FL3.3-66150 [VICOR]
EN Compliant, Autoranging Switcher; EN标准,自动量程切换型号: | FL3.3-66150 |
厂家: | VICOR CORPORATION |
描述: | EN Compliant, Autoranging Switcher |
文件: | 总8页 (文件大小:158K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
Data Sheet
FlatPAC-ENTM
EN Compliant, Autoranging Switcher
Features
• EN 61000-3-2 harmonic current compliance
• Low profile package (1.4"/35,6mm)
• Output power to 500W
(425W for EN compliance)
• Up to 4 user specifiable outputs
• "Autosense" feature
• Compliant to EN 55022, Class A,
EN 55022, Class B (may require optional
in-line filter), EN 61000-4-4 and EN 61000-4-5
• Rugged: Meets MIL-STD-810E for vibration
• Drop-in upgrade to our “2up” FlatPAC
• RS-232 microcontroller interface
1.4"H x 5.0"W x 9.2"L
35,6 x 127,0 x 233,7 mm
Up to 500W
• Safety agency approvals: TÜV, cULus, CE
1 to 4 Outputs
Overview
3
With a power density greater than 7W/in ,
Westcor’s FlatPAC-EN is an ultra low profile,
compact, EN compliant autoranging AC-DC
switcher. It is capable of providing up to 500
Watts from up to 4 isolated outputs.
Part Numbering
For maximum versatility and flexibility, the
FlatPAC-EN can be configured with standard
Vicor DC-DC converter modules - full, half
and quarter brick sizes. These modules cover
the entire range of outputs from 1 to 100Vdc
and 25 to 500 Watts, as well as an array of
non-standard voltages. The optimum FlatPAC-
EN solution can be factory configured based on
your exact voltage and power requirements.
FL
X1
-
X2
X3 - X X X - E
Number of
1st Gen modules
Product Prefix
Factory
Assigned
FL FlatPAC-EN
Number of
Output
Voltages
Number of
Extended
2nd Gen modules
Temperature
Range Version
(Optional)
For conducted EMI, the FlatPAC-EN conforms
with FCC Class A and B, and EN 55022,
Class A and B. Some configurations may require
our optional external in-line filter to meet
EN 55022 Class B. Further, besides meeting
the cULus, TÜV and CE safety agency
approvals, the FlatPAC-EN complies with
harmonic current limits per EN 61000-3-2,
Electrical Fast Transient/Burst per EN 61000-4-4
and Surge Immunity per EN 61000-4-5. For
harmonic current compliance to EN 61000-3-2,
do not exceed input current of 3.33 A rms at
230Vac, 50 Hz.
*
Autosense Feature
This is a new feature implemented in all converter slots in the FlatPAC-EN.
If remote sense connections are not needed or are inadvertently not made, no
local sense connections are necessary. Simply connect the output(s) to the load
and the converter(s) will automatically operate in the local sense mode. If remote
sense connections are made, the unit will operate in remote sense mode.
*Applies to outputs utilizing Maxi or Mini size converters.
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715 Westcor Division 408-522-5280
FlatPAC-EN
Rev. 1
Page 1 of 8
Set your site on VICOR at www.vicorpower.com
DC Output Selections
The tables below show a sampling of some of the most popular standard outputs that can be configured into the FlatPAC-EN.
Available Power (W) per Package Size
Output
Voltage
Maxi
Mini
Micro
2nd Gen
50
2nd Gen
160
1st Gen
2nd Gen
100
1st Gen
2Vdc
3.3Vdc
5Vdc
80
60
40
30
50
75
75
75
75
75
75
264
132
200
200
200
200
200
200
99
150
66
75
400
150
150
150
150
150
150
200
100
100
100
100
100
100
100
12Vdc
15Vdc
24Vdc
28Vdc
48Vdc
500
250
150
500
250
150
500
250
150
500
250
150
500
250
150
FlatPAC-EN Configurations
Vicor’s DC–DC converter modules are used to populate the
FlatPAC-EN. There are several configurations available
depending on module size, power limitation and location
of the MiniHAM*. The two-output FlatPAC-EN contains
1 Maxi and 1 Mini. The three-output FlatPAC-EN contains 3
Minis. The four output FlatPAC-EN contains 1 Mini and 3
Micros. See below.
FlatPAC-EN Configurations
Maximum Total Output Power = 500W (425W for EN61000-3-2 Compliance)
2 Output**
3 Output
4 Output
Mini
Mini
M4
MiniHAM
MiniHAM
MiniHAM
M3
Maxi
M2
Micro
M1
Micro
M2
Micro
Mini
M1
Mini
M2
Mini
M1
M3
M2
M2
M3
M1
M1
M1
M2
M3
M4
Note: The FlatPAC-EN is limited to a maximum output power of 500W regardless of the module capability. For example, if three
Mini modules are used, the maximum output power for the FlatPAC-EN is still 500W irrespective of the maximum output power of
the modules. For EN 61000-3-2 harmonic current compliance, input current of 3.33 A rms should not be exceeded.
