G7S-3A3B-E [OMRON]

Relays with Forcibly Guided Contacts and High Switching Capacity of 10A; 继电器带强制导向触点和10A的高开关容量
G7S-3A3B-E
型号: G7S-3A3B-E
厂家: OMRON ELECTRONICS LLC    OMRON ELECTRONICS LLC
描述:

Relays with Forcibly Guided Contacts and High Switching Capacity of 10A
继电器带强制导向触点和10A的高开关容量

开关 继电器
文件: 总5页 (文件大小:469K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Relays with Forcibly Guided Contacts  
G7S-@-E  
Relays with Forcibly Guided  
Contacts and High Switching  
Capacity of 10A  
CSM_G7S-_-E_DS_E_5_1  
• Relays with forcibly guided contacts  
(EN50205 Class A, certified by VDE).  
• Supports the CE marking of machinery (Machinery  
Directive).  
• Helps avoid hazardous machine status when used as part  
of an interlocking circuit.  
• Track-mounting and Back-mounting Sockets are  
available.  
For the most recent information on models that have been certified for  
safety standards, refer to your OMRON website.  
Be sure to read the “Safety Precautions” on page 4 and the  
“Precautions for All Relays with Forcibly Guided Contacts”.  
Model Number Structure  
Model Number Legend  
G7S-@A@B-E  
1
2
1. NO Contact Poles  
4: 4PST-NO  
2. NC Contact Poles  
2: DPST-NC  
3: 3PST-NO  
3: 3PST-NC  
Ordering Information  
Relays with Forcibly Guided Contacts  
Type  
Poles  
Contact configuration  
Rated voltage  
Model  
4PST-NO, DPST-NC  
3PST-NO, 3PST-NC  
G7S-4A2B-E  
G7S-3A3B-E  
Standard  
6 poles  
24 VDC  
Sockets  
Type4  
Rated voltage  
24 VDC  
---  
Model  
Track-mounting  
Back-mounting  
Common for track mounting and screw mounting  
PCB terminals  
P7S-14F-END  
P7S-14P-E  
Specifications  
Ratings  
Coil  
Item  
Rated current  
(mA)  
Coil resistance  
Max. voltage  
(V)  
Power consumption  
(W)  
Rated voltage  
(Ω)  
24 VDC  
30  
800  
110%  
Approx. 0.8  
Note: 1. The rated current and coil resistance are measured at a coil temperature of 23°C with tolerances of ±15%.  
2. The maximum voltage is based on an ambient operating temperature of 23°C maximum.  
1
G7S-@-E  
Contacts  
Item  
Load  
Resistive load  
10 A at 250 VAC  
10 A at 30 VDC  
NO contact  
NC contact  
Rated load  
6 A at 250 VAC  
6 A at 30 VDC  
NO contact  
NC contact  
10 A  
Rated carry current  
6 A  
250 VAC, 30 VDC  
10 A  
Maximum switching voltage  
Maximum switching current  
NO contact  
NC contact  
6 A  
G7S-@-E Characteristics of Sockets  
Model  
P7S-14F-END  
P7S-14P-E  
C o n t i n u o u s c u r r e n t  
Dielectric strength  
Insulation resistance  
Weight  
10 A  
2000 VAC for 1 min. between terminals  
1000 MΩ min. *  
Approx. 110g  
Approx. 25g  
Note: Use the P7S-14F-END in the ambient humidity range of 35 to 85%.  
* Measurement conditions: Measurement of the same points as for the dielectric strength at 500 VDC.  
Characteristics  
Contact resistance *1  
Operating time *2  
Release time *2  
100 mΩ max.  
50 ms max.  
50 ms max.  
Must operate voltage  
80% max.  
Must release voltage  
10% min.  
Mechanical  
Rated load  
18,000 operations/h  
1,800 operations/h  
100 MΩ min.  
Maximum operating  
frequency  
Insulation resistance *3  
Between coil and contacts:  
Between coil and pole 3 or coil and pole 4: 4,000 VAC, 50/60 Hz for 1 min  
Other than the above:2,500 VAC, 50/60 Hz for 1 min  
Between different poles:  
Between pole 1, 3, or 5 and pole 2, 4, or 6: 4,000 VAC, 50/60 Hz for 1 min  
Other than the above:2,500 VAC, 50/60 Hz for 1 min  
Between contacts of same polarity:1,500 VAC, 50/60 Hz for 1 min  
Dielectric strength *4 *5  
Destruction  
Malfunction  
Destruction  
Malfunction  
Mechanical  
Electrical  
10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude)  
10 to 55 to 10 Hz, 0.375-mm single amplitude (0.75-mm double amplitude)  
1,000 m/s2  
Vibration  
resistance  
Shock resistance  
100 m/s2  
10,000,000 operations min. (at approx. 18,000 operations/h)  
100,000 operations min. (at the rated load and approx. 1,800 operations/h)  
Durability *6  
AC15 AC240V 5A  
DC13 DC24V 2A  
NO Contact  
NC Contact  
Inductive load  
switching capability *7  
(IEC60947-5-1)  
AC15 AC240V 3A  
DC13 DC24V 2A  
Failure rate (P level)  
(reference value *8)  
5 VDC, 1 mA  
Ambient operating temperature  
Ambient operating humidity  
Weight  
–25 to 70°C (with no icing or condensation)  
5% to 85%  
Approx. 65 g  
Note: 1. The above values are initial values.  
2. Performance characteristics are based on a coil temparature of 23°C.  
*1. Measurement conditions: 5 VDC, 10 mA, voltage drop method.  
*2. Measurement conditions: Rated voltage operation  
Ambient operating temperature: 23°C  
Contact bounce time is not included.  
*3. The insulation resistance was measured with a 500-VDC megohmmeter at the same locations as the dielectric strength was measured.  
*4. When using a P7S Socket, the dielectric strength between coil and contacts and between different poles is 2,000 VAC, 50/60 Hz for 1 min.  
*5. The coil refers to terminals 0-1, pole 1 refers to terminals 1314, pole 2 refers to terminals 2324, pole 3 refers to terminals 3334, pole 4 refers  
to terminals 4142 or 4344, pole 5 refers to terminals 5152, and pole 6 refers to terminals 6162.  
*6. The durability is for an ambient temperature of 15 to 35°C and an ambient humidity of 25% to 75%.  
*7. AC15: cosφ = 0.3, DC13: L/R = 96-ms  
*8. The failure rate is based on an operating frequency of 60 operations/min.  
2
G7S-@-E  
Dimensions  
(Unit: mm)  
Relays with Forcibly Guided Contacts  
G7S-4A2B-E  
G7S-3A3B-E  
Terminal Arrangement/Internal  
Connection Diagram  
(Bottom View)  
62 max.  
G7S-4A2B-E  
22.5 max.  
58  
24 VDC  
+
0
1
13 14 33 34 51 52  
23 24 43 44 61 62  
6
37 max.  
Mounting Hole Dimensions  
0.5  
10.8  
5 min.  
G7S-3A3B-E  
±0.1  
14.5  
±0.1  
8
1.5  
0.6  
6
7
8
±0.1  
7
14.5  
24 VDC  
+
0
1
13 14 33 34 51 52  
23 24 41 42 61 62  
Fourteen,  
1.8 dia.  
±0.1  
±0.1  
21  
7
13  
6
35  
Sockets  
Track-mounting Socket  
P7S-14F-END  
Terminal Arrangement/Internal  
