TFS1552 [VECTRON]
Filter specification; 过滤器规格型号: | TFS1552 |
厂家: | Vectron International, Inc |
描述: | Filter specification |
文件: | 总5页 (文件大小:137K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
Filename: tfs 1552.doc
Version 1.3
16.05.2006
VI TELEFILTER
Filter specification
TFS 1552
1/5
Measurement condition
Ambient temperature:
Input power level:
Terminating impedance: *
Input:
23
0
°C
dBm
138 Ω || -1,42 pF
138 Ω || -1,42 pF
Output:
Characteristics
Remark:
The minimum attenuation in the pass band is defined as the insertion loss a . The nominal frequency fN is fixed at 1552,0 MHz without any tolerance or
e
limit. The values of absolute attenuation a
temperature range is included in the production tolerance scheme.
are guaranteed for the whole operating temperature range. The frequency shift of the filter in the operating
abs
D a t a
typ. value
tolerance / limit
a
4,3
dB
max.
6,0
dB
Insertion loss
e
fN
-
1552,0
± 2,2
MHz
MHz
dB
Nominal frequency
Passband
PB
-
fN
1,2
dB
max.
2,0
Pass band ripple
Absolute attenuation
a
abs
1440
1559
MHz
MHz
…
…
1547
1600
MHz
MHz
20
dB
dB
min.
min.
9
dB
dB
31
28
-
23
ns
max.
max.
100
20
ns
Group delay ripple
Input power level
dBm
OTR
-
-
- 10 °C ... + 60 °C
Operating temperature range
Storage temperature range
- 45 °C ... + 85 °C
40
°C
-
-
Frequency inversion temperature
TC **
f
-0,051 ppm/K²
Temperature coefficient of frequency
*) The terminating impedances depend on parasitics and q-values of matching elements and the board used, and are to be understood as reference
values only. Should there be additional questions do not hesitate to ask for an application note or contact our design team.
**) ∆f(Hz) = TC (ppm/K²) x (T-T0)² x f (MHz).
f
To
Generated:
Checked / Approved:
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: tft@telefilter.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 1552.doc
Version 1.3
16.05.2006
VI TELEFILTER
Filter specification
TFS 1552
2/5
Filter characteristic
0
0
-1
0.3
-10
-20
-30
-40
-50
-60
-70
-80
-2
0.25
0.2
-3
-4
-5
-6
0.15
0.1
-7
-8
-9
-10
0.05
1510 1520 1530 1540 1550 1560 1570 1580 1590 1600
1548
1549
1550
1551
1552
1553
1554
1555
1556
frequency in MHz
Construction and pin connection
(All dimensions in mm)
frequency in MHz
1
2
3
4
5
6
7
8
Ground
Input
Ground
Ground
Ground
Output
Ground
Ground
G52
● U20
Date code: Year + week
U
V
W
...
2006
2007
2008
50 Ohm Test circuit
2
6
1, 3, 4, 5, 7, 8
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: tft@telefilter.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 1552.doc
Version 1.3
16.05.2006
VI TELEFILTER
Filter specification
TFS 1552
3/5
Stability characteristics, reliability
After the following tests the filter shall meet the whole specification:
1. Shock:
500g, 1 ms, half sine wave, 3 shocks each plane;
DIN IEC 68 T2 - 27
2. Vibration:
10 Hz to 500 Hz, 0,35 mm or 5 g respectively, 1 octave per min, 10 cycles per plan, 3 plans;
DIN IEC 68 T2 - 6
3. Change of
temperature:
-55 °C to 125°C / 30 min. each / 10 cycles
DIN IEC 68 part 2 – 14 Test N
4. Resistance to
solder heat (reflow):
reflow possible: twice max.;
for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4;
This filter is RoHS compliant (2002/95/EG, 2005/618/EG)
Packing
Tape & Reel:
IEC 286 – 3, with exeption of value for N and minimum bending radius;
tape type II, embossed carrier tape with top cover tape on the upper side;
max. pieces of filters peer reel:
reel of empty components at start:
reel of empty components at start including leader:
trailer:
9000
min. 300 mm
min. 500 mm
min. 300 mm
Pull Off Direction
P1
Tape (all dimensions in mm)
Date Code
W
:
:
:
:
:
:
:
:
:
:
:
:
8,00 ± 0,3
4,00 ± 0,1
1,50 +0,1/-0
1,75 ± 0,1
3,50 ± 0,05
0,75
Po
P2
t
Do
Po
Do
E
F
G(min)
P2
P1
D1(min)
Ao
Bo
2,00 ± 0,05
4,00 ± 0,1
1,50
3,25 ± 0,1
3,25 ± 0,1
5,5 ± 0,1
Ko
Typ
PIN Marker
D1
Ao
Ct
W
2
Reel (all dimensions in mm)
A
W1
:330
: 8,4 +1,5/-0
W2(max) : 14,4
N(min)
C
: 50
: 13,0 +0,5/-0,2
C
A
N
W
1
The minimum bending radius is 45 mm.
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: tft@telefilter.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 1552.doc
Version 1.3
16.05.2006
VI TELEFILTER
Filter specification
TFS 1552
4/5
Air reflow temperature conditions
Conditions
Exposure
Average ramp-up rate (30°C to 217°C)
> 100°C
less than 3°C/second
between 300 and 600 seconds
> 150°C
> 217°C
Peak temperature
between 240 and 500 seconds
between 30 and 150 seconds
max. 260°C
Time within 5°C of actual peak temperature
Cool-down rate (Peak to 50°C)
Time from 30°C to Peak temperature
between 10 and 30 seconds
less than 6°C/second
no greater than 300 seconds
Chip-mount air reflow profile
Temperature / °C
max. 260°C
217°C
Time / s
max. 300 s
10 ... 30 s
30 ... 150 s
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: tft@telefilter.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 1552.doc
Version 1.3
16.05.2006
VI TELEFILTER
Filter specification
TFS 1552
5/5
History
Version
1.0
Reason of Changes
- Generation of development specification
Name
Date
Channaa
Strehl
01.12.2005
07.12.2005
17.01.2006
1.1
- loss goal added
1.2
- Change absolute attenuation
Strehl
1.3
- Change limit line scheme and test circuit
Add typical values and filter characteristic
Generation of filter specification
Noack
15.05.2006
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: tft@telefilter.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
相关型号: