HIGH-PERFORMANCE IMPACT-Xꢀ™ PROGRAMMABLE ARRAY LOGIC CIRCUITS
SRPS013A − D2943, FEBRUARY 1987 − REVISED DECEMBER 2010
C SUFFIX . . . NT PACKAGE
M SUFFIX . . . JT PACKAGE
• Functionally Equivalent to the
TIBPAL22V10/10A, with Additional
Feedback Paths in the Output Logic
Macrocell
(TOP VIEW)
CLK/I
VCC
1
24
23
22
21
20
19
18
17
16
15
14
13
I
I
I
I
I
I
I
I
I/O/Q
I/O/Q
I/O/Q
I/O/Q
I/O/Q
I/O/Q
I/O/Q
I/O/Q
I/O/Q
I/O/Q
I
2
• Choice of Operating Speeds:
TIBPAL22VP10-20C . . . 20 ns Max
TIBPAL22VP10-25M . . . 25 ns Max
3
4
5
• Variable Product Term Distribution
Allows More Complex Functions to Be
Implemented
6
7
8
9
• Each Output Is User Programmable for
Registered or Combinational Operation,
Polarity, and Output Enable Control
I
I
10
11
12
GND
• TTL-Level Preload for Improved Testability
• Extra Terms Provide Logical Synchronous
C SUFFIX . . . FN PACKAGE
M SUFFIX . . . FK PACKAGE
Set and Asynchronous Reset Capability
(TOP VIEW)
• Fast Programming, High Programming
Yield, and Unsurpassed Reliability Ensured
Using Ti-W Fuses
• AC and DC Testing Done at the Factory
4
3
2
1
28 27 26
25
5
6
7
8
9
I
I
I
I/O/Q
I/O/Q
I/O/Q
Utilizing Special Designed-In Test Features
24
23
• Dependable Texas Instruments Quality and
Reliability
NC
22 NC
I
I
I
• Package Options Include Plastic
21 I/O/Q
20 I/O/Q
19 I/O/Q
10
11
Dual-In-Line and Chip Carrier Packages
12 13 14 15 16 17 18
description
The TIBPAL22VP10’ is equivalent to the
TIBPAL22V10A but offers additional flexibility in
the output structure. The improved output
macrocell uses the registered outputs as inputs
when in a high-impedance condition. This
provides two additional output configurations for a
total of six possible macrocell configurations all of
which are shown in Figure 1.
NC − No internal connection
Pin assignments in operating mode
These devices contain up to 22 inputs and 10 outputs. They incorporate the unique capability of defining and
programming the architecture of each output on an individual basis. Outputs may be registered or nonregistered
and inverting or noninverting. In addition, the data may be fed back into the array from either the register or the
I/O port. The ten potential outputs are enabled through the use of individual product terms.
Further advantages can be seen in the introduction of variable product term distribution. This technique
allocates from 8 to 16 logical product terms to each output for an average of 12 product terms per output. This
variable allocation of terms allows far more complex functions to be implemented than in previously available
devices.
IMPACT-X is a trademark of Texas Instruments Incorporated.
PRODUCTION DATA information is current as of publication date.
Copyright © 2010, Texas Instruments Incorporated
Products conform to specifications per the terms of Texas Instruments
standard warranty. Production processing does not necessarily include
testing of all parameters.
POST OFFICE BOX 655303 • DALLAS, TEXAS 75265
1
Obsolete Device
TIBPAL22VP10-20C, TIBPAL22VP10-25M
HIGH-PERFORMANCE IMPACT-Xꢀ™ PROGRAMMABLE ARRAY LOGIC CIRCUITS
SRPS013A − D2943, FEBRUARY 1987 − REVISED DECEMBER 2010
description (continued)
Circuit design is enhanced by the addition of a synchronous set and an asynchronous reset product term. These
functions are common to all registers. When the synchronous set product term is a logic 1, the output registers
are loaded with a logic 1 on the next low-to-high clock transition. When the asynchronous reset product term
is a logic 1, the output registers are loaded with a logic 0. The output logic level after set or reset depends on
the polarity selected during programming. Output registers can be preloaded to any desired state during testing.
Preloading permits full logical verification during product testing.
With features such as programmable output logic macrocells and variable product term distribution, the
TIBPAL22VP10’ offers quick design and development of custom LSI functions with complexities of 500 to 800
equivalent gates. Since each of the ten output pins may be individually configured as inputs on either a
temporary or permanent basis, functions requiring up to 21 inputs and a single output or down to 12 inputs and
10 outputs are possible.
A power-up clear function is supplied that forces all registered outputs to a predetermined state after power is
applied to the device. Registered outputs selected as active-low power-up with their outputs high. Registered
outputs selected as active-high power-up with their outputs low.
A single security fuse is provided on each device to discourage unauthorized copying of fuse patterns. Once
blown, the verification circuitry is disabled and all other fuses will appear to be open.
The TIBPAL22V10-20C is characterized for operation from 0°C to 75°C. The TIBPAL22V10-25M is
characterized for operation over the full military temperature range of −55°C to 125°C.
POST OFFICE BOX 655303 • DALLAS, TEXAS 75265
2
Obsolete Device
TIBPAL22VP10-20C, TIBPAL22VP10-25M
HIGH-PERFORMANCE IMPACT-Xꢀ™ PROGRAMMABLE ARRAY LOGIC CIRCUITS
SRPS013A − D2943, FEBRUARY 1987 − REVISED DECEMBER 2010
functional block diagram (positive logic)
C1
1S
Set
&
Reset
44 x 132
R
8
1
Output
Logic
I/O/Q
Macrocell
EN
10
12
14
16
16
14
12
10
8
I/O/Q
I/O/Q
I/O/Q
I/O/Q
I/O/Q
I/O/Q
I/O/Q
I/O/Q
I/O/Q
22
EN
EN
EN
EN
EN
EN
EN
EN
EN
CLK/I
11
10
22
I
10
10
10
denotes fused inputs
POST OFFICE BOX 655303 • DALLAS, TEXAS 75265
3
Obsolete Device
TIBPAL22VP10-20C, TIBPAL22VP10-25M
HIGH-PERFORMANCE IMPACT-Xꢀ™ PROGRAMMABLE ARRAY LOGIC CIRCUITS
SRPS013A − D2943, FEBRUARY 1987 − REVISED DECEMBER 2010
POST OFFICE BOX 655303 • DALLAS, TEXAS 75265
4
Obsolete Device
TIBPAL22VP10-20C, TIBPAL22VP10-25M
HIGH-PERFORMANCE IMPACT-Xꢀ™ PROGRAMMABLE ARRAY LOGIC CIRCUITS
SRPS013A − D2943, FEBRUARY 1987 − REVISED DECEMBER 2010
POST OFFICE BOX 655303 • DALLAS, TEXAS 75265
5
Obsolete Device
TIBPAL22VP10-20C, TIBPAL22VP10-25M
HIGH-PERFORMANCE IMPACT-Xꢀ™ PROGRAMMABLE ARRAY LOGIC CIRCUITS
SRPS013A − D2943, FEBRUARY 1987 − REVISED DECEMBER 2010
output logic macrocell diagram
Output Logic Macrocell
MUX
2
3
I = 0
AR
SS
R
1D
0
1
1
0
C1
0
3
1S
G
From Clock Buffer
S0
MUX
1/2/3
0
3
1
0
G
†
S1
S2
AR = asynchronous reset
SS = synchronous set
†
This fuse is unique to the Texas Instruments TIBPAL22VP10’. It allows feedback from the I/O port using registered outputs as shown in the
macrocell fusing logic function table.
