BB-EIRP610-2SFP-T [ETC]

MNGD POE (8)10/100 POE, (2) SFP;
BB-EIRP610-2SFP-T
型号: BB-EIRP610-2SFP-T
厂家: ETC    ETC
描述:

MNGD POE (8)10/100 POE, (2) SFP

局域网(LAN)标准
文件: 总2页 (文件大小:170K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
maꢀaꢁꢂꢃ Iꢀꢃusꢄꢅial eꢄhꢂꢅꢀꢂꢄ ꢆwiꢄch  
2 gB rJ-45/ꢆFP Pꢇꢅꢄs, 8 Pꢇe Pꢇꢅꢄs  
EIRP610-2SFP-T  
Prodꢈꢉt FeAtꢈreꢆ  
•ꢀ Eightꢀ10/100ꢀBaseTꢀ802.3afꢀendꢀpointꢀPoEꢀinjectorꢀportsꢀ  
•ꢀ TwoꢀRJ-45/SFPꢀcomboꢀslotsꢀforꢀGigabitꢀEthernet  
•ꢀ Redundantꢀringꢀtechnologyꢀforꢀfastꢀrecovery  
•ꢀ Wideꢀoperatingꢀtemperature  
•ꢀ DINꢀRailꢀorꢀPanelꢀMount  
•ꢀ NEMAꢀTS2  
The EIRP610-2SFP-T is a 10 Port Managed Industrial Gigabit Ethernet  
Switch. In addition to 8 PoE copper RJ-45 ports, it has 2 RJ-45/SFP  
Combo ports to accommodate Gigabit Ethernet.  
orderIng InFormAtIon  
Model nuMBer descriPtion  
Industrial Gigabit Switch (8 CU, 2 CU/SFP)  
Power Over Ethernet Sourcing  
EIRP610-2SFP-T  
smaꢀꢀ Fꢁꢂm-faꢃꢄꢁꢂ Pꢀꢅggabꢀꢆ (sFP) Pꢁꢂꢄ: The SFP Ports provide  
flexibility when planning a network. Modules are available in multiple  
fiber formats. If an SFP module is not inserted, the associated combo port  
can be used with standard RJ-45 copper.  
hꢇgꢈ-spꢆꢆꢉ tꢂaꢊꢋmꢇꢋꢋꢇꢁꢊꢋ: The switch includes a switch controller  
that automatically senses transmission speed (10/100/1000 Mbps on two  
RJ45/SFP combo ports; 10/100 on eight PoE RJ45 copper ports).  
The RJ-45 interface also auto-detects MDI or MDI-X, eliminating the  
requirement for a crossover cable. Each port is buffered and supports  
store-and-forward protocol.  
dꢅaꢀ Pꢁwꢆꢂ iꢊpꢅꢄ: To reduce the risk of power failure, the switch has  
two 48 VDC power inputs. If the power fails, the switch will automatically  
use the secondary power input. Also, if the power goes out the  
corresponding P1 or P2 LED will go out and the Fault LED will light. The  
contacts for the alarm output will also open.  
AꢉꢉeꢆꢆorIeꢆ  
SDR-240-48 - DIN-Rail Power Supply, 10A, 240W, 48V  
C5UMB3FBL - 3 ft. - Blue - Category 5e UTP Patch Cord  
DFMM-LCLC-1M - Multi-Mode Duplex Fiber Cable, LC To LC, 1 Meter  
DFSM-LCLC-1M - Single-Mode Duplex Fiber Cable, LC To LC, 1 Meter  
SFP-1000SX-M-550M-T - SFP Module, 1000Base-SX, Multi-mode 550m, LC  
Connector (-40 to 85°C)  
SFP-100FX-M-2KM-T - SFP Module, 100Base-FX, Multi-mode 2km, LC Connector  
(-40 to 85°C)  
SFP-1000LX-S-10KM-T - SFP Module, 1000Base-LX, Single-mode 10km, LC  
Connector (-40 to 85°C)  
SFP-1000LX-S-20KM-T - SFP Module, 1000Base-LX, Single-mode 20km, LC  
Connector (-40 to 85°C)  
SFP-100FX-S-30KM-T - SFP Module, 100Base-FX, Single-mode 30km, LC  
Connector (-40 to 85°C)  
Fꢀꢆxꢇbꢀꢆ Mꢁꢅꢊꢄꢇꢊg: IP30 metal enclosure - DIN or Panel mounted.  
Maꢊagꢆꢉ: Powerful management functions including SNMP, LACP, VLAN,  
Port Trunking, Port Mirroring, Redundant Ring Technology, and Spanning  
Tree/Rapid Spanning Tree Protocol.  
Pꢁwꢆꢂ ovꢆꢂ eꢄꢈꢆꢂꢊꢆꢄ (Pꢁe): The eight 10/100 ports are classified as  
power sourcing equipment (PSE). These ports can be used to power  
