Industrial DC/DC CONVERTER  
MGDI-10 Standard Input : 10W POWER  
Industrial  
Grade  
2:1 Standard Input  
Single & Bi Outputs  
Metallic case - 1.500 VDC Isolation  
Low profile : 0,33 “ ( 8.5mm)  
• Nominal power of 10 W without derating  
• Wide temperature range : -40°C/+95°C case  
• High efficiency up to 83 %  
• Soft start  
• Galvanic isolation 1.500 VDC  
• Integrated LC EMI filter  
• Permanent short circuit protection  
• No optocoupler for high reliability  
1-General  
All the modules are designed with LC network  
filters to minimize reflected input current ripple  
and output voltage ripple according to EN55022  
and FCC Part 15J standard.  
The MGDI-10 series is a full family of DC/DC  
power modules designed for use in distributed  
power architecture and are particularly suitable  
for mobile or ground fixed applications in  
transportation, industry and télécommunication  
areas. These modules use a high frequency fixed  
switching technic at 480 KHz providing excellent  
reliability, low noise characteristics, high power  
density and a low profile package. Standard  
models are available with nominal input volta-  
ges as 5, 12, or 24 volts in range of 4,5-5,5 or  
18-36 volts. The series include single and bi  
output voltage choices of 3,3, 5, 12, 15, +/-5,  
+/-12 or +/-15 volts.  
The modules include a soft-start, an input  
undervoltage lock-out, a permanent short cir-  
cuit protection and an output overvoltage pro-  
tection to ensure efficient module protections.  
The soft-start allows current limitation and  
eliminates inrush current during start-up. The  
short circuit protection completely protects the  
modules against short-circuits of any duration  
by a shut-down and restores to normal when  
the overload is removed.  
5
The design has been carried out with surface  
mount components and is manufactured in a  
fully automated process to guarantee high  
quality. Each module is tested and burned in  
with a GAIA Converter automated test  
equipment.  
No external heatsink is required for the MGDI-  
10 series to supply 10W output power over the  
case temperature range of -40°C up to 95°C.  
The MGDI-10 series is designed in conformity  
with safety standards EN60950 and UL1950.  
2-Product Selection  
Single output model : MGDSI-10-  
Bi output model  
: MGDBI-10-  
Input Voltage Range  
Output  
Permanent  
B : 3.3 VDC  
C : 5 VDC or +/-5VDC  
E : 12 VDC or +/-12VDC  
F : 15 VDC or +/-15VDC  
C : 4,5-5,5 VDC  
I : 18-36 VDC  
REDEFINING THE SOURCE OF POWER  
For locations, phone, fax, E-Mail see back cover  
Gaia Converter FC97-006.03/06 Revision M  
©
Industrial  
Grade  
MGDI-10 Standard Input Series  
2- Product Selection (continued)  
Input range  
Output  
Current  
Reference  
Options  
4.5-5.5 VDC  
4.5-5.5 VDC  
4.5-5.5 VDC  
4.5-5.5 VDC  
4.5-5.5 VDC  
4.5-5.5 VDC  
4.5-5.5 VDC  
3,3 VDC  
5 VDC  
12 VDC  
2 A  
2 A  
0,80 A  
MGDSI-10-C-B  
MGDSI-10-C-C  
MGDSI-10-C-E  
MGDSI-10-C-F  
MGDBI-10-C-C  
MGDBI-10-C-E  
MGDBI-10-C-F  
/
/
/
/
/
/
/
15 VDC  
0,65 A  
+/- 5 VDC  
+/- 12 VDC  
+/- 15 VDC  
+/- 1 A  
+/- 0,40 A  
+/- 0,33 A  
18-36 VDC  
18-36 VDC  
18-36 VDC  
18-36 VDC  
18-36 VDC  
18-36 VDC  
18-36 VDC  
3,3 VDC  
5 VDC  
12 VDC  
2 A  
2 A  
0.80 A  
MGDSI-10-I-B  
MGDSI-10-I-C  
MGDSI-10-I-E  
MGDSI-10-I-F  
MGDBI-10-I-C  
MGDBI-10-I-E  
MGDBI-10-I-F  
/
/
/
/
/
/
/
15 VDC  
0.65 A  
+/- 5 VDC  