POST OFFICE BOX 655303 • DALLAS, TEXAS 75265
6
Obsolete Device
TIBPAL22VP10-20C, TIBPAL22VP10-25M
HIGH-PERFORMANCE IMPACT-Xꢀ™ PROGRAMMABLE ARRAY LOGIC CIRCUITS
SRPS013A − D2943, FEBRUARY 1987 − REVISED DECEMBER 2010
R
R
1D
1D
C1
1S
C1
1S
S2 = 0
S1 = 0
S0 = 0
S2 = 0
S1 = 0
S0 = 1
REGISTER FEEDBACK, REGISTERED, ACTIVE-LOW OUTPUT
REGISTER FEEDBACK, REGISTERED, ACTIVE-HIGH OUTPUT
R
R
1D
C1
1D
C1
S2 = 1
S1 = 0
S0 = 0
S2 = 1
S1 = 0
S0 = 1
1S
1S
†
†
I/O FEEDBACK, REGISTERED, ACTIVE-LOW OUTPUT
I/O FEEDBACK, REGISTERED, ACTIVE-HIGH OUTPUT
S2 = X
S1 = 1
S0 = 0
S2 = X
S1 = 1
S0 = 1
I/O FEEDBACK, COMBINATIONAL, ACTIVE-LOW OUTPUT
I/O FEEDBACK, COMBINATIONAL, ACTIVE-HIGH OUTPUT
†
These configurations are unique to the TIBPAL22VP10’ and provide added flexibility when comparing it to the TIBPAL22V10 or TIBPAL22V10A.
Figure 1. Resultant Macrocell Feedback and Output Logic After Programming
POST OFFICE BOX 655303 • DALLAS, TEXAS 75265
7
Obsolete Device
TIBPAL22VP10-20C, TIBPAL22VP10-25M
HIGH-PERFORMANCE IMPACT-Xꢀ™ PROGRAMMABLE ARRAY LOGIC CIRCUITS
SRPS013A − D2943, FEBRUARY 1987 − REVISED DECEMBER 2010
MACROCELL FEEDBACK AND OUTPUT FUNCTION TABLE
FUSE SELECT
FEEDBACK AND OUTPUT CONFIGURATION
S2
0
S1
S0
0
0
Register feedback
Register feedback
I/O feedback
Registered
Registered
Registered
Registered
Active low
Active high
Active low
Active high
0
0
1
1
0
0
1
0
1
I/O feedback
X
X
1
0
I/O feedback
Combinational Active low
Combinational Active high
1
1
I/O feedback
0 = unblown fuse, 1 = blown fuse, X = unblown or blown fuse
S2, S1 and S0 are select-function fuses as shown in the output logic macrocell diagram.
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)
Supply voltage, V (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 V
CC
Input voltage (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.5 V
Voltage applied to disabled output (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.5 V
Operating free-air temperature range: TIBPAL22VP10-20C . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0°C to 75°C
TIBPAL22VP10-25M . . . . . . . . . . . . . . . . . . . . . . . . . . −55°C to 125°C
Storage temperature range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −65°C to 150°C
NOTE 1: These ratings apply except for programming pins during a programming cycle or during a preload cycle.
recommended operating conditions
TIBPAL22VP10-20C
TIBPAL22VP10-25M
UNIT
MIN NOM
MAX
5.25
5.5
MIN NOM
MAX
5.5
5.5
0.8
−2
V
V
V
Supply voltage
4.75
2
5
4.5
2
5
V
V
CC
IH
IL
High-level input voltage
Low-level input voltage
High-level output current
Low-level output current
0.8
V
I
I
f
−3.2
16
mA
mA
MHz
OH
12
OL
†
Clock frequency
37
25
clock
Clock high or low
10
20
15
15
15
20
0
20
30
20
20
20
25
0
t
Pulse duration
ns
w
Asynchronous Reset high or low
Input
Feedback
t
Setup time before clock↑
ns
su
Synchronous Preset (active)
Asynchronous Reset (inactive)
t
Hold time, input, preset, or feedback after clock↑
ns
h
T
A
Operating free-air temperature
0
75
−55
125
°C
1
†
f
f
(with feedback)
+
, f
clock
without feedback can be calculated as
clock
clock
t
) t
(CLK to Q)
su
pd
1
.
(without feedback)
+
t
high ) t low
w
w
POST OFFICE BOX 655303 • DALLAS, TEXAS 75265
8
Obsolete Device
TIBPAL22VP10-20C
HIGH-PERFORMANCE IMPACT-Xꢀ™ PROGRAMMABLE ARRAY LOGIC CIRCUITS
SRPS013 − D2943, FEBRUARY 1987 − REVISED JUNE 1991
electrical characteristics over recommended operating free-air temperature range
†
PARAMETER
TEST CONDITIONS
I = −18 mA
MIN TYP
MAX
UNIT
V
V
V
V
V
CC
V
CC
V
CC
V
CC
= 4.75 V,
= 4.75 V,
= 4.75 V,
= 5.25 V,
−1.2
IK
I
I
I
= −3.2 mA
= 16 mA
= 2.7 V
2.4
3.5
0.35
V
OH
OL
OH
OL
0.5
0.1
V
I
V
O
mA
OZH
Any output
Any I/O
−100
−250
1
I
V
= 5.25 V,
V
= 0.4 V
O
μ
A
OZL
CC
I
I
I
V
= 5.25 V,
= 5.25 V,
= 5.25 V,
V = 5.5 V
mA
μA
mA
I
CC
CC
CC
I
V
V
V = 2.7 V
25
IH
IL
I
V = 0.4 V
−0.25
I
‡
I
I
V
V
= 5.25 V,
= 5.25 V,
V = 0.5 V
O
−30
−90
mA
mA
OS
CC
V = GND,
I
Outputs open
140
180
CC
CC
switching characteristics over recommended ranges of supply voltage and operating free-air
temperature (unless otherwise noted)
FROM
(INPUT)
TO
(OUTPUT)
†
PARAMETER
TEST CONDITION
MIN TYP
MAX
UNIT
§
f
t
37
50
12
12
8
MHz
ns
max
I, I/O
I, I/O (reset)
CLK
I/O
Q
C = 50 pF,
20
20
12
20
20
pd
L
t
pd
t
pd
t
en
t
dis
R1 = 300 Ω,
R2 = 390 Ω,
See Figure 4
ns
Q
ns
I, I/O
I/O, Q
I/O, Q
12
12
ns
I, I/O
ns
†
‡
All typical values are at V = 5 V, T = 25°C.
Not more than one output should be shorted at a time, and the duration of the short circuit should not exceed one second. V is set at 0.5 V to
CC
A
O
avoid test problems caused by test equipment ground degradation.
1
§
f
f
(with feedback)
+
, f
max
without feedback can be calculated as
max
max
t
) t
(CLK to Q)
su
pd
1
.
