RP40-2415DFR/N-HC [ETC]
CONV DC/DC 40W 9-36VIN +/-15VOUT;型号: | RP40-2415DFR/N-HC |
厂家: | ETC |
描述: | CONV DC/DC 40W 9-36VIN +/-15VOUT |
文件: | 总12页 (文件大小:683K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
• Wide 4:1 input voltage range
• 1.6kVDC isolation for 24Vin and 48Vin,
3kVDC isolation for 110Vin
Features
DC/DC Converter
• Efficiency up to 92%
Regulated
Converter
• Six-sided continuous shield
• EN50155, UL/IEC/EN60950-1 certified
RP40-FR
40 Watt
2“ x 1“
Single and Dual
Output
Description
3
The RP40-FR series wide range input DC/DC converters have been especially designed for railway
applications and are EN50155 certified. They are also certified to UL60950-1 and cUL 60950-1, this
makes them ideal for all high input voltage telecom and industrial applications where approved safety
standards are required.
Selection Guide
Part Number
Input
Output
Output
Current
[mA]
Input (1) Efficiency (1) Max. Capacitive
Voltage Range Voltage
Current
[mA]
typ.
[%]
Load (2)
[µF]
[VDC]
9-36
9-36
9-36
9-36
[VDC]
3.3
5
12
15
24
3.3
5
12
15
24
3.3
5
12
15
24
12
15
24
12
15
24
12
15
24
RP40-243.3SFR (3,4)
RP40-2405SFR (3,4)
RP40-2412SFR (3,4)
RP40-2415SFR(3,4)
RP40-2424SFR (3,4)
RP40-483.3SFR (3,4)
RP40-4805SFR (3,4)
RP40-4812SFR (3,4)
RP40-4815SFR (3,4)
RP40-4824SFR (3,4)
RP40-1103.3SFR (3,4)
RP40-11005SFR (3,4)
RP40-11012SFR (3,4)
RP40-11015SFR (3,4)
RP40-11024SFR (3,4)
RP40-2412DFR (3,4)
RP40-2415DFR (3,4)
RP40-2424DFR (3,4)
RP40-4812DFR (3,4)
RP40-4815DFR (3,4)
RP40-4824DFR (3,4)
RP40-11012DFR (3,4)
RP40-11015DFR (3,4)
RP40-11024DFR (3,4)
10000
8000
3333
2666
1666
10000
8000
3333
2666
1666
10000
8000
3333
2666
1666
1666
1333
833
1528
1832
1811
1811
1831
764
916
906
906
915
90
91
92
92
91
90
91
92
92
91
88
89
90.5
91
90
90
90
91
90
90
91
89
89
91
26600
20000
3900
2600
1300
26600
20000
3900
2600
1300
26600
20000
3900
2600
1300
2600
1600
650
9-36
18-75
18-75
18-75
18-75
18-75
43-160
43-160
43-160
43-160
43-160
9-36
RoHS2
+
REACH
compliant
compliant
10 from 10
E196683
341
409
402
400
EN50155 certified
404
UL60950-1 certified
IEC/EN60950-1 certified
EN55032 compliant
EN55024 compliant
EN50121-3-2 compliant
1851
1851
1830
925
741
572
408
408
400
9-36
9-36
18-75
18-75
18-75
43-160
43-160
43-160
1666
1333
833
1666
1333
833
2600
1600
650
2600
1600
650
REF
Notes:
DESIGN
available
Note1: Maximum values at nominal input voltage and full load at +25°C ambient
Note2: Max. Cap load is tested at minimum input and constant resistive load
Model Numbering
https://recom-power.com/
rec-s-R-REF04-RIA12.html
RP40-__ __ _FR/_- _
(4)
“Package
”
nom. Input Voltage
(3)
“CTRL Logic
”
nom. Output Voltage
SURGE
PROTECTOR
available
Single or Dual
Notes:
Note3: standard part is with suffix “P” for positive logic (1=ON, 0=OFF)
or add suffix “N” instead for negative logic (0=ON, 1=OFF)
Note4: add suffix “-HC” for premounted Heat-sink with clips
Ordering Examples
RP40-2405SFR/P = 24V input, 5V output, single, positive Logic CTRL pin
RP40-4812DFR/N-HC = 48V input, 12V output, dual, negative Logic CTRL pin, Heat-sink premounted
https://recom-power.com/rec-s-
RSPxxx-168.html
www.recom-power.com
REV.: 8/2020
PD-1
RP40-FR
DC/DC Converter
Specifications (measured @ Ta= 25°C, nom. Vin, full load unless otherwise stated)
Series
BASIC CHARACTERISTICS
Parameter
Condition
Min.
