Measurement condition
Ambient temperature:
Input power level:
23
0
C
dBm
Terminating impedance’s : 50
Characteristics
Remark:
Reference level for the relative attenuation a of the TFS 125K is the maximum attenuation in the pass band. The maximum attenuation in the
rel
pass band is defined as the insertion loss a . The nominal frequency fN is fixed at 125 MHz without tolerance or limit. The values of relative
e
attenuation a
are guaranteed in the whole operating temperature range. The frequency shift of the filter in the operating temperature range is
rel
included in the production tolerance scheme.
D a t a
typ. value
tolerance / limit
Insertion loss
a
1,88 dB
2,5 1,0 dB
e
(Reference level)
Nominal frequency
1 dB band width
Pass band ripple within
Relative attenuation
fN
fN
-
125
300
MHz
BW
2,80 MHz
0,10 dB
kHz
100KHz
max.
0,20 dB
a
rel
150 kHz
-
max.
min.
1
5
dB
fN -
fN -
14 MHz... fN
28 MHz... fN
14 MHz... fN
23 MHz... fN
33 MHz... fN
-
-
28 MHz
124 MHz
23 MHz
33 MHz
325 MHz
50
65
40
55
42
dB
dB
dB
dB
dB
dB
dB
dB
dB
dB
min. 12
min. 30
min. 44
min. 38
fN
fN
fN
+
+
+
+
+
+
VSWR
f
-
150 kHz ... fN
+
150 kHz
1.3:1
max
2 : 1
N
Absolute group delay
fN 150 kHz ... fN
Group delay ripple
fN 150 kHz ... fN
GD*)
-
+
+
150 kHz
245
15
ns
ns
max. 300
max. 100
ns
ns
GDR *)
-
150 kHz
Intermodulation
**)
IP3
54
dB
min. 45
max 10
dB
dBm
Input power level
Temperature coefficient of frequency
TC ***)
- 72
-
ppm/K
-
f
Operating temperature range
Storage temperature range
- 10 °C ... + 85 °C
- 30°C ... + 85 C
*) measured with smoothing; smoothing aperture 50 kHz
**) modulation signals: fN and fN + 14 MHz, each of 10 dBm; measured signal: fN - 14 MHz
***) f(Hz) = TC (ppm/K) x ( T) x f (MHz)
f
To
generated:
checked / approved:
TELEFILTER GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: tft@telefilter.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
TFS125K.doc
Version 1.2
18.06.2003
VI TELEFILTER
Filter Specification
TFS 125K
2 / 5
Construction and pin connection
(All dimensions in mm)
9,3 Max.
8
7
6
3
1
2
3
4
5
6
7
8
Ground
Ground
Ground
Ground
Output
Ground
Ground
Ground
Ground
Input
5
4
9
TFS125K
10
1
2
Date code
9
10
Date code: Year+week
2,54 ±0,12,54 ±0,1
0,10
N
P
R
2001
2002
2003
2
3
1
...
4
5
10
9
7
8
6
0,8
7,1
TELEFILTER GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: tft@telefilter.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
TFS125K.doc
Version 1.2
18.06.2003
VI TELEFILTER
Filter Specification
TFS 125K
3 / 5
Stability Characteristics
After the following tests the filter shall meet the whole specification:
1. Shock:
500g, 18 ms, half sine wave, 3 shocks each plane;
DIN IEC 68 T2 - 27
2. Vibration:
10 Hz to 500 Hz, 0,35 mm or 5g respectively, 1 octave per min, 10 cycles per plan, 3 plans;
DIN IEC 68 T2 - 6
3. Change of
temperature:
-55 °C to 125°C / 30 min. each / 10 cycles
DIN IEC 68 part 2 – 14 Test N
4. Resistance to
solder heat (reflow):
reflow possible: twice max.;
for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4;
Packing
Tape & Reel:
IEC 286 - 3, with exception of value for N and minimum bending radius;
tape type II, embossed carrier tape with top cover tape on the upper side;
max. pieces of filters per reel:
Reel of empty components at start:
Reel of empty components at start including leader:
Trailer
3000
min 300 mm
min 500 mm
min 300 mm
Tape (all dimensions in mm)
EMBOSSED CARRIER TAPE
W
Po
Do
E
:
16
4
± 0,3
± 0,1
:
Po
P
2
Do
:
1,5 + 0,1
1,75 ± 0,1
7,5 ± 0,1
0,6
E
F
:
A
o
F
:
D
1
G (min) :
CT
W
Bo
P2
P1
:
2
8
± 0,1
± 0,1
:
G
D1(min) : 1,5
Ao
:
:
5,3 ± 0,1
P
1
Bo
CT
9,7 ± 0,1
COVER TAPE
:
13,5 + 0,1
W
2
Reel (all dimensions in mm):
A
:
330
W1
:
16,4 +2
22,4
W2 (max) :
N (min)
C
:
50
C
A
:
13 + 0,5 / - 0,2
N
W
1
The minimum bending radius is 45 mm. The mounting surface of the filters faces the bottom side of the embossed carrier tape.
Markings on the filters can be read if the upper side of the carrier tape is regarded with the sprocket holes on its right.
TELEFILTER GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: tft@telefilter.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
TFS125K.doc
Version 1.2
18.06.2003
VI TELEFILTER
Filter Specification
TFS 125K
4 / 5
Air reflow temperature conditions
1st and 2nd air reflow profile
Name: pre-heating periods
main-heating periods
over 200 °C
peak temperature
255 °C ± 5 °C
Temperature: 150 °C - 170 °C
Time:
60 sec. - 90 sec.
20 sec. - 25 sec.
Chip-mount air reflow profile
260
240
220
200
180
160
140
120
100
80
60
40
20
0
0
20
40
60
80
100
120
140
160
180
200
220
240
time / sec.
Table for temperature vs. time during the air reflow process
Tolerance of temperatures: ± 5 °C
time / sec.
0
10
20
30
40
50
60
70
80
90
100
110
120
130
temperature / °C
time / sec.
140
150
160
170
180
190
195
200
205
210
215
220
230
240
temperature / °C
23
34
46
60
80
103
121
134
143
150
154
156
158
159
160
161
164
170
180
205
230
255
230
205
180
165
140
120
TELEFILTER GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: tft@telefilter.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
TFS125K.doc
Version 1.2
18.06.2003
VI TELEFILTER
Filter Specification
TFS 125K
5 / 5
History
Version
Reason of Changes
Name
Date
1.0
- generation of development specification according to the
customer specification (V-1.0.0; 15 Jan 03)
Dr. Sabah
Dr. Sabah
07.03.03
1.1
1.2
- add of typical values and generation of filter specification
03.06.03
17.06.03
- updated of filter specification according to customer specification, version 2.0.0 Dr. Sabah
TELEFILTER GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: tft@telefilter.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
相关型号:
©2020 ICPDF网 联系我们和版权申明