+/- 12 VDC  
+/- 15 VDC  
+/- 1 A  
+/- 0.40 A  
+/- 0.33 A  
Converter Selection Chart  
5
M G D S I - 10 - I - C  
Number of Outputs :  
S : single output  
B : bi output  
Input voltage range :  
C : 4.5-5.5 VDC  
I : 18-36VDC  
Output voltage :  
See table page 1  
2
Gaia Converter FC97-006.03/06 Revision M  
©
For locations, phone, fax, E-Mail see back cover  
Industrial  
Grade  
MGDI-10 Standard Input Series  
3- Electrical Specifications  
Data are valid at +25°C, unless otherwise specified.  
Single Output MGDSI- 10  
Limit or  
typical  
Parameter  
Conditions  
Units  
10 - C  
10 - I  
Input  
Nominal input voltage  
Full temperature range  
Full temperature range  
Nominal  
VDC  
VDC  
5
24  
Permanent input  
voltage range (Ui)  
Min. - Max.  
4,5- 5,5  
18- 36  
Undervoltage lock-out  
(UVLO)  
Minimum  
Maximum  
VDC  
VDC  
4
4,5  
16  
17,5  
turn-on/turn-off threshold  
Ui nominal  
Start up time  
Nominal output  
Full load : resistive  
Maximum  
Maximum  
ms  
30  
50  
30  
30  
Ui nominal, full load at switching freq. BW =  
20MHz  
Reflected ripple current  
mApp  
Decoupling capacitor 10µF  
Input current in short  
circuit mode (Average)  
Ui nominal  
Short-circuit  
Maximum  
Maximum  
mA  
mA  
50  
50  
30  
30  
Ui nominal  
No load  
No load input current  
Output  
Nominal  
Nominal  
Nominal  
Nominal  
VDC  
VDC  
VDC  
VDC  
3,3  
5
12  
15  
3,3  
5
12  
15  
Full temperature range  
Ui min. to max.  
75% load  
Output voltage *  
Ambient temperature : +25°c  
Ui nominal, 75% load  
Set Point accuracy  
Output power  
Maximum  
Maximum  
%
W
+/- 2  
10  
+/- 2  
10  
Full temperature range  
Ui min. to max.  
Output current  
3,3V output  
5V output  
12V output  
15V output  
Maximum  
Maximum  
Maximum  
Maximum  
A
A
A
A
2
2
0,80  
0,65  
2
2
0,80  
0,65  
5
Full temperature range  
Ui min. to max.  
Ripple output voltage **  
3,3V and 5V output  
12V output  
Ui nominal  
Full load  
BW = 20MHz  
Maximum  
Maximum  
Maximum  
mVpp  
mVpp  
mVpp  
50  
100  
150  
50  
100  
150  
15V output  
Ui min. to max.  
Full load  
Line regulation  
Load regulation ***  
Efficiency  
Maximum  
Maximum  
Typical  
%
%
%
+/- 1  
+/- 2,5  
77  
+/- 1  
+/- 2,5  
83  
Ui nominal  
25% to full load  
Ui nominal  
Full load  
Maximum admissible  
Capacity load  
3,3V and 5V output  
12V and 15V output  
Ui nominal  
Full load  
Per output  
Maximum  
Maximum  
µF  
µF  
1.000  
330  
1.000  
330  
Note * : For proper operation the MGDI-10 module requires to install a 22µF chemical or tantalum capacitance accross output terminals.  
Note ** : The ripple output voltage is the periodic AC component imposed on the output voltage, an aperiodic and random component (noise) has also to be considered.  
This noise can be reduced by adding an external capacitor (typically 10nF/rated voltage depending on isolation requirement) connected between the pin Gin and the  
pin Gout of the converter. This capacitor should be layed-out as close as possible from the converter.  
Note *** : For load regulation characteristics from 0% to full load, please contact factory.  
3
Gaia Converter FC97-006.03/06 Revision M  
©
For locations, phone, fax, E-Mail see back cover  
Industrial  
Grade  
MGDI-10 Standard Input Series  
3- Electrical Specifications (continued)  
Data are valid at +25°C, unless otherwise specified.  
Bi Output MGDBI- 10  