(without feedback)
+
t
high ) t low
w
w
POST OFFICE BOX 655303 • DALLAS, TEXAS 75265
9
Obsolete Device
TIBPAL22VP10-25M
HIGH-PERFORMANCE IMPACT-Xꢀ™ PROGRAMMABLE ARRAY LOGIC CIRCUITS
SRPS013 − D2943, FEBRUARY 1987 − REVISED JUNE 1991
electrical characteristics over recommended operating free-air temperature range
†
PARAMETER
TEST CONDITIONS
I = −18 mA
MIN TYP
MAX
UNIT
V
V
V
V
V
CC
V
CC
V
CC
V
CC
V
CC
V
CC
V
CC
V
CC
= 4.5 V,
= 4.5 V,
= 4.5 V,
= 5.5 V,
= 5.5 V,
= 5.5 V,
= 5.5 V,
= 5.5 V,
−1.2
IK
OH
OL
OZH
OZL
I
I
I
I
= −2 mA
= 12 mA
= 2.7 V
2.4
3.5
0.25
V
OH
OL
0.5
0.1
V
I
I
I
I
I
V
V
mA
mA
mA
μA
mA
O
O
= 0.4 V
−0.1
1
V = 5.5 V
I
V = 2.7 V
I
25
IH
V = 0.4 V
I
−0.25
IL
‡
I
I
V
V
= 5.5 V,
= 5.5 V,
V = 0.5 V
O
−30
−90
mA
mA
OS
CC
V = GND,
I
Outputs open
140
200
CC
CC
switching characteristics over recommended ranges of supply voltage and operating free-air
temperature (unless otherwise noted)
FROM
(INPUT)
TO
(OUTPUT)
†
PARAMETER
TEST CONDITION
MIN TYP
MAX
UNIT
§
f
t
25
50
12
12
8
MHz
ns
max
I, I/O
I, I/O (reset)
CLK
I/O
Q
C = 50 pF,
25
25
15
25
25
pd
L
t
pd
t
pd
t
en
t
dis
R1 = 390 Ω,
R2 = 750 Ω,
See Figure 4
ns
Q
ns
I, I/O
I/O, Q
I/O, Q
12
12
ns
I, I/O
ns
†
‡
All typical values are at V = 5 V, T = 25°C.
Not more than one output should be shorted at a time, and the duration of the short circuit should not exceed one second. V is set at 0.5 V to
CC
A
O
avoid test problems caused by test equipment ground degradation.
1
§
f
f
(with feedback)
+
, f
max
without feedback can be calculated as
max
max
t
) t
(CLK to Q)
su
pd
1
.
(without feedback)
+
t
high ) t low
w
w
POST OFFICE BOX 655303 • DALLAS, TEXAS 75265
10
Obsolete Device
TIBPAL22VP10-20C, TIBPAL22VP10-25M
HIGH-PERFORMANCE IMPACT-Xꢀ™ PROGRAMMABLE ARRAY LOGIC CIRCUITS
SRPS013 − D2943, FEBRUARY 1987 − REVISED JUNE 1991
preload procedure for registered outputs (see Notes 2 and 3)
The output registers can be preloaded to any desired state during device testing. This permits any state to be
tested without having to step through the entire state-machine sequence. Each register is preloaded individually
by following the steps given below:
Step 1. With V at 5 V and pin 1 at V , raise pin 13 to V .
IHH
CC
IL
Step 2. Apply either V or V to the output corresponding to the register to be preloaded.
IL
IH
Step 3. Pulse pin 1, clocking in preload data.
Step 4. Remove output voltage, then lower pin 13 to V . Preload can be verified by observing the voltage level
IL
at the output pin.
V
IHH
V
IL
Pin 13
t
t
d
su
t
t
w
d
V
V
V
V
IH
Pin 1
IL
V
V
IH
OH
OL
Registered I/O
Input
Output
IL
Figure 2. Preload Waveforms
NOTES: 2. Pin numbers shown are for JT and NT packages only. If chip-carrier socket adapter is not used, pin numbers must be changed
accordingly.
3. td = tsu = tw = 100 ns to 1000 ns. VIHH = 10.25 V to 10.75 V.
POST OFFICE BOX 655303 • DALLAS, TEXAS 75265
11
Obsolete Device
TIBPAL22VP10-20C, TIBPAL22VP10-25M
HIGH-PERFORMANCE IMPACT-Xꢀ™ PROGRAMMABLE ARRAY LOGIC CIRCUITS
SRPS013 − D2943, FEBRUARY 1987 − REVISED JUNE 1991
power-up reset
Following power up, all registers are reset to zero. The output level depends on the polarity selected during
programming. This feature provides extra flexibility to the system designer and is especially valuable in
simplifying state-machine initialization. To ensure a valid power-up reset, it is important that the rise of V
be
CC
monotonic. Following power-up reset, a low-to-high clock transition must not occur until all applicable input and
feedback setup times are met.
V
CC
5 V
4 V
†
t
pd
(600 ns typ, 1000 ns MAX)
V
OH
Active High
State Unknown
1.5 V
1.5 V
Registered Output
V
V
OL
OH
Active Low
Registered Output
State Unknown
V
OL
‡
t
su
V
V
IH
CLK
1.5 V
1.5 V
IL
t
w
†
‡
This is the power-up reset time and applies to registered outputs only. The values shown are from characterization data.
This is the setup time for input or feedback.
Figure 3. Power-Up Reset Waveforms
programming information
Texas Instruments programmable logic devices can be programmed using widely available software and
inexpensive device programmers.
When the additional fuses are not being used, the TIBPAL22VP10 can be programmed using the
TIBPAL22V10/10A programming algorithm. The fuse configuration data can either be from a JEDEC file (format
per JEDEC Standard No. 3-A) or a TIBPAL22V10/10A master.
Complete programming specifications, algorithms, and the latest information on hardware, software, and
firmware are available upon request. Information on programmers capable of programming Texas Instruments
programmable logic is also available, upon request, from the nearest TI field sales office, local authorized TI
distributor, or by calling Texas Instruments at (214) 997-5666.
POST OFFICE BOX 655303 • DALLAS, TEXAS 75265
12
Obsolete Device
TIBPAL22VP10-20C, TIBPAL22VP10-25M
HIGH-PERFORMANCE IMPACT-Xꢀ™ PROGRAMMABLE ARRAY LOGIC CIRCUITS
SRPS013 − D2943, FEBRUARY 1987 − REVISED JUNE 1991
PARAMETER MEASUREMENT INFORMATION
5 V
S1
R1
From Output
Under Test
Test
Point
C
R2
L
(see Note A)
LOAD CIRCUIT FOR
3-STATE OUTPUTS
(3.5 V) [3 V]
(0.3 V) [0]
High-Level
Pulse
(3.5 V) [3 V]
(0.3 V) [0]
1.5 V 1.5 V
Timing
Input
1.5 V
t
w
t
h
t
su
(3.5 V) [3 V]
(0.3 V) [0]
(3.5 V) [3 V]
(0.3 V) [0]
Data
Input
Low-Level
Pulse
1.5 V
1.5 V 1.5 V
1.5 V
VOLTAGE WAVEFORMS
SETUP AND HOLD TIMES
VOLTAGE WAVEFORMS
PULSE DURATIONS
(3.5 V) [3 V]
(0.3 V) [0]
Output
Control
(3.5 V) [3 V]
(0.3 V) [0]
1.5 V
1.5 V
(low−level
1.5 V
1.5 V
Input
enabling)
t
en
t
pd
t
t
t
dis
pd
pd
V
OH
In-Phase
Output
≈ 3.3 V
1.5 V
1.5 V
1.5 V
Waveform 1
S1 Closed
(see Note B)
1.5 V
V
+0.5 V
OL
V
OL
V
OL
t
pd
t
dis
V
OH
t
en
Out-of-Phase
Output
(see Note D)
1.5 V
V
OH
Waveform 2
S1 Open
(see Note B)
V
OL
1.5 V
V
−0.5 V
≈ 0 V
OH
VOLTAGE WAVEFORMS
PROPAGATION DELAY TIMES
VOLTAGE WAVEFORMS
ENABLE AND DISABLE TIMES, 3-STATE OUTPUTS
NOTES: A. C includes probe and jig capacitance and is 50 pF for t and t , 5 pF for t
.
dis
L
pd
en
B. Waveform 1 is for an output with internal conditions such that the output is low except when disabled by the output control. Waveform 2
is for an output with internal conditions such that the output is high except when disabled by the output control.