IEEE 802.3af compliant powered devices (PD), eliminating the need for a  
separate power supply for each device.  
meꢉꢊAnIꢉAꢋ dIAgrAm  
6.2 cm  
2.44 in  
8.4 cm  
3.31 in  
ꢌꢇꢉꢆ opꢆꢂaꢄꢇꢊg tꢆmpꢆꢂaꢄꢅꢂꢆ: With an operating temperature of -40  
to 75°C (-40 to 167°F), this switch is suitable for use in harsh industrial  
environments.  
eaꢋy tꢂꢁꢅbꢀꢆꢋꢈꢁꢁꢄꢇꢊg: There are two LED indicators for each port that  
display the link status and transmission speed. Three LED indicators for  
power (P1, P2 and Fault) show power status. FWD LEDs on each PoE port  
indicate when a powered device is connected. These indicators allow  
you to quickly diagnose and correct problems and ensure your network  
remains reliable.  
13.1 cm  
5.16 in  
www.bb-elec.com |  
EIRP610-2SFP-T_3713ds  
maꢀaꢁꢂꢃ Iꢀꢃusꢄꢅial eꢄhꢂꢅꢀꢂꢄ ꢆwiꢄch  
2 gB rJ-45/ꢆFP Pꢇꢅꢄs, 8 Pꢇe Pꢇꢅꢄs  
EIRP610-2SFP-T  
ꢆPeꢉIFIꢉAtIonꢆ  
reꢍulꢎtorꢏ  
Port Based VLAN  
VLAN  
IEEE 802.1Q Tag VLAN (256 entries)  
VLAN ID (1 to 4096), GVRP (256 groups)  
FCC, CE, UL, NEMA TS2  
UL File Number: E173795  
Approvals  
Port Trunk w/LACP  
LLDP  
4 trunk groups / 4 trunk members  
Free Fall  
Shock  
Vibration  
IEC60068-2-32  
IEC60068-2-27  
IEC60068-2-6  
Allows the switch to advertise its  
Identification and capabilities on the LAN  
802.1d Spanning Tree  
Spanning Tree  
X-Ring  
802.1w Rapid Spanning Tree  
ieee stꢎndꢎrds  
IEEE 802.3  
Dual Homing, Ring Coupling, Dual Ring  
topologies. Recovery time below 20mS  
Determined by port, tag, IPv4 type of  
service, and IPv4/IPv6 different service  
802.1p class of service, 4 priority queues  
per port  
802.3. 10Base-T Ethernet  
100Base-TX and 100Base-FX Fast Ethernet  
1000Base-T  
IEEE 802.3u  
IEEE 802.3ab  
IEEE 802.3z  
IEEE 802.3x  
IEEE 802.3ad  
IEEE 802.3f  
IEEE 802.3d  
IEEE 802.1w  
IEEE 802.1p  
IEEE 802.1Q  
IEEE 802.1x  
IEEE 802.1ab  
netꢌork sPeciFicꢎtions  
Quality of Service  
Class of Service  
Gigabit Fiber  
Flow Control and Back Pressure  
Port trunk with LACP  
Power over Ethernet  
Spanning Tree Protocol  
Rapid Spanning Tree Protocol  
Class of Service  
VLAN Tag  
User Authentication (RADIUS)  
LLDP  
Supports 100 static MAC entries and 100 MAC Filter  
entries  
Supports TX, RX, and both packet  
IGMP Snooping v1, v2 (256 multi-cast  
groups and IGMP Query  
10 IP address entries for permission to  
access management functions  
802.1X Authentication / RADIUS  
Ingress Packet Filter and Egress Packet  
Limit. The egress rate control supports  
all packet types. Limit rates are: 100K to  
102400 Kbps (10/100) and 100 K to  
256000 Kbps (1000). Ingress packet  
Filter Type combination rules are  
Broadcast, Multi-Cast, Unknown Unicast,  
Broadcast/Multi-cast, Broadcast only, and  
all packets.  
Port Security  
Port Mirror  
IGMP  
IP Security  
Login Security  
Back-plane (Switching Fabric): 5.6Gbps  
Throughput (Full-dux): 3.3Mpps@64bytes  
14,880 pps Ethernet Port  
