CLC175US48 [XPPOWER]

AC-DC Power Supplies; AC- DC电源
CLC175US48
型号: CLC175US48
厂家: XP POWER LIMITED    XP POWER LIMITED
描述:

AC-DC Power Supplies
AC- DC电源

文件: 总2页 (文件大小:144K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
175 Watts  
xppower.com  
CLC175 Series  
High Efficiency Resonant Topology  
High Power Density 9.3 W/in3  
12 V Fan Output as Standard  
Remote Sense as Standard  
5V Standby Option  
Remote On/Off Option  
Power Good Signal Option  
Specification  
Input  
General  
Input Voltage  
• 85-264 VAC (120-370 VDC), derate output  
power <90 VAC (See derating curve)  
Efficiency  
Isolation  
• 87ꢀ typical  
• 3000 VAC Input to Output  
1500 VAC Input to Ground  
500 VAC Output to Ground  
Input Frequency  
Input Current  
• 47-63 Hz  
• 3.0 A typical at 115 VAC, full load  
1.5 A typical at 230 VAC, full load  
Switching Frequency  
Signals (Option -A)  
• 70 kHz typical  
Inrush Current  
• 40 A max at 230 VAC, cold start 25 ºC  
• EN61000-3-2, class A  
• Power OK - open collector,  
Remote On/Off, 5 V Standby  
Power Factor  
MTBF  
• 390 kHrs per MIL-HDBK-217F  
Earth Leakage Current • 200/400 µA 115/230 VAC at 50 Hz  
475 µA 264 VAC at 60 Hz  
Environmental  
Input Protection  
• Internal 5 A fuse  
Operating Temperature • 0 ˚C to +70 ˚C derate linearly from +50 ˚C  
at 2.5ꢀ/˚C to 50ꢀ load at +70 ˚C. See  
derating curve and longform datasheet for  
thermal information.  
Output  
Output Voltage  
• 12-48 V (see tables)  
Output Voltage Trim  
Initial Set Accuracy  
Minimum Load  
5ꢀ  
Cooling  
• Forced-cooled >10 CFM  
• 95ꢀ RH, non-condensing  
• -40 ˚C to +85 ˚C  
1ꢀ V1, 5ꢀ V2, 3ꢀ V3  
Operating Humidity  
Storage Temperature  
Operating Altitude  
Shock  
• 0.1A required for V2 regulation when used  
Start Up Delay  
• 1 s typical, see longform datasheet for  
more details  
• 3000 m  
• 30 g pk, half sine, 6 axis  
• 2 g rms, 5 Hz to 500 kHz, 3 axis  
Start Up Rise Time  
Hold Up Time  
Drift  
• 50 ms  
Vibration  
• 16 ms min at 115 VAC  
0.2ꢀ after 20 min warm up  
0.5ꢀ max  
EMC & Safety  
Line Regulation  
Load Regulation  
Over/Undershoot  
Transient Response  
Low Voltage PSU EMC • EN61204-3, high severity level as below  
1ꢀ V1, 5ꢀ V2 & V3 max  
Emissions  
• EN55022 level B conducted  
EN55022 level A radiated  
• 5ꢀ typical  
• 4ꢀ max. deviation, recovery to within  
1ꢀ in 500 µs for a 50-75-50ꢀ load  
change  
Harmonic Currents  
Voltage Flicker  
Radiated Immunity  
EFT/Burst  
• EN61000-3-2, class A  
• EN61000-3-3  
• EN61000-4-3, level 3 Perf Criteria A  
• EN61000-4-4, level 3 Perf Criteria A  
Ripple & Noise  
• 1ꢀ pk-pk V1, others 2ꢀ,  
20 MHz bandwidth  
Surge  
• EN61000-4-5, installation class 3  
Perf Criteria A  
Overvoltage Protection • 115-140ꢀ Vnom, recycle input to reset  
Overload Protection • 110-150ꢀ V1 only  
Short Circuit Protection • Continuous trip and restart (Hiccup mode)  
Conducted Immunity  
Dips & Interruptions  
• EN61000-4-6, level 3 Perf Criteria A  
• EN61000-4-11, 30ꢀ 10 ms,  
