MSR38D [ALLEN-BRADLEY]

Monitoring Safety Relays with Delayed Outputs; 安全监视继电器具有延时输出
MSR38D
型号: MSR38D
厂家: Allen-Bradley    Allen-Bradley
描述:

Monitoring Safety Relays with Delayed Outputs
安全监视继电器具有延时输出

继电器 监控
文件: 总2页 (文件大小:55K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Safety Relays  
Monitoring Safety Relays with Delayed Outputs  
Minotaur MSR38D/DP  
Specifications  
Standards  
EN954-1, ISO13849-1, IEC/  
EN60204-1, ANSI B11.19,  
AS4024.1  
Safety Category  
Cat. 4 per EN954-1 (ISO13849-1)  
Approvals  
CE for all applicable directives, C-  
Tick, cULus, TUV  
Housing with removable  
terminals shown.  
Power Supply  
24V DC SELV  
3W  
Power Consumption  
Safety Inputs  
1 N.C.  
Max. Allowable Input Resistance 200 ohms  
Outputs  
2 N. O. Safety,  
1 N.C. Aux,  
Output Rating Safety  
Auxiliary  
2A @ 24V DC  
50mA @ 24V DC  
Description  
Fuses, Output External  
Power On Delay  
Response Time  
6A slow blow or 10A quick blow  
3s  
The Minotaur MSR38D/DP is a microprocessor-based, monitoring  
safety relay, with delayed, safety-rated, solid state outputs.  
15ms  
20ms  
Recovery Time  
The inputs of the MSR38D/DP are the same as the MSR30. They  
can be connected to gate interlocks, e-stop devices or 4-wire safety  
mats. The gate interlocks and e-stops can be either single channel or  
dual channel normally-closed circuits.  
Indication LEDs  
Green = Power (Pwr)  
Green = K1 Closed  
Green = K2 Closed  
Pwr LED 3s Blink  
Diagnostics Constant  
2 Blinks  
4 Blinks  
Continuous Blinking  
Initialization  
Normal operation  
Config. change during operation  
Solid state output switch fault  
Internal Fault  
The reset capability of the MSR38D/DP allows it to set up for  
manual or automatic start and restart.  
The outputs include two delayed normally-open safety rated outputs  
that can be connected to loads up to 2A at 24V DC. These outputs  
can be used to send a safety stop signal to a machine or  
manufacturing system. The delay is accomplished by the  
configuration of jumpers on the terminals. The delay can be easily  
adjusted by reconfiguring the jumpers.  
Operating Temperature  
Humidity  
-5°C to +55°C (+14° to +131°F)  
90% RH  
Enclosure Protection  
Terminal Protection  
Pollution Degree  
Conductor Size  
IP40 (NEMA 1), DIN 0470  
IP20, DIN 0470  
2
The MSR38D/DP also has one solid state normally-closed auxiliary  
output, which must only be used to indicate the status of the  
MSR38D/DP. The auxiliary output responds immediately to the  
change in input status; it is not delayed.  
2
0.2 – 2,5mm (24 – 14AWG)  
Mounting  
Weight  
35mm DIN rail  
130g (0.287 lbs)  
Vibration  
Shock  
10-55Hz, 0.35mm  
10g, 16ms, 100 shocks  
Features  
Cat. 4 per EN954-1  
See Output Ratings on page 1-29 for details. Consult factory for ratings not  
Stop Category 0 or 1  
shown.  
2 Delayed Solid State Safety Outputs  
1 Solid State Auxiliary Output  
1 N.C., 2 N.C. or Safety Mat Input  
Monitored Manual or Automatic/Manual Reset  
Wiring Terminations  
S11 & S21 Pulse train output  
S12 & S22 Input contacts  
A1 – S34 Reset switch  
S11 – S34 Automatic reset, start-up test disabled  
S21 – S34 Automatic reset, start-up test enabled  
A1 – Y2 Monitoring circuit  
A1 – Y41 Cross-fault monitoring disabled  
4-46  
Safety Relays  
Monitoring Safety Relays with Delayed Outputs  
Minotaur MSR38D/DP  
Product Selection  
Inputs  
Safety O utputs  
Auxiliary O utputs  
Term inals  
Fixed  
Catalogue Num ber  
440R-M23203  
1 N.C., 2 N.C.,  
or Safety Mat  
2 N.O.  
Solid state  
1 N.C.  
Solid state  
440R-M23204  
Removable  
Dimensions—mm (inches) Block Diagram  
22.5 (0.88)  
S21  
A1  
Y11  
Y41  
Y12  
99 (3.89)  
Y13  
S34  
S11  
A1  
MSR3D/DP  
114.5  
(4.5)  
18  
28  
Y32  
A2  
18  
S12  
28  
S22  
S21  
Y32  
Y2  
Typical Wiring Diagrams  
See MSR30 (page 4-26) for additional input wiring configurations.  
+24V  
+24V  
Reset  
L1 L2 L3  
L1 L2 L3  
S11 S21 A1 S34 Y41 Y2  
S11 S21 A1 S34 Y41 Y2  
K1  
K2  
K1  
MSR38D/DP  
MSR38D/DP  
S12  
A2 14 2 4 Y32  
K1 K2  
S12  
A2 14 24 Y32  
S22  
S22  
K1  
M
M
Aux to PLC  
or Indicator  
Aux to PLC  
or Indicator  
Ground  
Ground  
Dual Channel E-Stop, Dual Channel Delayed Outputs,  
Monitored Manual Reset, Output Monitoring  
Single Channel Gate Interlock, Single Channel Delayed  
Output, Automatic Reset, No Output Monitoring  
Application Details (Typical)  
Apply jumpers (links) on the terminals identified to achieve the desired off delay.  
Delay (s)  
Y11  
Y12  
Y13  
Delay (s)  
Y11  
S21  
Y12  
S11  
S11  
Y13  
Delay (s)  
50  
Y11  
Y12  
S21  
S11  
S11  
S21  
S21  
S11  
S11  
S21  
S21  
Y13  
S21  
S11  
S21  
S11  
S21  
S11  
S21  
S11  
S21  
0
0.5  
1
8
S11  
10  
12  
15  
18  
21  
26  
30  
40  
S21  
S11  
S11  
60  
S11  
S11  
S11  
S11  
S21  
S21  
S21  
S21  
S11  
S21  
80  
1.5  
2
S11  
S21  
S11  
100  
120  
160  
200  
250  
300  
S21  
S11  
S11  
3
S21  
S11  
S11  
4
S21  
S11  
S21  
5
S11  
S11  
S21  
S21  
S21  
6
S21  
S21  
4-47  

相关型号:

MSR5-0R015F1

RES 0.015 OHM 5W 1% RADIAL
RIEDON

MSR5-0R01F1

RES 0.01 OHM 5W 1% RADIAL
RIEDON

MSR5-0R02F1

RES 0.02 OHM 5W 1% RADIAL
RIEDON

MSR5-0R03F1

RES 0.03 OHM 5W 1% RADIAL
RIEDON

MSR5-0R05F1

RES 0.05 OHM 5W 1% RADIAL
RIEDON

MSR5-0R1F1

RES 0.1 OHM 5W 1% RADIAL
RIEDON

MSR5T

Monitoring Safety Relays
ALLEN-BRADLEY

MSR5T_1

Power Supply Unit
ALLEN-BRADLEY

MSR6R

Monitoring Safety Relays
ALLEN-BRADLEY

MSR6R_1

Guard Locking Interlocks
ALLEN-BRADLEY

MSR7805-033W

Low Cost, Non-isolated Wide Input, Single Output POL Switching Regulators
MPD

MSR7805-033WUP

Effi ciency to 95%
MPD