G7S-3A3B-DC24 [ETC]

;
G7S-3A3B-DC24
型号: G7S-3A3B-DC24
厂家: ETC    ETC
描述:

文件: 总6页 (文件大小:87K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
R
Plug-in Safety Relay  
G7S  
Safety Relay for Machine Control  
Conforms to EN Standard  
H Suitable for safety circuits in press  
machinery, machine tools, and other  
production machinery  
H CE mark (conforms to prEN50205)  
H Positive, force-guided contacts  
H A minimum of 0.5 mm between contacts  
even when one contact is welded  
(prEN50205 Class A)  
H DIN rail-mounting and panel-mounting  
sockets are available  
Note: Be sure to refer to the Precautions section.  
Ordering Information  
J SAFETY RELAYS  
Number of contacts NO contacts NC contacts Contact form  
Rated voltage (V) Part number  
24 VDC  
G7S-4A2B DC24  
6 poles  
4
3
2
3
4PST-NO + DPST-NC  
3PST-NO + 3PST-NC  
G7S-3A3B DC24  
J ACCESSORIES  
Description  
Part number  
P7S-14F  
P7S-14A  
P7S-14P  
P7S-A10  
P7S-B  
Mounting sockets  
DIN-rail mounting and screw mounting  
Solder terminals  
PCB terminals  
Socket mounting plate  
Relay removal tool  
For solder terminal sockets, holds 10 sockets  
Removes relay from sockets  
50 cm (1.64 ft) length  
1 m (3.28 ft) length  
DIN rail mounting track  
PFP-50N  
PFP-100N  
PFP-S  
Spacer  
End plate  
PFP-M  
G7S  
G7S  
Specifications  
J RATINGS  
Operation Coil  
Rated voltage Rated current Coil resistance Minimum operate voltage Release voltage Max. voltage Power consumption  
24 VDC 30 mA 800 80% max. (V) 10% (V) 110% (V) Approx. 0.8 W  
Note: 1. The rated current and coil resistance are measured at a coil temperature of 23°C with tolerances of ±15%.  
2. Performance characteristics are based on a coil temperature of 23°C  
3. The maximum voltage is based on an ambient operating temperature of 23°C maximum.  
Switching Section (Contact Ratings)  
Load type  
Resistive load (cos φ =1)  
240 VAC: 3 A, 24 VDC: 3 A  
250 VAC, 24 VDC  
6 A  
Inductive load (cos φ = 0.4, L/R = 7 ms)  
Rated load  
240 VAC: 3 A, 24 VDC: 1 A  
Maximum switching voltage  
Maximum switching current  
Maximum switching capacity (reference value)  
1,440 VA, 144 W  
5 VDC, 10 mA  
Min. permissible load  
(See note.)  
Contact material  
Ag ) Au  
Note: The above values are based on an operating frequency of 60 operations/min.  
J CHARACTERISTICS  
Contact resistance (See Note 2.)  
Operate time (See Note 3.)  
Release time (See Note 3.)  
Maximum operating frequency  
100 mmax.  
50 ms max.  
50 ms max.  
Mechanical  
Rated load  
18,000 operations/hr  
1,800 operations/hr  
100 Mmin. (at 500 VDC)  
Insulation resistance  
Dielectric strength  
Vibration  
2,500 VAC, 50/60 Hz for 1 min (1,500 VAC between contacts of same polarity)  
10 to 55 Hz, 1.5-mm double amplitude  
Mechanical  
Electrical  
Mechanical  
Electrical  
Mechanical  
Electrical  
Operating  
Storage  
10 to 55 Hz, 0.75-mm double amplitude  
2
Shock  
1,000 m/s (approx. 100G)  
2
100 m/s (approx. 10G)  
Life expectancy  
Ambient temperature  
10,000,000 operations min. (at approx. 18,000 operations/hr)  
100,000 operations min. (at the rated load and approx. 1,800 operations/hr)  
–10°C to 70°C (14°F to 158°F) no icing  
–25°C to 70°C (-13°F to 158°F) no icing  
35% to 85% RH  
Relative humidity  
Ambient storage humidity  
Weight  
35% to 85% RH  
Approx. 65 g  
Note: 1. The values given above are initial values.  
2. Measurement conditions: 5 VDC, 10 mA, voltage drops.  
3. Measurement conditions:  
Rated voltage operation  
Ambient operating temperature: 23°C (73.4°F)  
Does not include bounce time.  
2
G7S  
G7S  
J CHARACTERISTICS OF SAFETY RELAY SOCKET  
Model  
Continuous current  
6 A  
Dielectric strength  
Insulation resistance  
P7S-14j  
2000 VAC for 1 min. between terminals  
1000 Mmin. (See note.)  
Note: Measurement conditions: Measurement of the same points as for the dielectric strength at 500 VDC.  
J APPROVED STANDARDS  
VDE0435 (Electrical Relays); Approved by VDE  
IEC255 (Electrical Relays); Approved by VDE  
prEN50205 (Electrical Relays); Approved by VDE  
UL508 (Industrial Control Device)  
CSA22.2 No.14 (Industrial Control Device)  
Engineering Data  
J ELECTRICAL LIFE EXPECTANCY  
(240 VAC; cosφ=0.4, cosφ=1)  
100  
10  
G7S  
G9S  
1
0
1
2
3
4
5
6
I (Current)  
Switching current (A)  
Dimensions  
Unit: mm (inch)  
J SAFETY RELAYS  
G7S-4A2B  
G7S-3A3B  
Terminal Installation/Internal  
Connection Diagram  
(Bottom View)  
62 max.  
(2.44)  
22.5 max.  
(0.89)  
G7S-4A2B  
24 VDC  
37 max.  
(1.46)  
5 min.  
24 VDC  
3
G7S  
G7S  
J SAFETY RELAY SOCKETS  
P7S-14F DIN Rail-mounting Socket or Screw Mounting  
7.5  
4
Terminal Installation/Internal  
Connection Diagram  
(Top View)  
7 x 4 = 28  
40 max.  
31.3  
47 max.  
(1.85)  
Cross-section of  
Mounting Holes  
90.5 max.  
(3.56)  
40 max.  
(1.57)  
With Safety Relay Mounted  
69 max.  
(2.72)  
47 max.  
P7S-14A Panel-mounting Socket  
(Solder Terminals)  
61.5 max.  
(2.42)  
Terminal Installation/Internal  
23 max.  
(0.91)  
Connection Diagram  
(Bottom View)  
G7S-4A2B  
33 max.  
(1.30)  
Cross-section of  
Mounting Holes  
(0.83)  
G7S-3A3B  
With Safety Relay Mounted  
(2.24)  
39 max.  
(1.54)  
4
G7S  
G7S  
P7S-14P PCB-mounting Socket  
(PCB Terminals)  
61.5 max.  
(2.42)  
Terminal Installation/Internal  
Connection Diagram  
(Bottom View)  
23 max.  
(0.91)  
G7S-4A2B  
Two, 6.5 dia x 7.9 deep  
Cross-section of  
Mounting Holes  
29 max.  
(1.14)  
G7S-3A3B  
23 max.  
With Safety Relay Mounted  
Two,  
3.6 dia.  
Fourteen, 1.8 dia.  
28 max.  
(1.10)  
15.4 (0.61)  
J SOCKET MOUNTING PLATE  
P7S-A10 (Special Mounting Plate for P7S-14A)  
261 max.  
(10.28)  
Four, C0.5  
81 max.  
(3.19)  
1.6 (0.06)  
J RELAY REMOVAL TOOL  
P7S-B  
59.2  
(2.33)  
19.3  
35  
(1.38)  
7
15  
(0.59)  
5
G7S  
G7S  
Precautions  
Safety Relays  
A Safety Relay is a relay with which a safety circuit can be  
J POSITIVE GUIDED CONTACTS  
When NO contacts are welded, the coil will be non-energized so  
all NC contacts will maintain a distance between the contacts of  
0.5 mm minimum. Likewise if NC contacts are welded, the coil  
will be energized so all contacts will maintain a distance between  
each other of 0.5 mm minimum.  
configured. For common precautions when using and handling  
relays, consult Omron.  
Contacts  
The coil terminals have polarity (positive and negative).Operation  
is not possible if these are connected in reverse.  
! Caution  
Do not touch the terminal area of the Relays or the socket ter-  
minal area (charged area) while power is ON. Electric shock  
will result.  
NOTE: DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters to inches divide by 25.4.  
R
OMRON ELECTRONICS, INC.  
One East Commerce Drive  
Schaumburg, IL 60173  
OMRON CANADA, INC.  
885 Milner Avenue  
Scarborough, Ontario M1B 5V8  
1-800-55-OMRON  
416-286-6465  
Cat. No. CEDSAX3  
10/99  
Specifications subject to change without notice.  
Printed in U.S.A.  

