EXB100-48S05J [EMERSON-NETWORKPOWER]
100 W DC-DC Isolated Converters; 100W的DC-DC隔离转换器型号: | EXB100-48S05J |
厂家: | EMERSON NETWORK POWER |
描述: | 100 W DC-DC Isolated Converters |
文件: | 总2页 (文件大小:408K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
EXB100 Series
S i n g l e o u t p u t
NEW Product
• Ultra wide trim range, 60% to 110% (1.08 Vdc to 5.5 Vdc)
• High efficiency, 91.5% @ 5 Vdc, 90.5% @ 3.3 Vdc
• Basic insulation (input to output)
• Industry standard half-brick pin-out
• No minimum load
• Overvoltage and overtemperature protection
• Remote ON/OFF
• Available RoHS compliant
The EXB100 series of 100 W single output isolated dc-dc converters are specially
designed to meet the power needs of low voltage silicon. Housed in an open-frame
package with standard footprint, these latest generation converters offer efficiencies as
high as 91.5% (typical on 5 V at 20 A). The series comprises two 48 V input models
with 5 V and 3.3 V outputs. The 3.3 V model features a wide input range, trimmable
output voltage and 30 A output (the 5 V model is limited to 20 A). Remote sense and
remote ON/OFF facilities are included as standard, and the converters are
comprehensively protected against overcurrent, overvoltage and overtemperature
conditions.
2 YEAR WARRANTY
All specifications are typical at nominal input, full load at 25 °C unless otherwise stated
SPECIFICATIONS
OUTPUT SPECIFICATIONS
Voltage adjustability
60% to 110%
1.5%
Conducted emissions
Radiated emissions
EN55022 (See Note 7)
EN55022 (See Note 7)
EN55022
Level A
Level B
Level A
Output setpoint accuracy
(See Longform Datasheet)
Line regulation
Load regulation
Total error band
Minimum load
Overshoot
Low line to high line
0.2% max.
0.4% max.
3.0%
Immunity:
ESD air
ESD contact
Full load to min. load
EN61000-4-2 8 kV, 15 kV
EN61000-4-2 6 kV, 8 kV
Radiated field enclosure EN61000-4-3 10 V/m
Conducted (DC power)
Conducted (signal)
Input transients
EN61000-4-6 10 V
EN61000-4-6 10 V
ETS 300 132-2, ETR 283
0%
(See Note 5)
At turn-on and turn-off
None
Undershoot
None
Ripple and noise
5 Hz to 20 MHz
(See Note 1)
Deviation
100 mV pk-pk
50 mV rms
Efficiency
See table
Transient response
(See Note 2)
150 mV
300 µs recovery to
Switching frequency
(Fixed)
5 V
3.3 V
300 kHz typ.
220 kHz typ.
within total error band
INPUT SPECIFICATIONS
Input voltage range
Input current
36-75 Vdc
Material flammability
UL94V-0
No load
Remote OFF
150 mA
20 mA
MTBF
Representative model:
MIL-HDBK-217F
100% load, ground benign
BELLCORE 332 591,000 hours
1,034,000 hours
Input current (max.)
Input reflected ripple
(See Note 3)
3.15 A max. @ Io max.
and Vin = 36-75 Vdc
(See Note 4)
60 mA (pk-pk)
Remote ON/OFF
(See Note 5)
Open collector ref to -input
>2 Vdc
Logic compatibility
Thermal performance
Operating ambient
-40 °C to +90 °C
ON
OFF
temperature
Non-operating
3,000 m
<1.2 Vdc
-40 °C to +125 °C
Altitude derating
(above sea level)
20%
50%
Undervoltage lockout
Power up
Power down
36 V
30 V
10,000 m
Start-up time
(See Note 6)
Power up
Remote ON/OFF
40 ms
35 ms
File Name: exb100s.pdf Rev: 18 Apr 2006
EXB100 Series
S i n g l e o u t p u t
NEW Product
OUTPUT
POWER
(MAX.)
OUTPUT
OUTPUT
REGULATION
INPUT
OUTPUT
VOLTAGE
EFFICIENCY
(TYP.)
MODEL
OVP
CURRENT CURRENT
VOLTAGE
NUMBER (10)
LINE
LOAD
(MIN.)
0 A
(MAX.)
20 A
100 W
100 W
36-75 Vdc
36-75 Vdc
6.0 Vdc
3.9 Vdc
5 V
91.5%
90.5%
0.2%
0.2%
0.4% EXB100-48S05J (9)
0.4% EXB100-48S3V3-RJ
3.3 V
0 A
30 A
Notes
PROTECTION
1
2
Measured as per recommended set-up. See Application Note 129 for details.
di/dt = 0.1 A/µs, Vin = 48 Vdc, Tc = 25 °C, load change = 0.5 lo max. to
0.75 lo max. and 0.75 lo max. to 0.5 lo max.
Recommended input fusing is a 5 A HRC 200 V rated fuse.
Measured with external filter. See Application Note 129 for details.
Signal line assumed <3 m in length.
Start-up into resistive load.
The EXB100 meets levels A and B conducted emissions with external
components. See Application Note 129 for details.
Short circuit
Overvoltage
Continuous
Non-latching clamp
3
4
5
6
7
TELECOM SPECIFICATION
Central office interface A
ETS300-132-2 input voltage
and current requirements
8
9
This product is only for inclusion by professional installers within other
equipment and must not be operated as a stand alone product.
Negative remote ON/OFF option also available. Add suffix ‘-R’ to part
number, for example EXB100-48S05-RJ.
CAUTION: Hazardous internal voltages and high temperatures.
Ensure that unit is not user accessible.
10 The ‘J’ suffix indicates that these parts are Pb-free (RoHS 6/6) compliant.
TSE RoHS 5/6 (non Pb-free) compliant versions may be available on
special request, please contact your local sales representative for details.
Max open-frame
converter height
PIN CONNECTIONS
seating plane
PIN NUMBER
FUNCTION
-Vin
Ø0.040 0.002
(Ø1.02 0.05)
6 Places
1
2
3
4
5
6
7
8
9
Ø0.080 0.002
(Ø2.03 0.05)
Minimum clearance from
2 Places
No Pin
seating plane to
underside components
Remote ON/OFF
+Vin
All dimensions in inches (mm)
General tolerance 0.01in ( 0.25mm)
except where specified otherwise
2.280 0.02
(57.91 0.5)
+Vout
+Sense
Trim
Vin-
Vo-
Sense-
Trim
-Sense
-Vout
Sense+
Vo+
Remote
ON/OFF
Vin+
Bottom View
1.900
International Safety Standard Approvals
(48.26)
UL/cUL CAN/CSA 22.2 No. 60950-00 : UL 60950
File No. E174104
TÜV Product Service. Certificate No. B 02 02 38572 031
Datasheet © Artesyn Technologies
® 2006
The information and specifications contained in this datasheet are believed to be correct at time of publication. However, Artesyn Technologies accepts no responsibility for consequences arising
from printing errors or inaccuracies. Specifications are subject to change without notice. No rights under any patent accompany the sale of any such product(s) or information contained herein.
Please consult our website for the following items: ꢀ Application Note ꢀ Longform Datasheet
www.artesyn.com
File Name: exb100s.pdf Rev: 18 Apr 2006