Relays with Forcibly Guided Contacts  
G7SA  
Slim Relays with Forcibly  
Guided Contacts Conform-  
ing to EN Standards  
• EN50205 Class A, approved by VDE.  
• Ideal for use in safety circuits in production machin-  
ery.  
• Four-pole and six-pole Relays are available.  
• The Relay’s terminal arrangement simplifies PWB  
pattern design.  
• Reinforced insulation between inputs and outputs.  
Reinforced insulation between some poles.  
• UL, CSA approval.  
Ordering Information  
Relays with Forcibly Guided Contacts  
Type  
Sealing  
Poles  
Contacts  
Rated voltage  
Model  
G7SA-3A1B  
G7SA-2A2B  
G7SA-5A1B  
G7SA-4A2B  
G7SA-3A3B  
3PST-NO, SPST-NC  
DPST-NO, DPST-NC  
4 poles  
6 poles  
Standard  
Flux-tight  
5PST-NO, SPST-NC 24 VDC  
4PST-NO, DPST-NC  
3PST-NO, 3PST-NC  
Sockets  
Type  
LED indicator  
Poles  
4 poles  
Rated voltage  
Model  
P7SA-10F  
No  
---  
6 poles  
4 poles  
6 poles  
4 poles  
6 poles  
P7SA-14F  
Track-mounting  
Back-mounting  
Track mounting and screw mounting possible  
PCB terminals  
P7SA-10F-ND  
P7SA-14F-ND  
P7SA-10P  
Yes  
No  
24 VDC  
---  
P7SA-14P  
Model Number Legend  
G7SA-#A#B  
1
2
1. NO Contact Poles  
2:  
3:  
4:  
5:  
DPST-NO  
3PST-NO  
4PST-NO  
5PST-NO  
2. NC Contact Poles  
1:  
2:  
3:  
SPST-NC  
DPST-NC  
3PST-NC  
D-76  
Safety Sensors / Components  
Specifications  
Ratings  
Coil  
Must-operate  
voltage  
Must-release  
voltage  
Rated voltage Rated current  
Coil resistance  
Max. voltage  
110ꢀ (V)  
Power consumption  
4 poles: 15 mA  
24 VDC  
4 poles: 1,600 W  
4 poles: Approx. 360 mW  
6 poles: Approx. 500 mW  
75ꢀ max. (V)  
10ꢀ min. (V)  
6 poles: 20.8 mA 6 poles: 1,152 W  
Note: 1. The rated current and coil resistance are measured at a coil temperature of 23°C with tolerances of 15ꢀ.  
2. Performance characteristics are based on a coil temperature of 23°C.  
3. The value given for the maximum voltage is for voltages applied instantaneously to the Relay coil  
(at an ambient temperature of 23°C) and not continuously.  
Contacts  
Load  
Resistive load (cos f =1)  
Rated load  
6 A at 250 VAC, 6 A at 30 VDC  
Rated carry current  
6 A  
Max. switching voltage  
Max. switching current  
250 VAC, 125 VDC  
6 A  
Max. switching capacity (reference value) 1,500 VA, 180 W  
G7SA  
D-77  
Characteristics  
Sockets  
Model  
Continuous current  
6 A (see note 1)  
Dielectric strength  
Insulation resistance  
100 MW min. (see note 2)  
P7SA-14#  
2,500 VAC for 1 min. between poles  
Note: 1. If the P7SA-1#F is used between 55 and 85°C, reduce the continuous current (from 6 A) by 0.1 A for every degree.  
2. Measurement conditions: Measurement of the same points as for the dielectric strength at 500 VDC.  
3. When using the P7SA-1 F-ND at 24 VDC, use at an ambient operating temperature from -25 to 55°C.  
#
Relays with Forcibly Guided Contacts  
100 mW max.  
Contact resistance  
(The contact resistance was measured with 1 A at 5 VDC using the voltage-drop method.)  
Operating time (see note 2)  
Response time (see note 2)  
Release time (see note 2)  
20 ms max.  
10 ms max. (The response time is the time it takes for the normally open contacts to open after  
the coil voltage is turned OFF.)  
20 ms max.  
Mechanical  
Rated load  
36,000 operations/hr  
1,800 operations/hr  
Maximum operating  
frequency  
100 MW min. (at 500 VDC)  
(The insulation resistance was measured with a 500-VDC megger at the same places that the  
dielectric strength was measured.)  
Insulation resistance  
Between coil contacts/different poles: 4,000 VAC, 50/60 Hz for 1 min  
Dielectric strength (see notes 3, 4)  
Vibration resistance  
(2,500 VAC between poles 3-4 in 4-pole Relays or poles 3-5, 4-6, and 5-6 in 6-pole Relays.)  
