54ACT11280 [TI]

9-BIT PARITY GENERATORS/CHECKERS; 9位奇偶发生器/跳棋
54ACT11280
型号: 54ACT11280
厂家: TEXAS INSTRUMENTS    TEXAS INSTRUMENTS
描述:

9-BIT PARITY GENERATORS/CHECKERS
9位奇偶发生器/跳棋

文件: 总5页 (文件大小:99K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
ꢀ ꢁ ꢂꢃꢄ ꢅꢅ ꢆ ꢇ ꢈ ꢉꢊ ꢋ ꢁꢂ ꢃꢄ ꢅꢅꢆ ꢇꢈ  
ꢌ ꢍꢎꢏ ꢄꢊ ꢐꢂꢑꢏ ꢄ ꢒꢊꢓ ꢔ ꢕꢔꢑꢂꢄꢖ ꢑꢗꢘ ꢃꢙꢔ ꢃꢚ ꢔ ꢑꢗ  
SCAS046A − D3148, AUGUST 1988 − REVISED APRIL 1993  
54ACT11280 . . . J PACKAGE  
74ACT11280 . . . D OR N PACKAGE  
Inputs Are TTL-Voltage Compatible  
Generates Either Odd or Even Parity for  
(TOP VIEW)  
Nine Data Lines  
Cascadable for n-Bits Parity  
B
A
C
D
E
V
1
2
3
4
5
6
7
14  
13  
12  
11  
10  
9
Flow-Through Architecture Optimizes  
Σ ODD  
GND  
Σ EVEN  
NC  
PCB Layout  
CC  
Center-Pin V  
and GND Configurations  
Minimize High-Speed Switching Noise  
CC  
F
G
H
EPICt (Enhanced-Performance Implanted  
I
8
CMOS) 1-mm Process  
500-mA Typical Latch-Up Immunity  
at 125°C  
54ACT11280 . . . FK PACKAGE  
(TOP VIEW)  
Package Options Include Plastic  
Small-Outline Packages, Ceramic Chip  
Carriers, and Standard Plastic and Ceramic  
300-mil DIPs  
3
2
1
20 19  
18  
G
C
NC  
B
4
5
6
7
8
NC  
H
description  
17  
16  
15  
14  
These universal, monolithic, 9-bit parity  
generators/checkers feature odd and even  
outputs to facilitate operation of either an odd or  
NC  
I
NC  
A
9 10 11 12 13  
even parity application.  
The word-length  
capability is easily expanded by cascading.  
The 54ACT11280 is characterized for operation  
over the full military temperature range of − 55°C  
to 125°C. The 74ACT11280 is characterized for  
operation from − 40°C to 85°C.  
NC − No internal connection  
logic symbol  
FUNCTION TABLE  
NUMBER OF INPUTS  
A THRU I  
THAT ARE HIGH  
OUTPUTS  
2
A
2k  
S EVEN  
S ODD  
1
B
0, 2, 4, 6, 8  
1, 3, 5, 7, 9  
H
L
L
14  
C
H
13  
D
5
3
Σ EVEN  
Σ ODD  
12  
E
10  
F
9
G
8
H
7
I
This symbol is in accordance with ANSI/IEEE Std 91-1984  
and IEC Publication 617-12.  
Pin numbers shown are for the D, J, and N packages.  
EPIC is a trademark of Texas Instruments Incorporated.  
ꢄꢩ  
Copyright 1993, Texas Instruments Incorporated  
ꢥ ꢩ ꢦ ꢥꢞ ꢟꢳ ꢡꢠ ꢤ ꢬꢬ ꢪꢤ ꢢ ꢤ ꢣ ꢩ ꢥ ꢩ ꢢ ꢦ ꢮ  
2−1  
POST OFFICE BOX 655303 DALLAS, TEXAS 75265  
POST OFFICE BOX 1443 HOUSTON, TEXAS 77001  
ꢀ ꢁꢂ ꢃ ꢄ ꢅꢅ ꢆꢇ ꢈ ꢉ ꢊ ꢋ ꢁꢂ ꢃꢄ ꢅꢅ ꢆ ꢇꢈ  
ꢌ ꢍꢎ ꢏ ꢄ ꢊꢐꢂ ꢑ ꢏꢄ ꢒꢊ ꢓꢔ ꢕ ꢔꢑ ꢂꢄꢖ ꢑꢗ ꢘꢃ ꢙꢔ ꢃꢚꢔ ꢑꢗ  
SCAS046A − D3148, AUGUST 1988 − REVISED APRIL 1993  
logic diagram (positive logic)  
2
A
1
B
14  
C
5
Σ EVEN  
13  
D
12  
E
10  
F
3
Σ ODD  
9
G
8
H
7
I
Pin numbers shown are for the D, J, and N packages.  
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)  
Supply voltage range, V  
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −0.5 V to 7 V  
CC  
Input voltage range, V (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −0.5 V to V  
+ 0.5 V  
+ 0.5 V  
I
CC  
CC  
Output voltage range, V (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −0.5 V to V  
O
Input clamp current, I (V < 0 or V > V ) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 mA  
IK  
I
I
CC  
Output clamp current, I  
(V < 0 or V > V ) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50 mA  
OK  
O O CC  
Continuous output current, I (V = 0 to V ) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50 mA  
Continuous current through V  
O
O
CC  
CC  
or GND . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 00 mA  
