UT137GL-6-TA3-T [UTC]
TRIAC;![UT137GL-6-TA3-T](http://pdffile.icpdf.com/pdf2/p00226/img/icpdf/UT137GL-6-TA_1325833_icpdf.jpg)
型号: | UT137GL-6-TA3-T |
厂家: | ![]() |
描述: | TRIAC 三端双向交流开关 |
文件: | 总6页 (文件大小:297K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
![](http://public.icpdf.com/style/img/ads.jpg)
UNISONIC TECHNOLOGIES CO., LTD
UT137F/G
TRIAC
TRIAC
DESCRIPTION
Passivated triacs in a plastic envelope, intended for use in
applications requiring high bidirectional transient and blocking
voltage capability and high thermal cycling performance.
Typical applications include motor control, industrial and
domestic lighting, heating and static switching.
SYMBOL
ORDERING INFORMATION
Order Number
Lead Free
Pin Assignment
Package
Packing
Halogen Free
1
2
3
UT137FL-x-TA3-T
UT137GL-x-TA3-T
UT137FG-x-TA3-T
UT137GP-x-TA3-T
TO-220
TO-220
MT1
MT1
MT2
MT2
G
G
Tube
Tube
Note: Pin Assignment: G: Gate
UT137FL- x -TA3-T
(1) T: Tube
(2) TA3: TO-220
(3) 5: 500V, 6: 600V, 8: 800V
(1)Packing Type
(2)Package Type
(3)Peak Voltage
(4)Green Package
(4) L: Lead Free, G: Halogen Free and Lead Free
P: Halogen Free and Lead Free
MARKING
UT137F
UT137G
www.unisonic.com.tw
Copyright © 2015 Unisonic Technologies Co., Ltd
1 of 6
QW-R401-014.C
UT137F/G
TRIAC
ABSOLUTE MAXIMUM RATING
PARAMETER
Repetitive peak off-state voltages
SYMBOL
VDRM
RATINGS
UNIT
UT137F_G-5
UT137F_G-6
UT137F_G-8
500 (Note 2)
V
V
V
A
600 (Note 2)
800
RMS on-state current full sine wave; Tmb ≤102°C
IT(RMS)
ITSM
I2t
8
t = 20ms
Non-repetitive peak on-state current
(Full sine wave; TJ = 25°C prior to surge)
I2t for fusing
65
A
t = 16.7 ms
t = 10 ms
T2+ G+
T2+ G-
71
21
A2s
A/μs
A/μs
A/μs
A/μs
V
50
Repetitive rate of rise of on-state current
after triggering
50
dIT /dt
T2- G-
50
I
TM=12A; IG=0.2A; dIG /dt=0.2A/μs
T2- G+
10
Peak gate voltage
VGM
IGM
5
Peak gate current
2
A
Peak gate power
PGM
PG(AV)
TJ
5
0.5
W
Average gate power (over any 20 ms period)
Junction Temperature
Storage Temperature
W
125
°C
TSTG
-40 ~ +150
°C
Note: 1. Absolute maximum ratings are those values beyond which the device could be permanently damaged.
Absolute maximum ratings are stress ratings only and functional device operation is not implied.
2. Although not recommended, off-state voltages up to 800V may be applied without damage, but the triac
may switch to the on-state. The rate of rise of current should not exceed 6A/μs.
THERMAL RESISTANCES
PARAMETER
SYMBOL
MIN
TYP
60
MAX
UNIT
°C/W
°C/W
°C/W
Thermal resistance Junction to Ambient
Thermal resistance Junction to mounting
base
In Free Air
Full cycle
Half cycle
θJA
2.0
2.4
θJC
STATIC CHARACTERISTICS (TJ =25°C, unless otherwise specified)
MAX
UT137F UT137G
PARAMETER
SYMBOL
TEST CONDITIONS
T2+G+
MIN
TYP
UNIT
mA
5
8
25
25
25
70
30
45
30
45
20
50
50
50
100
45
60
45
60
40
T2+G-
T2-G-
T2-G+
T2+G+
T2+G-
T2-G-
T2-G+
Gate Trigger Current
Latching Current
IGT
VD=12V, IT=0.1A
11
30
7
16
5
IL
VD=12V, IGT=0.1A
mA
7
Holding Current
On-State Voltage
IH
VD=12V, IGT=0.1A
IT=10A
5
mA
V
VT
1.3
0.7
0.4
0.1
1.65
1.5
VD=12V, IT=0.1A
V
Gate Trigger Voltage
VGT
ID
VD=400V, IT=0.1A, TJ=125°C 0.25
VD=VDRM(max), TJ=125°C
V
Off-State Leakage Current
0.5
mA
UNISONIC TECHNOLOGIES CO., LTD
2 of 6
QW-R401-014.C
www.unisonic.com.tw
UT137F/G
TRIAC
DYNAMIC CHARACTERISTICS (TJ =25°C, unless otherwise specified)
MIN
PARAMETER
SYMBOL
dVD/dt
TEST CONDITIONS
TYP MAX UNIT
UT137F UT137G
Critical Rate Of Rise Of
Off-State Voltage
Critical Rate Of Change
Of Commutating
Voltage
V
DM=67% VDRM(max), TJ=125°C,
Exponential waveform, gate open circuit
50
200
250
20
2
V/μs
V/μs
μs
V
DM=400V, TJ=95°C, IT(RMS)=8A,
dIcom/dt=3.6A/ms, gate open circuit
dVcom/dt
10
Gate Controlled
Turn-On Time
I
TM=12A, VD=VDRM(max), IG=0.1A,
dIG/dt=5A/μs
tgt
UNISONIC TECHNOLOGIES CO., LTD
3 of 6
QW-R401-014.C
www.unisonic.com.tw
UT137F/G
TRIAC
TYPICAL CHARACTERISTICS
UNISONIC TECHNOLOGCO., LTD
4 of 6
QW-R401-014.C
www.unisonic.com.tw
UT137F/G
TRIAC
TYPICAL CHARACTERISTICS(Cont.)
UNISONIC TECHNOLOGIES CO., LTD
5 of 6
QW-R401-014.C
www.unisonic.com.tw
UT137F/G
TRIAC
UTC assumes no responsibility for equipment failures that result from using products at values that
exceed, even momentarily, rated values (such as maximum ratings, operating condition ranges, or
other parameters) listed in products specifications of any and all UTC products described or contained
herein. UTC products are not designed for use in life support appliances, devices or systems where
malfunction of these products can be reasonably expected to result in personal injury. Reproduction in
whole or in part is prohibited without the prior written consent of the copyright owner. The information
presented in this document does not form part of any quotation or contract, is believed to be accurate
and reliable and may be changed without notice.
UNISONIC TECHNOLOGIES CO., LTD
6 of 6
QW-R401-014.C
www.unisonic.com.tw
©2020 ICPDF网 联系我们和版权申明