Limit or  
typical  
Parameter  
Conditions  
Units  
10 - C  
10 - I  
Input  
Nominal input voltage  
Full temperature range  
Full temperature range  
Nominal  
VDC  
VDC  
5
24  
Permanent input  
voltage range (Ui)  
Min. - Max.  
4,5- 5,5  
18- 36  
Undervoltage lock-out  
(UVLO)  
Minimum  
Maximum  
VDC  
VDC  
4
4,5  
16  
17,5  
turn-on/turn-off threshold  
Ui nominal  
Start up time  
Nominal output  
Full load : resistive  
Maximum  
Maximum  
ms  
30  
50  
30  
30  
Ui nominal, full load at switching freq. BW =  
20MHz  
Reflected ripple current  
mApp  
Decoupling capacitor 10µF  
Input current in short  
circuit mode (Average)  
Ui nominal  
Short-circuit  
Maximum  
Maximum  
mA  
mA  
50  
50  
30  
30  
Ui nominal  
No load  
No load input current  
Output  
Full temperature range  
Ui min. to max.  
75% load  
Nominal  
Nominal  
Nominal  
VDC  
VDC  
VDC  
+/- 5  
+/- 12  
+/- 15  
+/- 5  
+/- 12  
+/- 15  
Output voltage *  
Ambient temperature : +25°c  
Ui nominal, 75% load  
Set Point accuracy  
Output power  
Maximum  
Maximum  
%
W
+/- 2  
+/- 5  
+/- 2  
+/- 5  
Full temperature range  
Ui min. to max.  
Output current  
+/- 5V output  
+/- 12V output  
+/- 15V output  
Maximum  
Maximum  
Maximum  
A
A
A
+/- 1  
+/- 0,40  
+/- 0,33  
+/- 1  
+/- 0,40  
+/- 0,33  
Full temperature range  
Ui min. to max.  
5
Ripple output voltage **  
5V output  
12V output  
Ui nominal  
Full load  
BW = 20MHz  
Maximum  
Maximum  
Maximum  
mVpp  
mVpp  
mVpp  
50  
100  
150  
50  
100  
150  
15V output  
Ui min. to max.  
Full load  
Line regulation  
Maximum  
Maximum  
%
%
+/- 1  
+/- 1  
Ui nominal  
25% to full load  
Load regulation ***  
+/- 2,5  
+/- 2,5  
Ui nominal  
+ Vout nominal load  
- Vout from 25% to full load  
Cross load output  
regulation  
Maximum  
Typical  
%
%
+/- 0,5  
77  
+/- 0,5  
83  
Ui nominal  
Full load  
Efficiency  
Maximum admissible  
Capacity load  
3,3V and 5V output  
12V and 15V output  
Ui nominal  
Full load  
Per output  
Maximum  
Maximum  
µF  
µF  
470  
100  
470  
100  
Note * : For proper operation the MGDI-10 module requires to install a 22µF chemical or tantalum capacitance accross output terminals.  
Note ** : The ripple output voltage is the periodic AC component imposed on the output voltage, an aperiodic and random component (noise) has also to be considered.  
This noise can be reduced by adding an external capacitor (typically 10nF/rated voltage depending on isolation requirement) connected between the pin Gin and the  
pin Gout of the converter. This capacitance should be layed-out as close as possible from the converter.  
Note *** : For load regulation characteristics from 0% to full load, please contact factory.  
4
Gaia Converter FC97-006.03/06 Revision M  
©
For locations, phone, fax, E-Mail see back cover  
Industrial  
Grade  
MGDI-10 Standard Input Series  
4- Switching Frequency  
Parameter  
Conditions  
Limit or typical  
Specifications  
Full temperature range  
Ui min. to max.  
Switching frequency  
Nominal, fixed  
480 KHz  
No load to full load  
5- Isolation  
Parameter  
Conditions  
Limit or typical  
Specifications  
Electric strength test voltage  
Input to output  
Minimum  
1.500 VDC / 1 min  
Electric strength test voltage between  
outputs (for dual and triple outputs)  
Output to output  
500 VDC  
Minimum  
Minimum  
No isolation  
100 MOhm  
Isolation resistance  