Storage temperature range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −65°C to 150°C  
Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only and  
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not  
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.  
NOTE 1: The input and output voltage ratings may be exceeded if the input and output current ratings are observed.  
2−2  
POST OFFICE BOX 655303 DALLAS, TEXAS 75265  
POST OFFICE BOX 1443 HOUSTON, TEXAS 77001  
ꢀ ꢁ ꢂꢃꢄ ꢅꢅ ꢆ ꢇ ꢈ ꢉꢊ ꢋ ꢁꢂ ꢃꢄ ꢅꢅꢆ ꢇꢈ  
ꢌ ꢍꢎꢏ ꢄꢊ ꢐꢂꢑꢏ ꢄ ꢒꢊꢓ ꢔ ꢕꢔꢑꢂꢄꢖ ꢑꢗꢘ ꢃꢙ ꢔ ꢃꢚ ꢔ ꢑꢗ  
SCAS046A − D3148, AUGUST 1988 − REVISED APRIL 1993  
recommended operating conditions  
54ACT11280  
74ACT11280  
UNIT  
MIN  
4.5  
2
MAX  
MIN  
4.5  
2
MAX  
V
V
V
V
V
Supply voltage  
5.5  
5.5  
V
V
CC  
IH  
IL  
High-level input voltage  
Low-level input voltage  
Input voltage  
0.8  
0.8  
V
0
0
V
V
0
0
V
V
V
I
CC  
CC  
Output voltage  
V
O
CC  
CC  
I
I
High-level output current  
Low-level output current  
Input transition rise or fall rate  
Operating free-air temperature  
24  
24  
24  
24  
mA  
mA  
ns/V  
°C  
OH  
OL  
Dt/Dv  
0
10  
0
10  
T
− 55  
125  
− 40  
85  
A
electrical characteristics over recommended operating free-air temperature range (unless  
otherwise noted)  
T
A
= 25°C  
54ACT11280  
74ACT11280  
PARAMETER  
TEST CONDITIONS  
V
UNIT  
CC  
MIN  
4.4  
TYP  
MAX  
MIN  
4.4  
MAX  
MIN  
4.4  
5.4  
3.8  
4.8  
MAX  
4.5 V  
5.5 V  
4.5 V  
5.5 V  
5.5 V  
I
I
= − 50 mA  
OH  
5.4  
5.4  
3.94  
4.94  
3.7  
= − 24 mA  
V
OH  
OH  
V
4.7  
{
{
3.85  
I
I
= − 50 mA  
OH  
5.5 V  
4.5 V  
5.5 V  
4.5 V  
5.5 V  
5.5 V  
3.85  
= − 75 mA  
OH  
0.1  
0.1  
0.1  
0.1  
0.1  
0.1  
I
= 50 mA  
OL  
OL  
0.36  
0.36  
0.5  
0.44  
0.44  
I
= 24 mA  
V
OL  
V
0.5  
{
1.60  
I
I
= 50 mA  
OL  
{
5.5 V  
5.5 V  
5.5 V  
1.65  
1
= 75 mA  
OL  
I
I
V = V  
or GND  
0.1  
8
1
mA  
mA  
I
I
CC  
V = V  
or GND,  
I = 0  
O
160  
80  
CC  
I
CC  
One input at 3.4 V,  
Other inputs at GND or V  
}
5.5 V  
0.9  
1
1
mA  
pF  
DI  
CC  
CC  
C
V = V  
CC  
or GND  
5 V  
3.5  
i
I
Not more than one output should be tested at a time and the duration of the test should not exceed 10 ms.  
This is the increase in supply current for each input that is at one of the specified TTL voltage levels rather than 0 V or V  
.
CC  
switching characteristics over recommended ranges of supply voltage and operating free-air  
temperature (unless otherwise noted) (see Figure 1)  
T
A
= 25°C  
TYP  
7.3  
54ACT11280  
74ACT11280  
FROM  
(INPUT)  
TO  
(OUTPUT)  
PARAMETER  
UNIT  
ns  
MIN  
1.5  
1.5  
1.5  
1.5  
MAX  
10.8  
12.5  
10.8  
12.4  
MIN  
1.5  
1.5  
1.5  
1.5  
MAX  
13.1  
15.6  
12.9  
15.7  
MIN  
1.5  
1.5  
1.5  
1.5  
MAX  
12.2  
14.3  
12.1  
14.3  
t
t
t
t
PLH  
PHL  
PLH  
PHL  
Any input  
Any input  
S EVEN  
S ODD  
8.8  
7.3  
ns  
8.6  
2−3  
POST OFFICE BOX 655303 DALLAS, TEXAS 75265  
POST OFFICE BOX 1443 HOUSTON, TEXAS 77001  
ꢀ ꢁꢂ ꢃ ꢄ ꢅꢅ ꢆꢇ ꢈ ꢉ ꢊ ꢋ ꢁꢂ ꢃꢄ ꢅꢅ ꢆ ꢇꢈ  
ꢌ ꢍꢎ ꢏ ꢄ ꢊꢐꢂ ꢑ ꢏꢄ ꢒꢊ ꢓꢔ ꢕ ꢔꢑ ꢂꢄꢖ ꢑꢗ ꢘꢃ ꢙꢔ ꢃꢚꢔ ꢑꢗ  
SCAS046A − D3148, AUGUST 1988 − REVISED APRIL 1993  
operating characteristics, V  
= 5 V, T = 25°C  
A
CC  
PARAMETER  
TEST CONDITIONS  
= 50 pF, f = 1 MHz  
L
TYP  
UNIT  
pF  
C
Power dissipation capacitance  
C
56  
pd  
PARAMETER MEASUREMENT INFORMATION  
3 V  
0 V  
Input  
(see Note B)  
1.5 V  
1.5 V  
t
t
From Output  
