SPM05-20R [TDK]

DC-DC Regulated Power Supply Module, 1 Output, 100W, Hybrid;
SPM05-20R
型号: SPM05-20R
厂家: TDK ELECTRONICS    TDK ELECTRONICS
描述:

DC-DC Regulated Power Supply Module, 1 Output, 100W, Hybrid

文件: 总12页 (文件大小:116K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
A222_SPM  
(1/12)  
TDK Switching Power Supply  
Ultra-thin type DC.24V input  
S SERIES SPM  
[FEATURES]  
• DC.24V input ultra-thin type single output power supply.  
• Plastic package, onboard type.  
• Remote ON-OFF function.  
• Remote sensing function.  
• Ultra-light.  
[SUMMARY]  
The S series SPL/SPM/SPH products have an ultra-thin onboard  
type feature. A full product lineup is available such as input  
voltages DC.12V (SPL), 24V (SPM), and 48V (SPH). It is possible  
to take out large current with the output capacity 50W or 100W.  
With enhanced remote ON-OFF and remote sensing functions,  
you can apply the products to a further variety of uses.  
PART NUMBERS AND RATINGS  
50W Type  
100W Type  
Input voltage range  
(V)  
Output voltage(V)  
Current(A) Part No.  
Current(A) Part No.  
5
10  
SPM05-10R  
20  
SPM05-20R  
DC.20 to 30  
DC.20 to 30  
DC.20 to 30  
DC.20 to 30  
12  
15  
24  
4.2  
3.4  
2.1  
SPM12-4R2  
SPM15-3R4  
SPM24-2R1  
8.3  
6.6  
4.2  
SPM12-8R3  
SPM15-6R6  
SPM24-4R2  
• To take out rated output power, take into consideration introducing a radiator, a forcible air-cooling, or the like.  
• The above products are only produced upon receipt of order. Please check a delivery date.  
All specifications are subject to change without notice.  
A222_SPM  
(2/12)  
TDK Switching Power Supply  
S SERIES SPM50W TYPE  
SPECIFICATIONS AND STANDARDS  
PART NO.  
SPM05-10R  
5V • 10A  
50  
SPM12-4R2  
12V • 4.2A  
50.4  
SPM15-3R4  
15V • 3.4A  
51  
SPM24-2R1  
24V • 2.1A  
50.4  
Rated output voltage and current  
Maximum output power 1  
INPUT CONDITIONS  
Input voltage Edc  
Input current  
W
V
20 to 30[Rating: 24]  
2.9typ./3.5max.[DC.24/20V]  
81typ.  
A
Efficiency  
%
84typ.  
85typ.  
85typ.  
OUTPUT CHARACTERISTICS  
Output voltage Edc  
V
5
12  
15  
24  
Voltage variable range 2 Edc  
Maximum output current  
Output voltage setting deviation  
Overvoltage threshold Edc  
Overcurrent threshold  
Input variation  
V
4.5 to 5.5  
10  
10.8 to 13.2  
4.2  
13.5 to 16.5  
3.4  
21.6 to 26.4  
2.1  
A
%
±5max.[Without external resistance and external trim]  
V
5.5 to 6.9  
13.7 to 15.7  
4.3 to 5.7  
17 to 19  
27 to 30.5  
2.2 to 2.9  
A
10.3 to 13.5  
3.5 to 4.5  
%
2max.(1typ.)[Within the input voltage range]  
2max.(1typ.)[10 to 100% load]  
Load variation  
Voltage  
%
Total variation 6max.(3typ.)  
Temperature variation  
%
2max.(1typ.)[Ambient temperature: 0 to +60°C]  
stability  
Drift  
%
2max.(0.1typ.)[25°C, input and output ratings, after input voltage ON for 30min to 8h]  
±4max./1ms[50 to 100% sudden load change]  
Dynamic load  
%/ms  
mV  
mV  
Ripple Ep-p  
150max.  
250max.  
200max.  
300max.  
200max.  
300max.  
200max.  
400max.  
Ripple noise Ep-p  
AUXILIARY FUNCTIONS  
Overvoltage protection  
Overcurrent protection  
Remote ON-OFF  
Remote sensing  
STANDARDS  
Voltage shut-down type, recovers upon reset.  
Fixed current and voltage threshold type, automatic recovery.  
Yes  
Yes  
Safety standards  
CONSTRUCTIONS  
External dimensions  
Weight  
mm  
g
12.7×58×115[H×W×L]  
150max.  
Mounting method  
Case material  
Can be attached to terminal side (soldered and screwed).  
Nonflammable resin[UL94-V0]  
Sold separately(Part No.: 3JR0AB179)  
Heat sink  
1 Radiant heating and forced air cooling should be considered. Sufficient space should be provided so that the base plate(aluminum surface) temperature  
is below 85°C when the surrounding environment is less than 60°C.  
2 Terminals should be wired as indicated below.  
+S  
• When +S is not connected to the +terminal, and when –S is not connected to the –terminal, output voltage rises due to the  
+
+