* The MiniHAM is a passive harmonic attenuator specifically designed for EN compliance. Unlike active PFC solutions, the
MiniHAM generates no EMI, greatly simplifying and reducing system noise filtering requirements. It is also considerably smaller
and more efficient than active alternatives and improves the unit’s MTBF. It will provide harmonic current compliance at 230Vac
input at up to 425W of output power.
** For a single output configuration either M1 or M2 is used.
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715 Westcor Division 408-522-5280
FlatPAC-EN
Rev. 1
Page 2 of 8
Set your site on VICOR at www.vicorpower.com
Performance Specifications
The following are typical performance specifications at room ambient temperature, nominal line voltage (115/230Vac) and
75% load on all outputs, unless specified otherwise. For detail specifications, consult the FlatPAC-EN Design Guide
available online at (vicorpower.com).
INPUT CHARACTERISTICS
Parameter
AC Input
Voltage
Typ
Units
Notes
90-132/180-264
47-63
Vac
Hz
Derates to 260W @ 90Vac, 400W @ 180Vac
Frequency
DC Input
250-380
Vdc
Line Regulation
Inrush Current
@ 115Vac
0.2
%
From low line to high line
8
8
A rms
A rms
@ 230Vac
Ride Through Time
@ 115Vac
12/15
16/18
ms
ms
W
@ 230Vac
@ Load
500/400
Conducted EMI/RFI
FCC Class A, EN 55022 Class A
FCC Class B, EN 55022 Class B
EN 55022 Class B may need external
optional in-line filter
Power Factor
> 0.70
>75% load
Harmonic Current Limits
Transient Burst Immunity
Surge Immunity
EN 61000-3-2/A14
EN 61000-4-4
EN 61000-4-5
EN 61000-4-11
Input current of 3.33A rms max. at 230Vac, 50Hz
Voltage Dips
Criteria B
Dielectric Withstand
Primary to Chassis GND
Primary to Secondary
1,500
3,000
Vrms
Vrms
Secondary to Chassis GND
500
Vrms
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715 Westcor Division 408-522-5280
FlatPAC-EN
Rev. 1
Page 3 of 8
Set your site on VICOR at www.vicorpower.com
Performance Specifications Cont.
OUTPUT CHARACTERISTICS
Parameter
Typ
Units
Notes
Setpoint Accuracy
0.5
%
Of Vnom
Load Regulation
0.2
0.005
0.02
%
No Load to full load
-20°C to +65°C
Temperature Regulation
Long Term Drift
%/°C
%/khr
Output Ripple & Noise
≤10Vout
100
1.0
mV
%
20MHz band width
20MHz band width
>10Vout
Voltage Trim Range
1st Gen Modules
2nd Gen Modules
Remote Sense Compensation
OVP Set Point
50-110
%Vout
±10% on 10 – 15 Vout
10-110
0.5
%Vout
Vdc
Preload may be required
Autosense (See page 1)
Not available on 1st Gen Minis
125
%Vout
Current Limit
115
%Imax
Autorecovery
ENVIRONMENTAL CHARACTERISTICS
Parameter
Typ
Units
Notes
-20 to +100
-40 to +100
°C
°C
Standard version
Storage Temperature
Extended range option*
Operating Temperature(standard and extended)*
Ambient Air
-20 to +70
-20 to +90
°C
°C
See derating curves in Design Guide
75° for 1st Gen Maxi modules
Case Temperature
MIL-STD-810E, Category 10 Minimum
Integrity Test
Vibration
see note
Safety Approvals
cULus, TÜV, CE
*Extended temperature range option includes module burn-in and temperature cycling.
MECHANICAL CHARACTERISTICS
Parameter
Typ
Units
Notes
3.4
1.5
lbs
kg
Weight
9.2 x 5.0 x 1.4
in
L x W x H
L x W x H
Overall Dimensions
233,7 x 127,0 x 35,6
mm
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715 Westcor Division 408-522-5280
FlatPAC-EN
Rev. 1
Page 4 of 8
Set your site on VICOR at www.vicorpower.com
Mechanical Diagram
9.20
233,69
MBJ1 A/C INPUT
2
3
MATING CONNECTOR:
HOUSING: MOLEX (39-01-4051)
SOCKET CRIMP 16 AWG: MOLEX (39-00-0090)
CRIMP TOOL: MOLEX (11-01-0199)
1.40
35,59
MBJ1
GN
1
0.03
0,77
N/C
N/C
L2/N
L1
MOUNTING HOLES
MOUNTING HOLES
4X #8-32 x 0.250 OR M4 x 6mm MAX LG
FROM OUTSIDE OF POWER SUPPLY
4X #8-32 x 0.125 OR M4 x 3mm MAX LG
FROM OUTSIDE OF POWER SUPPLY
OUTPUTS
M1 & M2
J2
4.000
101,60
4.563
115,89
OUTPUTS
M3 & M4
J3
QUADRUPLE OUTPUT
See page 6 and 7 for detailed
output connection information.
