AFM45US12 [XPPOWER]
Energy Efficiency Level V;型号: | AFM45US12 |
厂家: | XP POWER LIMITED |
描述: | Energy Efficiency Level V |
文件: | 总2页 (文件大小:363K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
30-60 Watts
AFM Series
xppower.com
•
•
•
•
•
•
•
Energy Efficiency Level V
CEC2008 & EISA2007 Compliant
IT & Medical Approvals
China Compulsory Certification (CCC) Qualified
Optional Class II Versions
Optional White Case Versions
3 Year Warranty
Specification
Input
General
Efficiency
Energy Efficiency
• See table
• Level V
Input Voltage
• 80-264 VAC, derate output power 25%
<90 VAC
Isolation
• 4000 VAC Input to Output, 2 x MOPP
1500 VAC Input to Ground, 1 x MOPP*
Output 0 V is electrically connected to
Input Ground*. *Not C8 version.
Input Frequency
Input Current
• 47-63 Hz
• AFM30: 0.8 A rms at 115VAC,
AFM45: 1.2 A rms at 115VAC,
AFM60: 1.5 A rms at 115 VAC
• AFM30: 50 A max at 240VAC,
AFM45: 50 A max at 240VAC,
AFM60: 120 A max at 240VAC
Switching Frequency
Power Density
• 30/45 W: 58 kHz typ., 60 W: 52 kHz typ.
Inrush Current
Power Factor
3
3
• AFM30: 2.8 W/In , AFM45: 4.2 W/In ,
3
AFM60: 3.76 W/In
MTBF
• >250 kHrs to MIL-HDBK-217F at 25 °C,
GB, full load
• EN61000-3-2, class A
Earth Leakage Current • 150 µA max at 264 VAC/60 Hz
No Load Input Power • AFM30/45: <0.3 W, AFM60: <0.5 W
Environmental
Operating Temperature • 0 °C to +60 °C, derate from 100% power
at +40 °C to 60% power at +60 °C
• 10-95% RH, non-condensing
• -40 °C to +80 °C
Output
Operating Humidity
Storage Temperature
Operating Altitude
Shock
Output Voltage
• See table
• Not user-adjustable
Output Voltage Trim
Initial Set Accuracy
Minimum Load
• 2000 m
•
2%
• 30 g, 10 ms on 3 axes
• No minimum load required
• 3 s max at 115 VAC
2
Vibration
• 5-100 Hz, 2.31 m/s , 20 mins, 3 axes
Start Up Delay
Hold Up Time
• 8 ms minimum at 115 VAC
EMC & Safety
Emissions
Line Regulation
Load Regulation
Transient Response
•
1.0% maximum
• EN55011/22/FCC Class B conducted,
EN55011/22/FCC Class B radiated
• EN61000-3-2, Class A
• EN61000-3-3
• EN61000-4-2, 6 kV contact and
8 kV air discharge
• 2.5% maximum
• 4% max. deviation, recovery to within
1% in 500 µs for a 25% load change
Harmonic Currents
Voltage Flicker
ESD Immunity
(1)
Ripple & Noise
• 1% max pk-pk
Overvoltage Protection • 110-170% Vnom, recycle input to reset
Overload Protection
• AFM45/60: 110-170%,
AFM30: 110-220%, auto recovery
Radiated Immunity
EFT/Burst
• EN61000-4-3, 3 V/m Perf Criteria A
• EN61000-4-4, level 3 Perf Criteria A
• EN61000-4-5, installation class 3
Perf Criteria A
• EN61000-4-6, 3 Vrms Perf Criteria A
• EN61000-4-8, 3 A/m, Perf Criteria A
(7)
Short Circuit Protection • Trip and restart (hiccup mode)
Temperature
Coefficient
Surge
• 0.04%/°C
Conducted Immunity
Magnetic Field
Dips & Interruptions
• EN61000-4-11, 30% for 10 ms,
60% 100 ms, 100% 5000 ms,
Perf Criteria A, B, B
EN60601-1-2, 30% 500 ms, 60% 100 ms,
100% 10 ms, 100% 5000 ms,
(8)
Perf A, A, A, B
Safety Approvals
• EN60950-1, UL60950-1, IEC60950-1
EN60601-1 (3rd Ed.), UL60601-1 (2nd Ed.),
IEC60601-1 (3rd Ed.) China Compulsory
Certification (CCC) Qualified.
