MAX-354-1224 [SLPOWER]

250, 350 WATTS MULTIPLE OUTPUT; 250 , 350瓦多输出
MAX-354-1224
型号: MAX-354-1224
厂家: SL Power Electronics    SL Power Electronics
描述:

250, 350 WATTS MULTIPLE OUTPUT
250 , 350瓦多输出

输出元件
文件: 总2页 (文件大小:96K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
2 5 0 , 3 5 0 WATTS  
MULTIP LE OUTP UT  
MAX-250 MAX-350  
MTC-250 MTC-350  
MTX-250 MSC-350  
Featuring:  
• Over 3 watt/in3 power density  
• 80% overall efficiency  
• Meets international safety agency  
requirements  
• All outputs regulated ± 1%  
• High peak currents for motor  
starting  
• System air or self-cooling  
options  
• AC automatic line  
selection option  
• Available in 24, 28,  
or 48 Vdc input  
Option C  
STANDARD MAX SERIES  
MODEL  
PWR OUTPUT #1  
OUTPUT #2  
OUTPUT #3  
OUTPUT #4  
MAX-254-1205  
MAX-353-0512  
MAX-354-1205  
MAX-354-1212  
MAX-354-1224  
250  
350  
350  
350  
350  
+5V @ 35A  
+5V @ 50A  
+5V @ 50A  
+5V @ 50A  
+5V @ 50A  
+12V @ 8/12A pk  
+12V @ 8/12A pk  
+12V @ 8/12A pk  
+12V @ 8/12A pk  
+12V @ 8/12A pk  
-12V @ 4A  
-12V @ 4A  
-12V @ 4A  
-12V @ 4A  
-12V @ 4A  
-5.2V @ 2A  
-5.2V @ 2A  
12V @ 2A  
+24V @ 1.5A  
TELECOM MTC SERIES  
MODEL  
PWR  
OUTPUT #1  
OUTPUT #2  
OUTPUT #3  
Option V  
MTC-253-0515  
MTC-353-0512  
MTC-353-0515  
250  
350  
350  
+5V @ 30A  
+5V @ 45A  
+5V @ 45A  
+15V @ 4A  
+12V @ 6A  
+15V @ 5A  
-15V @ 4A  
-12V @ 6A  
-15V @ 5A  
The appropriate MTC, MAX, or MTX in  
your telecom product gives you the out-  
puts you need for ISDN, LAN, and T1  
applications and standard voice and data  
networks. High-current auxiliary outputs  
provide regulation characteristics for prop-  
er operation of line drivers, network inter-  
faces and RS232-type outputs. Or, use  
a 9-inch MSC in your computer-based  
product for needed output regulation,  
power for 50 Amps of logic and four hard  
disk drives.  
MASS STORAGE MSC SERIES  
MODEL  
PWR  
OUTPUT #1  
OUTPUT #2  
OUTPUT #3  
MSC-353-0512  
350  
+5V @ 30A  
+12V @ 20/2 A pk  
-12V @ 4A  
SMALL COMPUTER MTX SERIES  
MODEL  
PWR  
OUTPUT #1  
OUTPUT #2  
OUTPUT #3  
OUTPUT #4  
MTX-253-0512  
MTX-254-1205  
MTX-254-1212  
250  
250  
250  
+5V @ 35A  
+5V @ 35A  
+5V @ 35A  
+12V @ 8/12A pk  
+12V @ 8/12A pk  
+12V @ 8/12A pk  
-12V @ 2A  
-12V @ 2A  
-12V @ 2A  
+5V @ 1.5A  
+12V @ 2A  
And, you can increase power by 40%  
as you add peripherals – without  
redesigning for a larger power supply –  
by upgrading from the MDT 160/220  
series.  
Check the specifications of these low-  
profile, 9-inch switchers that give you  
more design freedom.  
Condor D.C. Power Supplies, Inc., A subsidiary of SL Industries, Inc. 805-486-4565 • (800) 235-5929 Fax: (805) 487-8911 http://www.condorpower.com  
2 5 0 , 3 5 0 WATTS  
9 ” x 5 ” x 2 .5 ”  
MAX, MS C, MTC, MTX  
MAX, MSC, MTC, MTX  
MAX, MSC, MTC, MTX with Option F  
3.4 lbs - 1.5 kgs  
3.9 lbs - 1.8 kgs  
Dimensions:  
Inches  
Millimeters  
*9.05  
229.87  
for MTX  
SPECIFICATIONS: ALL MODELS  
INPUT  
AC Input: 90-132 Vac/180-264 Vac, 47 to 63 Hz. User selectable. See option “Afor  
automatic line selection. Internally fused for 10 A.  
Inrush: Cold start AC current is less than 10 A at 115 Vac and 18 A at 230 Vac. For MTX  
models, 10 A at 115 Vac and 20 A at 230 Vac. Limited by thermistor.  
Holdup Time: 16 ms minimum after removal of power, at nominal line, full load.  
Efficiency: 80% typical.  
Option “P”, AC Power Fail: Provides TTL 0” 5 ms before output voltage goes out of  
regulation band upon loss of AC power. VMEbus compatible, provides 48 mA sink current  
capability. Not available if option “G” is selected.  
Option “V, Fan/Cover Assembly: Low profile, end venting cover with integral ball-bearing  
fan.  
Brownout Protection: Holds regulation to 85 Vac or 170 Vac.  
Consult factory for other available options.  
OUTPUT  