相关型号:

G7S-3A3B-E

Relays with Forcibly Guided Contacts and High Switching Capacity of 10A
OMRON

G7S-3A3BDC24

Plug-In Safety Relay
OMRON

G7S-4A2B

Power/Signal Relay, 6PST, Momentary, 0.03A (Coil), 24VDC (Coil), 800mW (Coil), 6A (Contact), 24VDC (Contact), DC Input, AC/DC Output, Socket Mount,
OMRON

G7S-4A2B-E

Relays with Forcibly Guided Contacts and High Switching Capacity of 10A
OMRON

G7S-4A2B-E-DC24

Relays with Forcibly Guided Contacts and High Switching Capacity of 10A
OMRON

G7S-4A2BDC24

Plug-In Safety Relay
OMRON

G7S3

Silicon Power Rectifiers
EDAL

G7SA

Relays with Forcibly Guided Contacts
ETC

G7SA-2A2B

Compact, Slim Relays Conforming to EN Standards
OMRON

G7SA-2A2B110VDC

Power/Signal Relay, 4PST, Momentary, 0.004A (Coil), 110VDC (Coil), 420mW (Coil), 6A (Contact), 125VDC (Contact), DC Input, AC/DC Output, Through Hole-Straight Mount,
OMRON

G7SA-2A2B12VDC

Power/Signal Relay, 4PST, Momentary, 0.03A (Coil), 12VDC (Coil), 360mW (Coil), 6A (Contact), 125VDC (Contact), DC Input, AC/DC Output, Through Hole-Straight Mount,
OMRON