ASA28XXS SERIES  
28V Input, Single Output  
ADVANCED ANALOG  
HIGH RELIABILITY  
HYBRID DC/DC CONVERTERS  
Description  
The ASA28XXS Series of DC/DC converters are high  
reliability thick film hybrid converters that use flyback  
topology operating at a nominal frequency of 550Khz.  
High input to output isolation is achieved through the  
use of transformers in the flyback power and feedback  
circuits.  
ASA  
Features  
The advanced feedback design provides fast loop re-  
sponse for superior line and load transient characteris-  
tics and offers greater reliability than devices incorpo-  
rating optical feedback circuits.  
n Up To 5 Watt Output Power  
n 5, 12,15 Volt Outputs  
n High Reliability  
n Wide Input Voltage Range -16 To 40 Volts  
n Indefinite Short Circuit and Overload  
Protection  
n Popular Industry Standard Pin-Out  
n Military Screening Available  
n Parallel Seam Welded Package  
n No External Capacitors Required  
n Input Voltage Surge Protected to  
MIL-STD-704A  
This device is designed to meet MIL-STD-704D input  
requirements offering full performance over a 16 to 40  
volt input range. Output Power of up to 5 watts is avail-  
able.  
Connecting the inhibit pin (pin 5) to the input common  
(pin 7) will cause the converter to shut down. It is rec-  
ommended that the inhibit pin be driven by an open  
collector device capable of sinking at least 400µA. The  
open circuit voltage of the inhibit pin is 11.5 ±0.5 volts.  
n Under Voltage Lockout  
n Available as Standard Military Drawing  
These converters are manufactured in a facility fully  
qualified to MIL-PRF-38534. All processes used to  
manufacture these converters have been qualified  
thereby enabling Advanced Analog to deliver fully com-  
pliant devices. Three standard temperature grades are  
offered with the screening options. Refer to Screening  
Level section. The CH grade converters are fully com-  
pliant to MIL-PRF-38534 for class H. The HB grade  
converters are processed with the same screening as  
the CH grade, but do not have class H element evalua-  
tion as required by MIL-PRF-38534. These two grades  
are fully tested and operate over the full military tem-  
perature range without derating of output power. A  
commercial grade is also available. Variations in elec-  
trical, mechanical and screening requirements can be  
accommodated. Extensive computer simulation using  
complex modeling allows design modifications  
to be examined. Contact Advanced Analog with  
specific requirements.  
www.irf.com  
1
09/11/02  
ASA28XXS Series  
Specifications  
ABSOLUTE MAXIMUM RATINGS  
Input Voltage  
Power Output  
-0.5 V to 50 V Continuous. 80 V, 100 mSec  
Internally limited (6.5 Wtypical)  
300°C for 10 Sec.  
Soldering  
Temperature Range  
Operating -55°C to +125°C Case  
Storage  
-65°C to +150°C  
Conditions  
ASA2805S/xx  
ASA2812S/xx  
ASA2815S/xx  
-55° TC +125°C  
IN = 28V dc ±5% CL = 0  
unless otherwise specified  
Group A  
Subgroups  
V
Min  
Max  
Min  
Max  
Min  
Max  
TEST  
Unit  
V
1
4.95  
4.90  
5.05  
5.10  
11.88  
11.76  
12.12  
12.24  
14.85  
14.70  
15.15  
15.30  
Output voltage  
IOUT = 0  
2, 3  
1
V
IN = 16, 28, and 40 V dc  
IN = 16, 28 and 40 V dc  
Output current  
1, 2, 3  
1
1000  
190  
475  
25  
417  
333  
200  
290  
±25  
±50  
±25  
±50  
18  
mA  
2
V
200  
290  
mV PP  
Output ripple voltage  
Line regulation  
2, 3  
1
±25  
±50  
±25  
±50  
18  
VIN = 16, 28, and 40 V dc  
OUT = 0, 50%, 100% IMAX  
mV  
mV  
I
2, 3  
1
50  
25  
Load regulation  
VIN = 16, 28, and 40 V dc  
IOUT = 0, 50%, 100% IMAX  
2, 3  
50  
IOUT = 0 Pin 5 to Pin 7  
IOUT = 0 Pin5 open  
IOUT = IMAX  
18  
1, 2, 3  
1, 2, 3  
mA  
Input current  
50  
50  
50  
2
100  
100  
100  
mA  
Input ripple current  
Efficiency  
PP  
1
71  
68  
71  
68  
IOUT = IMAX  
66  
%
2, 3  
Isolation - Input to  
output or any pin to  
case  
VTEST 500 Vdc, Tc= +25°C  
1
100  
100  
100  
MΩ  
3, 4  
No effect on dc  
performance, Tc = +25°C  
Capacitive load  
4
500  
200  
200  
µf  
5
4.0  
2.0  
600  
4.0  
2.0  
600  
4.0  
2.0  
600  
Power dissipation, load  
fault  
Overload  
1, 2, 3  
W
Short circuit  
IOUT = IMAX  
4
4, 5, 6  
500  
500  
500  
KHz  
Switching frequency  
4
-300  
-450  
-500  
-750  
+300  
+450  
+500  
+700  
200  
Output response to step ½ IMAX ó IMAX  
-450  
+450  
+750  
-400  
+450  
+750  
transient load changes  
5, 6  
4
mV pk  
6
0 mA ó IMAX  
-750  
-800  
5, 6  
IOUT = IMAX  
100  
1
100  
1
µS  
Recovery time, step  
4, 5, 6  
4, 5, 6  
transient load changes  
0 mA ó ½ IMAX  
1
ms  
Output response  
transient step line  
Input step 16 ó 40 V dc  
IOUT = IMAX  
500  
1000  
1000  
mV pk  
4
8
changes  
Recovery time transient  
4, 7, 8  
step line changes  
Input step 16 ó 40 V dc  
IOUT = IMAX  
4, 5, 6  
800  
800  
800  
µS  
Turn on overshoot  
IOUT = 0 mA, IMAX  
4, 5, 6  
4, 5, 6  
600  
20  
600  
25  
600  
25  
mV pk  
ms  
9
IOUT = 0 or IMAX  
Turn on delay  
4
4, 5, 6  
20  
25  
25  
ms  
Load fault recovery  
For Notes to Specifications, refer to page 3  
2
www.irf.com  
ASA28XXS Series  
Notes to Specifications  
1.  
2.  
3.  
Parameter guaranteed and measured during line and load regulation tests.  
Bandwidth guaranteed by design. Tested for 20 kHz to 2 MHz.  
Capacitive load may be any value from 0 to the maximum limit without compromising dc performance. A capacitive load in excess  
of the maximum limit will not disturb loop stability but may interfere with the operation of the load fault detection circuitry,  
appearing as a short circuit during turn-on.  
4.  
5.  
Parameter shall be tested as part of design characterization and after design or process changes.  
An overload is that condition of load in excess of rated load but less than that necessary to trigger the short circuit protection  
and is the condition of maximum power dissipation.  
6.  
7.  
Load step transition time between 2 and 10 microseconds.  
Recovery time is measured from the initiation of the transient to where VOUT has returned to within ±1 percent of VOUT at 50  
percent load.  
8.  
9.  
Input step transition time between 2 and 10 microseconds.  
Turn-on delay time measurement is for either a step application of power at the input or the removal of a ground signal from the  
inhibit pin (pin 2) while power is applied to the input.  
Available Screening Levels and ProcessVariations for ASA28XXS Series  
MIL-STD-883  
Method  
No  
ES  
HB  
CH  
Requirement  
Temperature Range  
Element Evaluation  
Internal Visual  
Suffix  
Suffix  
Suffix  
Suffix  
-20°C to +85°C  
-55°C to +125°C  
-55°C to +125°C  
-55°C to +125°C  
MIL-PRF-38534  
ü
2017  
1010  
¬
ü
Cond B  
500g  
ü
Temperature Cycle  
Constant Acceleration  
Burn-in  
Cond C  
Cond C  
2001,  
Cond A  
Cond A  
1015  
48hrs @ 85°C  
25°C  
48hrs @ 125°C  
25°C  
160hrs @ 125°C  
160hrs @ 125°C  
Final Electrical (Group A)  
Seal, Fine & Gross  
External Visual  
MIL-PRF-38534  
1014  
-55, +25, +125°C -55, +25, +125°C  
Cond C  
¬
Cond A, C  
ü
Cond A, C  
Cond A, C  
2009  
ü
ü
* per Commercial Standards  
Available Standard Military Drawing (SMD) Cross Reference  
ASA2805S/CH  
ASA2812S/CH  
ASA2815S/CH  
5962-9462901  
5962-9463101  
5962-9463001  
Part Numbering  
ASA 28 05 S / CH  
Model  
Screening  
, ES, HB, CH  
Input Voltage  
28 = 28V  
Output Voltage  
Outputs  
S = Single  
D = Dual  
5 = ±5, 12 = ±12,  
15 = ±15  
www.irf.com  
3
ASA28XXS Series  
ASA28XXS Block Diagram  
1
6
+Output  
+Input  
Return  
2
Error  
Amplifier  
Return  
7
Case  
8
Enable  
5
Controller  
ASA28XXS Pin Designation  
ASA28XXS Case Outline  
Pin No.  
Designation  
1.075  
0.800  
1
2
3
4
5
6
7
8
Positive Output  
Output Return  
N/C  
0.270  
1
2
3
4
5
N/C  
0.800  
±.005  
Enable  
1.075  
Positive Input  
Input Return  
Case  
8
7
6
0.025 ± .003 Dia Pins  
0.220  
WORLD HEADQUARTERS: 233 Kansas St., El Segundo, California 90245, Tel: (310) 322 3331  
ADVANCED ANALOG: 2270 Martin Av., Santa Clara, California 95050, Tel: (408) 727-0500  
Visit us at www.irf.com for sales contact information.  
Data and specifications subject to change without notice. 09/02  
4
www.irf.com  

