TFS155A [VECTRON]
Filter specification; 过滤器规格型号: | TFS155A |
厂家: | Vectron International, Inc |
描述: | Filter specification |
文件: | 总5页 (文件大小:134K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
Filename: tfs 155a.doc
Version 1.3
02.02.2005
VI TELEFILTER
Filter specification
TFS 155A
1/5
Measurement condition
Ambient temperature:
Input power level:
Terminating impedance: *
Input:
23
0
°C
dBm
760 Ω || -1,95 pF
760 Ω || -1,95 pF
Output:
Characteristics
Remark:
The reference level for the relative attenuation a of the TFS155A is the maximum attenuation in the pass band. The maximum attenuation in the pass
rel
band is defined as the insertion loss a . The nominal frequency fN is fixed at 155,52 MHz MHz without any tolerance or limit. The values of relative
e
attenuation a are guaranteed for the whole operating temperature range. The frequency shift of the filter in the operating temperature range is included
rel
in the production tolerance scheme.
D a t a
typ. value
tolerance / limit
a
-
-
max.
5
-
dB
Insertion loss
(reference level)
e
fN
155,525 MHz
-
155,52 MHz
Nominal frequency
min.
± 10
kHz
Usable Signal Bandwidth
Relative attenuation
a
rel
fN
fN
+
±
910
3
kHz
MHz fN
67
62
dB
dB
min.
min.
60
50
dB
dB
±
10 MHz
25
°C
-
-
Frequency inversion temperature
TC **
f
-0,036 ppm/K²
Temperature coefficient of frequency
OTR
-
-
- 10 °C … + 50
- 40 °C ... + 85
°C
°C
Operating temperature range
Storage temperature range
*) The terminating impedances depend on parasitics and q-values of matching elements and the board used, and are to be understood as reference
values only. Should there be additional questions do not hesitate to ask for an application note or contact our design team.
**) ∆f(Hz) = TC (ppm/K) x (T-T0)² x f (MHz).
f
To
Generated:
Checked / Approved:
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: tft@telefilter.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 155a.doc
Version 1.3
02.02.2005
VI TELEFILTER
Filter specification
TFS 155A
2/5
Filter characteristic
0
-10
-20
-30
-40
-50
-60
-70
-80
-90
-100
0
-5
-10
-15
154.6 154.8 155 155.2 155.4 155.6 155.8 156 156.2 156.4
155.4
155.45
155.5
155.55
155.6
155.65
frequency in MHz
frequency in MHz
Construction and pin connection
(All dimensions in mm)
1
2
3
4
5
6
7
8
9
10
Ground
Output
Ground
Ground
Ground
Output
Input
Ground
Ground
Ground
TFS 155A
●
T06
Date code: Year + week
T
2005
2006
2007
U
V
...
50 Ohm Test circuit 1
7
2
1, 3, 4, 5, 6, 8, 9, 10
50 Ohm Test circuit 2
7
2
1, 3, 4, 5, 6, 8, 9, 10
Stability Characteristics
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: tft@telefilter.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 155a.doc
Version 1.3
02.02.2005
VI TELEFILTER
Filter specification
TFS 155A
3/5
After the following tests the filter shall meet the whole specification:
1. Shock:
500g, 18 ms, half sine wave, 3 shocks each plane;
DIN IEC 68 T2 - 27
2. Vibration:
10 Hz to 500 Hz, 0,35 mm or 5g respectively, 1 octave per min, 10 cycles per plan, 3 plans;
DIN IEC 68 T2 - 6
3. Damp heat:
(cycle)
25 °C to 55°C / 95% r.H. / 10 cycles
DIN IEC 68 - 2 – 30 Db
4. Resistance to
solder heat (reflow):
reflow possible: twice max.;
for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4;
Packing
Tape & Reel:
IEC 286 - 3, with exception of value for N and minimum bending radius;
tape type II, embossed carrier tape with top cover tape on the upper side;
max. pieces of filters per reel:
reel of empty components at start:
reel of empty components at start including leader:
trailer
2000
min 300 mm
min 500 mm
min 300 mm
Tape (all dimensions in mm)
EMBOSSED CARRIER TAPE
W
Po
Do
E
:
:
:
:
:
16
4
± 0,3
± 0,1
Po
P 2
D
o
1,5 + 0,1
1,75 ± 0,1
7,5 ± 0,1
0,6
E
F
Ao
F
D 1
G (min) :
CT
W
Bo
P2
P1
:
2
± 0,1
:
12 ± 0,1
G
D1(min) : 1,5
Ao
Bo
CT
:
:
7,6 ± 0,1
9,6 ± 0,1
13,5 + 0,1
P1
COVER TAPE
:
W
2
Reel (all dimensions in mm):
A
:
330
W1
:
16,4 +2
22,4
W2 (max) :
N (min)
C
:
60
C
A
:
12,8 ± 0,1
N
W
1
The minimum bending radius is 45 mm.
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: tft@telefilter.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 155a.doc
Version 1.3
02.02.2005
VI TELEFILTER
Filter specification
TFS 155A
4/5
Air reflow temperature conditions
Conditions
Exposure
Average ramp-up rate (30°C to 217°C)
> 100°C
less than 3°C/second
between 300 and 600 seconds
between 240 and 500 seconds
between 30 and 150 seconds
max. 260°C
> 150°C
> 217°C
Peak temperature
Time within 5°C of actual peak temperature
Cool-down rate (Peak to 50°C)
Time from 30°C to Peak temperature
between 10 and 30 seconds
less than 6°C/second
no greater than 300 seconds
Chip-mount air reflow profile
Temperature / °C
max. 260°C
217°C
Time / s
max. 300 s
10 ... 30 s
30 ... 150 s
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: tft@telefilter.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 155a.doc
Version 1.3
02.02.2005
VI TELEFILTER
Filter specification
TFS 155A
5/5
History
Version
1.1
Reason of Changes
Name
Date
- Generation of specification according to customer requirement specification.
Dr. Wall
Dr. Wall
03.05.2001
23.05.2002
1.2
- Add termination impedances.
- Add typical data.
1.3
- Changed reflow profile, changed marking
Martens
02.02.2005
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: tft@telefilter.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
相关型号:
©2020 ICPDF网 联系我们和版权申明