sense amp open circuit. Output can then halt due to the overvoltage protection function. Also RV1 and RV2 should be left  
open if output voltage is not adjusted.  
+
Load  
Recommended external resistance values  
Output voltage rating(V)  
External trim()  
5
12  
15  
24  
–S  
10k  
1k  
10k  
5.6k  
10k  
10k  
10k  
27k  
External trim  
External resistance()  
RV2  
For details of the connections or the like, refer to the descriptions in Characteristics, Functions,  
and Applications on the later pages.  
External  
resistance  
RV1  
All specifications are subject to change without notice.  
A222_SPM  
(3/12)  
TDK Switching Power Supply  
S SERIES SPM50W TYPE  
Dimensions in mm  
SHAPES AND DIMENSIONS  
SPM50W TYPE  
±0.3mm : without specified dimensions  
2-M3 Tap(For heat sink installation)  
(Recommend torque: 0.69Nm)  
1.2  
t: 0.3±0.05  
[Detail drawing of A portion]  
5.5±0.5  
104±0.7  
115±1  
(5.5)  
[Output side]  
[Input side]  
RC  
–S  
– + +S  
+ –  
A
Diameter of terminal pin: ø0.7±0.1  
6±0.5  
(5.5)  
103.5±0.7  
(5.5)  
104±0.7  
5.5±0.5  
2-M4 Tap(For customer use)  
(Recommend torque: 1.08Nm)  
Note)  
• Do not insert M3 and M4 installation screws more than 6mm from surface of power supply.  
All specifications are subject to change without notice.  
A222_SPM  
(4/12)  
TDK Switching Power Supply  
S SERIES SPM100W TYPE  
SPECIFICATIONS AND STANDARDS  
Part No.  
SPM05-20R  
5V • 20A  
100  
SPM12-8R3  
12V • 8.3A  
99.6  
SPM15-6R6  
15V • 6.6A  
99  
SPM24-4R2  
24V • 4.2A  
100.8  
Rated output voltage and current  
Maximum output power 1  
INPUT CONDITIONS  
Input voltage Edc  
Input current  
W
V
20 to 30[Rating: 24]  
5.6typ./6.7max.[DC.24/20V]  
80typ.  
A
Efficiency  
%
83typ.  
85typ.  
86typ.  
OUTPUT CHARACTERISTICS  
Output voltage Edc  
V
5
12  
15  
24  
Voltage variable range 2 Edc  
Maximum output current  
Output voltage setting deviation  
Overvoltage threshold Edc  
Overcurrent threshold  
Input variation  
V
4.5 to 5.5  
20  
10.8 to 13.2  
8.3  
13.5 to 16.5  
6.6  
21.6 to 26.4  
4.2  
A
%
V
±5max.[Without external resistance and external trim]  
5.5 to 6.9  
20.6 to 27  
13.7 to 15.7  
8.5 to 11.2  
17 to 19  
27 to 30.5  
4.3 to 5.7  
A
6.8 to 8.9  
%
%
%
%
2max.(1typ.)[Within the input voltage range]  
2max.(1typ.)[10 to 100% load]  
Load variation  
Total variation 6max.(3typ.)  
Voltage Temperature variation  
2max.(1typ.)[Ambient temperature: 0 to +60°C]  
stability  
Drift  
2max.(0.1typ.)[25°C, input and output ratings, after input voltage ON for 30min to 8h]  
±4max./1ms[50 to 100% sudden load change, however, 5V output is assumed when the 680µF electrolytic  
capacitor is connected to the loaded terminal.]  
Dynamic load  
%/ms  
Ripple Ep-p  
mV  
mV  
150max.  
250max.  
200max.  
300max.  
200max.  
300max.  
200max.  
400max.  
Ripple noise Ep-p  
AUXILIARY FUNCTIONS  
Overvoltage protection  
Overcurrent protection  
Remote ON-OFF  
Remote sensing  
STANDARDS  
Voltage shut-down type, recovers upon reset.  
Fixed current and voltage threshold type, automatic recovery.  
Yes  
Yes  
Safety standards  
CONSTRUCTIONS  
External dimensions  
Weight  
mm  
g
12.7×58×115[H×W×L]  
150max.  
Mounting method  
Case material  
Can be attached to terminal side (soldered and screwed).  
Nonflammable resin[UL94-V0]  
Sold separately(Part No.: 3JR0AB179)  
Heat sink  
1 Radiant heating and forced air cooling should be considered. Sufficient space should be provided so that the base plate(aluminum surface) temperature  
is below 85°C when the surrounding environment is less than 60°C.  
2 Terminals should be wired as indicated below.  
+S  
• When +S is not connected to the +terminal, and when –S is not connected to the –terminal, output voltage rises due to the  
sense amp open circuit. Output can then halt due to the overvoltage protection function. Also RV1 and RV2 should be left  
open if output voltage is not adjusted.  
+
+
+
Load  
Recommended external resistance values  
Output voltage rating(V)  
External trim()  
