BB-EIR-M-SC [ETC]
MEDIA CONVERTER DIN MOUNT;![BB-EIR-M-SC](http://pdffile.icpdf.com/pdf2/p00319/img/icpdf/BB-EIR-M-SC_1916264_icpdf.jpg)
型号: | BB-EIR-M-SC |
厂家: | ![]() |
描述: | MEDIA CONVERTER DIN MOUNT |
文件: | 总2页 (文件大小:1398K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
![](http://public.icpdf.com/style/img/ads.jpg)
Industrial 10/100Base-TX
to 100Base-FX Media Converters
Models EIR-M-ST, EIR-M-SC, EIR-S-SC
www.advantech-bb.com
PRODUCT FEATURES
•
•
•
Class 1/Division 2 rated
NEMA TS1/TS2 requirements for traffic control equipment
EN61000-6-2, -3 EMC generic standard immunity for industrial
environments
•
•
•
•
•
Rugged metal case, DIN rail mount (optional)
Wide temperature range ( -40 to +75 ºC)
Alarm for power or port link failure via relay output (dry contact)
Redundant 10 to 48 VDC power inputs (via terminal blocks)
IEC 60068 Vibration resistance, Shock, Free fall
The EIR-s-Sx Series is a group of 10/100 copper to 100Mbps fiber
unmanaged media converters.LANs can be extended beyond the normal
100 meter limit up to 2km with multi-mode fiber and up to 20km with single-
mode fiber. Since data is traveling via fiber, it is protected from ground loop
problems and electrical interference present along the cable run.
ORDERING INFORMATION
CLASS 1/
MODEL NUMBER 10/100 COPPER FIBER
DISTANCE
DIVISION 2
EIR-M-ST
EIR-M-SC
EIR-S-SC
1 (RJ-45)
1 (RJ-45)
1 (RJ-45)
Multi-mode (ST) 2 km
Multi-mode (SC) 2 km
Single-mode (SC) 20 km
X
X
X
Extension of LAN distances make it possible to communicate with remotely
located Ethernet enabled devices. The application could be as simple
as getting data from one end of the warehouse to the other, or tying two
buildings together, or enabling communications on a tank farm, or monitoring
a SCADA system at a waste water plant.
ACCESSORIES
MDR-40-24 - DIN rail mount power supply 24VDC, 1.7 A output power
Extended temperature and voltage specifications allow installation in the
toughest environments. These media converters are highly qualified for
environmental 10/100BASE Ethernet applications and certified by UL with
ISA12.12.01 Class I, Division 2 for use in hazardous locations.
All product specifications are subject to change without notice.
EIR-x-Sx Series_3117ds
orders@advantech-bb.com
support@advantech-bb.com
Corporate Headquarters: 707 Dayton Road, PO Box 1040 Ottawa, IL 61350 USA 815-433-5100 Fax 433-5104
European Office: Westlink Commercial Park, Oranmore Co. Galway Ireland +353 91 792444 Fax +353 91 792445
Industrial 10/100Base-TX
to 100Base-FX Media Converters
Models EIR-M-ST, EIR-M-SC, EIR-S-SC
SPECIFICATIONS
TECHNOLOGY
ENVIRONMENTAL
IEEE802.3 10Base-T,
Operating Temperature: -40 to 85°C (-40 to 185°F)
Standards
IEEE802.3u 100Base-TX/100Base-FX, IEEE802.3x
Storage Temperature:
Test Temperature:
-40 to 85°C (-40 to 185°F)
-40 to 85°C (-40 to 185°F)
Store-and-Forward.
Full and Half-duplex supported, and IEEE 802.3 Flow Control.
Processing Type
Ambient Relative
Humidity:
Forward and
Filtering Rate:
5 to 95% (non-condensing)
14,880pps for 10 Mbps; 148,810 pps for 100 Mbps
MECHANICAL
Enclosure
Packet buffer memory:
MAC Address
128K bits
2K
IP30, aluminum case
50W x 110D x 135H mm
INTERFACE
Dimensions:
(1.97W x 4.33D x 5.31H inches)
10/100Base-TX: 1 port
Ethernet Port
LED Indicators:
Relay Contact
Weight:
Installation:
0.8Kg (1.76 lbs.)
DIN rail mount (panel mount option)
REGULATORY APPROVALS
100Base-FX: 1 port
Per Unit: Power Status (Power 1, Power 2, Fault), Link-Fault-
Pass-Through
Per Port, 10/100TX: Link/Activity, Full-duplex/Collision, Speed
Per Port, 100FX: Link/Activity, Full-duplex/Collision
Relay contact rating with current 1A @ 30VDC, 0.5A @
120VAC
Hazardous locations:
Safety:
Class 1, Division 2 group A,B,C&D
UL60950-1, EN60950-1, IEC60950-1
CE
Configuration
POWER
DIP switch
FCC Part 15, Class A
EMS/EMI:
VCCI Class A
EN55022
Input Voltage: 10 to 48VDC (DC Terminal Block) or
12VDC (DC Jack) or 24VAC, 0.185A (AC Terminal Block)
4.32W Max. 0.36A @ 12VDC, 0.09A @ 48VDC
Input Voltage:
Consumption
EN61000-3-2, -3-3, -4-3, -4-4, -4-5, -4-6, -4-8, -6-2, 6-3
Vibration Resistance (IEC 60068-2-6 Fc)
Shock (IEC 60068-2-27 Ea)
Free Fall (IEC 60068-2-32 Ed)
Environmental Test
Compliance
NEMA
NEMA TS1 / TS2
MEANTIME BEFORE FAILURE
EIR-M-ST = 1,624,400.73 hours
EIR-M-SC = 1,624,400.73 hours
EIR-S-SC = 1,624,400.73 hours
MTBF
MTBF Calc. Method
Parts Count Reliability Prediction
MECHANICAL DIAGRAM
(dimensions in inches & centimeters)
4.33 in
11.0 cm
5.31 in
13.5 cm
5.31 in
13.5 cm
4.33 in
11.0 cm
orders@advantech-bb.com
support@advantech-bb.com
Corporate Headquarters: 707 Dayton Road, PO Box 1040 Ottawa, IL 61350 USA 815-433-5100 Fax 433-5104
European Office: Westlink Commercial Park, Oranmore Co. Galway Ireland +353 91 792444 Fax +353 91 792445
相关型号:
©2020 ICPDF网 联系我们和版权申明