6- Protection Functions  
Characteristics  
Protection Device  
Recovery  
Limit or typical  
Specifications  
Turn-on, turn-off circuit  
with no hysteresis  
Automatic  
recovery  
Input undervoltage lock-out (UVLO)  
Threshold  
Permanent  
See section 3  
See section 11  
Hiccup circuitry with  
auto-recovery  
Automatic  
recovery  
Output short circuit protection (SCP)  
Output overvoltage protection (OVP)  
5
Maximum  
Maximum  
Maximum  
Maximum  
For 3.3v : 4v  
For 5v : 6v  
For 12v : 14v  
For 15v : 17v  
Zener clamp  
/
7- Reliability Data  
Characteristics  
Conditions  
Temperature  
Specifications  
Case at 40°C  
Case at 70°C  
950.000 Hrs  
380.000 Hrs  
Ground fixed (Gf)  
Mean Time Between Failure (MTBF)  
According to MIL-HDBK-217F  
Case at 40°C  
Case at 70°C  
240.000 Hrs  
105.000 Hrs  
Ground mobile (Gm)  
Telecom switchers  
Mean Time Between Failure (MTBF)  
According to IEC-62380-TR  
/
Consult factory  
5
Gaia Converter FC97-006.03/06 Revision M  
©
For locations, phone, fax, E-Mail see back cover  
Industrial  
Grade  
MGDI-10 Standard Input Series  
8- Electromagnetic Interference  
Electromagnetic interference requirements according to EN55022 class A and class B can be easily achieved as  
indicated in the following table :  
Electromagnetic Interference according to EN55022  
Configuration  
With common mode capacitor  
Cc = 10nF and input capacitor C i  
With common mode capacitor  
C C = 10nF and external filter  
Models  
4,5-5,5V input models  
18-36V input models  
Configuration  
Conducted noise  
emission  
Class A, C i =10µF/ 35 V tantalum  
Class A, C i =4.7µF / 50 V tantalum  
Class B  
Class B  
With common mode capacitor C c = 10 nF  
Radiated noise  
emission  
Models  
All models  
Class B  
8-1 Module Compliance with EN55022 class A Standard  
Electromagnetic interference requirements according  
to EN55022 class A can be easily achieved by adding  
an external input capacitance (CI Value explained in  
previous table) and a common mode noise capacitance  
Cc (10 nF/rated voltage depending on isolation  
requirement) connected between Gin and Gout. This  
common mode noise capacitance Cc should be layed-  
out as close as possible from the DC/DC converter.  
+ Input  
Vi  
MGDI - Series  
Go  
Gi  
Vo  
Input capacitance C  
i
- Input  
5
Common mode noise capacitance C = 10nF  
c
8-2 Module Compliance with EN 55022 Class B Standard  
Electromagnetic interference requirements according to  
EN55022 class B can be easily achieved by adding an  
external input filter consisting of 4 capacitances, a  
common mode choke, and a differential  
mode inductance, together with a common mode noise  
capacitance (10 nF/rated voltage depending on isola-  
tion requirement) connected between Gin and Gout.  
Please consult EN55022 Class B EMI Filter design dote  
for further details.  
L1  
L2  
C3  
C2  
Vi  
+ Input  
Vo  
C1  
MGDI - Series  
- Input  
Go  
Gi  
C4  
Common mode noise capacitance C = 10nF  
c
6
Gaia Converter FC97-006.03/06 Revision M  
©
For locations, phone, fax, E-Mail see back cover  
Industrial  
Grade  
MGDI-10 Standard Input Series  
9- Thermal Characteristics  
Characteristics  
Conditions  
Limit or typical  
Performances  
Operating ambient temperature  
range at full load  
Minimum  
Maximum  
- 40°C  
+ 71°C  
Ambient temperature *  
Case temperature  
Operating case temperature  