Adjustability: User adjustable ±5% minimum.  
Line & Load Reg: ±1% over AC input range and 0 to 100% load change. Output #1 requires  
minimum load of 10%.  
Ripple & Noise: Less than 1% p-p or 100 mV, whichever is greater.  
Remote Sense (Output #1): Compensates for 250 mV total line drop. Open sense lead  
protection.  
AC INPUT  
FUNCTION  
Input Select  
115 VAC  
230 VAC  
CONNECTOR  
Short  
Line  
Open  
0.187 Male Fastons  
Temperature Coefficient: 0.02% per degree C.  
Stability: 0.1% over 8 hours after 30 minutes warm-up.  
Transient Response (Output #1): Output voltage returns to within 1% in less than 500 µs for  
a 50% load change. Peak transient does not exceed 5%.  
TB1- (L)  
TB1- (N)  
Line 1  
Line 2  
Barrier strip  
#6-32 screws  
3/8” centers  
Neutral  
TB1- (  
)
Safety Ground  
Safety Ground  
Overload Protection: All outputs are protected against overload and short circuit. Automatic  
recovery upon removal of fault.  
Overvoltage Protection (Output #1): Protects load against power supply induced overvoltage.  
Trip point is factory set so that output voltage cannot exceed 136% of nominal.  
Remote Inhibit: Contact closure to the negative sense line drops output power to nominal zero.  
Reverse Voltage: Protected against reverse voltage up to supply current rating.  
DC OUTPUT  
FUNCTION  
MAX, MTC, MTX  
MSC  
CONNECTOR  
Output #1  
Terminal marked +V  
Bus bars  
#10/32 screws  
Terminal marked COM  
TB2-3 (+) TB2-2 (+)  
Output #2  
Output #3  
ENVIRONMENTAL  
TB2-4 Rtn (Common) TB2-1 Rtn (Common) Barrier strip  
#6-32 screws  
Thermal Protection: Shuts down power supply if overheated. Automatic recovery.  
Temperature Range: 0° to 50°C at full ratings. Derate to half power at 70°C.  
Safety Agencies: Most models are approved to UL1950; CSA 22.2 #234; IEC 950 and TÜV  
EN60950, Class 1 SELV., CE 72/23/EEC/93/68EEC (low voltage directive).  
Conducted RFI: Meets FCC Part 15, Subpart J, Class A; EN55022 Class B; CISPR 22 Class B.  
Cooling: 30 CFM required to achieve full ratings.  
TB2-5 (–)  
TB2-3(–)  
3/8” centers  
TB2-4 Rtn (Common) TB2-1 Rtn (Common)  
Output #4*  
TB2-1 (+)  
TB2-2 (–)  
(If provided)  
Output Isolation: Isolated from ground 50 Vdc.  
*Rtn connected to common only if output is polarized in product selection chart  
OPTIONS:  
STATUS AND CONTROL  
FUNCTION  
LOCATION  
NOTES  
CONNECTOR  
Option “A, AC Auto-Range: Automatically selects proper AC line voltage range to enable  
power operation at either 115 or 230 Vac without user intervention.  
Option “C, Cover: Limits contact with power supply interior.  
Option “F”, Fan/Cover Assembly: Cover with integral ball-bearing fan provides proper cooling  
to achieve full ratings at 50°C ambient temperature.  
J1-1(+ S)  
Output #1 Sense  
Output #1 Sense Rtn  
Reference to J1-2  
AMP MTA type  
#640456-4 pin  
header (locking)  
Remote Sense  
J1-2 (– S)  
J1-3 (PF)  
AC Power Fail or  
DC Power Good*  
Inhibit  
Option “G, DC Power Good: Provides a TTL “1” open collector when output #1 is above  
4.6 V nominal. Not available if option “P” is selected.  
J1-4 (IH)  
Short to J1-2  
*Optional function  
Condor D.C. Power Supplies, Inc., A subsidiary of SL Industries, Inc. 805-486-4565 • (800) 235-5929 Fax: (805) 487-8911 http://www.condorpower.com  

相关型号:

MAX-370

HIGH CURRENT TRANSIENT VOLTAGE SUPPRESSOR
MDE
MAXIM

MAX-400

400, 500 WATTS MULTIPLE OUTPUT
SLPOWER

MAX-403-0512

400, 500 WATTS MULTIPLE OUTPUT
SLPOWER

MAX-422

HIGH CURRENT TRANSIENT VOLTAGE SUPPRESSOR
MDE

MAX-450

HIGH CURRENT TRANSIENT VOLTAGE SUPPRESSOR
MDE

MAX-470

HIGH CURRENT TRANSIENT VOLTAGE SUPPRESSOR
MDE
MAXIM

MAX-500

MAX-500 Multiple Watt Output
SLPOWER

MAX-503-0512

400, 500 WATTS MULTIPLE OUTPUT
SLPOWER

MAX-504-1205

400, 500 WATTS MULTIPLE OUTPUT
SLPOWER

MAX-504-1205AF

MAX-500 Multiple Watt Output
SLPOWER