AIR
FLOW
0.50
12,70
5.450
138,43
0.219
5,56
5.825
147,96
PIN 1
CBJ1 (12 PIN)
1
0.38
9,53
8.500
215,90
PIN
CBJ1
REF
DESCRIPTION
SGND
N/C
ACOK
TX
SIGNAL GROUND
N/C
AC POWER OK
CBJ1 E/D INTERFACE CONNECTOR
CBJ2
CBJ3
CBJ4
CBJ5
CBJ6
CBJ7
CBJ8
CBJ9
CBJ10
CBJ11
CBJ12
2
3
MATING CONNECTOR:
HOUSING: MOLEX (50-57-9412)
TRANSMIT
RECEIVE
4
RX
NOTES: UNLESS OTHERWISE SPECIFIED
SOCKET CRIMP 24-30 AWG: MOLEX (16-02-0097)
CRIMP TOOL: MOLEX (11-01-0209)
E/D-4
E/D-3
E/D-2
E/D-1
GSD
N/C
ENABLE/DISABLE
ENABLE/DISABLE
ENABLE/DISABLE
ENABLE/DISABLE
GENERAL SHUTDOWN
N/C
REFERENCE
DESIGNATION
1
MB
CB
MOTHER BOARD
CONTROL BOARD
2
3
CONNECTOR PART NUMBERS SPECIFIED ARE MOLEX OR
EQUIVALENT
+5VS
+5V @ 300mA
A COMPLETE SET OF MATING CONNECTORS CAN BE PURCHASED FROM WESTCOR
BY SPECIFYING CONNECTOR KIT P/N 19-130044
4
CBJ4 AND CBJ5 ARE PART OF THE RS-232 MICROCONTROLLER FUNCTIONS. SEE FLATPAC-EN
DESIGN GUIDE (AVAILABLE ONLINE AT VICORPOWER.COM) FOR DETAILED INFORMATION.
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715 Westcor Division 408-522-5280
FlatPAC-EN
Rev. 1
Page 5 of 8
Set your site on VICOR at www.vicorpower.com
FlatPAC-EN OUTPUT CONNECTORS
A. SINGLE OR DUAL OUTPUT
J1/J2 SENSE/TRIM
PIN CONNECTOR
MATING CONNECTOR:
HOUSING: MOLEX P/N 50-57-9403
TERMINALS: MOLEX P/N 16-02-0103
USE CRIMP TOOL: MOLEX P/N 11-01-0208
-V OUT
TRIM
1
2
3
10-32 OUTPUT STUDS
+ SENSE
- SENSE
10-32 STUDS
OUTPUT M1
OUTPUT M2
+V OUT
J2
J1
–
–
M1
M1
M2
M2
SINGLE OR DUAL OUTPUT
B. TRIPLE OUTPUT
Output M1 (Using 1 Mini)
J2
J2 (18 PIN OUTPUT, SENSE
AND TRIM PIN CONNECTOR)
MATING CONNECTOR:
18 PIN HOUSING: MOLEX (39-01-2180)
TERMINAL FEM CRIMP 18-24 AWG: MOLEX (39-00-0039)
USE CRIMP TOOL: MOLEX (11-01-0197)
9
8
7
6
5
4
18
17
16
15
14
13
12
PIN DESCRIPTION
PIN DESCRIPTION
1
2
3
4
5
6
7
8
9
N/C
10 N/C
N/C
11 N/C
N/C
12 N/C
OUTPUT M1
18
OUTPUTS M2 & M3
N/C
13 + SENSE M1
10
1
18
10
N/C
14
N/C
TRIM M1
+V OUT M1
+V OUT M1
-V OUT M1
15 - SENSE M1
16 +V OUT M1
17 - V OUT M1
18 - V OUT M1
3
2
J2
J3
9
9
1
11
10
TRIPLE OUTPUT
1
Outputs M2 and M3 (Using 2 Minis)
J3
J3 (18 PIN OUTPUT, SENSE
AND TRIM PIN CONNECTOR)
9
8
7
6
5
4
18
17
16
15
14
13
12
PIN DESCRIPTION
PIN DESCRIPTION
1
2
3
4
5
6
7
8
9
+V OUT M3
-V OUT M3
-V OUT M3
+ SENSE M3
- SENSE M3
TRIM M2
+V OUT M2
+V OUT M2
-V OUT M2
10 +V OUT M3
11 +V OUT M3
12 -V OUT M3
13 + SENSE M2
14 TRIM M3
15 - SENSE M2
16 +V OUT M2
17 - V OUT M2
18 - V OUT M2
3
2
11
10
1
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715 Westcor Division 408-522-5280
FlatPAC-EN
Rev. 1
Page 6 of 8
Set your site on VICOR at www.vicorpower.com
FLATPAC-EN OUTPUT CONNECTORS (continued)
C. QUADRUPLE OUTPUT
Outputs M1 and M2 (Using 2 Micros)
J2
MATING CONNECTOR:
J2 (18 PIN OUTPUT, SENSE
AND TRIM PIN CONNECTOR)
9
8
7
6
5
4
18
17
16
15
14
13
12
18 PIN HOUSING: MOLEX (39-01-2180)
TERMINAL FEM CRIMP 18-24 AWG: MOLEX (39-00-0039)
USE CRIMP TOOL: MOLEX (11-01-0197)
PIN DESCRIPTION PIN DESCRIPTION
1
2
3
4
5
6
7
8
9
+V OUT M2
-V OUT M2
-V OUT M2
+V OUT M2
- V OUT M2
TRIM M1
+V OUT M1
+V OUT M1