range at full load  
Minimum  
Maximum  
- 40°C  
+95°C  
Minimum  
Maximum  
- 40°C  
+ 105°C  
Storage temperature range  
Thermal resistance  
Non functionning  
Rth case to ambient in free air  
natural convection  
Typical  
12°C /W  
Note * : The upper temperature range depends on configuration, the user must assure a max. case temperature of + 95°C.  
The MGDI-10 series operating case temperature must not exceed 95°C. The maximum ambient temperature admissible for  
the DC/DC converter corresponding to the maximum operating case temperature of 95°C depends on the ambient airflow,  
the mounting/orientation, the cooling features and the power dissipated.  
To calculate a maximum admissible ambient temperature the following method can be used. Knowing the maximum case  
temparature Tcase = 95°C of the module, the power used Pout and the efficiency η :  
• determine the power dissipated by the module Pdiss that should be evacuated :  
Pdiss = Pout(1/η - 1)  
• determine the maximum ambient temperature :  
Ta = 95°C - Rth x Pdiss  
where Rth is the thermal resistance from the case to ambient.  
The previous thermal calculation shows two areas of operation :  
• a normal operation area in a free natural ambient convection (grey area in this following graph),  
• an area with cooling features (air flow or heatsink) ensuring a maximum case temperature below the maximum  
operating case temperature of 95°C (white area in the following graph).  
5
Power (W)  
100%  
Additionnal cooling operation area  
75%  
Natural convection operation area  
50%  
25%  
10 20 30 40 50  
60 70  
80 90 100  
Temperature (˚C)  
Full load ambient temperature without derating : 71˚C  
Maximum case temperature : 95˚C  
Maximum storage temperature : 105˚C  
7
Gaia Converter FC97-006.03/06 Revision M  
©
For locations, phone, fax, E-Mail see back cover  
Industrial  
Grade  
MGDI-10 Standard Input Series  
10- Environmental Qualifications  
The modules have been subjected to the following environmental qualifications.  
Characteristics  
Conditions  
Severity  
Test procedure  
Climatic Qualifications  
Duration  
Temperature  
Status of unit  
1.000 Hrs  
95°C case  
unit operating  
Life at high  
temperature  
IEC 68-2-2  
Damp heat  
Temperature  
Duration  
93 % relative humidity  
40°C  
56 days  
IEC 68-2-3  
Test Ca  
Humidity steady  
Status of unit  
unit not operating  
Number of cycles  
Temperature change  
Transfert time  
Steady state time  
Status of unit  
200  
-40°C / +71°C  
40 min.  
20 min.  
unit not operating  
Temperature  
cycling  
IEC 68-2-14  
Test N  
Number of shocks  
Temperature change  
Transfert time  
Steady state time  
Status of unit  
50  
-40°C / +105°C  
10 sec.  
20 min.  
Temperature  
shock  
IEC 68-2-14  
Test Na  
unit not operating  
Mechanical Qualifications  
Number of cycles  
10 cycles in each axis  
10 to 60 Hz / 0.7 mm  
60 to 2000 Hz / 10 g  
0.7 mm/10 g  
2h 30 min. per axis  
unit not operating  
Frequency : amplitude  
Frequency : acceleration  
Amplitude /acceleration  
Duration  
IEC 68-2-6  
Test Fc  
Vibration  
(Sinusoidal)  
Status of unit  
Number of shocks  
Peak acceleration  
Duration  
Shock form  
Status of unit  
3 shocks in each axis  
100 g  
6 ms  
1/2 sinusoidal  
unit not operating  
Shock  
(Half sinus)  
IEC 68-2-27  
Test Ea  
5
Number of bumps  
Peak acceleration  
Duration  
2000 bumps in each axis  
