EXB100 Series  
S i n g l e o u t p u t  
NEW Product  
Ultra wide trim range, 60% to 110% (1.08 Vdc to 5.5 Vdc)  
High efficiency, 91.5% @ 5 Vdc, 90.5% @ 3.3 Vdc  
Basic insulation (input to output)  
Industry standard half-brick pin-out  
No minimum load  
Overvoltage and overtemperature protection  
Remote ON/OFF  
Available RoHS compliant  
The EXB100 series of 100 W single output isolated dc-dc converters are specially  
designed to meet the power needs of low voltage silicon. Housed in an open-frame  
package with standard footprint, these latest generation converters offer efficiencies as  
high as 91.5% (typical on 5 V at 20 A). The series comprises two 48 V input models  
with 5 V and 3.3 V outputs. The 3.3 V model features a wide input range, trimmable  
output voltage and 30 A output (the 5 V model is limited to 20 A). Remote sense and  
remote ON/OFF facilities are included as standard, and the converters are  
comprehensively protected against overcurrent, overvoltage and overtemperature  
conditions.  
2 YEAR WARRANTY  
All specifications are typical at nominal input, full load at 25 °C unless otherwise stated  
SPECIFICATIONS  
OUTPUT SPECIFICATIONS  
Voltage adjustability  
60% to 110%  
1.5%  
Conducted emissions  
Radiated emissions  
EN55022 (See Note 7)  
EN55022 (See Note 7)  
EN55022  
Level A  
Level B  
Level A  
Output setpoint accuracy  
(See Longform Datasheet)  
Line regulation  
Load regulation  
Total error band  
Minimum load  
Overshoot  
Low line to high line  
0.2% max.  
0.4% max.  
3.0%  
Immunity:  
ESD air  
ESD contact  
Full load to min. load  
EN61000-4-2 8 kV, 15 kV  
EN61000-4-2 6 kV, 8 kV  
Radiated field enclosure EN61000-4-3 10 V/m  
Conducted (DC power)  
Conducted (signal)  
Input transients  
EN61000-4-6 10 V  
EN61000-4-6 10 V  
ETS 300 132-2, ETR 283  
0%  
(See Note 5)  
At turn-on and turn-off  
None  
Undershoot  
None  
Ripple and noise  
5 Hz to 20 MHz  
(See Note 1)  
Deviation  
100 mV pk-pk  
50 mV rms  
Efficiency  
See table  
Transient response  
(See Note 2)  
150 mV  
300 µs recovery to  
Switching frequency  
(Fixed)  
5 V  
3.3 V  
300 kHz typ.  
220 kHz typ.  
within total error band  
INPUT SPECIFICATIONS  
Input voltage range  
Input current  
36-75 Vdc  
Material flammability  
UL94V-0  
No load  
Remote OFF  
150 mA  
20 mA  
MTBF  
Representative model:  
MIL-HDBK-217F  
100% load, ground benign  
BELLCORE 332 591,000 hours  
1,034,000 hours  
Input current (max.)  
Input reflected ripple  
(See Note 3)  
3.15 A max. @ Io max.  
and Vin = 36-75 Vdc  
(See Note 4)  
60 mA (pk-pk)  
Remote ON/OFF  
(See Note 5)  
Open collector ref to -input  
>2 Vdc  
Logic compatibility  
Thermal performance  
Operating ambient  
-40 °C to +90 °C  
ON  
OFF  
temperature  
Non-operating  
3,000 m  
<1.2 Vdc  
-40 °C to +125 °C  
Altitude derating  
(above sea level)  
20%  
50%  
Undervoltage lockout  
Power up  
Power down  
36 V  
30 V  
10,000 m  
Start-up time  
(See Note 6)  
Power up  
Remote ON/OFF  
40 ms  
35 ms  
File Name: exb100s.pdf Rev: 18 Apr 2006  
EXB100 Series  
S i n g l e o u t p u t  
NEW Product  
OUTPUT  
POWER  
(MAX.)  
OUTPUT  
OUTPUT  
REGULATION  
INPUT  
OUTPUT  
VOLTAGE  
EFFICIENCY  
(TYP.)  
MODEL  
OVP  
CURRENT CURRENT  
VOLTAGE  
NUMBER (10)  
LINE  
LOAD  
(MIN.)  
0 A  
(MAX.)  
20 A  
100 W  
100 W  