Typ.
Max.
Internal Input Filter
Pi-Type
nom. Vin = 24VDC
nom. Vin = 48VDC
nom. Vin = 110VDC
9VDC
18VDC
43VDC
24VDC
48VDC
110VDC
36VDC
75VDC
160VDC
50VDC
100VDC
170VDC
9VDC
Input Voltage Range
Input Surge Voltage
nom. Vin = 24VDC
nom. Vin = 48VDC
nom. Vin = 110VDC
DC-DC ON
1s max.
nom. Vin = 24VDC
nom. Vin = 48VDC
nom. Vin = 110VDC
DC-DC OFF
8VDC
16VDC
40VDC
DC-DC ON
DC-DC OFF
18VDC
43VDC
Under Voltage Lockout (UVLO)
DC-DC ON
DC-DC OFF
refer to
3.3Vout, 5Vout, 12Vout
15Vout, 24Vout
-10%
-10%
+10%
+20%
Output Voltage Trimming
Start-up Time
„OUTPUT VOLTAGE TRIMMING“
Power up
ON/OFF CTRL
60ms
60ms
V
DC-DC ON
DC-DC OFF
Open or 3.0VDC < CTRL< 12VDC
Positive Logic
Negative Logic
ON/OFF CTRL (5)
refer to “ON/OFF CTRL”
V
Short or 0VDC < CTRL< 1.2VDC
V
DC-DC ON
DC-DC OFF
Short or 0VDC < CTRL< 1.2VDC
V
Open or 3.0VDC < CTRL< 12VDC
drive current
DC-DC OFF
-0.5mA
225kHz
+0.5mA
3mA
Input Current of CTRL pin
Standby Current
ICTRL
IIn
Internal Operating Frequency
250kHz
275kHz
3.3Vout, 5Vout
12Vout, 15Vout
24Vout
75mVp-p
100mVp-p
150mVp-p
100mVp-p
125mVp-p
200mVp-p
measured by 20MHz bandwidth
with a 1µF/50V X7R MLCC
Output Ripple and Noise
Input Reflected Ripple Current
30mAp-p
Notes:
Note5: The ON/OFF control function can be positive or negative logic. The pin voltage is referenced to -Vin pin
RP40-2405SFR
Efficiency vs. Output Current
Efficiency vs. Input Voltage
100
90
80
70
60
50
40
30
20
10
100
90
80
70
60
50
40
30
20
10
0
9Vin
24Vin
36Vin
0
10
20
30
40
50
60
70
80
90
100
9
12
15
18
21
24
27
30
33
36
Output Current [%]
Input Voltage [VDC]
continued on next page
REV.: 8/2020
www.recom-power.com
PD-2
RP40-FR
DC/DC Converter
Specifications (measured @ Ta= 25°C, nom. Vin, full load unless otherwise stated)
Series
RP40-4805SFR
Efficiency vs. Input Voltage
Efficiency vs. Output Current
100
90
80
70
60
50
40
30
20
10
0
100
90
80
70
60
50
40
30
18Vin
48Vin
75Vin
20
10
0
10
20
30
40
50
60
70
80
90
100
18
24
30
36
42
48
54
60
66
72
75
Output Current [%]
Input Voltage [VDC]
RP40-11005SFR
Efficiency vs. Output Current
Efficiency vs. Input Voltage
100
90
80
70
60
50
40
30
20
10
0
100
90
80
70
60
50
40
30
20
10
0
43Vin
110Vin
160Vin
10
20
30
40
50
60
70
80
90
100
43 52 62 72 84 96 110 125 136 143 160
Output Current [%]
Input Voltage [VDC]
OUTPUT VOLTAGE TRIMMING
Output Voltage Trimming
Single output Powerline converters offer the feature of trimming the output voltage over a certain range around the nominal value by using external
trim resistors. No general equation can be given for calculating the trim resistors, but the following trimtables give typical values for chosing these
trimming resistors. If voltages between the given trim points are required, extrapolate between the two nearest given values to work out the resistor
required or use a variable resistor to set the output voltage. Output can be externally trimmed by using the method shown below.