25 g  
6 ms  
Bump  
(Half sinus)  
IEC 68-2-29  
Test Eb  
Status of unit  
unit not operating  
Electrical Immunity Qualifications  
Number of discharges  
Air discharge level  
10 positive & 10 negative discharges  
4 kV : sanction A  
Electrical  
discharge  
susceptibility  
EN55082-2 with :  
EN61000-4-2  
IEC 801-2  
Contact discharge level  
Air discharge level  
2 Kk : sanction A  
8 Kk : sanction B  
Contact discharge level  
4 kV : sanction B  
Antenna position  
Electromagnetic field  
Wave form signal  
Frequency range  
at 1 m  
10 V/m  
AM 80%, 1 kHz  
26 MHz to 1 GHz  
EN55082-2 with :  
EN61000-4-3  
IEC801-3  
Electrical field  
susceptibility  
Burst form  
Wave form signal  
Impedance  
Level 1  
5/50 ns  
Electrical fast  
transient  
susceptibility  
5 kHz with 15 ms burst duration period 300 ms  
50 Ohm  
0,5 kV : sanction A  
EN55082-2 with :  
EN61000-4-4  
IEC801-4  
Level 3  
2 kV : sanction B  
8
Gaia Converter FC97-006.03/06 Revision M  
©
For locations, phone, fax, E-Mail see back cover  
Industrial  
Grade  
MGDI-10 Standard Input Series  
11- Description of Protections  
11-1 Input Undervoltage Lock-out (UVLO)  
On  
The input undervoltage lock-out protection device turns-  
on and turns-off the output voltage when the input bus  
voltage reaches the undervoltage lock-out threshold. There  
is no hysteresis cycle at turn-on and turn-off.  
Off  
Vin  
UVLO  
Turn-on/Turn-off  
Vo (%)  
11-2 Output Short Circuit Protection (SCP)  
100  
The short circuit protection device protects the module  
against short circuit of any duration and restores the mo-  
dule to normal operation when the short circuit is removed.  
It operates in «hiccup» mode by testing periodically if an  
overload is applied (typically every 200ms recovery time).  
The overload detection threshold is typically 200% of maxi-  
mum current with a detection time lower than 5ms.  
detection time  
recovery time  
x
time  
recovery time  
11-3 Output Overvoltage Protection (OVP)  
The output overvoltage protection device protects external  
components against high voltage or possible overvoltages  
which can be supplied by the module (i.e in case of internal  
failure). It consists of a zener diode clamping the output  
voltage; under worst case conditions this zener diode will  
short-circuit.  
The output voltage protection is not designed to withstand  
externally applied output overvoltages to protect the mo-  
dule itself.  
5
9
Gaia Converter FC97-006.03/06 Revision M  
©
For locations, phone, fax, E-Mail see back cover  
Industrial  
Grade  
MGDI-10 Standard Input Series  
12- Application Notes  
12-1 Connection of Outputs in Series  
Any of the bi output converters can be configured to produce  
an output of 10V (+/-5 output models), 24V (+/-12V out-  
put models), or 30V (+/-15V output models) by connecting  
the load across the output (+) and the output (-) with  
either output grounded, and leaving the common pin  
floating.  
VI  
GI  
+Vo  
Go  
2 x Vo  
-Vo  
12-2 Connection of Modules in Series  
VI  
Vo  
The output of single output units can be connected in  
series without any precautions to provide higher output  
voltage level.  
Nevertheless, GAIA Converter recommends to protect each  
individual output by a low power shottky diode rated with  
the maximum current of the converter to avoid reverse  
polarity at any output.  
