AFM45US15 [XPPOWER]

Energy Efficiency Level V;
AFM45US15
型号: AFM45US15
厂家: XP POWER LIMITED    XP POWER LIMITED
描述:

Energy Efficiency Level V

文件: 总2页 (文件大小:363K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
30-60 Watts  
AFM Series  
xppower.com  
Energy Efficiency Level V  
CEC2008 & EISA2007 Compliant  
IT & Medical Approvals  
China Compulsory Certification (CCC) Qualified  
Optional Class II Versions  
Optional White Case Versions  
3 Year Warranty  
Specification  
Input  
General  
Efficiency  
Energy Efficiency  
• See table  
• Level V  
Input Voltage  
• 80-264 VAC, derate output power 25%  
<90 VAC  
Isolation  
• 4000 VAC Input to Output, 2 x MOPP  
1500 VAC Input to Ground, 1 x MOPP*  
Output 0 V is electrically connected to  
Input Ground*. *Not C8 version.  
Input Frequency  
Input Current  
• 47-63 Hz  
• AFM30: 0.8 A rms at 115VAC,  
AFM45: 1.2 A rms at 115VAC,  
AFM60: 1.5 A rms at 115 VAC  
• AFM30: 50 A max at 240VAC,  
AFM45: 50 A max at 240VAC,  
AFM60: 120 A max at 240VAC  
Switching Frequency  
Power Density  
• 30/45 W: 58 kHz typ., 60 W: 52 kHz typ.  
Inrush Current  
Power Factor  
3
3
• AFM30: 2.8 W/In , AFM45: 4.2 W/In ,  
3
AFM60: 3.76 W/In  
MTBF  
• >250 kHrs to MIL-HDBK-217F at 25 °C,  
GB, full load  
• EN61000-3-2, class A  
Earth Leakage Current • 150 µA max at 264 VAC/60 Hz  
No Load Input Power • AFM30/45: <0.3 W, AFM60: <0.5 W  
Environmental  
Operating Temperature • 0 °C to +60 °C, derate from 100% power  
at +40 °C to 60% power at +60 °C  
• 10-95% RH, non-condensing  
• -40 °C to +80 °C  
Output  
Operating Humidity  
Storage Temperature  
Operating Altitude  
Shock  
Output Voltage  
• See table  
• Not user-adjustable  
Output Voltage Trim  
Initial Set Accuracy  
Minimum Load  
• 2000 m  
2%  
• 30 g, 10 ms on 3 axes  
• No minimum load required  
• 3 s max at 115 VAC  
2
Vibration  
• 5-100 Hz, 2.31 m/s , 20 mins, 3 axes  
Start Up Delay  
Hold Up Time  
• 8 ms minimum at 115 VAC  
EMC & Safety  
Emissions  
Line Regulation  
Load Regulation  
Transient Response  
1.0% maximum  
• EN55011/22/FCC Class B conducted,  
EN55011/22/FCC Class B radiated  
• EN61000-3-2, Class A  
• EN61000-3-3  
• EN61000-4-2, 6 kV contact and  
8 kV air discharge  
• 2.5% maximum  
• 4% max. deviation, recovery to within  
1% in 500 µs for a 25% load change  
Harmonic Currents  
Voltage Flicker  
ESD Immunity  
(1)  
Ripple & Noise  
• 1% max pk-pk  
Overvoltage Protection 110-170% Vnom, recycle input to reset  
Overload Protection  
• AFM45/60: 110-170%,  
AFM30: 110-220%, auto recovery  
Radiated Immunity  
EFT/Burst  
• EN61000-4-3, 3 V/m Perf Criteria A  
• EN61000-4-4, level 3 Perf Criteria A  
• EN61000-4-5, installation class 3  
Perf Criteria A  
• EN61000-4-6, 3 Vrms Perf Criteria A  
• EN61000-4-8, 3 A/m, Perf Criteria A  
(7)  
Short Circuit Protection Trip and restart (hiccup mode)  
Temperature  
Coefficient  
Surge  
• 0.04%/°C  
Conducted Immunity  
Magnetic Field  
Dips & Interruptions  
• EN61000-4-11, 30% for 10 ms,  
60% 100 ms, 100% 5000 ms,  
Perf Criteria A, B, B  
EN60601-1-2, 30% 500 ms, 60% 100 ms,  
100% 10 ms, 100% 5000 ms,  
(8)  
Perf A, A, A, B  
Safety Approvals  
• EN60950-1, UL60950-1, IEC60950-1  
EN60601-1 (3rd Ed.), UL60601-1 (2nd Ed.),  
IEC60601-1 (3rd Ed.) China Compulsory  
Certification (CCC) Qualified.  
AFM30-60  
Models and Ratings  
Output Power  
Output Voltage(6)  
Output Current  
Efficiency(7)  