Between contacts of same polarity: 1,500 VAC, 50/60 Hz for 1 min  
10 to 55 Hz, 1.5-mm double amplitude  
1,000 m/s2  
100 m/s2  
Destruction  
Shock resistance  
Durability  
Malfunction  
Mechanical  
Electrical  
10,000,000 operations min. (at approx. 36,000 operations/hr)  
100,000 operations min. (at the rated load and approx. 1,800 operations/hr)  
Min. permissible load (see note 5)  
(reference value)  
5 VDC, 1 mA  
Operating:-40°C to 85°C (with no icing or condensation)  
Storage:-40°C to 85°C (with no icing or condensation)  
Ambient temperature (see note 6)  
Ambient humidity  
Operating:35ꢀ to 85ꢀ  
Storage:35ꢀ to 85ꢀ  
4 poles: Approx. 22 g  
6 poles: Approx. 25 g  
Weight  
Approved standards  
EN61810-1 (IEC61810-1), EN50205, UL508, CSA22.2 No. 14  
Note: 1. The values listed above are initial values.  
2. These times were measured at the rated voltage and an ambient temperature of 23°C. Contact bounce time is not included.  
3. Pole 3 refers to terminals 31-32 or 33-34, pole 4 refers to terminals 43-44, pole 5 refers to terminals 53-54, and pole 6 refers to terminals  
63-64.  
4. When using a P7SA Socket, the dielectric strength between coil contacts/different poles is 2,500 VAC, 50/60 Hz for 1 min.  
5. Min. permissible load is for a switching frequency of 300 operations/min.  
6. When operating at a temperature between 70°C and 85°C, reduce the rated carry current (6 A at 70°C or less) by 0.1 A for each degree  
above 70°C.  
D-78  
Safety Sensors / Components  
Dimensions  
Note: All units are in millimeters unless otherwise indicated. The diagrams are drawn in perspective.  
Relays with Forcibly Guided Contacts  
Terminal Arrangement/  
Internal Connection Diagram  
(Bottom View)  
Printed Circuit Board  
Design Diagram  
(Bottom View)  
G7SA-3A1B  
G7SA-2A2B  
( 0.1 tolerance)  
G7SA-3A1B  
13 max.  
40 max.  
Ten, 1.4 dia.  
24 max.  
0.5  
1
0.5  
3.5  
G7SA-2A2B  
Note: Terminals 23-24, 33-34, and 43-44  
are normally open. Terminals 11-12  
and 21-22 are normally closed.  
Terminal Arrangement/  
Internal Connection Diagram  
(Bottom View)  
Printed Circuit Board  
Design Diagram  
(Bottom View)  
G7SA-5A1B  
G7SA-4A2B  
G7SA-3A3B  
( 0.1 tolerance)  
G7SA-5A1B  
13 max.  
Fourteen, 1.4 dia.  
50 max.  
24 max.  
3.5  
0.5  
G7SA-4A2B  
0.5  
1
G7SA-3A3B  
Note: Terminals 23-24, 33-34, 53-54, and  
63-64 are normally open. Terminals  
11-12, 21-22, and 31-32 are  
normally closed.  
G7SA  
D-79  
Sockets  
Terminal Installation/Internal Connection Diagram  
(Top View)  
Track-mounting Socket  
P7SA-10F, P7SA-10F-ND  
G7SA-3A1B  
Mounted  
G7SA-2A2B  
Mounted  
*
This display circuit is  
available only for  
"-ND" models.  
22.5 max.  
60.5 max.  
Note: Terminals 23-24,  
33-34, and 43-44  
are normally  
Ten, M3  
9 max.  
open. Terminals  
11-12 and 21-22  
are normally  
Mounting Hole Placement Diagram  
(Top View)  
closed.  
Two, 4 dia. or M3.5  
72 max.  
LED  
indicator  
9 max.  
4 dia.  
Note: The socket is shown with  
6
the finger cover removed.  
Note: Only the -ND Sockets have LED indicators.  
Terminal Arrangement/Internal Connection Diagram  
(Top View)  
Track-mounting Socket  
P7SA-14F, P7SA-14F-ND  
G7SA-5A1B  
Mounted  
G7SA-4A2B  
Mounted  
G7SA-3A3B  
Mounted  
30 max.  
60.5 max.  
Fourteen,  
M3  
9 max.  
Mounting Hole Placement Diagram  
(Top View)  
*
This display circuit is  
available only for  
"-ND" models.  
Two, 4 dia. or M3.5  
Note: Terminals 23-24,  
33-34, 43-44,  
72 max.  
LED  
indicator  
53-54, and 63-  
64 are normally  
open. Terminals  
11-12, 21-22,  
and 31-32 are  
normally closed.  
9 max.  
4 dia.  
Note: The socket is shown with the  
6
finger cover removed.  
Note: Only the -ND Sockets have LED indicators.  