Reverse polarity may occur at start up if the output volta-  
ges do not rise at the same time.  
GI  
VI  
Go  
Vo  
2 x Vo  
GI  
Go  
5
12-3 Connection of Modules in Parallel  
Several converters with equal output voltage can be  
connected in parallel to increase power. Nevertheless some  
cares have to be taken in particular as the output voltage  
of each converter is slightly different, when paralleling,  
the converter with the highest output voltage will source  
the most current.  
However the GAIA Converter modules are designed with a  
soft’’ output voltage versus current characteristic. This  
causes the output voltage of each converter to automatically  
adjust downward as its current increases so each converter  
very approximately shares the total output current. It is  
important that each converter has approximately the same  
impedance between their output and the common load.  
VI  
Vo  
Vo  
GI  
VI  
Go  
Vo  
GI  
Go  
10  
Gaia Converter FC97-006.03/06 Revision M  
©
For locations, phone, fax, E-Mail see back cover  
Industrial  
Grade  
MGDI-10 Standard Input Series  
13- Dimensions  
Dimensions are given in mm (inches). Tolerance : +/- 0,2 mm (+/- 0.01 ) unless otherwise indicated.  
Weight : 20 grams (0.7 Ozs) max.  
40  
(1.58")  
26  
(1.03")  
7,60  
(0.30")  
8
(0.32")  
5 min  
(0.20")  
10,16  
26,20  
(0.40")  
(1.03")  
20,32  
(0.80")  
35.56  
(1,40")  
Pin dimensions : O 0,73 mm (0.03 )  
Metallic case black anodized coating  
Matte tin plating finished pin  
14- Product Marking  
Upper face : Company logo, location of manufacturing.  
Side face : Module reference, option, date code : year and week of manufacturing.  
5
15- Connections  
Pin  
1
Bi Output  
Single Output  
+ Input (Vi)  
No pin  
4
5
6
+ Input (Vi)  
No pin  
2
3
- Input (Gi)  
Output + (+Vo)  
Common (Go)  
Output - (-Vo)  
- Input (Gi)  
Output (Vo)  
No pin  
4
5
6
Common (Go)  
1
2
3
Bottom view  
11  
Gaia Converter FC97-006.03/06 Revision M  
©
For locations, phone, fax, E-Mail see back cover  
For more detailed specifications and applications information, contact :  
International Headquarters  
Marketing and Sales department  
GAÏA Converter - France  
North American Headquarters  
GAÏA Converter Canada, Inc  
Address : 6611 Thimens  
ST-LAURENT, QUEBEC - CANADA H4S 1W2  
Tel. : (514)-333-3169  
Address : B.P. 14 - MERIGNAC - FRANCE  
Tel. : + (33)-5-57-92-12-80  
Fax : + (33)-5-57-92-12-89  
Fax : (514)-333-4519  
Represented by :  
Information given in this datasheet is believed to be accurate and reliable. However, no responsibility is assumed for the consequence of its use nor for any infringement of patents or other rights of third parties which may result from its use.  
These products are sold only according to GAIA Converter general conditions of sale, unless otherwise confirmed by writing. Specifications subject to change without notice.  

相关型号:

MGDM-04

Hi-Rel DC/DC CONVERTER
ETC

MGDM-10

Hi-Rel DC/DC CONVERTER 10W POWER
ETC

MGDM-150

Hi-Rel DC/DC CONVERTER
ETC

MGDM-75

Hi-Rel DC/DC CONVERTER 75W POWER
ETC

MGDM10

Hi-Rel DC/DC CONVERTER 10W POWER
ETC

MGDQ01

Power RF Amplifiers
POLYFET

MGDS-04-C-B

Hi-Rel DC/DC CONVERTER
ETC

MGDS-04-C-B-S

Hi-Rel DC/DC CONVERTER
ETC

MGDS-04-C-B-T

Hi-Rel DC/DC CONVERTER
ETC

MGDS-04-C-B/S

Hi-Rel DC/DC CONVERTER
ETC

MGDS-04-C-B/T

Hi-Rel DC/DC CONVERTER
ETC

MGDS-04-C-BS

Hi-Rel DC/DC CONVERTER
ETC