C. All input pulses have the following characteristics: For C suffix, use the voltage levels indicated in parentheses ( ). PRR ≤ 1 MHz,
t = t ≤ 2 ns, duty cycle = 50%. For M suffix, use the voltage levels indicated in brackets [ ]. PRR ≤ 10 MHz, t and t ≤ 2 ns,
r
f
r
f
duty cycle = 50%.
D. When measuring propagation delay times of 3-state outputs, switch S1 is closed.
E. Equivalent loads may be used for testing.
Figure 4. Load Circuit and Voltage Waveforms
POST OFFICE BOX 655303 • DALLAS, TEXAS 75265
13
Obsolete Device
Obsolete Device
UTAH: Salt Lake City: 2180 South 1300 East, Sute 335,
MALAYSIA: Texas Instruments Malaysia, Sdn. Bhd., Asia
Pacific, Lot 36.1 #Box 93, Menara Maybank, 100 Jalan Tun
Perak, 50050 Kuala Llumpur, Malaysia, 2306001.
MEXICO: Texas Instruments de Mexico S.A., de C.V.,
Alfonso Reyes 115, Col. Hipodromo Condesa, Mexico, D.F.,
Mexico 06170, 5-515-6081.
NORWAY: Texas Instruments Norge A/S, P.B. 106, Refstad
(Sinsenveien 53), 0513 Oslo 5, Norway, (02) 155 090.
PEOPLE’S REPUBLIC OF CHINA: Texas Instruments
China Inc., Beijing Representative Office, 7-05 CITIC
Building, 19 Jianguomenwai Dajie, Beijing, China,
500-2255, Ext. 3750.
Salt Lake City, UT 54106, (801) 466-8972.
TI Worldwide
Sales Offices
WISCONSIN: Waukesha: 20825 Swenson Drive,
Suite 900, Waukesha WI 53186, (414) 798-1001.
CANADA: Nepean: 301 Moodie Drive, Suite 102, Mallom
Center, Nepean, Ontario, Canada K2H 9C4,
(613) 726-1970;
Richmond Hill: 280 Centre Street East, Richmond Hill,
Ontario, Canada L4C 1B1, (416) 884-9181;
St. Laurent: 9460 Trans Canada Highway, St. Laurent,
Quebec, Canada H4S 1R7, (514) 335-8392.
ALABAMA: Huntsville: 4960 Corporate Drive,
Suite 150, Huntsville, AL 35805, (205) 837-7530.
ARIZONA: Phoenix: 8825 N. 23rd Avenue, Suite 100,
Phoenix, AZ 85021, (602) 995-1007.
PHILIPPINES: Texas Instruments Asia Ltd.,
Philippines Branch, 14th Floor, Ba-Lepanto Building,
Paseo de Roxas, Makati, Metro Manila, Philippines,
2-8176031.
PORTUGAL: Texas Instruments Equipamento Electronico
(Portugal) Ltda., Ing. Frederico Ulricho, 2650 Moreira Da
Maia, 4470 Maia, Portugal (2) 948 1003.
CALIFORNIA: Irvine: 1920 Main Street, Suite 900,
AUSTRALIA (& NEW ZEALAND): Texas Instruments
Australia Ltd., 6-10 Talavera Road, North Ryde (Sydney),
New South Wales, Australia 2113, 2-878-9000; 14th Floor,
380 Street, Kilda Road, Melbourne, Victoria, Australia 3004,
3-696-1211; 171 Philip Highway, Elizabeth, South Australia
5112, 8 255-2066.
BELGIUM: Texas Instruments Belgium S.A./N.V.,
Avenue Jules Bordetlaan 11, 1140 Brussels, Belgium,
(02) 242 30 80.
BRAZIL: Texas Instruments Electronicos do Brasil Ltda.,
Av. Eng. Luiz Carlos Berrini 1461-11o andar, 04571,
Sao Paulo, SP, Brazil, 11-535−5133.
DENMARK: Texas Instruments A/S, Borupvang 2D,
2750 Ballerup, Denmark, (44) 68 74 00.
Irvine, CA 92714, (714) 660-1200;
San Diego: 5625 Ruffin Road, Suite 100,
San Diego, CA 92123, (619) 278-9600;
Santa Clara: 5353 Betsy Ross Drive,
Santa Clara, CA 95054, (408) 980-9000;
Woodland Hills: 21550 Oxnard Street, Suite 700,
Woodland Hills, CA 91367, (818) 704-8100.
SINGAPORE (& INDIA, INDONESIA, MALAYSIA,
THAILAND): Texas Instruments Singapore (PTE) Ltd.,
Asia Pacific, 101 Thomson Road, #23-01,
COLORADO: Aurora: 1400 S. Potomac Street, Suite 101,
Aurora, CO 80012, (303) 368-8000.
CONNECTICUT: Wallingford: 9 Barnes Industrial Park
So., Wallingford, CT 06492, (203) 269-0074.
United Square, Singapore 1130, 3508100.
SPAIN: Texas Instruments Espana S.A., c/Gobelas 43,
Urbanizasion, La Florida, 28023, Madrid, Spain, (1) 372
8051; c/Diputacion, 279-3-5, 08007 Barcelona, Spain, (3)
317 91 80.
SWEDEN: Texas Instruments International Trade
Corporation (Sverigefilialen), Isafjordsgaton, Box 30, S-164
93 Kista, Sweden, (08) 752 58 00.
SWITZERLAND: Texas Instruments Switzerland AG,
Riedstrasse 6, C8953 Dietikon, Switzerland,
(01) 744 2811.
TAIWAN: Texas Instruments Taiwan Limited, Taipei
Branch, 10th Floor Bank Tower, 205 Tung Hwa N. Road,
Taipei, Taiwan, 10592 Republic of China, 2-7139311.
FLORIDA: Altamonte Springs: 370 S. North Lake
Boulevard, Suite 1008, Altamonte Springs, FL 32701,
(407) 260-2116;
FINLAND: Texas Instruments OY, Ahertajantle 3,
P.O. Box 86, 02321 Espoo, Finland, (0) 802 6517.
FRANCE: Texas Instruments France, 8-10 Avenue
Morane-Saulnier, B.P. 67, 78141 Velizy Villacoublay Cedex,
France, (1) 30 70 1003.
Fort Lauderdale: 2950 N.W. 62nd Street,
Suite 100, Fort Lauderdale, FL 33309,
(305) 973-8502; Tampa: 4803 George Road, Suite 390,
Tampa, FL 33634-6234, (813) 885-7588.
GEORGIA: Norcross: 5515 Spalding Drive,
Norcross, GA 30092-2560, (404) 662-7967.
ILLINOIS: Arlington Heights: 515 West Algonquin,
Arlington Heights, IL 60005, (708) 640-6925.
GERMANY: Texas Instruments Deutschland GmbH.,
Haggertystrasse 1, 8050 Freising, (08161) 80-0;
Kurfurstendamm 195-196, 1000 Berlin 15, (030) 8 82 73 65;
Dusseldorfer Strasse 40, 6236 Eschborn 1, (06196) 80 70;
Kirchhorster Strasse 2, 3000 Hannover 51, (0511) 64 68-0;
Maybachstrasse II, 7302 Ostfildern 2 (Nellingen),
(0711) 3403257; Gildehofcenter, Hollestrasses 3, 4300
Essen 1, (0201) 24 25-0.
HOLLAND: Texas Instruments Holland B.V., Hogehilweg
19, Postbus 12995, 1100 AZ Amsterdam-Zuidoost, Holland,
(020) 5602911.