5
12  
15  
24  
–S  
10k  
1k  
10k  
5.6k  
10k  
10k  
10k  
27k  
External trim  
External resistance()  
RV2  
For details of the connections or the like, refer to the descriptions in Characteristics, Functions,  
and Applications on the later pages.  
External  
resistance  
RV1  
All specifications are subject to change without notice.  
A222_SPM  
(5/12)  
TDK Switching Power Supply  
S SERIES SPM100W TYPE  
Dimensions in mm  
SHAPES AND DIMENSIONS  
SPM100W TYPE  
±0.3mm : without specified dimensions  
2-M3 Tap(For heat sink installation)  
(Recommend torque: 0.69Nm)  
1.2  
t: 0.3±0.05  
[Detail drawing of A portion]  
5.5±0.5  
104±0.7  
115±1  
(5.5)  
[Output side]  
[Input side]  
RC  
–S  
– + +S  
+ –  
A
Diameter of terminal pin: ø0.7±0.1  
(5.5)  
6±0.5  
103.5±0.7  
(5.5)  
104±0.7  
5.5±0.5  
2-M4 Tap(For customer use)  
(Recommend torque: 1.08Nm)  
Note)  
• Do not insert M3 and M4 installation screws more than 6mm from surface of power supply.  
All specifications are subject to change without notice.  
A222_SPM  
(6/12)  
TDK Switching Power Supply  
Characteristics, Functions, and Applications  
BLOCK DIAGRAM  
SG  
Input  
filter  
circuit  
Output rectifying  
and  
smoothing circuit  
+
+
DC input  
DC output  
COM  
RC  
Over-  
Power  
switching  
circuit  
current  
detection  
circuit  
RC  
control circuit  
Drive  
circuit  
RV1  
RV2  
+S  
–S  
Control circuit  
Control circuit  
OC 1  
OC 2  
GATE  
Overvoltage  
detection  
circuit  
COMMON SPECIFICATIONS  
Temperature and humidity  
0 to +60 Derating is necessary when operating environment temperature exceed 40°C  
(Case temperature: +85°C max.)  
.
Operating(°C)  
Temperature range  
Storage(°C)  
–25 to +105  
Operating(%)RH  
Storage(%)RH  
Humidity range  
20 to 95[Maximum wet-bulb temperature: 35°C, without dewing]  
Amplitude and vibration  
5 to 10Hz  
All amplitude 10mm[3 directions, each 1h]  
Acceleration 19.6m/s2 [2G, 3 directions, each 1h]  
196m/s2 [20G, 3 directions, each 3 times]  
11±5ms  
Amplitude  
10 to 55Hz  
Acceleration  
Vibration time  
Vibration  
Withstand voltage and insulation resistance  
Input terminal to output terminal  
Input terminal to signal ground terminal  
Withstand voltage  
1min  
(25°C, 45 to 75(%)RH)  
Edc(V)500,  
Input terminal to output terminal  
Insulation resistance  
Input terminal to signal ground terminal  
Output terminal to signal ground terminal  
Edc(V)500, 100Mmin.(25°C, 45 to 75(%)RH)  
All specifications are subject to change without notice.  
A222_SPM  
(7/12)  
TDK Switching Power Supply  
Characteristics, Functions, and Applications  
TERMINAL DESIGNATIONS AND FUNCTIONS  
1
9
10  
11  
12  
13  
14  
2
3
4
Aluminum side  
5
6
7
8
Aluminum side  
Terminal side  
1
2
DC input terminal(+) .................................................... Connect these terminals to DC input power supply.  
DC input terminal(–)  
3
4
5
Signal ground terminal(SG) ........................................... Connected to a case (aluminum side). Connect this terminal to the DC input terminal (–) or (+). Can be  
connected to FG in the unit side.  
Common terminal(COM) ................................................ Connected to the DC input terminal (–) via an input filter. Use it for the common mode of the signal  
system (OC1.RC) in the input side.  
Remote ON-OFF terminal(RC) ....................................... The output voltage can be turned on or off by applying a voltage of the TTL level to a portion between  
this RC terminal and the COM terminal. Turned on at a high level for the RC and COM terminals or  
when they are on and turned off at a low level for them or when they are off.  
6
7
8
9
Overcurrent detection terminal 1(OC1) ........................ For use in power supply overcurrent setting. Connect the OC1 to the COM in a single unit operation.  
The distance between them should be as short as possible.  