Under Test  
PHL  
PLH  
V
OH  
In-Phase  
Output  
50% V  
50% V  
CC  
CC  
V
C
= 50 pF  
L
OL  
500 Ω  
(see Note A)  
t
PLH  
t
PHL  
V
OH  
50% V  
CC  
Out-of-Phase  
Output  
50% V  
CC  
V
OL  
VOLTAGE WAVEFORMS  
LOAD CIRCUIT  
NOTES: A.  
C includes probe and jig capacitance.  
L
B. Input pulses are supplied by generators having the following characteristics: PRR 10 MHz, Z = 50 , t = 3 ns, t = 3 ns.  
O
r
f
C. The outputs are measured one at a time with one input transition per measurement.  
Figure 1. Load Circuit and Voltage Waveforms  
2−4  
POST OFFICE BOX 655303 DALLAS, TEXAS 75265  
POST OFFICE BOX 1443 HOUSTON, TEXAS 77001  
IMPORTANT NOTICE  
Texas Instruments Incorporated and its subsidiaries (TI) reserve the right to make corrections, modifications, enhancements, improvements,  
and other changes to its products and services at any time and to discontinue any product or service without notice. Customers should  
obtain the latest relevant information before placing orders and should verify that such information is current and complete. All products are  
sold subject to TI’s terms and conditions of sale supplied at the time of order acknowledgment.  
TI warrants performance of its hardware products to the specifications applicable at the time of sale in accordance with TI’s standard  
warranty. Testing and other quality control techniques are used to the extent TI deems necessary to support this warranty. Except where  
mandated by government requirements, testing of all parameters of each product is not necessarily performed.  
TI assumes no liability for applications assistance or customer product design. Customers are responsible for their products and  
applications using TI components. To minimize the risks associated with customer products and applications, customers should provide  
adequate design and operating safeguards.  
TI does not warrant or represent that any license, either express or implied, is granted under any TI patent right, copyright, mask work right,  
or other TI intellectual property right relating to any combination, machine, or process in which TI products or services are used. Information  
published by TI regarding third-party products or services does not constitute a license from TI to use such products or services or a  
warranty or endorsement thereof. Use of such information may require a license from a third party under the patents or other intellectual  
property of the third party, or a license from TI under the patents or other intellectual property of TI.  
Reproduction of TI information in TI data books or data sheets is permissible only if reproduction is without alteration and is accompanied  
by all associated warranties, conditions, limitations, and notices. Reproduction of this information with alteration is an unfair and deceptive  
business practice. TI is not responsible or liable for such altered documentation. Information of third parties may be subject to additional  
restrictions.  
Resale of TI products or services with statements different from or beyond the parameters stated by TI for that product or service voids all  
express and any implied warranties for the associated TI product or service and is an unfair and deceptive business practice. TI is not  
responsible or liable for any such statements.  