HONG KONG: Texas Instruments Hong Kong Ltd., 8th
Floor, World Shipping Center, 7 Canton Road, Kowloon,
Hong Kong, 737-0338.
HUNGARY: Texas Instruments Representation, Budaorsi
ut.42, 1112 Budapest, Hungary, (1) 1 66 66 17.
IRELAND: Texas Instruments Ireland Ltd., 7/8 Harcourt
Street, Dublin 2, Ireland, (01) 755233.
ITALY: Texas Instruments Italia S.p.A., Centro Direzionale
Colleoni, Palazzo Perseo-Via Paracelso 12, 20041 Agrate
Brianza (Mi), Italy, (039) 63221; Via Castello della Magliana,
38, 00148 Roma, Italy (06) 6572651; Via Amendola, 17,
40100 Bologna, Italy (051) 554004.
INDIANA: Carmel: 550 Congressional Drive, Suite 100,
TURKEY: Texas Instruments, DSEG MidEast Regional
Marketing Office, Karum Center, Suite 442, Iran Caddesi
21, 06680 Kavaklldere, Ankara, Turkey, 4-468-0155.
UNITED KINGDOM: Texas Instruments Ltd., Manton Lane,
Bedford, England, MK41 7PA, (0234) 270 111.
Carmel, IN 46032, (317) 573-6400;
Fort Wayne: 103 Airport North Office Park,
Fort Wayne, IN 46825, (219) 489-4697.
KANSAS: Overland Park: 7300 College Boulevard,
Lighton Plaza, Suite 150, Overland Park, KS 66210,
(913) 451-4511.
MARYLAND: Columbia: 8815 Centre Park Drive,
Suite 100, Columbia, MD 21045, (410) 964-2003.
MASSACHUSETTS: Waltham: Bay Colony Corporate
Center 950 Winter Street, Suite 2800, Waltham, MA 02154,
(617) 895-9100.
MICHIGAN: Farmington Hills: 33737 W. 12 Mile Road,
Farmington Hills, MI 48018, (313) 553-1581.
MINNESOTA: Eden Prairie: 11000 W. 78th Street,
Suite 100, Eden Prairie, MN 55344, (612) 828-9300.
MISSOURI: St. Louis: 12412 Powerscourt Drive,
Suite 125, St. Louis, MO 63131, (314) 821-8400.
NEW JERSEY: Iselin: Metropolitan Corporate Plaza, 485
Bldg E. U.S. 1 South, Iselin, NJ 08830, (908) 750-1050.
NEW MEXICO: Albuquerque: 2709 J. Pan American
Freeway, N.E., Albuquerque, NM 87101, (505) 345-2555.
TI Authorized
North American
Distributors
Alliance Electronics, Inc. (military product only)
Almac/Arrow
JAPAN: Texas Instruments Japan Ltd., Aoyama Fuji
Building 3-6-12 Kita-Aoyama Minato-ku, Tokyo, Japan 107,
03-498-2111; MS Shibaura Building 9F, 4-13-23 Shibaura,
Minato-ku, Tokyo, Japan 108, 03-769-8700; Nissho-iwai
Building 5F, 2-5-8 Imabashi, Chuou-ku, Osaka, Japan 541,
06-204-1881; Dai-ni Toyota Building Nishi-kan 7F, 4-10-27
Meieki, Nakamura-ku, Nagoya, Japan 450, 052-583-8691;
Kanazawa Oyama-cho Daiichi Seimei Building 6F, 3-10
Oyama-cho, Kanazawa, Ishikawa, Japan 920,
Anthem Electronics
Arrow/Schweber
NEW YORK: East Syracuse: 6365 Collamer Drive,
East Syracuse, NY 13057, (315) 463-9291;
Fishkill: 300 Westage Business Center, Suite 140,
Fishkill, NY 12524, (914) 897-2900;
Future Electronics (Canada)
GRS Electronics Co., Inc. *
Hall-Mark Electronics
Melville: 48 South Service Road, Suite 100, Melville, NY
11747, (516) 454-6601;
Marshall Industries
Newark Electronics *
0762-23-5471; Matsumoto Showa Building 6F, 1-2-11
Fukashi, Matsumoto, Nagano, Japan 390, 0263-33-1060;
Daiichi Olympic Tachikawa Building 6F, 1-25-12,
Pittsford: 2851 Clover Street, Pittsford, NY 14534,
Wyle Laboratories
(716) 385-6770.
Zeus Components
NORTH CAROLINA: Charlotte: 8 Woodlawn Green,
Suite 100, Charlotte, NC 28217, (704) 527-0930;
Raleigh: 2809 Highwoods Boulevard, Suite 100,
Raleigh, NC 27625, (919) 876-2725.
OHIO: Beachwood: 23775 Commerce Park Road,
Beachwood, OH 44122-5875, (216) 765-7258;
Beavercreek: 4200 Colonel Glenn Highway, Suite 600,
Beavercreek, OH 45431, (513) 427-6200.
Akebono-cho, Tachikawa, Tokyo, Japan 190,
Rochester Electronics, Inc. (obsolete product only)
0425-27-6760; Yokohama Business Park East Tower 10F,
134 Goudo-cho Hodogaya-ku, Yokohama-shi, Kanagawa,
Japan 240, 045-338-1220; Nihon Seimei Kyoto Yasaka
Building 5F, 843-2, Higashi Shiokohji-cho, Higashi-iru,
Nishinotoh-in, Shiokohji-dori, Shimogyo-ku, Kyoto, Japan
600, 075-341-7713; Sumitomo Seimei Kumagaya Building
8F, 2-44 Yayoi, Kumagaya, Saitama, Japan 360,
*Not authorized for TI military products
0485-22-2440; 2597-1, Aza Harudai, Oaza Yasaka, Kitsuki,
Oita, Japan 873, 09786-3-3211.
OREGON: Beaverton: 6700 S.W. 105th Street,
Suite 110, Beaverton, OR 97005, (503) 643-6758.
KOREA: Texas Instruments Korea Ltd., 28th Floor, Trade
Tower, 159, Samsung-Dong, Kangnam-ku Seoul, Korea, 2
551-2800.
PENNSYLVANIA: Blue Bell: 670 Sentry Parkway,
Suite 200, Blue Bell, PA 19422, (215) 825-9500.
PUERTO RICO: Hato Rey: 615 Mercantile Plaza Building,
Suite 505, Hato Rey, PR 00919, (809) 753-8700.
TEXAS: Austin: 12501 Research Boulevard,
Austin, TX 78759, (512) 250-6769;
Dallas: 7839 Churchill Way, Dallas, TX 75251,
(214) 917-1264;
Houston: 9301 Southwest Freeway, Commerce Park, Suite
360, Houston, TX 77074, (713) 778-6592;
Midland: FM 1788 & I-20, Midland, TX 79711-0448,
(915) 561-7137.
B0892
©1992 Texas Instruments Incorporated
Obsolete Device
MICHIGAN: Detroit: Arrow/Schweber (313) 462-2290;
Hall-Mark (313) 416-5800; Marshall (313) 525-5850;
Newark (313) 967-0600.
MINNESOTA: Anthem (612) 944-5454; Arrow/Schweber
(612) 941-5280; Hall-Mark (612) 881-2600; Marshall (612)
559-2211.
MISSOURI: Arrow/Schweber (314) 567-6888; Hall-Mark
(314) 291-5350; Marshall (314) 291-4650.
NEW JERSEY: Anthem (201) 227-7960; Arrow/Schweber
(201) 227-7880, (609) 596-8000; Hall-Mark (201) 515-3000,
(609) 235-1900; Marshall (201) 882-0320, (609) 234-9100.