Trim up
Trim down
Trim
Trim
R
R
D
U
-Vout
+Vout
continued on next page
REV.: 8/2020
www.recom-power.com
PD-3
RP40-FR
DC/DC Converter
Specifications (measured @ Ta= 25°C, nom. Vin, full load unless otherwise stated)
Series
RP40-xx3.3SFR
[%]
[VDC]
[kW]
Trim up
Vout =
RU =
1
2
3
4
5
6
7
8
9
10
3.333
57.93
3.366
26.16
3.399
15.58
3.432
10.28
3.465
7.11
3.498
4.99
3.531
3.48
3.564
2.34
3.597
1.46
3.63
0.75
[%]
[VDC]
[kW]
Trim down
Vout =
RD =
1
2
3
4
5
6
7
8
9
10
3.267
69.47
3.234
31.23
3.201
18.49
3.168
12.12
3.135
8.29
3.102
5.74
3.069
3.92
3.036
2.56
3.003
1.50
2.97
0.65
RP40-xx05SFR
[%]
[VDC]
[kW]
Trim up
1
2
3
4
5
6
7
8
9
10
Vout =
RU =
5.05
5.10
16.58
5.15
9.92
5.20
6.89
5.25
4.59
5.30
3.25
5.35
2.30
5.4
5.45
1.03
5.50
0.59
36.57
1.59
[%]
[VDC]
[kW]
Trim down
Vout =
RD =
1
2
3
4
5
6
7
8
9
10
4.95
4.90
4.85
4.80
8.152
4.75
5.66
4.70
3.999
4.65
2.812
4.60
1.922
4.55
1.23
4.50
0.676
45.533
20.612
12.306
RP40-xx12SFR
[%]
[VDC]
[kW]
Trim up
1
2
3
4
5
6
7
8
9
10
Vout =
RU =
12.12
12.24
165.95
12.36
98.636
12.48
64.977
12.60
44.782
12.72
31.318
12.84
21.701
12.96
14.488
13.08
8.879
13.20
4.391
367.91
[%]
[VDC]
[kW]
Trim down
Vout =
RD =
1
2
3
4
5
6
7
8
9
10
11.88
460.99
11.76
207.95
11.64
123.6
11.52
81.423
11.40
56.118
11.28
39.249
11.16
27.199
11.04
18.162
10.92
11.132
10.8
5.509
RP40-xx15SFR
[%]
[VDC]
[kW]
Trim up
1
2
3
4
5
6
7
8
9
10
Vout =
RU =
15.15
15.3
15.45
126.60
15.60
89.95
15.75
67.96
15.90
53.30
16.05
42.83
16.20
34.98
16.35
28.87
16.50
23.98
419.81
199.91
[%]
[VDC]
[kW]
Trim up
Vout =
RU =
11
12
13
14
15
16
17
18
19
20
16.650
19.98
16.800
16.65
16.950
13.83
17.100
11.42
17.250
9.32
17.400
7.49
17.550
5.87
17.700
4.43
17.850
3.15
18.000
1.99
[%]
[VDC]
[kW]
Trim down
Vout =
RD =
1
2
3
4
5
6
7
8
9
10
14.85
284.89
14.70
128.68
14.55
76.61
14.40
50.58
14.25
34.96
14.1
24.55
13.95
17.11
13.8
11.53
13.65
7.19
13.5
3.72
RP40-xx24SFR
[%]
[VDC]
[kW]
Trim up
1
2
3
4
5
6
7
8
9
10
Vout =
RU =
24.240
1275.2
24.480
606.60
24.720
383.73
24.960
272.30
25.200
205.44
25.440
160.87
25.680
129.03
25.920
105.15
26.160
86.58
26.400
71.72
[%]
[VDC]
[kW]
Trim up
Vout =
RU =
11
12
13
14
15
16
17
18
19
20
26.640
59.56