Overcurrent detection terminal 2(OC2) ........................ Adjustment terminal inside the power supply. Release it without use. A use of this terminal for a junction  
terminal or the like will cause a damage or malfunction.  
Gate terminal(GATE) ...................................................... Adjustment terminal inside the power supply. Release it without use. A use of this terminal for a junction  
terminal or the like will cause a damage or malfunction.  
Remote sensing terminal(+S) ..................................... Connect these terminals at load ends in remote sensing. Unless the remote sensing is used, connect  
12 Remote sensing terminal(–S)  
them to respective DC output terminals.  
10 DC output terminal(+)  
11 DC output terminal(–)  
................................................. Power supply output terminals. Connect them to a load line.  
13 Output voltage external variable terminal(RV2)  
14 Output voltage external variable terminal(RV1)  
...... Output voltage can be externally adjusted by approx. ±10% of the rated output voltage by connecting  
resistances between the RV1 and RV2 terminals and between the RV2 and –S terminals. Release  
these terminals unless they are in use.  
All specifications are subject to change without notice.  
A222_SPM  
(8/12)  
TDK Switching Power Supply  
Characteristics, Functions, and Applications  
INPUT-OUTPUT TERMINAL BASIC CONNECTION  
2) Single operation with RC  
: Power line connection  
: Signal line connection  
• IN+  
• IN–  
• SG  
+S •  
OUT+ •  
OUT– •  
+
FUSE  
CR  
Cin  
• IN+  
• IN–  
• SG  
+S •  
OUT+ •  
OUT– •  
• COM  
Load  
Co  
• RC  
• COM  
• OC1  
• OC2  
• GATE  
–S •  
RV2 •  
RV1 •  
VR1  
R1  
• RC  
• OC1  
• OC2  
• GATE  
–S •  
RV2 •  
RV1 •  
Output can be turned on or off by adding a signal of the TTL level  
between the RC terminal and the COM terminal or by releasing  
the connection between the terminals.  
RECOMMENDED FUSE CAPACITY (A)  
50W  
100W  
Between RC and COM:  
SPM  
6.3-10 15-20  
At high level (2.4 to 5V) or when open: ON  
At low level (0 to 0.4V) or when short: OFF  
NOTES  
The remote ON-OFF circuit is connected to a primary circuit  
inside the power supply. Therefore, it is recommended to use an  
element having an insulating function such as a relay (chattering  
preventive measures on contacts are required), a photo coupler,  
or the like as an external control circuit. In case of being  
compelled to use a non-insulation circuit, do not use a COM  
terminal, but use an input (–) terminal. It should be noted that,  
however, noise to the input terminal must be suppressed to the  
minimum in the above case. In addition, be careful with a release  
of the input terminal; if the input terminal is released, large current  
flows into the COM pattern, by which the pattern may be burned  
and damaged. The RC terminal is pulled up to 5V inside the  
power supply. Release it when it is not in use.  
• No input fuse is incorporated. It is recommended to externally  
mount a protection fuse (normal melting type fuse) and reverse  
connection preventing diodes (CR). As for a selection of  
diodes, select ones having current characteristics twice or three  
times the fuse rated current for taking into consideration fuse  
melting characteristics.  
• If an impedance of the input line is high, install an electrolytic  
capacitor (Cin) between power supply input terminals of a high  
ripple type.  
• High impedance conditions  
1. Long input wire  
2. Thin input wire  
3. Filter on input line  
• If the wire in the load side is long, an oscillation may be caused  
by an effect of inductance or noise.  
Insulation type recommended circuit  
RC  
If the oscillation easily occurs, connect an aluminum electrolytic  
capacitor having 100µF (Co) or higher between OUT+ and  
OUT– of the power supply.  
COM  
CONNECTION METHOD  
Non-insulation type  
1) Single operation with output voltage adjustment function  
RC  
100  
• IN+  
• IN–  
• SG  
+S •  
OUT+ •  
OUT– •  
0.1µF  
• COM  
IN  
• RC  
1 For the SPL type, the rise time or the fall time of a signal to the RC terminal  
should be 2ms or shorter.  
• OC1  
• OC2  
• GATE  
–S •  
RV2 •  
RV1 •  
VR1  
R1  
2 An input signal to the RC terminal should be accompanied by little chattering.  
Chattering for 0.1ms or more may cause a malfunction in an output of the  
power supply.  
• Recommended external resistance value (When using  
output voltage adjustment function)  
3) Single operation with remote sensing  
Output voltage(V)  
VR1()  
5
12  
15  
24  
C1  
10k  
1k  
10k  
5.6k  
10k  
10k  
10k  
27k  
• IN+  
• IN–  
• SG  
+S •  
OUT+ •  
OUT– •  
R1()  
• Output voltage can be adjusted by approx. ±10% with the  
recommended external resistance value. It should be noted  
that, however, the resistance must be used within the output  
power range.  
Load  
• COM  
C2  
• RC  
• OC1  
• OC2  
• GATE  
–S •  
RV2 •  
RV1 •  
VR1  
R1  
All specifications are subject to change without notice.  
A222_SPM  
(9/12)  
TDK Switching Power Supply  
Characteristics, Functions, and Applications  
NOTES  
5) Serial operation  
• Remote sensing is possible for a line drop between the +S and  
OUT+ (–S and OUT–) terminals up to the following levels:  
5V output: 0.25V or lower  
• IN +  
• IN –  
• SG  
+S •  
OUT+ •  
OUT– •  
CR1  
• COM  
12 to 24V output: 0.4V or lower  
• RC  
• By using a shielded wire or a stranded wire is used as a remote  
sensing wire, effects of noise can be reduced. If the  
overvoltage protection is easily activated or oscillation easily  
occurs, attach C1 and C2 capacitors of 0.1µF or higher  
between the +S and OUT+ terminals and between the –S and  
OUT– terminals to check the output voltage (Refer to the above  
diagram).  
–S  
RV2  
RV1  
• OC1  
• OC2  
• GATE  
• IN +  
• IN –  
• SG  
+S •  
OUT+ •  
OUT– •  
CR2  
• COM  
• If an electrolytic capacitor is used, be careful with polarities.  
• The rise time is extended due to the capacity of the  
electrolytic capacitor.  
VR1  
• RC  
–S  
RV2  
RV1  
• OC1  
• OC2  
• GATE  
R1  
4) Parallel operation  
NOTES  
• In serial operation, attach the diodes CR1 and CR2 for  
preventing reverse voltage application without fail.  
• CR setting conditions  
• IN+  
• IN–  
• SG  
+S •  
OUT+ •  
OUT– •  
• COM  
Reverse withstand voltage: Twice or more each output voltage  
Forward current: Twice or more each output current  
Forward voltage loss: As small as possible  
VR1  
R1  
• RC  
• OC1  
• OC2  
• GATE  
–S •  
RV2 •  
RV1 •  
• The maximum current is equal to a value of the output current  
of a power supply having the smallest output current of the  
power supplies in the serial connection.  
• IN+  
• IN–  
• SG  
+S •  
OUT+ •  
OUT– •  
• COM  
RECOMMENDED PIN PATTERN (TOP VIEW)  
VR1  
R1  
• RC  
103.5  
• OC1  
• OC2  
• GATE  
–S •  
RV2 •  
RV1 •  
NOTES  
• In parallel operation, use the power supplies within 80% of the  
rated power of each power supply.  
104  
Input side  
Output side  
SG tap portion  
• Wiring impedance should be equalized as completely as  
possible from each power supply to a load.  
0.5  
• To increase a precision of an output current balance, set a  
dispersion of respective output voltages to 1% or lower at VR1.  
• In parallel operation, release the OC1 terminal. The release of  
the OC1 terminal causes the overcurrent setting value to be  
automatically set to 80% of the rated current.  
103.5  
• In parallel operation, up to 8 units can be connected. It should  
be noted that, however, the units must be of the same type.  
Check that there is no malfunction in the output caused by a  
mutual interference before use.  
(Unit: mm)  
)
Input terminal  
hole dia.: ø1  
Output terminal  
hole dia.: ø1.5  
SG connection  
tap portion (  
Round dia.: ø3  
Round dia.: ø4 to 6  
Hole dia.: ø4.5  
Round dia.: ø8.5 to 9.5  
All specifications are subject to change without notice.  
A222_SPM  
(10/12)  
TDK Switching Power Supply  