相关型号:

ASA2805S-HB

ADVANCED ANALOG HIGH RELIABILITY HYBRID DC/DC CONVERTERS
INFINEON

ASA2805S/CH

HYBRID-HIGH RELIABILITY DC/DC CONVERTER
INFINEON

ASA2805S/CHPBF

DC-DC Regulated Power Supply Module, 1 Output, 5W, Hybrid
INFINEON

ASA2805S/ES

HYBRID-HIGH RELIABILITY DC/DC CONVERTER
INFINEON

ASA2805S/HB

HYBRID-HIGH RELIABILITY DC/DC CONVERTER
INFINEON

ASA2805SCH

HYBRID-HIGH RELIABILITY DC/DC CONVERTER
INFINEON

ASA2805SES

HYBRID-HIGH RELIABILITY DC/DC CONVERTER
INFINEON

ASA2805SHB

HYBRID-HIGH RELIABILITY DC/DC CONVERTER
INFINEON

ASA2810D

HYBRID-HIGH RELIABILITY DC-DC CONVERTER
INFINEON

ASA2810D_15

HYBRID-HIGH RELIABILITY DC-DC CONVERTER
INFINEON

ASA2812D

DC-DC Regulated Power Supply Module, 2 Output, 5W, Hybrid, 1.065 X 1.075 X 0.270 INCH, PACKAGE-8
INFINEON

ASA2812D-CH

ADVANCED ANALOG HIGH RELIABILITY HYBRID DC/DC CONVERTERS
INFINEON