SR6DM_09 [TE]
Safety Relay SR6 D/M; 安全继电器SR6 /月型号: | SR6DM_09 |
厂家: | TE CONNECTIVITY |
描述: | Safety Relay SR6 D/M |
文件: | 总3页 (文件大小:229K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
General Purpose Relays
SCHRACK
Safety Relay SR6 D/M
n
4 pole safety relay with either
2 NO+2 NC or 3 NO+1 NC contacts
Forcibly guided contacts according to EN 50205
Rated current 8 A
n
n
n
High insulation distances for safe separation of
electrical circuits
Applications
Emergency shut-off, press control, machine control, elevator
and escalator control, safety modules
F0206-ED
Approvals
V
REG.-Nr. 128935,
Z
E214024,
T
968/EL 350.04/09
Technical data of approved types on request
Contact data
Contact configuration
3 NO contacts and 1 NC contact
or
2 NO contacts and 2 NC contacts
single contact, forcibly guided
type A according to EN 50205
micro disconnection
250 / 400 VAC
Contact set
Type of interruption
Rated voltage / max. switching voltage AC
Rated current
Maximum breaking capacity AC
Contact material
Minimum contact load
Contact resistance
8 A
2000 VA
AgSnO2
10 mA / 5 V
w 100 mOhm / 1 A / 24 VDC
w 20 Ohm / 10 mA / 5 VDC
6 min-1 / 150 min-1
Rated frequency of operation with / without load
Contact ratings
Type Contact Load*)
Ambient
temp. [°C]
Cycles
EN60947-5-1
SR6
SR6
1 NO
1 NO
IEC 947-5-1 (AC15) utilization category 250 VAC / 5 A
IEC 947-5-1 (DC13) utilization category 24 VDC / 6 A
23°C
23°C
6,050
6,050
*) load on one pole
Coil data
Rated coil voltage range DC coil
Operative range to IEC 61810
5...110 VDC
2
Coil versions, DC-coil
Coil
Rated
voltage
VDC
5
Operate
voltage
VDC
3.8
Release / Reset
Coil
Rated coil
power
mW
code
voltage
VDC
0.5
resistance
Ohm
005
006
009
012
018
021
024
036
040
048
060
110
21+10%
1190
1200
1191
1200
1200
1198
1200
1200
1200
1200
1200
1200
6
9
4.5
0.6
30+10%
6.8
9.0
0.9
68+10%
12
1.2
120+10%
270+10%
368+10%
480+10%
1080+10%
1333+10%
1920+10%
3000+12%
10080+12%
18
13.5
15.8
18.0
27.0
30.0
36.0
45.0
82.5
1.8
21
2.1
24
2.4
36
3.6
40
4.0
48
4.8
60
6.0
110
11.0
All figures are given for coil without preenergization, at ambient temperature +23°C
Other coil voltages on request
1
Datasheet Rev. IJ1
Issued 2009/10
www.tycoelectronics.com
www.schrackrelays.com
Dimensions are in mm unless
otherwise specified and are
shown for reference purposes
only.
Product specification
processing information only
to be used together with the
'Definitions' section in the cat-
alogue or at schrackrelays.com
in the ‘Schrack’ section.
according to IEC 61810-1.
Product data, technical para-
meters, test conditions and
Specifications subject to
change.
General Purpose Relays
SCHRACK
Safety Relay SR6 D/M (Continued)
Insulation
PCB layout / terminal assignment
Bottom view on solder pins
Dielectric strength coil-contact circuit
open contact circuit
3000 Vrms
1500 Vrms
adjacent contact circuits 3000 / 4000 Vrms (in longitudinal direction)
Clearance / creepage coil-contact circuit
adjacent contact circuits
W 5.5 / 5.5 mm
W 5.5 / 5.5 mm
W 15 / 15 mm (in longitudinal direction)
2 NO+2 NC versions
Material group of insulation parts
Tracking index of relay base
Insulation to IEC 61810-1
IIIa
PTI 250
Type of insulation coil-contact circuit
open contact circuit
basic
micro disconnection
adjacent contact circuits reinforced (in longitudinal dir)
S0368-CI
Rated insulation voltage
Pollution degree
Rated voltage system
Overvoltage category
250 V
2
230 / 400 V
III
Insulation to EN 50178
Type of insulation coil-contact circuit
adjacent contact circuits
reinforced
reinforced
S0368-CJ
Other data
Mechanical endurance
Material
10x106 cycles
3 NO + 1 NC version
RoHS - Directive 2002/95/EC
Environment
Ambient temperature range
compliant as per product date code 0407
-25...+70°C
Vibration resistance (function) NO / NC contact > 8 / 2.5 g, 10....200 Hz
Shock resistance (function) NO / NC contact > 10 / 2.5 g, 16 ms half sine
Category of protection
Processing
RT III1)
Resistance to soldering heat
260°C / 5 s
30 g
10 pcs
Relay weight
S0368-CK
Packaging unit
1) please contact technical support for washing parameters
Accessories
PCB socket and hold down clip
contact technical support
S0368-CL
Dimensions
S0367-DB
2
Datasheet Rev. IJ1
Issued 2009/10
www.tycoelectronics.com
www.schrackrelays.com
Dimensions are in mm unless
otherwise specified and are
shown for reference purposes
only.
Product specification
processing information only
to be used together with the
'Definitions' section in the cat-
alogue or at schrackrelays.com
in the ‘Schrack’ section.
according to IEC 61810-1.
Product data, technical para-
meters, test conditions and
Specifications subject to
change.
General Purpose Relays
SCHRACK
Safety Relay SR6 D/M (Continued)
Product key
Typical product key
SR6
D
4
012
Type
SR6 Safety Relay SR6 D/M
Contact configuration
D
M
2 NO + 2 NC contacts (2 form A + 2 form B)
3 NO + 1 NC contacts (3 form A + 1 form B)
Contact material
AgSnO2
4
Coil
Coil code = rated coil voltage (e.g. 024=24 VDC)
Other types on request
Product key
SR6D4012
SR6D4018
SR6D4021
SR6D4024
SR6D4040
SR6D4110
SR6M4006
SR6M4012
SR6M4018
SR6M4021
SR6M4024
SR6M4110
Type
4-pole
safety relay
Contact configuration Contact material
Coil
Part number
1415078-1
7-1415354-1
8-1415353-1
6-1415027-1
9-1415366-1
1415062-1
6-1415053-1
7-1415353-1
1415354-1
6-1415353-1
3-1415353-1
1-1415354-1
2 NO + 2 NC
contacts
AgSnO2
12 VDC
18 VDC
21 VDC
24 VDC
40 VDC
110 VDC
6 VDC
3 NO + 1 NC
contacts
12 VDC
18 VDC
21 VDC
24 VDC
110 VDC
3
Datasheet Rev. IJ1
Issued 2009/10
www.tycoelectronics.com
www.schrackrelays.com
Dimensions are in mm unless
otherwise specified and are
shown for reference purposes
only.
Product specification
processing information only
to be used together with the
'Definitions' section in the cat-
alogue or at schrackrelays.com
in the ‘Schrack’ section.
according to IEC 61810-1.
Product data, technical para-
meters, test conditions and
Specifications subject to
change.
相关型号:
©2020 ICPDF网 联系我们和版权申明