Characteristics, Functions, and Applications  
OUTPUT POWER-AMBIENT TEMPERATURE(DERATINGS)  
[SPM50W TYPE]  
With heat sink(3JR0AB179)  
Without heat sink  
100  
Velocity of wind =1m/s  
0.5m/s  
100  
95  
80  
60  
40  
80  
70  
65  
60  
55  
0m/s  
53  
50  
46  
Velocity of wind =3m/s  
2.1m/s  
1.7m/s  
Available operating range  
(outside of warranty)  
4041  
30  
25  
1.0m/s  
20  
20  
0m/s  
Available operating range  
(outside of warranty)  
–10  
10  
30  
50  
–10  
10  
30  
50  
0
20  
40  
60  
0
20  
40  
60  
Ambient temperature(°C)  
Ambient temperature(°C)  
Without heat sink  
DYNAMIC LOAD VARIATION CHARACTERISTICS  
100  
Load current  
90  
88  
100%  
Velocity of wind =1.7m/s  
80  
95%  
Load current  
75  
70  
1m/s  
60  
57  
0.5m/s  
55%  
Available operating range  
(outside of warranty)  
50%  
40  
20  
35  
0m/s  
tr  
tf  
tr,tf 50µs  
Output voltage  
1% of rated voltage  
Output voltage  
Voltage variation  
–10  
10  
30  
45 50 55  
0
20  
40  
60  
Voltage variation  
Ambient temperature(°C)  
[SPM100W TYPE]  
With heat sink(3JR0AB179)  
Recovery time  
Velocity of wind =3m/s  
100  
The voltage variations depend upon conditions of the input voltage and the load  
current.  
95  
85  
8082  
2.1m/s  
1.7m/s  
71  
DYNAMIC LOAD VARIATION IMPROVING METHOD  
To suppress voltage variations, connect an external capacitor in  
the load side of the output.  
60  
55  
1.0m/s  
50  
It should be noted that, however, a connection of too many  
capacitors may cause an oscillation. Therefore, pay particular  
attention to the number of the units. Particularly when using  
laminated ceramic capacitors or tantalum capacitors, it is  
recommended to connect the least number of capacitors or to  
use capacitors together with electrolytic capacitors.  
40  
Available operating range  
(outside of warranty)  
20  
16  
0m/s  
–10  
10  
30  
42  
40  
50  
57  
0
20  
60  
Ambient temperature(°C)  
All specifications are subject to change without notice.  
A222_SPM  
(11/12)  
TDK Switching Power Supply  
Characteristics, Functions, and Applications  
MOUNTING METHOD  
• Fixing method  
In fixing to the PC board, use mounting taps at two places in the  
side of the lower surface (terminal side). Use M4 screws for fixing  
and pay attention not to insert the screws 6mm or deeper from  
the surface of the body (Recommended clamping torque: 1.08N •  
m).  
In fixing a radiator, use mounting taps at two places in the upper  
surface of the case (aluminum plate side). Use M3 screws for  
fixing and pay attention not to insert the screws 6mm or deeper  
from the surface of the body (Recommended clamping torque:  
0.69N • m).  
In addition, it is recommended to use thermal conducting grease  
to enhance a radiating effect between the radiator and the power  
supply body (aluminum surface) when mounting.  
• Pattern width  
Large current flows into the input-output pattern. It may cause a  
voltage drop or heat developed. Be very careful with designing  
the pattern. The pattern width should be determined on the basis  
of a reference value of 1mm/A.  
• Recommended soldering conditions  
Dip: 230±5°C, 5s  
• Recommended cleaning conditions  
Partially clean the PC board pattern surface. The recommended  
conditions are as follows:  
Cleaning fluid: IPA  
Cleaning method: Brush cleaning  
* See that the cleaning fluid does not permeate into the inside of the power  
supply. It may cause a trouble.  
All specifications are subject to change without notice.  
A222_SPM  
(12/12)  
TDK Switching Power Supply  
Separately-sold Option List  
Product name  
Heat sink  
Part No.  
Applicable device  
Shapes and dimensions (mm)  
3JR0AB179  
SPM50W  
SPM100W  
(10.2)  
4.3×22=94.6  
23-R0.5  
(10.2)  
1.2  
115±0.35  
104±0.3  
(5.5)  
5.5  
2-ø3.5  
Material: Aluminum  
Use cooling grease at mounting.  
Please specify the part No. for ordering.  
A222_SPM  
001127  
All specifications are subject to change without notice.  