60ꢀ 100 ms, 100ꢀ 5000 ms  
Perf Criteria A, B, B  
Temperature  
Coefficient  
• 0.05ꢀ/˚C  
Remote Sense  
• Compensates for 0.5 V total voltage drop  
Safety Approvals  
• IEC60950-1 CB report, CSA 22.2 No.  
60950-1, UL60950-1, TUV EN60950-1  
Remote On/Off  
(Inhibit/Enable)  
(Option -A)  
• Uncommitted isolated optocoupler diode,  
powered diode inhibits V1 & V2  
CLC175  
Models and Ratings  
Max  
Fan Output  
V2  
Standby Supply  
V3 (optional)  
Max Output Power(1)  
Output Voltage V1  
Model Number(2)  
Output Current V1  
175 W  
175 W  
175 W  
12.0 VDC  
24.0 VDC  
48.0 VDC  
13.9 A  
6.9 A  
3.5 A  
12.0 V/0.5 A  
12.0 V/0.5 A  
12.0 V/0.5 A  
5.0 V/0.5 A  
5.0 V/0.5 A  
5.0 V/0.5 A  
CLC175US12  
CLC175US24  
CLC175US48  
Notes  
1. 10 CFM airflow.  
2. For V3 5 V standby, Power OK & Inhibit, add suffix ‘-A’ to model number.  
Mechanical Details  
5.00 (127.0)  
0.22 (5.7)  
4.55 (115.6)  
1.30  
(33.0)  
0.20 (5.1)  
3.00  
(76.2)  
2.50  
(63.6)  
2.55  
(64.8)  
1.90  
(48.3)  
1.11  
(28.3)  
0.61  
(15.6)  
0.23 (5.7)  
0.19 (4.8)  
V Adj.  
SMD component height  
0.20 (5.1)  
0.14  
(3.5)  
0.25 Faston  
Ground Tab  
0.18  
(4.6)  
4 x ø0.156 (3.96) Mounting Holes  
ø0.312 (7.92) Clearance Top & Bottom  
Input Connector J1  
Output Connector J2  
Signal Connector J3  
Fan Connector J4  
Pin 1  
Pin 2  
0.25”Faston  
Line  
Neutral  
Earth  
Pin  
1
2
3
4
5
6
7
8
Single  
+V1  
+V1  
+V1  
+V1  
RTN  
RTN  
RTN  
RTN  
Pin  
1
2
3
4
5
6
7
8
Single  
+5V Standby  
Logic GND  
Logic GND  
Power OK  
Inhibit HI  
Inhibit LO  
+Sense  
Pin 1  
Pin 2  
Fan +(12V)  
Fan -  
J4 mates with Molex housing  
22-01-1024 and Molex series  
5103 crimp terminals.  
J1 mates with Molex housing  
09-50-1031 and Molex series  
5194 crimp terminals.  
-Sense  
9
+Vout  
10  
-Vout  
J2 mates with Molex  
housing 09-50-1081 and  
Molex series 5194 crimp  
terminals.  
J3 mates with JST housing  
PHDR-10VS and JST series  
SPHD-001T-P0.5 crimp  
terminals.  
Notes  
1. All dimensions in inches (mm). Tolerance .xx = 0.02 (0.50); .xxx = 0.01 (0.25)  
Derating Curves  
175  
175  
158  
88  
85  
90  
264  
0
+40  
+50  
+60  
+70  
Input Voltage (VAC)  
Ambient Temperature (ºC)  
30-Jul-08  

相关型号:

CLC175_12

175 Watts CLC Series
XPPOWER

CLC200

Fast Settling, Wideband Operational Amplifiers
NSC

CLC2000

High Output Current Dual Amplifier
CADEKA

CLC2000ISO8

High Output Current Dual Amplifier
CADEKA

CLC2000ISO8X

High Output Current Dual Amplifier
CADEKA

CLC2003ISO8

Operational Amplifier, 2 Func, BIPolar, PDSO8,
EXAR

CLC2003ISO8X

Operational Amplifier, 2 Func, BIPolar, PDSO8,
EXAR

CLC2005

Dual, Low Cost, +2.7V to 5.5V, 260MHz Rail-to-Rail Amplifier
CADEKA

CLC2005

Low Cost, 2.7V to 5.5V, 260MHz Rail-to-Rail Amplifiers
EXAR

CLC2005IMP8EVB

Low Cost, 2.7V to 5.5V, 260MHz Rail-to-Rail Amplifiers
EXAR

CLC2005IMP8MTR

Low Cost, 2.7V to 5.5V, 260MHz Rail-to-Rail Amplifiers
EXAR

CLC2005IMP8X

Low Cost, 2.7V to 5.5V, 260MHz Rail-to-Rail Amplifiers
EXAR