Connection Diagram  
(Top View)  
Indicator  
Fourteen, M3.0 × 8  
41 42  
43 44  
40 max.  
1
33  
±0.1  
33  
24  
23  
14  
13  
34  
62  
61  
51  
0
52  
4
7.5  
Mounting Hole Dimensions  
80 max.  
Two, M3.5- or  
4.0-dia. holes  
37  
±0.1  
33  
17  
3.1  
5.9  
5
90.5 max.  
(5)  
Back-mounting Socket (PCB Terminals)  
P7S-14P-E  
Terminal Arrangement/Internal  
Connection Diagram  
(Bottom View)  
70.5 max.  
±0.2  
28  
With G7S-4A2B-E mounted  
23.5 max.  
Mounting Hole Dimensions  
±0.2  
28  
(21)  
4.2  
Two, 6.5 dia. × 8 depth  
2.8  
(16.9)  
14.5  
8
With G7S-3A3B-E mounted  
57 max.  
Fourteen, 2.5 dia.  
6
Two, 3.6 dia.  
7
5×7=35  
13.2  
4.1  
6
7
8
(15)  
5×7=35  
16.9  
14.5  
23.5 max.  
3
G7S-@-E  
Certified Standards  
Forcibly Guided Contacts (from EN50205)  
G7S-@-E  
EN standards, VDE certified  
EN61810-1 (Electromechanical non-specified time all-or-nothing  
relays)  
If an NO contact becomes welded, all NC contacts will maintain a  
minimum distance of 0.5 mm when the coil is not energized. Likewise  
if an NC contact becomes welded, all NO contacts will maintain a  
minimum distance of 0.5 mm when the coil is energized.  
EN60255-23 (Contact performance)  
EN50205 (Relays with forcibly guided (linked) contacts)  
UL standards: UL508 (Industrial Control Equipment)  
CSA standards: CSA C22.2 No.14 (Industrial Control Equipment)  
P7S-@-E  
UL standards: UL508 (Industrial Control Equipment)  
CSA standards: CSA C22.2 No.14 (Industrial Control Equipment)  
Safety Precautions  
Be sure to read the precautions for “Precautions for All Relays” and “Precautions for All Relays with Forcibly Guided  
Contacts” in the website at:http://www.ia.omron.com/.  
Indication and Meaning for Safe Use  
Indicates a potentially hazardous situation  
which, if not avoided, may result in minor  
or moderate injury or in property damage.  
CAUTION  
Precautions  
for Safe Use  
Supplementary comments on what to do  
or avoid doing, to use the product safely.  
!CAUTION  
Do not pass currents of 6 A or more when using this  
product in combination with the P7S-14F/14P/14A  
Socket. Doing so may result in fire. Use this product in  
combination with the P7S-14F-END/14P-E.  
Precautions for Correct Use  
Wiring  
Use one of the following wires to connect to the P7S-14F-END.  
Stranded wire: 0.75 to 1.5 mm2  
Solid wire:  
1.0 to 1.5 mm2  
Tighten each screw of the P7S-14F-END to a torque of 0.78  
to 0.98 N·m.  
Wire the terminals correctly with no mistakes in coil polarity,  
otherwise the G7S will not operate.  
If you use the P7S-14F-END, the release time of the G7S will be  
longer because the P7S-14F-END has a built-in diode to absorb  
coil surge. Confirm operation under actual conditions before you  
use the P7S-14F-END.  
Cleaning  
The G7S is not of enclosed construction. Therefore, do not wash the  
G7S with water or detergent.  
Mounting  
The G7SA can be installed in any direction.  
4
Read and Understand This Catalog  
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or  
comments.  
Warranty and Limitations of Liability  
WARRANTY  
OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified)  
from date of sale by OMRON.  
OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR  
FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS  
DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER  
WARRANTIES, EXPRESS OR IMPLIED.  
LIMITATIONS OF LIABILITY  
OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS  
IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT  
LIABILITY.  
In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted.  
IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS  
OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT  
SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR.  
Application Considerations  
SUITABILITY FOR USE  
OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's  
application or use of the products.  
At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the  
products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product,  
machine, system, or other application or use.  
The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible  
uses of the products, nor is it intended to imply that the uses listed may be suitable for the products:  
Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog.  
Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles,  
safety equipment, and installations subject to separate industry or government regulations.  
Systems, machines, and equipment that could present a risk to life or property.  
Please know and observe all prohibitions of use applicable to the products.  
NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE  
SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND  
INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.  
PROGRAMMABLE PRODUCTS  
OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof.  
Disclaimers  
CHANGE IN SPECIFICATIONS  
Product specifications and accessories may be changed at any time based on improvements and other reasons.  
It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made.  
However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix or  
establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual  
specifications of purchased products.  
DIMENSIONS AND WEIGHTS  
Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown.  
PERFORMANCE DATA  
Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the  
result of OMRON’s test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON  
Warranty and Limitations of Liability.  
ERRORS AND OMISSIONS  
The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical,  
typographical, or proofreading errors, or omissions.  
2013.2  
In the interest of product improvement, specifications are subject to change without notice.  
OMRON Corporation  
Industrial Automation Company  
http://www.ia.omron.com/  
(c)Copyright OMRON Corporation 2013 All Right Reserved.  

