MSR33RT [ALLEN-BRADLEY]

Monitoring Safety Relays; 安全监视继电器
MSR33RT
型号: MSR33RT
厂家: Allen-Bradley    Allen-Bradley
描述:

Monitoring Safety Relays
安全监视继电器

继电器 监控
文件: 总2页 (文件大小:73K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Safety Relays  
Monitoring Safety Relays  
Minotaur MSR33RT/RTP  
Specifications  
Standards  
EN954-1, ISO13849-1, IEC/  
EN60204-1, ANSI B11.19,  
AS4024.1  
Safety Category  
Approvals  
Cat. 4 per EN954-1 (ISO13849-1)  
CE for all applicable directives, C-  
Tick, cULus, TUV  
Housing with removable  
terminals shown.  
Power Supply  
24V DC SELV (max with no load)  
electrically separate supply source  
Power Consumption  
Safety Inputs  
3W  
1 N.C. & 1 N.O.  
Max. Allowable Input Resistance 200 ohms  
Outputs  
2 N. O. Safety, Solid State  
1 N.O. Aux, Solid State  
Output Rating Safety  
Auxiliary  
2A @ 24VDC  
50mA @ 24VDC  
Description  
Short-Circuit Protection  
Power On Delay  
Response Time  
Inputs and outputs (safety and aux)  
The Minotaur MSR33RT/RTP is a microprocessor-based,  
monitoring safety relay, with safety-rated, solid state outputs.  
3s  
15ms  
20ms  
The MSR33RT/RTP is designed to operate with dual channel inputs  
where one channel is normally closed and the other is normally  
open. The Sipha sensors can be connected to the MSR33RT/RTP  
inputs.  
Recovery Time  
Indication LEDs  
Green = Power (Pwr)  
Green = CH1 Energized  
Green = CH2 Energized  
Test pulses are used to dynamically check the input circuits. All  
inputs and outputs are short-circuit protected.  
Pwr LED 3s Blink  
Diagnostics Constant  
2 Blinks  
Initialization  
Normal operation  
Config. change during operation  
Solid state output switch fault  
Internal Fault  
The reset capability of the MSR33RT/RTP allows it to set up for  
monitored manual or automatic reset. A start-up test can be enabled  
if automatic reset is used. The start-up test requires the inputs to be  
cycled before energizing the outputs. The reset and start-up test is  
determined by the connection wiring.  
4 Blinks  
Continuous Blinking  
Operating Temperature  
Humidity  
-5°C to +55°C (+14° to +131°F)  
90% RH  
Enclosure Protection  
Terminal Protection  
Pollution Degree  
Conductor Size  
IP40 (NEMA 1), DIN VDE 0470-1  
The outputs include two normally-open safety rated outputs that can  
be connected to loads up to 2A at 24V DC. These outputs can be  
used to send a safety stop signal to a machine or manufacturing  
system.  
IP20  
2
2
0.2 – 2,5mm (24 – 14AWG)  
Mounting  
In panel enclosure (IP54)  
35mm DIN rail  
The MSR30 also has one solid state, normally-open auxiliary output,  
which must only be used to indicate status of the MSR33RT/RTP.  
Weight  
Vibration  
Shock  
130g (0.287 lbs)  
10-55Hz, 0.35mm  
10g, 16ms, 100 shocks  
Features  
Category 4 per EN954-1  
See Output Ratings on page 1-29 for details. Consult factory for ratings not  
Stop Category 0  
shown.  
2 Solid State N.O. Safety Outputs  
1 Solid State N.O. Auxiliary Output  
1 N.O. & 1 N.C. Input  
Wiring Terminations  
S11 & S21 Pulse checking dynamic output  
S12 & S22 Input contacts  
A1 – S34 Reset switch  
S11 – S34 Automatic reset, start-up test disabled  
S21 – S34 Automatic reset, start-up test enabled  
A1 – Y2 Monitoring circuit  
4-28  
Safety Relays  
Monitoring Safety Relays  
Minotaur MSR33RT/RTP  
Product Selection  
Inputs  
Safety O utputs  
Auxiliary O utputs  
Term inals  
Fixed  
Catalogue Num ber  
440R-F23199  
2 N.O.  
Solid state  
1 N.O.  
Solid state  
1 N.C. & 1 N.O  
440R-F23200  
Removable  
Dimensions—mm (inches) Block Diagram  
22.5 (0.88)  
99 (3.89)  
A1  
Y41  
S11  
S34  
A1  
MSR33RT/RTP  
114.5  
(4.5)  
14  
24  
Y32  
A2  
14  
S12  
24  
S22  
S21  
Y32  
Y2  
Typical Wiring Diagrams  
+24V  
+24V  
Reset  
L1 L2 L3  
L1 L2 L3  
S11 S21 A1 S34 Y41 Y2  
S11 S21 A1 S34 Y41 Y2  
K1  
K1  
K2  
MSR33RT/RTP  
MSR33RT/RTP  
K2  
S12  
A2 14 2 4 Y32  
K1 K2  
S12  
A2 14 2 4 Y32  
K1 K2  
S22  
S22  
M
M
Aux to PLC  
or Indicator  
Aux to PLC  
or Indicator  
Ground  
Ground  
Sipha Sensor Inputs, Dual Channel Outputs,  
Monitored Manual Reset, Output Monitoring  
Start-up Test Disabled  
Sipha Sensor Inputs, Dual Channel Outputs,  
Automatic Reset, Output Monitoring  
Start-up Test Enabled  
+24V  
+24V  
Reset  
L1 L2 L3  
L1 L2 L3  
S11 S21 A1 S34 Y41 Y2  
S11 S21 A1 S34 Y41 Y2  
K1  
K1  
MSR33RT/RTP  
MSR33RT/RTP  
K2  
K2  
S12  
A2 14 2 4 Y32  
K1 K2  
S12  
A2 14 2 4 Y32  
K1 K2  
S22  
S22  
M
M
Aux to PLC  
or Indicator  
Aux to PLC  
or Indicator  
Ground  
Ground  
Dual Channel Inputs, Dual Channel Outputs,  
Monitored Manual Reset, Output Monitoring  
Start-up Test Disabled  
Dual Independent Inputs, Dual Channel Outputs,  
Automatic Reset, No Output Monitoring  
Start-up Test Disabled  
4-29  

相关型号:

MSR35H

Two Hand Relays
ALLEN-BRADLEY

MSR35HP

Two Hand Relays
ALLEN-BRADLEY

MSR38D

Monitoring Safety Relays with Delayed Outputs
ALLEN-BRADLEY

MSR5-0R015F1

RES 0.015 OHM 5W 1% RADIAL
RIEDON

MSR5-0R01F1

RES 0.01 OHM 5W 1% RADIAL
RIEDON

MSR5-0R02F1

RES 0.02 OHM 5W 1% RADIAL
RIEDON

MSR5-0R03F1

RES 0.03 OHM 5W 1% RADIAL
RIEDON

MSR5-0R05F1

RES 0.05 OHM 5W 1% RADIAL
RIEDON

MSR5-0R1F1

RES 0.1 OHM 5W 1% RADIAL
RIEDON

MSR5T

Monitoring Safety Relays
ALLEN-BRADLEY

MSR5T_1

Power Supply Unit
ALLEN-BRADLEY

MSR6R

Monitoring Safety Relays
ALLEN-BRADLEY