26.880
49.43
27.120
40.86
27.360
33.51
27.600
27.15
27.840
21.57
28.080
16.66
28.320
12.29
28.560
8.38
28.800
4.86
[%]
[VDC]
[kW]
Trim down
Vout =
RD =
1
2
3
4
5
6
7
8
9
10
23.760
838.15
23.520
376.78
23.280
222.98
23.040
146.09
22.800
99.95
22.560
69.19
22.320
47.22
22.080
30.74
21.840
17.93
21.600
7.68
www.recom-power.com
REV.: 8/2020
PD-4
RP40-FR
DC/DC Converter
Specifications (measured @ Ta= 25°C, nom. Vin, full load unless otherwise stated)
Series
ON/OFF CTRL
IIN
+Vin
+Vout
+Vin
+Vout
DC-DC ON
DC-DC OFF
Open or 3.0VDC < VCTRL < 12VDC
Short or 0VDC < VCTRL < 1.2VDC
Positve Logic
ICTRL
CTRL
-Vin
VCTRL
DC-DC ON
DC-DC OFF
Short or 0VDC < VCTRL < 1.2VDC
Open or 3.0VDC < VCTRL < 12VDC
-Vout
Negative Logic
-Vin
-Vout
REGULATIONS
Parameter
Condition
Value
1.0%
0.2%
Output Accuracy
Line Regulation
low line to high line, full load
Single
Dual
0.5%
1.0%
Load Regulation
Cross Regulation
0% to 100% load
asymmetrical 25%<>100% load
25% load step change
5.0%
Transient Response Recovery Time
250µs typ.
PROTECTIONS
Parameter
Condition
Value
Short Circuit Protection (SCP)
continuous, automatic recovery
3.3Vout
5Vout
12Vout
15Vout
24Vout
3.9VDC
6.2VDC
15VDC
20VDC
30VDC
Over Voltage Protection (OVP)
zener diode clamp
Over Load Protection (OLP)
% Iout rated
150% typ., Hiccup mode
115°C typ.
Over Temperature Protection (OTP)
I/P to O/P
I/P to O/P to Case
1.6kVDC/1min.
1.6kVDC/1min.
nom. Vin = 24, 48VDC
nom. Vin = 110VDC
Isolation Voltage(6)
I/P to O/P
I/P to O/P to Case
3kVDC/1min.
1.6kVDC/1min.
Isolation Resistance
Isolation Capacitance
Notes:
Viso= 500VDC
1GW min.
1500pF max.
Note6: For repeat Hi-Pot testing, reduce the time and/or the test voltage
Note7: Refer to local safety regulations if input over-current protection is also required. Recommended fuse: slow blow type
www.recom-power.com
REV.: 8/2020
PD-5
RP40-FR
DC/DC Converter
Specifications (measured @ Ta= 25°C, nom. Vin, full load unless otherwise stated)
Series
ENVIRONMENTAL
Parameter
Condition
Value
without derating
with derating
-40°C to +60°C
-40°C to +105°C
Operating Temperature Range
Maximum Case Temperature
Temperature Coefficient
+105°C
0.02%/ꢀ max.