AFM30-60
Models and Ratings
Output Power
Output Voltage(6)
Output Current
Efficiency(7)
Model Number(3,4,5)
30 W
30 W
30 W
30 W
48 W
48 W
48 W
48 W
60 W
60 W
60 W
60 W
12 V
15 V
18 V
24 V
12 V
15 V
18 V
24 V
12 V
15 V
18 V
24 V
2.50 A
2.00 A
1.67 A
1.25 A
4.00 A
3.20 A
2.67 A
2.00 A
5.00 A
4.00 A
3.34 A
2.50 A
87.9%
88.4%
87.6%
88.0%
87.7%
88.0%
87.2%
87.7%
87.3%
88.2%
88.3%
87.8%
AFM30US12
AFM30US15
AFM30US18
AFM30US24
AFM45US12
AFM45US15
AFM45US18
AFM45US24
AFM60US12
AFM60US15
AFM60US18
AFM60US24
Notes
1. Ripple and noise measured at 20 MHz bandwidth with a 10 µF tantalum and
0.1 µF ceramic cap connected at the measurement point.
2. Total regulation includes initial set accuracy, line and load regulation.
3. For optional Class II versions with a polarised IEC320-C8 inlet, add suffix ‘C2’
to the model number, e.g. AFM60US24C2.
5. For white case version add suffix -W. MOQ applies, contact sales for details.
6. Other output voltages are available, contact sales for details.
7. Minimum average of efficiencies measured at 25%, 50%, 75% & 100% load.
8. A minimum load of 1% is required to meet performance criteria A.
9. Performance criteria given for high line input.
4. For alternative IEC320-C6 inlet, add suffix ‘C6’ to the model number
eg. AFM60US24C6.
Mechanical Details
37.4 2 (950 50)
1.31
(33.4)
Output Plug: ø 5.5 x ø 2.5 x 11.0 mm
inner positive
LED Indicator
A
Optional AC Cable Restraint (see note 8 below)
0.53
(13.7)
0.66
(16.8)
0.07
(1.8)
80º
C
0.68
(17.3)
0.17
(4.4)
B
AFM30 & 45
AFM60
A
B
C
4.76 (121.0)
1.97 (50.0)
1.21 (30.8)
4.92 (125.0)
2.44 (62.0)
1.33 (34.0)
Standard AC INLET
IEC-320-C14
Optional C6 AC INLET Optional C8P AC INLET
IEC-320-C6
IEC-320-C8P
Notes
1. All dimensions shown in inches (mm). Tolerance is 0.02 (0.5) maximum, except
output cable length.
2. Weight: AFM45: 0.56 lbs (256 g), AFM60: 0.78 lbs (360 g) approx.
3. Case material is PC Class 94 V-0.
7. For US mains lead order part US-MAINS-IEC for C14 versions,
US-MAINS-5 for C6 versions or US-MAINS-8 for C8 versions.
8. For optional AC Cable Restraint on the standard input version add suffix ‘A‘’ to
the model number e.g. AFM60US24A. AC Mains Lead must be Interpower
Corporation, part number 70006020300. Option AC Cable Restraint is not
available on IEC320-C6 inlet or Class II versions.
4. Output Lead: UL1185, 16 AWG
5. For European mains lead order part EU-MAINS-IEC for C14 versions,
EU-MAINS-5 for C6 versions or EU-MAINS-8 for C8 versions.
6. For UK mains lead order part UK-MAINS-IEC for C14 versions,
UK-MAINS-5 for C6 versions or UK-MAINS-8 for C8 versions.
9. The standard C7 cable fits the C8P connector.
19-Oct-15
相关型号:
©2020 ICPDF网 联系我们和版权申明