D-80  
Safety Sensors / Components  
P7SA-10P Back-mounting Socket (for PCB)  
50 max.  
Terminal Arrangement/Internal Mounting Hole Placement  
Connection Diagram  
(Bottom View)  
(Bottom View)  
( 0.1 tolerance)  
15 max.  
G7SA-3A1B  
Mounted  
Three, 3.2 dia.  
(for M3 tapping screws)  
41.5 max.  
Ten, 1.1 dia.  
G7SA-2A2B  
Mounted  
Three, 2.6 dia.  
(for M3 tapping screws)  
Note: Terminals 23-24, 33-34, and 43-44  
are normally open. Terminals 11-12  
and 21-22 are normally closed.  
P7SA-14P Back-mounting Socket (for PCB)  
Terminal Arrangement/Internal  
Connection Diagram  
(Bottom View)  
Mounting Hole Placement  
(Bottom View)  
60 max.  
( 0.1 tolerance)  
15 max.  
G7SA-5A1B  
Mounted  
Three, 3.2 dia.  
(for M3 tapping  
screws)  
Fourteen,  
1.1 dia.  
41.5 max.  
G7SA-4A2B  
Mounted  
Three, 2.6 dia.  
(for M3 tapping screws)  
G7SA-3A3B  
Mounted  
Note: Terminals 23-24, 33-34, 43-44,  
53-54, and 63-64 are normally  
open. Terminals 11-12, 21-22,  
and 31-32 are normally closed.  
G7SA  
D-81  
Precautions  
Correct Use  
Relays with Forcibly Guided Contacts  
Caution  
While the Relay with Forcibly Guided Contacts has the previously  
described forcibly guided contact structure, it is basically the same  
as an ordinary relay in other respects. Rather than serving to prevent  
malfunctions, the forcibly guided contact structure enables another  
circuit to detect the condition following a contact weld or other mal-  
function. Accordingly, when a contact weld occurs in a Relay with  
Forcibly Guided Contacts, depending on the circuit configuration, the  
power may not be interrupted, leaving the Relay in a potentially dan-  
gerous condition (as shown in Fig. 1.)  
To configure the power control circuit to interrupt the power when a  
contact weld or other malfunction occurs, and to prevent restarting  
until the problem has been eliminated, add another Relay with Forc-  
ibly Guided Contacts or similar Relay in combination to provide  
redundancy and a self-monitoring function to the circuit (as shown in  
Fig. 2).  
Do not touch the terminal area of the Relays or the socket terminal  
area (charged area) while power is ON. Electric shock will result.  
Relays with Forcibly Guided Contacts  
A Relay with Forcibly Guided Contacts is a Relay with which a safety  
category circuit can be configured.  
Wiring  
Use one of the following wires to connect to the P7SA-10F/10F-ND/  
14F/14F-ND.  
Stranded wire:0.75 to 1.5 mm2  
Solid wire:1.0 to 1.5 mm2  
Tighten each screw of the P7SA-10F/10F-ND/14F/14F-ND to a  
torque of 0.98 N·m securely.  
The G9S/G9SA Safety Relay Unit, which combines Relays such as  
the Relay with Forcibly Guided Contacts in order to provide the  
above-described functions, is available for this purpose. By connect-  
ing a contactor with appropriate input and output to the Safety Relay  
Unit, the circuit can be equipped with redundancy and a self-monitor-  
ing function.  
Wire the terminals correctly with no mistakes in coil polarity, other-  
wise the G7SA will not operate.  
Cleaning  
The G7SA is not of enclosed construction. Therefore, do not wash  
the G7SA with water or detergent.  
Fig 1  
Fig 2  
S1  
S1  
Forcibly Guided Contacts (from EN50205)  
21  
22  
11  
12  
If an NO contact becomes welded, all NC contacts will maintain a  
minimum distance of 0.5 mm when the coil is not energized. Like-  
wise if an NC contact becomes welded, all NO contacts will maintain  
a minimum distance of 0.5 mm when the coil is energized.  
S2  
K1  
S2  
A1 A2 T11 T12  
B1  
Y1 X1  
13  
+
-
K1  
K1  
D
K1 K1  
K2 K2  
K3 K1 K3 K2 K3  
Power source  
F1  
K2  
K1  
K3  
PE T21  
T22  
14  
Power source  
D-82  
Safety Sensors / Components  