TI Authorized
TI North
American Sales North American
Offices
Distributors
NEW MEXICO: Alliance (505) 292-3360.
Alliance Electronics, Inc. (military product only)
Almac/Arrow
ALABAMA: Huntsville: (205) 837-7530
ARIZONA: Phoenix: (602) 995-1007
NEW YORK: Long Island: Anthem (516) 864-6600;
Arrow/Schweber (516) 231-1000; Hall-Mark (516)
737-0600; Marshall (516) 273-2424; Zeus (914) 937-7400.
Rochester: Arrow/Schweber (716) 427-0300; Hall-Mark
(716) 425-3300; Marshall (716) 235-7620.
Syracuse: Marshall (607) 785-2345.
NORTH CAROLINA: Arrow/Schweber (919) 876-3132;
Hall-Mark (919) 872-0712; Marshall (919) 878-9882.
Anthem Electronics
Arrow/Schweber
CALIFORNIA: Irvine: (714) 660-1200
Future Electronics (Canada)
GRS Electronics Co., Inc.
Hall-Mark Electronics
San Diego: (619) 278-9600
Santa Clara: (408) 980-9000
Woodland Hills: (818) 704-8100
Marshall Industries
Newark Electronics
COLORADO: Aurora: (303) 368-8000
CONNECTICUT: Wallingford: (203) 269-0074
FLORIDA: Altamonte Springs: (407) 260-2116
Fort Lauderdale: (305) 973-8502
Tampa: (813) 885-7588
Rochester Electronics, Inc.
(obsolete product only (508) 462-9332)
Wyle Laboratories
OHIO: Cleveland: Arrow/Schweber (216) 248-3990;
Hall-Mark (216) 349-4632; Marshall (216) 248-1788.
Columbus: Hall-Mark (614) 888-3313.
Zeus Components
GEORGIA: Norcross: (404) 662-7967
ILLINOIS: Arlington Heights: (708) 640-3000
INDIANA: Carmel: (317) 573-6400
Fort Wayne: (219) 489-4697
KANSAS: Overland Park: (913) 451-4511
MARYLAND: Columbia: (410) 964-2003
MASSACHUSETTS: Waltham: (617) 895-9100
MICHIGAN: Farmington Hills: (313) 553-1581
MINNESOTA: Eden Prairie: (612) 828-9300
MISSOURI: St. Louis: (314) 821-8400
Dayton: Arrow/Schweber (513) 435-5563; Marshall (513)
898-4480; Zeus (513) 293-6162.
OKLAHOMA: Arrow/Schweber (918) 252-7537; Hall-Mark
(918) 254-6110.
OREGON: Almac/Arrow (503) 629-8090; Anthem (503)
643-1114; Marshall (503) 644-5050; Wyle (503) 643-7900.
TI Distributors
ALABAMA: Arrow/Schweber (205) 837-6955; Hall-Mark
PENNSYLVANIA: Anthem (215) 443-5150;
Arrow/Schweber (215) 928-1800; GRS (215) 922-7037;
(609) 964-8560; Marshall (412) 788-0441.
TEXAS: Austin: Arrow/Schweber (512) 835-4180;
Hall-Mark (512) 258-8848; Marshall (512) 837-1991; Wyle
(512) 345-8853;
Dallas: Anthem (214) 238-7100; Arrow/Schweber (214)
380-6464; Hall-Mark (214) 553-4300; Marshall (214)
233-5200; Wyle (214) 235-9953; Zeus (214) 783-7010;
Houston: Arrow/Schweber (713) 530-4700; Hall-Mark
(713) 781-6100; Marshall (713) 467-1666; Wyle (713)
879-9953.
UTAH: Anthem (801) 973-8555; Arrow/Schweber (801)
973-6913; Marshall (801) 973-2288; Wyle (801) 974-9953.
WASHINGTON: Almac/Arrow (206) 643-9992, Anthem
(206) 483-1700; Marshall (206) 486-5747; Wyle (206)
881-1150.
WISCONSIN: Arrow/Schweber (414) 792-0150; Hall-Mark
(414) 797-7844; Marshall (414) 797-8400.
CANADA: Calgary: Future (403) 235-5325;
Edmonton: Future (403) 438-2858;
Montreal: Arrow/Schweber (514) 421-7411; Future (514)
694-7710; Marshall (514) 694-8142
Ottawa: Arrow/Schweber (613) 226-6903; Future (613)
820-8313.
(205) 837-8700; Marshall (205) 881-9235.
ARIZONA: Anthem (602) 966-6600; Arrow/Schweber (602)
437-0750; Hall-Mark (602) 431-0030; Marshall (602)
496-0290; Wyle (602) 437-2088.
CALIFORNIA: Los Angeles/Orange County: Anthem
(818) 775-1333, (714) 768-4444; Arrow/Schweber (818)
380-9686, (714) 838-5422; Hall-Mark (818) 773-4500, (714)
727-6000; Marshall (818) 878-7000, (714) 458-5301; Wyle
(818) 880-9000, (714) 863-9953; Zeus (714) 921-9000,
(818) 889-3838;
NEW JERSEY: Iselin: (908) 750-1050
NEW MEXICO: Albuquerque: (505) 345-2555
NEW YORK: East Syracuse: (315) 463-9291
Fishkill: (914) 897-2900
Melville: (516) 454-6600
Pittsford: (716) 385-6770
Sacramento: Anthem (916) 624-9744; Hall-Mark (916)
624-9781; Marshall (916) 635-9700; Wyle (916) 638-5282;
NORTH CAROLINA: Charlotte: (704) 527-0930
Raleigh: (919) 876-2725
San Diego: Anthem (619) 453-9005; Arrow/Schweber
(619) 565-4800; Hall-Mark (619) 268-1201; Marshall (619)
578-9600; Wyle (619) 565-9171; Zeus (619) 277-9681.
San Francisco Bay Area: Anthem (408) 453-1200;
Arrow/Schweber (408) 441-9700, (510) 490-9477;
Hall-Mark (408) 432-4000; Marshall (408) 942-4600;
Wyle (408) 727-2500; Zeus (408) 629-4789.
COLORADO: Anthem (303) 790-4500; Arrow/Schweber
(303) 799-0258; Hall-Mark (303) 790-1662; Marshall (303)
451-8383; Wyle (303) 457-9953.
CONNECTICUT: Anthem (203) 575-1575; Arrow/Schweber
(203) 265-7741; Hall-Mark (203) 271-2844; Marshall (203)
265-3822.
OHIO: Beachwood: (216) 765-7258
Beavercreek: (513) 427-6200
OREGON: Beaverton: (503) 643-6758
PENNSYLVANIA: Blue Bell: (215) 825-9500
PUERTO RICO: Hato Rey: (809) 753-8700
TEXAS: Austin: (512) 250-6769
Dallas: (214) 917-1264
Houston: (713) 778-6592
Midland: (915) 561-7137
UTAH: Salt Lake CIty: (801) 466-8972
WISCONSIN: Waukesha: (414) 798-1001
FLORIDA: Fort Lauderdale: Arrow/Schweber (305)
429-8200; Halll-Mark (305) 971-9280; Marshall (305)
977-4880.
Orlando: Arrow/Schweber (407) 333-9300; Hall-Mark (407)
830-5855; Marshall (407) 767-8585; Zeus (407) 788-9100.
Tampa: Hall-Mark (813) 541-7440; Marshall (813)
573-1399.
CANADA: Nepean: (613) 726-1970
Richmond Hill: (416) 884-9181
St. Laurent: (514) 335-8392
Quebec: Future (418) 897-6666.
