mm
957,5 mm
1197,5 mm
1437,5 mm
1677,5 mm
interface
J
I
B
RS 422
SSI + RS 422
parallel 10 Bit + RS 422
www.baumer.com
5.48
SpiderScan detection and measuring light barriers
FCDM 082
configuration
mounting
If a configuration different from the factory setting is desired, this must
be specified in the order. Other settings can also be made with the
programming kit.
factory setup
optional
data format
actual range
normal
"largest blocked area" or
"over all"
groove plate (1 piece)
part nr. 10161963
0,6 ... 1 m
... m
(min. 0,2 m / max. 6,5 m)
output mode
coding
number of beams mm
binary
no
«Gray» or «BCD»
double scanning
smoothing data
yes
1 beam
... beams
dimension drawing
82
www.baumer.com
5.49
相关型号:
©2020 ICPDF网 联系我们和版权申明