3-line sine-wave EMC output filters  
for converters and power electronics  
SineFormer  
520 V AC, 11 ... 320 A, 40 °C  
Series/type:  
B84143V*R127  
Date:  
November 2007  
EPCOS AG 2007. Reproduction, publication and dissemination of this publication and the infor-  
mation contained therein without EPCOS’ prior express consent is prohibited.  
3-line filters  
B84143V*R127  
Sine-wave EMC output filters SineFormer  
Filters for converters and power electronics  
Rated voltage 520 V AC, 50/60 Hz  
Rated current 11 to 320 A  
Construction  
3-line sine-wave EMC output filter  
Metal case  
Features  
Supersede shielded motor cables  
Motor noise reduction  
Reduction of bearing current  
dv/dt reduction  
Easy to install  
Compact design  
Degree of protection: IP 201)  
Design complies with EN 60939, UL 1283, CSA 22.2 No.8  
Optimized for long motor cables (up to 1000 m) and  
operation under full load  
No integrated forced ventilation (maintenance-free)  
Connection to converter DC-link is not necessary  
Reducing eddy current losses  
Applications  
Frequency converters for motor drives, e.g.  
– elevators  
– pumps  
– traction and conveyer systems  
– HVAC systems (heating, ventilation and air conditioning)  
Terminals  
Line side (to converter): shielded cable up to 180 A;  
copper bus bars for the 320-A filter  
Load side (to motor): Finger-safe terminal blocks up to 180 A;  
copper bus bars for the 320-A filter  
Marking  
Marking on component:  
Manufacturer’s logo, ordering code, rated voltage,  
rated current, rated motor frequency, rated switch frequency,  
rated temperature, climatic category, date code  
Minimum marking on packaging:  
Manufacturer’s logo, ordering code, date code, quantity  
1) To IEC 60529:2001  
Please read Cautions and warnings and  
Important notes at the end of this document.  
2
07/07  
3-line filters  
B84143V*R127  
Sine-wave EMC output filters SineFormer  
Typical circuit diagram  
Converter  
U1  
Motor  
U2  
V1  
V2  
W1  
W2  
SSB2260-B  
Technical data and measuring conditions  
Rated voltage VR  
520 V AC, 50/60 Hz  
320-A type: 600 V AC  
Rated current IR  
Test voltage Vtest  
Referred to 40 °C ambient temperature  
2100 V DC, 2 s (line/line)  
2700 V DC, 2 s (lines/case)  
Frequency  
Motor  
0 ... 100 Hz  
Pulse (switch)  
4 ... 8 kHz (320-A type: 2.5 ... 3.0 kHz)  
Overload capability (thermal)  
Max. dv/dt on filter input  
Convection distance to other devices  
Vibration (sine)  
1.5 · IR for 1 min per hour  
5 kV/μs  
See next page  
10 cycles, 1 oct./min, 3 ... 13 Hz: 3 mm, 3 ... 200 Hz: 1 g  
Shock (half sine)  
15 g, 11 ms, 3 axis, 3 shocks per direction, 18 total  
(to IEC 60 068-2-6)  
Current (IR) derating depending on altitude From 1000 ... 4000 m: 5%/1000 m  
Current (IR) derating depending on  
ambient temperature  
From 40 ... 60 °C: 10%/5 °C  
Temperature  
Inside iron choke: approx. 130 °C  
Housing: approx. 70 °C  
Noise  
Approx. 72 dB (A)  
Climatic category (IEC 60068-1)  
25/100/21 (–25 °C/+100 °C/21 days damp heat test)  
Please read Cautions and warnings and  
Important notes at the end of this document.  
3
07/07  
3-line filters  
B84143V*R127  
Sine-wave EMC output filters SineFormer  
Characteristics and ordering codes  
VR  
AC  
IR  
Terminal Voltage Losses Rtyp  
Approx. Ordering code  
weight  
Approvals  
cross  
section  
mm2  
drop  
at  
100 Hz  
V
A
%
5
W
mΩ  
46  
32  
20  
15  
8
kg  
11  
520  
4
6
50  
70  
9
11  
B84143V0011R127  
×
×
×
×
×
×
×
×
×
×
×
×
16  
33  
7
B84143V0016R127  
B84143V0033R127  
B84143V0066R127  
B84143V0095R127  
B84143V0180R127  
B84143V0320R127  
10  
25  
50  
150  
8
120  
180  
250  
400  
750  
24  
66  
8
47  
95  
10  
10  
99  
180  
320  
6
125  
195  
600  
see dim. 10  
drawing  
4
× = approval granted  
Convection space (cabinet fan recommended)  
>100 mm  
>200 mm  
>100 mm  
>200 mm  
>200 mm  
SSB2258-Z  
SSB2257-R  
Please read Cautions and warnings and  
Important notes at the end of this document.  
4
07/07  
3-line filters  
B84143V*R127  
Sine-wave EMC output filters SineFormer  
Dimensional drawings  
B84143V0011R127 ... B84143V0095R127 (11 ... 95 A)  
l
Ring bolt  
only for  
66-A and  
95-A filters  
PE  
12  
c
øk  
r
d
e
f
Terminal blocks  
Q (Cross section of the wire end)  
SSB2259-8-E  
Dimensions (mm)  
Filter  
a
b
c
d
e
f
h
g
k
B84143...  
V0011R127 120  
V0016R127 120  
V0033R127 150  
V0066R127 210  
V0095R127 250  
100  
100  
120  
160  
200  
335  
375  
470  
650  
780  
280  
320  
380  
530  
650  
260  