相关型号:

G7SA-2A2B

Compact, Slim Relays Conforming to EN Standards
OMRON

G7SA-2A2B110VDC

Power/Signal Relay, 4PST, Momentary, 0.004A (Coil), 110VDC (Coil), 420mW (Coil), 6A (Contact), 125VDC (Contact), DC Input, AC/DC Output, Through Hole-Straight Mount,
OMRON

G7SA-2A2B12VDC

Power/Signal Relay, 4PST, Momentary, 0.03A (Coil), 12VDC (Coil), 360mW (Coil), 6A (Contact), 125VDC (Contact), DC Input, AC/DC Output, Through Hole-Straight Mount,
OMRON

G7SA-2A2B18VDC

Power/Signal Relay, 4PST, Momentary, 0.02A (Coil), 18VDC (Coil), 360mW (Coil), 6A (Contact), 125VDC (Contact), DC Input, AC/DC Output, Through Hole-Straight Mount,
OMRON

G7SA-2A2BDC24

Compact, Slim Relays Conforming to EN Standards
OMRON

G7SA-3A1B

Compact, Slim Relays Conforming to EN Standards
OMRON

G7SA-3A1B12VDC

Power/Signal Relay, 4PST, Momentary, 0.03A (Coil), 12VDC (Coil), 360mW (Coil), 6A (Contact), 125VDC (Contact), DC Input, AC/DC Output, Through Hole-Straight Mount,
OMRON

G7SA-3A1B18VDC

Power/Signal Relay, 4PST, Momentary, 0.02A (Coil), 18VDC (Coil), 360mW (Coil), 6A (Contact), 125VDC (Contact), DC Input, AC/DC Output, Through Hole-Straight Mount,
OMRON

G7SA-3A1B21VDC

Power/Signal Relay, 4PST, Momentary, 0.017A (Coil), 21VDC (Coil), 360mW (Coil), 6A (Contact), 125VDC (Contact), DC Input, AC/DC Output, Through Hole-Straight Mount,
OMRON

G7SA-3A1B24VDC

Power/Signal Relay, 4PST, Momentary, 0.015A (Coil), 24VDC (Coil), 360mW (Coil), 6A (Contact), 125VDC (Contact), DC Input, AC/DC Output, Through Hole-Straight Mount,
OMRON

G7SA-3A1BDC24

Compact, Slim Relays Conforming to EN Standards
OMRON

G7SA-3A3B

Compact, Slim Relays Conforming to EN Standards
OMRON