相关型号:

SPM1-051

Modular Switching Power Supply Type SPM 1 DIN rail mounting
CARLOGAVAZZI

SPM1-121

Modular Switching Power Supply Type SPM 1 DIN rail mounting
CARLOGAVAZZI

SPM1-151

Modular Switching Power Supply Type SPM 1 DIN rail mounting
CARLOGAVAZZI

SPM1-241

Modular Switching Power Supply Type SPM 1 DIN rail mounting
CARLOGAVAZZI

SPM1004

12V Input 6A Output Power Supply in Inductor (PSI2) Module
SUMIDA

SPM1004-0V8C

12V Input 6A Output Power Supply in Inductor (PSI2) Module
SUMIDA

SPM1004-1V0C

DC-DC Regulated Power Supply Module, 1 Output, 6.6W, Hybrid, LGA-73
SUMIDA

SPM1004-1V2C

12V Input 6A Output Power Supply in Inductor (PSI2) Module
SUMIDA

SPM1004-1V5C

DC-DC Regulated Power Supply Module, 1 Output, 9.9W, Hybrid, LGA-73
SUMIDA

SPM1004-1V8C

DC-DC Regulated Power Supply Module, 1 Output, 11.88W, Hybrid, LGA-73
SUMIDA

SPM1004-2V5C

12V Input 6A Output Power Supply in Inductor (PSI2) Module
SUMIDA

SPM1004-3V3C

12V Input 6A Output Power Supply in Inductor (PSI2) Module
SUMIDA