300  
360  
500  
620  
700  
160  
190  
240  
280  
360  
6.6  
6.6  
6.6  
8.6  
11  
14  
900  
16  
20  
30  
43  
900  
1500  
1600  
Filter  
l
m
r
Terminal blocks  
Threaded bolt  
PE Nm  
2±0.1  
2±0.1  
Q
B84143...  
mm2  
Nm  
mm2  
2.5  
4
V0011R127 −  
V0016R127 −  
V0033R127 −  
V0066R127 545  
V0095R127 665  
4
0.6 ... 0.8 M5×9.5  
1.5 ... 1.8 M5×9.5  
6
10  
25  
50  
1.5 ... 1.8 M5×12.5 2±0.1  
6
122  
163  
165  
200  
4 ... 4.5  
6 ... 8  
M6×16.5 3±0.15  
M6×15.5 3±0.15  
16  
35  
Please read Cautions and warnings and  
Important notes at the end of this document.  
5
07/07  
3-line filters  
B84143V*R127  
Sine-wave EMC output filters SineFormer  
B84143V0180R127 (180 A)  
Terminal blocks 150 mm2  
Tightening torque 12 ... 15 Nm  
PE M8 x 30  
Cable clamp for cable ø55  
Tightening torque 6±0.3 Nm  
Wire end ferrule  
A70-25 (4x)  
(like DIN 46228)  
2700+10  
15  
880  
30  
800  
Shielded cable 70 mm2  
65  
910  
1130  
SSB2261-J-E  
Please read Cautions and warnings and  
Important notes at the end of this document.  
6
07/07  
3-line filters  
B84143V*R127  
Sine-wave EMC output filters SineFormer  
B84143V0320R127 (320 A)  
ø45  
ø25  
Cable gland MS-SC 36  
Ring bolt  
DIN 580-M10  
(232)  
12  
Converter  
Motor  
200  
200  
PE M12 x 19.5  
Tightening torque 15.5±1.5 Nm  
2 x 65 = 130  
2 x 65 = 130  
953  
910  
PE M10 x 32.5  
Tightening torque 10±1 Nm  
71.5  
660  
PE M10 x 36  
Tightening torque 10±1 Nm  
ø12  
(10 x)  
405±1  
405±1  
980±1  
1010  
SSB2262-S-E  
Please read Cautions and warnings and  
Important notes at the end of this document.  
7
07/07  
3-line filters  
B84143V*R127  
Sine-wave EMC output filters SineFormer  
Cautions and warnings  
Please note the advices in our data book “EMC Filters” (latest edition). Attention should be paid  
to the chapter “General safety notes”.  
It shall be ensured that only qualified persons (electricity specialists) are engaged on work such  
as planning, assembly, installation, operation, repair and maintenance. They must be provided  
with the corresponding documentation.  
Danger of electric shock. SineFormer contain components that store an electric charge. Danger-  
ous voltages can continue to exist at the filter terminals for longer than five minutes even after  
the power has been switched off.  
The protective earth connections shall be the first to be made when the SineFormer is installed  
and the last to be disconnected. Depending on the magnitude of the leakage currents, the par-  
ticular specifications for making the protective-earth connection must be observed.  
Impermissible overloading of the SineFormer, such as with circuits able to cause resonances,  
impermissible voltages at higher frequencies etc. can lead to bodily injury and death as well as  
cause substantial material damages (e.g. destruction of the filter housing).  
SineFormer must be protected in the application against impermissible exceeding of the rated  
currents by overcurrent protective.  
In case of leakage currents > 3.5 mA you shall mount the PE conductor stationary with the re-  
quired cross section before beginning of operation and save it against disconnecting. For leak-  
age currents IL1) < 10 mA the PE conductor must have a KU value2) of 4.5; for leakage currents  
IL 10 mA the PE conductor must have a KU value of 6.  
The information, specifications and values contained in this data sheet are based on our know-  
lege of typical requirements that are often placed on SineFormer. It is incumbent on the customer  
to check and decide whether this SineFormer is suitable for use in a particular application.  
In particular the values with regard to “temperature” and “noise” have to be observed.  
1) IL = leakage current  
2) The KU value (symbol KU) is a classification parameter of safety-referred failure types designed to ensure protec-  
tion against hazardous body currents and excessive heating.  
A value of KU = 4.5 with respect to interruptions is attained:  
with a permanently connected protective earth circuit 1.5 mm2  
with a protective earth circuit 2.5 mm2 connected via shroud connectors (IEC 60309-2).  
KU = 6 with respect to interruptions is achieved for fixed-connection lines 10 mm2 where the type of connection  
and line layout correspond to the requirements for PEN conductors as specified in relevant standards.  
Please read Cautions and warnings and  
Important notes at the end of this document.  
8
07/07  
Important notes  
The following applies to all products named in this publication:  