相关型号:

G7S-3A3BDC24

Plug-In Safety Relay
OMRON

G7S-4A2B

Power/Signal Relay, 6PST, Momentary, 0.03A (Coil), 24VDC (Coil), 800mW (Coil), 6A (Contact), 24VDC (Contact), DC Input, AC/DC Output, Socket Mount,
OMRON

G7S-4A2B-E

Relays with Forcibly Guided Contacts and High Switching Capacity of 10A
OMRON

G7S-4A2B-E-DC24

Relays with Forcibly Guided Contacts and High Switching Capacity of 10A
OMRON

G7S-4A2BDC24

Plug-In Safety Relay
OMRON

G7S3

Silicon Power Rectifiers
EDAL

G7SA

Relays with Forcibly Guided Contacts
ETC

G7SA-2A2B

Compact, Slim Relays Conforming to EN Standards
OMRON

G7SA-2A2B110VDC

Power/Signal Relay, 4PST, Momentary, 0.004A (Coil), 110VDC (Coil), 420mW (Coil), 6A (Contact), 125VDC (Contact), DC Input, AC/DC Output, Through Hole-Straight Mount,
OMRON

G7SA-2A2B12VDC

Power/Signal Relay, 4PST, Momentary, 0.03A (Coil), 12VDC (Coil), 360mW (Coil), 6A (Contact), 125VDC (Contact), DC Input, AC/DC Output, Through Hole-Straight Mount,
OMRON

G7SA-2A2B18VDC

Power/Signal Relay, 4PST, Momentary, 0.02A (Coil), 18VDC (Coil), 360mW (Coil), 6A (Contact), 125VDC (Contact), DC Input, AC/DC Output, Through Hole-Straight Mount,
OMRON