Model Number(3,4,5)  
30 W  
30 W  
30 W  
30 W  
48 W  
48 W  
48 W  
48 W  
60 W  
60 W  
60 W  
60 W  
12 V  
15 V  
18 V  
24 V  
12 V  
15 V  
18 V  
24 V  
12 V  
15 V  
18 V  
24 V  
2.50 A  
2.00 A  
1.67 A  
1.25 A  
4.00 A  
3.20 A  
2.67 A  
2.00 A  
5.00 A  
4.00 A  
3.34 A  
2.50 A  
87.9%  
88.4%  
87.6%  
88.0%  
87.7%  
88.0%  
87.2%  
87.7%  
87.3%  
88.2%  
88.3%  
87.8%  
AFM30US12  
AFM30US15  
AFM30US18  
AFM30US24  
AFM45US12  
AFM45US15  
AFM45US18  
AFM45US24  
AFM60US12  
AFM60US15  
AFM60US18  
AFM60US24  
Notes  
1. Ripple and noise measured at 20 MHz bandwidth with a 10 µF tantalum and  
0.1 µF ceramic cap connected at the measurement point.  
2. Total regulation includes initial set accuracy, line and load regulation.  
3. For optional Class II versions with a polarised IEC320-C8 inlet, add suffix ‘C2’  
to the model number, e.g. AFM60US24C2.  
5. For white case version add suffix -W. MOQ applies, contact sales for details.  
6. Other output voltages are available, contact sales for details.  
7. Minimum average of efficiencies measured at 25%, 50%, 75% & 100% load.  
8. A minimum load of 1% is required to meet performance criteria A.  
9. Performance criteria given for high line input.  
4. For alternative IEC320-C6 inlet, add suffix ‘C6’ to the model number  
eg. AFM60US24C6.  
Mechanical Details  
37.4 2 (950 50)  
1.31  
(33.4)  
Output Plug: ø 5.5 x ø 2.5 x 11.0 mm  
inner positive  
LED Indicator  
A
Optional AC Cable Restraint (see note 8 below)  
0.53  
(13.7)  
0.66  
(16.8)  
0.07  
(1.8)  
80º  
C
0.68  
(17.3)  
0.17  
(4.4)  
B
AFM30 & 45  
AFM60  
A
B
C
4.76 (121.0)  
1.97 (50.0)  
1.21 (30.8)  
4.92 (125.0)  
2.44 (62.0)  
1.33 (34.0)  
Standard AC INLET  
IEC-320-C14  
Optional C6 AC INLET Optional C8P AC INLET  
IEC-320-C6  
IEC-320-C8P  
Notes  
1. All dimensions shown in inches (mm). Tolerance is 0.02 (0.5) maximum, except  
output cable length.  
2. Weight: AFM45: 0.56 lbs (256 g), AFM60: 0.78 lbs (360 g) approx.  
3. Case material is PC Class 94 V-0.  
7. For US mains lead order part US-MAINS-IEC for C14 versions,  
US-MAINS-5 for C6 versions or US-MAINS-8 for C8 versions.  
8. For optional AC Cable Restraint on the standard input version add suffix Ato  
the model number e.g. AFM60US24A. AC Mains Lead must be Interpower  
Corporation, part number 70006020300. Option AC Cable Restraint is not  
available on IEC320-C6 inlet or Class II versions.  
4. Output Lead: UL1185, 16 AWG  
5. For European mains lead order part EU-MAINS-IEC for C14 versions,  
EU-MAINS-5 for C6 versions or EU-MAINS-8 for C8 versions.  
6. For UK mains lead order part UK-MAINS-IEC for C14 versions,  
UK-MAINS-5 for C6 versions or UK-MAINS-8 for C8 versions.  
9. The standard C7 cable fits the C8P connector.  
19-Oct-15  

相关型号:

AFM45US18

Energy Efficiency Level V
XPPOWER

AFM45US24

Energy Efficiency Level V
XPPOWER

AFM60US12

Energy Efficiency Level V
XPPOWER

AFM60US15

Energy Efficiency Level V
XPPOWER

AFM60US18

Energy Efficiency Level V
XPPOWER

AFM60US24

Energy Efficiency Level V
XPPOWER

AFM704/CH

Data Line Filter, 1 Function(s), 28V
INFINEON

AFM704/CHPBF

Data Line Filter, 1 Function(s), 28V, LEAD FREE PACKAGE-6
INFINEON

AFM704A

EMI FILTER / PROTECTION HYBRID
INFINEON

AFM704A/CH

EMI FILTER / PROTECTION HYBRID
INFINEON

AFM704A/CHPBF

1 FUNCTIONS, 28V, DATA LINE FILTER, LEAD FREE PACKAGE-6
INFINEON

AFM704A/ES

EMI FILTER / PROTECTION HYBRID
INFINEON