without heat-sink
with heat-sink
10.8ꢀ/W
10.3ꢀ/W
Thermal Impedance
Operating Humidity
@ natural convection 0.1m/s
non-condensing
5% - 95% RH
Environmental testing Part 2-1: Tests
Test A: Cold
Storage temperature -40°C, 16 hours
Operating temperature -40°C, 2 hours
according to EN60068-2-1:2007
Environmental testing Part 2-2: Tests
Test B: Dry heat
Temperature +85°C, 6 hours
according to EN60068-2-2:2007
according to EN60068-2-30:2005
Temperature: +25 to +55°C
Humidity: 90%+/-5% RH
Test Duration: 48 hours
Environmental testing Part 2-30: Tests
Test Db: Damp heat, cyclic (12 h + 12 h cycle)
Random vibration test 5Hz to 150Hz, Z-Axis
1.01m/s² (0.103Grms), Y-Axis, X-Axis 0.70m/s²
(0.0714Grms), Duration 10min/Axis
Railway applications – Rolling stock equipment –
Shock and vibration tests
according to EN61373:2010
according to EN45545-2:2013
according to EN ISO 4589-2 OI
Fire protection on railway vehicles
Fire hazard testing Part 2-11: Glowing/hot-wire
based test methods – Glow-wire flammability test
method for end-products
Oxygen index test
Glow-wire test
Fire hazard testing Part 11-10: Test flames – 50 W
horizontal and vertical flame test methods
according to EN60695-2-11
Shock
according to MIL-STD-810F
according to MIL-STD-810F
according to MIL-STD-810F
907.3 x 103 hours
Thermal Shock
Vibration
MTBF
according to MIL-HDBꢀ-217F, G.B
Derating Graph (8)
(@ Chamber and natural convection 0.1m/s)
RP40-2415SFR-HC
RP40-2415SFR
100
80
60
40
20
0
100
80
60
40
20
0
-40
-20
0
20 40
60
80
100 120
105
-40 -20
0
20 40
60 80 100 120
65
105
Ambient Temperature [°C]
Ambient Temperature [°C]
Notes:
Note8: Derating graphs are valid only for the shown part numbers. If you need detailed derating-information about a part-number
not shown here please contact RECOM Techsupport for detailed information
www.recom-power.com
REV.: 8/2020
PD-6
RP40-FR
DC/DC Converter
Specifications (measured @ Ta= 25°C, nom. Vin, full load unless otherwise stated)
Series
SAFETY AND CERTIFICATIONS
Certificate Type (Safety)
Condition
Standard
UL60950-1, 2nd Edition, 2014
CAN/CSA-C22.2 No. 60950-1-07, 2nd Edition, 2014
Information Technology Equipment, General Requirements for Safety
E196683
Information Technology Equipment, General Requirements for Safety
(LVD)
IEC60950-1:2005, 2nd Edition + A2:2013
EN60950-1:2006 + A2:2013
TW1708011-001
Railway Applications - Electrical Equipment used on rolling stock
15A100702E-C
RU-AT.49.09571
EN50155:2007
TP TC 004/2011
EAC
RoHS2
RoHS-2011/65/EU + AM-2015/863
EMC Compliance (Railway)
Condition
Standard / Criterion
Railway Applications - Electromagnetic Compatibility
“refer to EMC filtering”
EN50121-3-2:2006
Industrial, Scientific and Medical Equipment – Radio Frequency
Disturbance Characteristics – Limits and Methods of Measurement
EN55011
Air 2, 4, 8kV
Contact 2, 4, 6kV
ESD Electrostatic Discharge Immunity Test
EN61000-4-2, Criteria A
Radiated, Radio-Frequency, Electromagnetic Field Immunity Test
Fast Transient and Burst Immunity (9)
20V/m (80-1000MHz)
DC Power Port: 2kV
EN61000-4-3, Criteria A
EN61000-4-4, Criteria A
DC Power Port: L-L 0.5, 1kV
DC Power Port: L-E 0.5, 1, 2kV
Surge Immunity (9)
EN61000-4-5, Criteria A
EN61000-4-6, Criteria A
Immunity to Conducted Disturbances, Induced by Radio-Frequency Fields
DC Power Port: 10V
EMC Compliance (Multimedia)
Condition
Standard / Criterion
Electromagnetic Compatibility of Multimedia Equipment - Emission
Requirements
with external filter
“refer to EMC filtering”
EN55032, Class A and B
Information Technology Equipment - Immunity Characteristics - Limits
and Methods of Measurement
EN55024:2010 + A1:2015
Air 2, 4, 8kV
Contact 2, 4, 6kV
ESD Electrostatic Discharge Immunity Test
IEC61000-4-2:2008, Criteria A
Radiated, Radio-Frequency, Electromagnetic Field Immunity Test
Fast Transient and Burst Immunity
20V/m (80-1000MHz)
DC Power Port: 2kV
IEC61000-4-3:2006 + A2:2010, Criteria A
IEC61000-4-4:2012, Criteria A
IEC61000-4-5:2014, Criteria A
IEC61000-4-6:2013, Criteria A
IEC61000-4-8:2009, Criteria A
Surge Immunity
DC Power Port: 0.5, 1, 2kV
DC Power Port: 10V
Immunity to Conducted Disturbances, Induced by Radio-Frequency Fields
Power Magnetic Field Immunity
50Hz 100A/m, 1000A/m
Notes:
Note9: An external input filter capacitor is required if the module has to meet EN61000-4-4 and -4-5.