Toronto: Arrow/Schweber (416) 670-7769;
Future (416) 612-9200; Marshall (416) 458-8046.
Vancouver: Arrow/Schweber (604) 421-2333;
Future (604) 294-1166.
GEORGIA: Arrow/Schweber (404) 497-1300; Hall-Mark
(404) 623-4400; Marshall (404) 923-5750.
TI Regional
Technology
Centers
ILLINOIS: Anthem (708) 884-0200; Arrow/Schweber (708)
250-0500; Hall-Mark (312) 860-3800; Marshall (708)
490-0155; Newark (312)784-5100.
INDIANA: Arrow/Schweber (317) 299-2071; Hall-Mark
(317) 872-8875; Marshall (317) 297-0483.
IOWA: Arrow/Schweber (319) 395-7230.
KANSAS: Arrow/Schweber (913) 541-9542; Hall-Mark
(913) 888-4747; Marshall (913) 492-3121.
MARYLAND: Anthem (301) 995-6640; Arrow/Schweber
(301) 596-7800; Hall-Mark (301) 988-9800; Marshall (301)
622-1118; Zeus (301) 997-1118.
MASSACHUSETTS: Anthem (508) 657-5170;
Arrow/Schweber (508) 658-0900; Hall-Mark (508)
667-0902; Marshall (508) 658-0810; Wyle (617) 272-7300;
Zeus (617) 246-8200.
TI Die Processors
Chip Supply
Elmo Semiconductor
Minco Technology Labs
(407) 298-7100
(818) 768-7400
(512) 834-2022
CALIFORNIA: Irvine: (714) 660-8140
Santa Clara: (408) 748-2222
GEORGIA: Norcross: (404) 662-7945
ILLINOIS: Arlington Heights: (708) 640-2909
INDIANA: Indianapolis: (317) 573-6400
MASSACHUSETTS: Waltham: (617) 895-9196
MEXICO: Mexico City: 491-70834
MINNESOTA: Minneapolis: (612) 828-9300
TEXAS: Dallas: (214) 917-3881
CANADA: Nepean: (613) 726-1970
Customer
Response Center
TOLL FREE:
(800) 336-5236
OUTSIDE USA: (214) 995-6611
(8:00 a.m. − 5:00 p.m. CST)
D0892
©1992 Texas Instruments Incorporated
SRPS013
PACKAGE OPTION ADDENDUM
www.ti.com
21-Mar-2013
PACKAGING INFORMATION
Orderable Device
Status Package Type Package Pins Package Qty
Eco Plan Lead/Ball Finish
MSL Peak Temp
Op Temp (°C)
Top-Side Markings
Samples
Drawing
(1)
(2)
(3)
(4)
5962-8605303KA
OBSOLETE
OBSOLETE
OBSOLETE
OBSOLETE
OBSOLETE
OBSOLETE
CFP
PLCC
PDIP
LCCC
CDIP
CFP
W
24
28
24
28
24
24
TBD
TBD
TBD
TBD
TBD
TBD
Call TI
Call TI
Call TI
Call TI
Call TI
Call TI
Call TI
Call TI
Call TI
Call TI
Call TI
Call TI
-55 to 125
0 to 75
TIBPAL22VP10-20CFN
TIBPAL22VP10-20CNT
TIBPAL22VP10-25MFKB
TIBPAL22VP10-25MJTB
TIBPAL22VP10-25MWB
FN
NT
0 to 75
FK
-55 to 125
-55 to 125
JT
W
-55 to 125 5962-8605303KA
TIBPAL22VP10-2
5MWB
(1) The marketing status values are defined as follows:
ACTIVE: Product device recommended for new designs.
LIFEBUY: TI has announced that the device will be discontinued, and a lifetime-buy period is in effect.
NRND: Not recommended for new designs. Device is in production to support existing customers, but TI does not recommend using this part in a new design.
PREVIEW: Device has been announced but is not in production. Samples may or may not be available.
OBSOLETE: TI has discontinued the production of the device.
(2) Eco Plan - The planned eco-friendly classification: Pb-Free (RoHS), Pb-Free (RoHS Exempt), or Green (RoHS & no Sb/Br) - please check http://www.ti.com/productcontent for the latest availability
information and additional product content details.
TBD: The Pb-Free/Green conversion plan has not been defined.
Pb-Free (RoHS): TI's terms "Lead-Free" or "Pb-Free" mean semiconductor products that are compatible with the current RoHS requirements for all 6 substances, including the requirement that
lead not exceed 0.1% by weight in homogeneous materials. Where designed to be soldered at high temperatures, TI Pb-Free products are suitable for use in specified lead-free processes.
Pb-Free (RoHS Exempt): This component has a RoHS exemption for either 1) lead-based flip-chip solder bumps used between the die and package, or 2) lead-based die adhesive used between
the die and leadframe. The component is otherwise considered Pb-Free (RoHS compatible) as defined above.
Green (RoHS & no Sb/Br): TI defines "Green" to mean Pb-Free (RoHS compatible), and free of Bromine (Br) and Antimony (Sb) based flame retardants (Br or Sb do not exceed 0.1% by weight
in homogeneous material)
(3) MSL, Peak Temp. -- The Moisture Sensitivity Level rating according to the JEDEC industry standard classifications, and peak solder temperature.
(4) Only one of markings shown within the brackets will appear on the physical device.
Important Information and Disclaimer:The information provided on this page represents TI's knowledge and belief as of the date that it is provided. TI bases its knowledge and belief on information
provided by third parties, and makes no representation or warranty as to the accuracy of such information. Efforts are underway to better integrate information from third parties. TI has taken and
continues to take reasonable steps to provide representative and accurate information but may not have conducted destructive testing or chemical analysis on incoming materials and chemicals.
TI and TI suppliers consider certain information to be proprietary, and thus CAS numbers and other limited information may not be available for release.
In no event shall TI's liability arising out of such information exceed the total purchase price of the TI part(s) at issue in this document sold by TI to Customer on an annual basis.
Addendum-Page 1
PACKAGE OPTION ADDENDUM
www.ti.com
21-Mar-2013
Addendum-Page 2
MECHANICAL DATA
MCER004A – JANUARY 1995 – REVISED JANUARY 1997
JT (R-GDIP-T**)
CERAMIC DUAL-IN-LINE
24 LEADS SHOWN
PINS **
A
24
28
DIM
13
24
1.280
(32,51) (37,08)
1.460
A MAX
1.240
(31,50) (36,58)
1.440
B
A MIN
B MAX
B MIN
0.300
(7,62)
0.291
(7,39)
1
12
0.070 (1,78)
0.030 (0,76)
0.245
(6,22)
0.285
(7,24)
0.320 (8,13)
0.290 (7,37)
0.015 (0,38) MIN
0.100 (2,54) MAX
0.200 (5,08) MAX
Seating Plane
0.130 (3,30) MIN
0.023 (0,58)
0.015 (0,38)
0°–15°
0.014 (0,36)
0.008 (0,20)
0.100 (2,54)
4040110/C 08/96
NOTES: A. All linear dimensions are in inches (millimeters).