-V OUT M1
10 +V OUT M2
11 +V OUT M2
12 -V OUT M2
13 + V OUT M1
14 TRIM M2
15 - V OUT M1
16 +V OUT M1
17 - V OUT M1
18 - V OUT M1
10
18
18
10
J2
J3
3
2
1
9
9
1
11
10
OUTPUTS M1 & M2
OUTPUTS M3 & M4
1
QUADRUPLE OUTPUT
Outputs M3 and M4 (Using 1 Micro and 1 Mini)
J3
J3 (18 PIN OUTPUT, SENSE
AND TRIM PIN CONNECTOR)
9
8
7
6
5
4
18
17
16
15
14
13
12
PIN DESCRIPTION PIN DESCRIPTION
1
2
3
4
5
6
7
8
9
+V OUT M4
-V OUT M4
-V OUT M4
+ SENSE M4
- SENSE M4
TRIM M3
+V OUT M3
+V OUT M3
-V OUT M3
10 +V OUT M4
11 +V OUT M4
12 -V OUT M4
13 + V OUT M3
14 TRIM M4
15 - V OUT M3
16 +V OUT M3
17 - V OUT M3
18 - V OUT M3
3
2
11
10
1
Note: Additional technical information including temperature derating curves, installation
instructions, mounting holes, in-line filter, RS-232 microcontroller features
covered in the FlatPAC-EN Design Guide available online at vicorpower.com.
FLATPAC-EN ACCESSORIES
The following accessories are available for the FlatPAC-EN:
Connector Kits
FlatPAC-EN
19-130044
Current Share Boards
Used for increased output power or redundancy
FlatPAC-ENs with 1st Gen Modules
FlatPAC-ENs with 2nd Gen Modules
CSB01
CSB02
In-line Filter
In-line Filter
IF1232
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715 Westcor Division 408-522-5280
FlatPAC-EN
Rev. 1
Page 7 of 8
Set your site on VICOR at www.vicorpower.com
Vicor’s comprehensive line of power solutions includes high density AC-DC
and DC-DC modules and accessory components, fully configurable AC-DC
and DC-DC power supplies, and complete custom power systems.
Information furnished is believed to be accurate and reliable. However, no responsibility is assumed for its
use. No license is granted by implication or otherwise under any patent or patent rights. Products are not
designed to be used in applications, such as life support systems, wherein a failure or malfunction could
result in injury or death. All sales are subject to our standard Terms and Conditions of Sale, which are
available upon request.
Specifications are subject to change without notice.
The latest data is available on the Vicor website at vicorpower.com.
Westcor, a division of Vicor, designs and builds configurable power supplies incorporating Vicor’s high density DC-DC converters and accessory
components. Westcor’s product line includes:
• PFC Mini
• PFC Micro
• PFC MicroS
• Autoranging MegaPAC
• Mini MegaPAC
• PFC MegaPAC
• PFC MegaPAC-EL (/Low Noise)
• 3 Phase/4kW MegaPAC
• 3 Phase/4kW MegaPAC-EL (Low Noise)
• ConverterPACs
• FlatPAC-EN
See Design Guides for detailed information about all Westcor products. They can be downloaded in PDF format from the website.
Vicor Corporation
25 Frontage Road, Andover, MA, 01810
978-470-2900, Fax: 978-475-6715
Westcor Division of Vicor
560 Oakmead Parkway, Sunnyvale, CA 94085
800-735-6200, 408-522-5280, Fax: 408-774-5555
vicorpower.com
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715 Westcor Division 408-522-5280 FlatPAC-EN
P/N 26318 Rev. 1 3/03/10M
Set your site on VICOR at www.vicorpower.com