Description
The MIM-5xx3K8 is miniaturized infrared receivers for
remote control and other applications requiring improved
ambient light rejection.
The separate PIN diode and preamplifier IC are assembled
on a single leadframe.
The epoxy package contains a special IR filter.
This module has excellent performance even in disturbed
ambient light applications and provides protection against
uncontrolled output pulses.
Features
l Photo detector and preamplifier in one package
l Internal filter for PCM frequency
l High immunity against ambient light
l Improved shielding against electric field disturbance
l 5.0-Volt supply voltage; low power consumption
l TTL and CMOS compatibility
MIM-5xx3K8 Series Models
l MIM-5303K8 30.0KHz
l MIM-5333K8 33.0KHz
l MIM-5363K8 36.0KHz
l MIM-5373K8 36.7KHz
l MIM-5383K8 38.0KHz
l MIM-5403K8 40.0KHz
l MIM-5443K8 44.0KHz
l MIM-5563K8 56.0KHz
BLOCK DIAGRAM
VS
CGA &
filter
Demodulator
μ C
Input
AGC / ATC & digital
control
Oscillator
GND
REV: A1
Unity Opto Technology Co., Ltd.
12/09/2003
INFRARED RECEIVER MODULE
MIM-5xx3K8
@ Ta=25oC
Absolute Maximum Ratings
Item
Symbol
VCC
Is
Ratings
-0.3 ~ 6.0
5.0
Unit
V
Remark
Supply voltage
Supply Current
mA
oC
oC
Topr
Tstg
Operating temperature
Storage temperature
-25 ~ + 85
-25 ~ + 85
260
Soldering temperature
Power dissipation at Ta=25oC
oC
t≦5 s, 1mm from case
Tsd
Ptot
30
mW
Electro-optical characteristics (Vcc=5.0V)
Parameter
Supply Voltage
Symbol
Vs
Min.
Typ.
5.0
Max.
5.5
Unit
V
Remarks
4.5
Current consumption
Response wavelength
Output form
Icc
1.4
2.0
mA
nm
Under no signal
λp
940
- - - - - active low output - - - - -
V0h
V0l
Twh
Twl
L1
H level output voltage
L level output voltage
H level output pulse width
L level output pulse width
Distance between emitter & detector
Half angle
4.2
V
V
0.5
400
400
800
800
µs
µs
m
10.0
Note 1
∆θ
±45
deg
Horizonal direction
Test Method
A. Standard Transmitter
600µs
carrier frequency f0
duty 50%
ON/OFF pulse width satisfied from
600µs
600µs
25 cm to detection limit
Fig 1. Burst Wave
25cm
+5.0V
10kΩ
10µF
Transmitter
Duty 50%
Vout
GND
Oscilloscope
Fig 2. Standard Transmitter Measurement circuit
REV: A1
12/09/2003
Unity Opto Technology Co., Ltd.
INFRARED RECEIVER MODULE
MIM-5xx3K8
B. Detection Length Test
θ
Vout
Transmitter output
θ
D.U.T
θ: indicates horizontal and vertical directions
L
C . Pulse Width Test
Transmitter output
DUT output pulse
600µs 600µs
Twl
Twh
V0h
V0l
Application Circuit
100Ω*)
Vcc (+5V)
3
4.7μF *)
MIM-5xx3K8
>10kΩ
optional
MIE-544A2
μC
1
2
GND
*) recommended to suppress power supply disturbances
REV: A1
Unity Opto Technology Co., Ltd.
12/09/2003
INFRARED RECEIVER MODULE
MIM-5xx3K8
Dimensions in mm
REV: A1
Unity Opto Technology Co., Ltd.
12/09/2003
INFRARED RECEIVER MODULE
MIM-5xx3K8
CHARACTERISTIC CURVES (TA=25oC)
900
800
700
600
500
400
1.8
Burst length * 600µs, cycle =
1.2ms tpw: Average value of
output from start of signal input
1.6
1.4
1.2
1.0
0.1
6
1
10
100
3
4
5
7
1000
Input Level (mVp-p
)
Supply Voltage Vcc (V)
INPUT LEVEL vs.OUTPUT PULSE WIDTH
SUPPLY VOLTAGE vs. SUPPLY
CURRENT
0∘
15∘
1
30∘
45∘
0.8
1.0
0.8
0.6
0.4
0.2
0
60∘
75∘
0.6
750
850
950
1050
1150
0.4
0.2
0
0.1 0.3
λ - Wavelength (nm)
RELATIVE TRANIMISSION
RELATIVE SPECTRAL SENSITIVITY vs
WAVELENGTH
1
0.8
0.6
0.4
0.2
0
f=fo±5%
Δf(3dB) = fo/7
0.7
0.8
0.9
1
1.1
1.2
1.3
f/fo - Relative Frequency
FREQUENCY DEPENDENCE OF
RESPONSIVITY
REV: A1
Unity Opto Technology Co., Ltd.
12/09/2003
INFRARED RECEIVER MODULE
MIM-5xx3K8
Reliability
Test item
High temparature
High temp. & high humi.
Low temparature
Temperature cycle
Dropping
Test condition
Standard
Ta=+80oC
Ta=+40oC 90%RH
Ta= -30oC
t=240H
t=240H
t=240H
Note 2.
Note 2.
Note 2.
Note 2.
Note 3.
-30oC(0.5H) ~ +80oC(0.5H) 20cycle
Test devices shall be dropped 3 times naturally
onto hard wooden board from a 75cm height position.
NOTE 1. Distance between emitter & detector specifies maximum distance that output wave form satisfies
the standard under the conditions below against the standerd transmitter.
(1)Measuring place ………Indoor without extreme reflection of light.
(2)Ambient light source… Detecting surface illumination shall be 200±50Lux under ordinary
hite fluorescense lamp of no high frequency lighting.
(3)Standard transmitter … Burst wave indicated in Fig 1. of standard transmitter
shall be arranged to 50mVp-p under the measuring circuit specified in Fig 2.
NOTE 2. (electro-optical charactistics) shall be satisfied after leaving 2 hours in the normal temperature .
NOTE 3. (electro-optical charactistics) shall be satisfied and no conoid deforms
and destructions of appearance .(excepting deforms of terminals)
Inspection standard
1.Among electrical characteristics , total number shall be inspected on items blow.
1-1 front distance between emitter & detector
1-2 Current consumption
1-3 H level output voltage
1-4 L level output voltage
2.Items except above mentioned are not inspected particularly , but shall fully satisfy
CAUTION ( When use and storage of this device )
1.Store and use where there is no force causing transformation or change in quality .
2.Store and use where there is no corrosive gas or sea(salt) breeze .
3.Store and use where there is no extreme humidity .
4.Solder the lead-pin within the condition of ratings. After soldering do not add extra force .
5.Do not wash this device . Wipe the stains of diode side with a soft cloth. You can
use the solvent , ethylalcohol or methylalcohol or isupropylene only .
6.To prevent static electricity damage to the Pre-AMP make sure that the human body
, the soldering iron is connected to ground before using .
7.Put decoupling device between Vcc and GND for reduse the noise from power supply line .
8.The performance of remote-control system depends on environments condition and ability
of periferal parts. Customer should evaluate the performance as total system in those conditions
after system up with components such as commander , micon and this receiver module .
Others
1.This device is not design to endure radiative rays and heavily charged particles .
2.In case where any trouble or questions arise,both parties agress to make full discussion
covering the said problem .