The RP40-24xxFR requires an aluminum electrolytic capacitor (Nippon chemi-con ꢀY series, 220µF/100V) and a TVS (SMDJ58A,
58V, 3000Watt peak pulse power) connected in parallel.
The RP40-48xxFR requires an aluminum electrolytic capacitor (Nippon chemi-con ꢀY series, 220µF/100V) and a TVS
(SMDJ120A,120V, 3000Watt peak pulse power) connected in parallel.
The RP40-110xxFR requires 3pcs aluminum electrolytic capacitor in parallel (Ruby-con BXF series, 68µF/200V) and two TVS
(SMDJ90A, 90V, 3000Watt peak pulse power) in series, connected in parallel.
continued on next page
www.recom-power.com
REV.: 8/2020
PD-7
RP40-FR
DC/DC Converter
Specifications (measured @ Ta= 25°C, nom. Vin, full load unless otherwise stated)
Series
EMC Filtering according to EN50121-3-2 (Single Outputs)
C7
L1
+V
-V
IN
IN
TVS1(9)
TVS2(9)
C1(9)
C2
C3
C4
C6
C5
EMC Filtering according to EN50121-3-2 (Dual Outputs)
C7
L1
+V
-V
IN
TVS1(9)
TVS2(9)
C1(9)
C2
C3
C4
IN
C6
C5
Component List
MODEL
TVS1
TVS2
C1(9)
C2
C3
C4
C5, C6, C7
L1
SMDJ58A
58V, 3000W
peak pulse power
10µF/50V
1210 MLCC
2.2µH 11A
SMD-Inductor
RP40-24xxS_DFR
RP40-48xxS_DFR
RP40-110xxS_DFR
680pF/3kV
1808 MLCC
N/A
220µF/100V
N/A
N/A
SMDJ120A
120V, 3000W
peak pulse power
4.7µF/100V
1210 MLCC
12µH 4A
SMD-Inductor
SMDJ90A
90V, 3000W
peak pulse power peak pulse power
SMDJ90A
90V, 3000W
33µF/250V
Al Cap. (lie down)
Chemi-con ꢀXJ
1000pF
TDꢀ CD series
Y1
68µF/200V
3 in parallel
1µF/250V
1812 MLCC 1812 MLCC
1µF/250V
22µH 1.5A
SMD-Inductor
continued on next page
REV.: 8/2020
www.recom-power.com
PD-8
RP40-FR
DC/DC Converter
Specifications (measured @ Ta= 25°C, nom. Vin, full load unless otherwise stated)
Series
EMC Filtering according to EN55032 Class A (Single Outputs)
C8
L1
Fuse
+V
IN
IN
C2
C3
C4
C1
C5
-V
C7
C6
EMC Filtering according to EN55032 Class A (Dual Outputs)
C8
L1
Fuse
+V
IN
IN
C1
C2
C3
C4
C5
-V
C7
C6
Component List
MODEL
C1
C2
C3
C4
C5
C6
C7
C8
L1
10µF/50V
1210 MLCC
10µF/50V
1210 MLCC
2.2µH 11A
SMD Inductor
RP40-24xxS_DFR
680pF/3kV
1808 MLCC
N/A
N/A
N/A
4.7µF/100V
1210 MLCC
4.7µF/100V
1210 MLCC
12µH 4A
SMD Inductor
RP40-48xxS_DFR
33µF/250V
Al Cap. (lie down)
Chemi-con ꢀXJ
1000pF
TDꢀ CD series
Y1
1µF/250V
1812 MLCC
22µH 1.5A
SMD Inductor
RP40-110xxS_DFR
N/A
continued on next page
REV.: 8/2020
www.recom-power.com
PD-9
RP40-FR
DC/DC Converter
Specifications (measured @ Ta= 25°C, nom. Vin, full load unless otherwise stated)
Series
EMC Filtering according to EN55032 Class B (24Vin and 48Vin, Single Outputs)
C5
L1
L2
Fuse
+V
IN
C1
C2
C3
-V
IN
C7
C6
C4
EMC Filtering according to EN55032 Class B (24Vin and 48Vin, Dual Outputs)
C5
L1
L2
Fuse
+V
IN
C1
C2
C3
-V
IN
C7
C6
C4
Component List
MODEL
C1/C2
C3
C4/C6
C5/C7
L1/L2
10µF/50V
1210 MLCC