1. Some parts of this publication contain statements about the suitability of our products for  
certain areas of application. These statements are based on our knowledge of typical require-  
ments that are often placed on our products in the areas of application concerned. We neverthe-  
less expressly point out that such statements cannot be regarded as binding statements  
about the suitability of our products for a particular customer application.  
As a rule, EPCOS is either unfamiliar with individual customer applications or less familiar with  
them than the customers themselves. For these reasons, it is always ultimately incumbent on the  
customer to check and decide whether an EPCOS product with the properties described in the  
product specification is suitable for use in a particular customer application.  
2. We also point out that in individual cases, a malfunction of passive electronic components  
or failure before the end of their usual service life cannot be completely ruled out in the  
current state of the art, even if they are operated as specified. In customer applications re-  
quiring a very high level of operational safety and especially in customer applications in which the  
malfunction or failure of a passive electronic component could endanger human life or health  
(e.g. in accident prevention or life-saving systems), it must therefore be ensured by means of suit-  
able design of the customer application or other action taken by the customer (e.g. installation of  
protective circuitry or redundancy) that no injury or damage is sustained by third parties in the  
event of malfunction or failure of a passive electronic component.  
3. The warnings, cautions and product-specific notes must be observed.  
4. In order to satisfy certain technical requirements, some of the products described in this pub-  
lication may contain substances subject to restrictions in certain jurisdictions (e.g. be-  
cause they are classed as “hazardous”). Useful information on this will be found in our Material  
Data Sheets on the Internet (www.epcos.com/material). Should you have any more detailed  
questions, please contact our sales offices.  
5. We constantly strive to improve our products. Consequently, the products described in this  
publication may change from time to time. The same is true of the corresponding product  
specifications. Please check therefore to what extent product descriptions and specifications  
contained in this publication are still applicable before or when you place an order.  
We also reserve the right to discontinue production and delivery of products. Consequent-  
ly, we cannot guarantee that all products named in this publication will always be available.  
The aforementioned does not apply in the case of individual agreements deviating from the fore-  
going for customer-specific products.  
6. Unless otherwise agreed in individual contracts, all orders are subject to the current version  
of the “General Terms of Delivery for Products and Services in the Electrical Industry”  
published by the German Electrical and Electronics Industry Association (ZVEI).  
7. The trade names EPCOS, BAOKE, Alu-X, CeraDiode, CSSP, MiniBlue, MKK, MLSC, MotorCap,  
PCC, PhaseCap, PhaseMod, SIFERRIT, SIFI, SIKOREL, SilverCap, SIMDAD, SIMID,  
SineFormer, SIOV, SIP5D, SIP5K, ThermoFuse, WindCap are trademarks registered or pend-  
ing in Europe and in other countries. Further information will be found on the Internet at www.ep-  
cos.com/trademarks.  
9
07/07  

相关型号:

B84143V0066R227

3-line filters Sine-wave output filter
EPCOS

B84143V0075R227

3-line filters Sine-wave output filter
EPCOS

B84143V0095R127

3-line sine-wave EMC output filters for converters and power electronics -SineFormer-
EPCOS

B84143V0095R227

3-line filters Sine-wave output filter
EPCOS

B84143V0095R290

3−line sine−wave EMC output filters for converters and power electronics
EPCOS

B84143V0132R227

3-line filters Sine-wave output filter
EPCOS

B84143V0180R127

3-line sine-wave EMC output filters for converters and power electronics -SineFormer-
EPCOS

B84143V0180R227

3-line filters Sine-wave output filter
EPCOS

B84143V0180R290

3−line sine−wave EMC output filters for converters and power electronics
EPCOS

B84143V0250R227

3-line filters Sine-wave output filter
EPCOS

B84143V0320R127

3-line sine-wave EMC output filters for converters and power electronics -SineFormer-
EPCOS

B84143V0320R227

3-line filters Sine-wave output filter
EPCOS