Bandwidth Control  
Architecture  
Transfer Rate  
148,800 pps Fast Ethernet Port  
1,488,000 pps Gigibit Fiber Ethernet  
Flow Control  
System Log  
SMTP  
Flow control full-dux, backpressure half-dux  
System Log and remote system log server  
SMPT SVR and 6 e-mail accounts for alerts  
Cold Start, Link Down, Link Up, Authorization  
Fail, PD Disconnect (PoE port event)  
Client, Server, Port and IP Binding  
DNS client with primary and secondary  
DNS server  
Buffer  
1 MB  
8K  
4 MB  
32 MB  
Broadcast Storm Filtering  
CSMA/CD  
MAC Table  
Flash ROM  
DRAM  
SNMP Trap  
DHCP  
Other  
interFꢎce  
RJ-45 Ports  
CU/SFP  
DNS  
8 x 10/100BaseT, 2 x10/100/1000,  
Auto MDI/MDI-X  
2 x Mini-GBIC SFP Combo Ports  
P1, P2 (Green) to indicate power  
Fault (Red) to indicate fault  
Mater (Green) to indicate ring master  
Link Activity on 10/100 ports (Green)  
Full Duplex / Collision (Amber)  
SFP LNK/ACT (Green)  
1000T LNK/ACT (Green)  
1000M (Green)  
FWD on PoE ports to indicate if a powered  
device is connected  
SNTP  
Firmware Update  
Poꢌer  
SNTP to synchronize system clock  
TFTP update, backup and restore  
Dual 48 VDC Inputs  
Reverse Polarity Protection  
Removable Terminal Block  
12 to 24 AWG  
9.6 Watts (Without PoE Load)  
116 Watts (Full PoE Load)  
1 Relay Output – Normally Closed  
Input Voltage  
Power Connection  
Wire Size  
LED  
Power Use  
Fault Output  
enVironMentꢎl  
Operating Temperature  
Storage Temperature  
Operating Humidity  
Mechꢎnicꢎl  
Enclosure  
Poe  
Ports  
- 40 to 75°C (-40 to 167°F)  
- 40 to 85°C (-40 to 185°F)  
0 to 95%  
1 through 8  
802.3af End Point Alternative A  
Power Source Equipment (PSE)  
15.4W per port  
1 & 2 – VCC(+), 3 & 6 – VCC(-)  
Standard  
Capacity  
Pin Assignment  
soFtꢌꢎre Feꢎtures  
Management  
IP30 Metal Enclosure  
35 mm DIN Rail or Panel Mount Attachments  
6.2 x 8.4 x 13.1 cm (2.44 x 3.31 x 5.16 in)  
Mounting  
Dimensions  
SNMP v1, v2C, v3, Web, Telnet, CLI  
RFC 1215 Trap, RFC1213 MIBII,  
RFC 1157 SNMP MIB, RFC 1493 Bridge  
MIB, RFC 2674 VLAN MIB, RFC 1643,  
RFC 1757, RSTP MIB, Private MIB, LLDP  
MIB  
SNMP MIB  
orders@bb-elec.com  
support@bb-elec.com  
International Office: 707 Dayton Road PO Box 1040 Ottawa, IL 61350 USA 815-433-5100 Fax 433-5104  
European Office: Westlink Commercial Park Oranmore Co. Galway Ireland +353 91 792444 Fax +353 91 792445  

相关型号:

BB-EIRSP1

SURGE PROTECTOR SINGLE STAGE
ETC

BB-EIS-G-SFP

CONVERTER ETHERNET MEDIA GIGABIT
ETC

BB-EIS-M-SC

MEDIA CONVERTER 10/100 TO 100FX
ETC

BB-EIS-M-ST

MEDIA CONVERTER 10/100 TO 100FX
ETC

BB-EIS-S-SC

MEDIA CONVERTER 10/100 TO 100FX
ETC

BB-EIS2-EXTEND

ETHERNET EXTENDERS OVER COPPER
ETC

BB-EPSG202

GIGABIT POE SPLITTER, (25W) 24 V
ETC

BB-ERT310

ROUTER 3G HSPA ETH
ETC

BB-ERT312

ROUTER 3G HSPA ETH
ETC

BB-ESP906CL

ETHERNET TO SER RS-232/422/485
ETC

BB-ESR901

ETHERNET TO SER RS-232/422/485
ETC

BB-ESR902

ETHERNET TO SER RS-232/422/485
ETC