3.3µH 10A
SMD Inductor
RP40-24xxS_DFR
82µF/100V
Al Cap. (lie down)
Chemi-con ꢀJ
1000pf/3kV
1808 MLCC
2200pf/3kV
1808 MLCC
4.7µF/100V
1210 MLCC
12µH 4A
SMD Inductor
RP40-48xxS_DFR
continued on next page
REV.: 8/2020
www.recom-power.com
PD-10
RP40-FR
DC/DC Converter
Specifications (measured @ Ta= 25°C, nom. Vin, full load unless otherwise stated)
Series
EMC Filtering according to EN55032 Class B (110Vin Single Outputs)
C7
L1
L2
Fuse
+V
IN
C2
C1
C3
C4
C5
C6
-V
IN
C9
C8
EMC Filtering according to EN55032 Class B (110Vin Dual Outputs)
C7
L1
L2
Fuse
+V
IN
C2
C1
C3
C4
C5
C6
-V
IN
C9
C8
Component List
MODEL
C1
C2/C3
C4
C5/C6
C7/C8/C9
L1/L2
33µF/250V
Al Cap. (lie down)
Chemicon -ꢀXJ
33µF/250V
Al Cap. (lie down)
Chemicon -ꢀXJ
1µF/250V
1812 MLCC
1µF/250V
1812 MLCC
2200pF
TDꢀ CD series Y1
22µH 1.5A
SMD Inductor
RP40-110xxS_DFR
DIMENSIONS AND PHYSICAL CHARACTERISTICS
Parameter
Type
case
base
Value
copper alloy (CuZn33)
FR4 PCB
Material
potting
silicone (UL94 V-0)
50.8 x 25.4 x 10.2mm
56.8 x 25.4 x 16.8mm
without Heat-sink
with Heat-sink
Dimensions (LxWxH)
Weight
without Heat-sink
with Heat-sink
32g
43g
continued on next page
REV.: 8/2020
www.recom-power.com
PD-11
RP40-FR
DC/DC Converter
Specifications (measured @ Ta= 25°C, nom. Vin, full load unless otherwise stated)
Series
Dimension Drawing (mm)
Pinning Information
Pin #
Single
+Vin
-Vin
CTRL(3)
+Vout
-Vout
Trim
Dual
+Vin
-Vin
CTRL(3)
+Vout
Com
1
2
3
4
5
6
50.8
25.4
-Vout
Tolerance: xx.x= ±±.5mm
xx.xx= ±±.25mm
0.1
18 x 2.54= 45.72
2.5
Ø 1.0
Recommended Footprint Details
2.54
4
5
6
6
5
4
1
2
3
ꢃottom ꢁieꢂ
ꢀop ꢁieꢂ
2
1
3
Dimension Drawing with Heat-sink (mm)
50.8
Top View
Heat-sink
56.8
24.2
0.1
18 x 2.54= 45.72
2.54
Ø 1.0
PACKAGING INFORMATION
Parameter
Type
Value
tube
tray
without heat-sink
with heat-sink
255.0 x 54.0 x 22.0mm
302.5 x 222.0 x 20.0mm
Packaging Dimension (LxWxH)
tube
tray
without heat-sink
with heat-sink
9pcs
20pcs
Packaging Quantity
Storage Temperature Range
Storage Humidity
-55°C to +125°C
5% - 95% RH
non-condensing
The product information and specifications may be subꢀect to changes even without prior written notice.The product has been designed for various applicationsꢁ its suitability lies in the responsibility of each customer. The
products are not authorized for use in safety-critical applications without RECOMꢂs explicit written consent. A safety-critical application is an application where a failure may reasonably be expected to endanger or cause
loss of life, inflict bodily harm or damage property. The applicant shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized
use of RECOM products in such safety-critical applications.
www.recom-power.com
REV.: 8/2020
PD-12
相关型号:
©2020 ICPDF网 联系我们和版权申明