TI products are not authorized for use in safety-critical applications (such as life support) where a failure of the TI product would reasonably  
be expected to cause severe personal injury or death, unless officers of the parties have executed an agreement specifically governing  
such use. Buyers represent that they have all necessary expertise in the safety and regulatory ramifications of their applications, and  
acknowledge and agree that they are solely responsible for all legal, regulatory and safety-related requirements concerning their products  
and any use of TI products in such safety-critical applications, notwithstanding any applications-related information or support that may be  
provided by TI. Further, Buyers must fully indemnify TI and its representatives against any damages arising out of the use of TI products in  
such safety-critical applications.  
TI products are neither designed nor intended for use in military/aerospace applications or environments unless the TI products are  
specifically designated by TI as military-grade or "enhanced plastic." Only products designated by TI as military-grade meet military  
specifications. Buyers acknowledge and agree that any such use of TI products which TI has not designated as military-grade is solely at  
the Buyer's risk, and that they are solely responsible for compliance with all legal and regulatory requirements in connection with such use.  
TI products are neither designed nor intended for use in automotive applications or environments unless the specific TI products are  
designated by TI as compliant with ISO/TS 16949 requirements. Buyers acknowledge and agree that, if they use any non-designated  
products in automotive applications, TI will not be responsible for any failure to meet such requirements.  
Following are URLs where you can obtain information on other Texas Instruments products and application solutions:  
Products  
Amplifiers  
Applications  
Audio  
Automotive  
Broadband  
Digital Control  
Medical  
Military  
Optical Networking  
Security  
amplifier.ti.com  
dataconverter.ti.com  
www.dlp.com  
www.ti.com/audio  
Data Converters  
DLP® Products  
DSP  
Clocks and Timers  
Interface  
www.ti.com/automotive  
www.ti.com/broadband  
www.ti.com/digitalcontrol  
www.ti.com/medical  
www.ti.com/military  
www.ti.com/opticalnetwork  
www.ti.com/security  
www.ti.com/telephony  
www.ti.com/video  
dsp.ti.com  
www.ti.com/clocks  
interface.ti.com  
logic.ti.com  
power.ti.com  
microcontroller.ti.com  
www.ti-rfid.com  
Logic  
Power Mgmt  
Microcontrollers  
RFID  
Telephony  
Video & Imaging  
Wireless  
RF/IF and ZigBee® Solutions www.ti.com/lprf  
www.ti.com/wireless  
Mailing Address: Texas Instruments, Post Office Box 655303, Dallas, Texas 75265  
Copyright © 2009, Texas Instruments Incorporated  

相关型号:

54ACT11280FK

Parity Generator/Checker
ETC

54ACT11280FKR

ACT SERIES, 9-BIT PARITY GENERATOR/CHECKER, COMPLEMENTARY OUTPUT, CQCC20
TI

54ACT11280J

Parity Generator/Checker
ETC

54ACT11286FK

Parity Generator/Checker
ETC

54ACT11286J

Parity Generator/Checker
ETC

54ACT112DMQB

J-K-Type Flip-Flop
ETC

54ACT112FMQB

J-K-Type Flip-Flop
ETC

54ACT112LMQB

J-K-Type Flip-Flop
ETC

54ACT112_09

Dual JK Negative Edge-Triggered Flip-Flop
NSC

54ACT11353

DUAL 1-OF-4 DATA SELECTORS/MULTIPLEXERS WITH 3-STATE OUTPUTS
TI

54ACT11353FK

4-Input Digital Multiplexer
ETC

54ACT11353J

4-Input Digital Multiplexer
ETC