36-75 Vdc  
36-75 Vdc  
6.0 Vdc  
3.9 Vdc  
5 V  
91.5%  
90.5%  
0.2%  
0.2%  
0.4% EXB100-48S05J (9)  
0.4% EXB100-48S3V3-RJ  
3.3 V  
0 A  
30 A  
Notes  
PROTECTION  
1
2
Measured as per recommended set-up. See Application Note 129 for details.  
di/dt = 0.1 A/µs, Vin = 48 Vdc, Tc = 25 °C, load change = 0.5 lo max. to  
0.75 lo max. and 0.75 lo max. to 0.5 lo max.  
Recommended input fusing is a 5 A HRC 200 V rated fuse.  
Measured with external filter. See Application Note 129 for details.  
Signal line assumed <3 m in length.  
Start-up into resistive load.  
The EXB100 meets levels A and B conducted emissions with external  
components. See Application Note 129 for details.  
Short circuit  
Overvoltage  
Continuous  
Non-latching clamp  
3
4
5
6
7
TELECOM SPECIFICATION  
Central office interface A  
ETS300-132-2 input voltage  
and current requirements  
8
9
This product is only for inclusion by professional installers within other  
equipment and must not be operated as a stand alone product.  
Negative remote ON/OFF option also available. Add suffix -R’ to part  
number, for example EXB100-48S05-RJ.  
CAUTION: Hazardous internal voltages and high temperatures.  
Ensure that unit is not user accessible.  
10 The ‘J’ suffix indicates that these parts are Pb-free (RoHS 6/6) compliant.  
TSE RoHS 5/6 (non Pb-free) compliant versions may be available on  
special request, please contact your local sales representative for details.  
Max open-frame  
converter height  
PIN CONNECTIONS  
seating plane  
PIN NUMBER  
FUNCTION  
-Vin  
Ø0.040 0.002  
(Ø1.02 0.05)  
6 Places  
1
2
3
4
5
6
7
8
9
Ø0.080 0.002  
(Ø2.03 0.05)  
Minimum clearance from  
2 Places  
No Pin  
seating plane to  
underside components  
Remote ON/OFF  
+Vin  
All dimensions in inches (mm)  
General tolerance 0.01in ( 0.25mm)  
except where specified otherwise  
2.280 0.02  
(57.91 0.5)  
+Vout  
+Sense  
Trim  
Vin-  
Vo-  
Sense-  
Trim  
-Sense  
-Vout  
Sense+  
Vo+  
Remote  
ON/OFF  
Vin+  
Bottom View  
1.900  
International Safety Standard Approvals  
(48.26)  
UL/cUL CAN/CSA 22.2 No. 60950-00 : UL 60950  
File No. E174104  
TÜV Product Service. Certificate No. B 02 02 38572 031  
Datasheet © Artesyn Technologies  
® 2006  
The information and specifications contained in this datasheet are believed to be correct at time of publication. However, Artesyn Technologies accepts no responsibility for consequences arising  
from printing errors or inaccuracies. Specifications are subject to change without notice. No rights under any patent accompany the sale of any such product(s) or information contained herein.  
Please consult our website for the following items: Application Note Longform Datasheet  
www.artesyn.com  
File Name: exb100s.pdf Rev: 18 Apr 2006  

相关型号:

EXB100-48S05

54-100W DC/DC Isolated Converters
ARTESYN

EXB100-48S05J

100 W DC-DC Isolated Converters
EMERSON-NETWO

EXB100-48S1V8

54-100W DC/DC Isolated Converters
ARTESYN

EXB100-48S3V3

54-100W DC/DC Isolated Converters
ARTESYN

EXB100-48S3V3-RJ

100 W DC-DC Isolated Converters
EMERSON-NETWO

EXB144720V

Chip Resistor Array
PANASONIC

EXB144720X

Chip Resistor Array
PANASONIC

EXB14472JV

Chip Resistor Array
PANASONIC

EXB14472JX

Chip Resistor Array
PANASONIC

EXB14AT1AR3X

片式衰减器
PANASONIC

EXB14AT2AR3X

片式衰减器
PANASONIC

EXB14AT3AR3X

片式衰减器
PANASONIC