B. This drawing is subject to change without notice.
C. This package can be hermetically sealed with a ceramic lid using glass frit.
D. Index point is provided on cap for terminal identification.
E. Falls within MIL STD 1835 GDIP3-T24, GDIP4-T28, and JEDEC MO-058 AA, MO-058 AB
POST OFFICE BOX 655303 • DALLAS, TEXAS 75265
MECHANICAL DATA
MCFP007 – OCTOBER 1994
W (R-GDFP-F24)
CERAMIC DUAL FLATPACK
0.375 (9,53)
0.340 (8,64)
Base and Seating Plane
0.006 (0,15)
0.004 (0,10)
0.045 (1,14)
0.026 (0,66)
0.090 (2,29)
0.045 (1,14)
0.395 (10,03)
0.360 (9,14)
0.360 (9,14)
0.240 (6,10)
0.360 (9,14)
0.240 (6,10)
0.019 (0,48)
0.015 (0,38)
1
24
0.050 (1,27)
0.640 (16,26)
0.490 (12,45)
0.030 (0,76)
0.015 (0,38)
12
13
30° TYP
1.115 (28,32)
0.840 (21,34)
4040180-5/B 03/95
NOTES: A. All linear dimensions are in inches (millimeters).
B. This drawing is subject to change without notice.
C. This package can be hermetically sealed with a ceramic lid using glass frit.
D. Falls within MIL-STD-1835 GDFP2-F24 and JEDEC MO-070AD
E. Index point is provided on cap for terminal identification only.
POST OFFICE BOX 655303 • DALLAS, TEXAS 75265
MECHANICAL DATA
MPLC004A – OCTOBER 1994
FN (S-PQCC-J**)
PLASTIC J-LEADED CHIP CARRIER
20 PIN SHOWN
Seating Plane
0.004 (0,10)
0.180 (4,57) MAX
0.120 (3,05)
D
0.090 (2,29)
D1
0.020 (0,51) MIN
3
1
19
0.032 (0,81)
0.026 (0,66)
4
18
D2/E2
D2/E2
E
E1
8
14
0.021 (0,53)
0.013 (0,33)
0.050 (1,27)
9
13
0.007 (0,18)
M
0.008 (0,20) NOM
D/E
D1/E1
D2/E2
NO. OF
PINS
**
MIN
0.385 (9,78)
MAX
MIN
MAX
MIN
MAX
0.395 (10,03)
0.350 (8,89)
0.356 (9,04)
0.141 (3,58)
0.191 (4,85)
0.291 (7,39)
0.341 (8,66)
0.169 (4,29)
0.219 (5,56)
0.319 (8,10)
0.369 (9,37)
20
28
44
52
68
84
0.485 (12,32) 0.495 (12,57) 0.450 (11,43) 0.456 (11,58)
0.685 (17,40) 0.695 (17,65) 0.650 (16,51) 0.656 (16,66)
0.785 (19,94) 0.795 (20,19) 0.750 (19,05) 0.756 (19,20)
0.985 (25,02) 0.995 (25,27) 0.950 (24,13) 0.958 (24,33) 0.441 (11,20) 0.469 (11,91)
1.185 (30,10) 1.195 (30,35) 1.150 (29,21) 1.158 (29,41) 0.541 (13,74) 0.569 (14,45)
4040005/B 03/95
NOTES: A. All linear dimensions are in inches (millimeters).
B. This drawing is subject to change without notice.
C. Falls within JEDEC MS-018
1
POST OFFICE BOX 655303 • DALLAS, TEXAS 75265
IMPORTANT NOTICE
Texas Instruments Incorporated and its subsidiaries (TI) reserve the right to make corrections, enhancements, improvements and other
changes to its semiconductor products and services per JESD46, latest issue, and to discontinue any product or service per JESD48, latest
issue. Buyers should obtain the latest relevant information before placing orders and should verify that such information is current and
complete. All semiconductor products (also referred to herein as “components”) are sold subject to TI’s terms and conditions of sale
supplied at the time of order acknowledgment.
TI warrants performance of its components to the specifications applicable at the time of sale, in accordance with the warranty in TI’s terms
and conditions of sale of semiconductor products. Testing and other quality control techniques are used to the extent TI deems necessary
to support this warranty. Except where mandated by applicable law, testing of all parameters of each component is not necessarily
performed.
TI assumes no liability for applications assistance or the design of Buyers’ products. Buyers are responsible for their products and
applications using TI components. To minimize the risks associated with Buyers’ products and applications, Buyers should provide
adequate design and operating safeguards.
TI does not warrant or represent that any license, either express or implied, is granted under any patent right, copyright, mask work right, or
other intellectual property right relating to any combination, machine, or process in which TI components or services are used. Information
published by TI regarding third-party products or services does not constitute a license to use such products or services or a warranty or
endorsement thereof. Use of such information may require a license from a third party under the patents or other intellectual property of the
third party, or a license from TI under the patents or other intellectual property of TI.
Reproduction of significant portions of TI information in TI data books or data sheets is permissible only if reproduction is without alteration
and is accompanied by all associated warranties, conditions, limitations, and notices. TI is not responsible or liable for such altered
documentation. Information of third parties may be subject to additional restrictions.
Resale of TI components or services with statements different from or beyond the parameters stated by TI for that component or service
voids all express and any implied warranties for the associated TI component or service and is an unfair and deceptive business practice.
TI is not responsible or liable for any such statements.
Buyer acknowledges and agrees that it is solely responsible for compliance with all legal, regulatory and safety-related requirements
concerning its products, and any use of TI components in its applications, notwithstanding any applications-related information or support
that may be provided by TI. Buyer represents and agrees that it has all the necessary expertise to create and implement safeguards which
anticipate dangerous consequences of failures, monitor failures and their consequences, lessen the likelihood of failures that might cause
harm and take appropriate remedial actions. Buyer will fully indemnify TI and its representatives against any damages arising out of the use
of any TI components in safety-critical applications.
In some cases, TI components may be promoted specifically to facilitate safety-related applications. With such components, TI’s goal is to
help enable customers to design and create their own end-product solutions that meet applicable functional safety standards and
requirements. Nonetheless, such components are subject to these terms.
No TI components are authorized for use in FDA Class III (or similar life-critical medical equipment) unless authorized officers of the parties
have executed a special agreement specifically governing such use.
Only those TI components which TI has specifically designated as military grade or “enhanced plastic” are designed and intended for use in
military/aerospace applications or environments. Buyer acknowledges and agrees that any military or aerospace use of TI components
which have not been so designated is solely at the Buyer's risk, and that Buyer is solely responsible for compliance with all legal and
regulatory requirements in connection with such use.
TI has specifically designated certain components as meeting ISO/TS16949 requirements, mainly for automotive use. In any case of use of
non-designated products, TI will not be responsible for any failure to meet ISO/TS16949.
Products
Applications
Audio
www.ti.com/audio
amplifier.ti.com
dataconverter.ti.com
www.dlp.com
Automotive and Transportation www.ti.com/automotive
Communications and Telecom www.ti.com/communications
Amplifiers
Data Converters
DLP® Products
DSP
Computers and Peripherals
Consumer Electronics
Energy and Lighting
Industrial
www.ti.com/computers
www.ti.com/consumer-apps
www.ti.com/energy
dsp.ti.com
Clocks and Timers
Interface
www.ti.com/clocks
interface.ti.com
logic.ti.com
www.ti.com/industrial
www.ti.com/medical
Medical
Logic
Security
www.ti.com/security
Power Mgmt
Microcontrollers
RFID
power.ti.com
Space, Avionics and Defense
Video and Imaging
www.ti.com/space-avionics-defense
www.ti.com/video
microcontroller.ti.com
www.ti-rfid.com
www.ti.com/omap
OMAP Applications Processors
Wireless Connectivity
TI E2E Community
e2e.ti.com
www.ti.com/wirelessconnectivity
Mailing Address: Texas Instruments, Post Office Box 655303, Dallas, Texas 75265
Copyright © 2013, Texas Instruments Incorporated
相关型号:
©2020 ICPDF网 联系我们和版权申明